• 제목/요약/키워드: CT image

검색결과 1,600건 처리시간 0.043초

컴퓨터단층촬영 검사 시 테이블 높이에 따른 화질 특성에 관한 연구 (A Study on Characteristic of Image Quality according to CT Table Height in Computed Tomography )

  • 김기원;민정환;이상선;이영봉;이기종;박한솔;오주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.295-301
    • /
    • 2023
  • In addition to protocol adjustments during CT examinations, the height of the CT table can also affect image quality. Therefore, this study aimed to investigate the change in image quality depending on the height of the table in brain CT, which accounts for a large proportion of CT examinations, by measuring signal to contrast to noise ratio (CNR) and noise power spectrum (NPS) using the head phantom and evaluating them. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. The CNR result showed the highest value at 965 mm, which is the height adjacent to the center of the head phantom. NPS showed the lowest NPS at 915 mm, the center of the head phantom in the low frequency region. From these results, it can be seen that the height of the table in CT examination is closely related to the image quality, and it can be seen the characteristics of image quality according to CT table through quantitative evaluation methods such as CNR and NPS.

지역적 가중치 거리맵을 이용한 3차원 영상 정합 (Three-Dimensional Image Registration using a Locally Weighted-3D Distance Map)

  • 이호;홍헬렌;신영길
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제31권7호
    • /
    • pp.939-948
    • /
    • 2004
  • 본 논문에서는 동일 환자에 대해 시간차를 두고 촬영한 뇌 CT-CT 혈관조영영상간 움직임을 보정하기 위한 강인하고 고속의 정합방법을 제안한다. 먼저, 두 영상에서 3차원 경계검출 기법을 이용하여 특징점을 추출하고, 기준영상에서는 이를 지역적 가중치 3차원 거리맵으로 변환한다. 부유영상을 기준영상으로 강체변환하면서 두 경계간의 상관관계가 최대인 위치를 탐색한다. 이 때, 최대위치가 더 이상 변화하지 않고 일정 이상 반복되면 해당위치를 최적위치로 하여 부유영상을 최적위치로 변환시켜 두 영상을 정합한다. 실험을 위하여 인공영상을 사용하여 정화성과 강인성을 평가하였고, 육안평가를 위하여 뇌 CT-CT 혈관조영영상을 사용하였다. 본 제안방법은 지역적 가중치 3차원 거리맵을 이용함으로써 적은 샘플링 개수에도 국부최대인 위치에 수렴하지 않고 최적위치로 강인하면서 고속으로 영상이 정합되었다

뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식 (Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.961-968
    • /
    • 2019
  • 본 연구는 CT를 이용한 뇌혈관 추출 검사에서 이중에너지 기법을 활용하여 각 에너지 준위별 뇌혈관 조영술의 유용성을 평가하였다. 방법은 CT 뇌혈관 조영술을 시행한 환자 15명의 DE 영상과 SE 영상을 대상으로 하였다. 영상의 분석은 MCA, 뇌실직 조직, Background에 ROI를 설정하여 평균값, 표준편차 및 SNR, CNR 값을 구하고, SE영상과 비슷하게 구현되는 에너지 영역을 알아보았다. Likert 5점 척도 육안평가를 병행한 결과 DE 40 keV와 SE 120 kVp에서 가장 선명한 MCA 영상을 확인 하였다(p>0.05). SE영상의 SNR 값은 DE영상의 40 keV에너지 준위값과 비슷하게 측정되었고, 40 keV와 50 keV의 저에너지 준위의 영상이 SNR이 높게 측정되어 고에너지 준위의 영상에 비해 대조도가 높아 뇌혈관질환을 유용하게 관찰할 수 있을 것으로 사료된다.

금속성 치아충전물이 PET/CT영상이 미치는 영향 (The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image)

  • 김기진;배석환;한상현;유세종;이보우
    • 디지털융복합연구
    • /
    • 제10권2호
    • /
    • pp.243-247
    • /
    • 2012
  • 금속성 치아충전물이 있을 때 PET/CT검사를 시행하면 CT영상에서 선속경화인공음영이 발생한다. CT영상에 발생되는 인공음영에 의해 PET영상에 영향을 미칠 수 있다. 두경부종양이 있는 환자가 치과용 충전물이 있을 경우 CT영상에서 발생하는 선속경화인공음영에 의해 PET영상 및 SUV값에 변화를 줄 수 있다. 따라서 본 연구는 금속성치아충전물에 의한 HU 값의 변화에 따른 SUV값을 정량적으로 측정하여 임상적용에 있어 적절성을 평가 하였다. 연구대상은 2011년 8월에 PET/CT검사를 실시한 환자 47명이었다. 분석을 위해 CT와 PET영상에 2개의 ROI를 그려 이용하였다. 실험결과 충전물이 있을 경우 HU값과 SUV값이 증가 하였고 통계적으로도 유의한 차이를 보였다.(P<0.01) 이 증가 정도는 금속성 치아충전물이 없는 환자의 경우보다 큰 변화는 아니었지만 두경부 종양이 있을 경우 암의 진단시 과대평가가 될 수 있는 가능성이 충분하다. 따라서 임상에서 두경부 종양이 있는 환자를 대상으로 PET/CT 검사를 시행할 경우 판독상의 오류를 범하지 않도록 여러 물리학적, 생물학적인 부분에 대하여 고려를 해야 할 것이다.

CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구 (COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION)

  • 정기훈;김은경;김상준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

Spiral CT의 고속 영상재구성 알고리즘에 관한 연구 (A Study on the Fast Image Reconstruction Algorithm for Spiral CT)

  • 허창원;진승오;이재덕;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3207-3209
    • /
    • 2000
  • X-ray CT(Computed Tomography) has been a good modality for non-invasive diagnosis and recently, Conventional CT has been replaced rapidly with Spiral CT in recent. In X-ray CT, spiral scanning has various advantages such as better image quality, reduced scan time (in a single breath-hold), a lower x-ray dose. But, it requires very fast and high performance image processing system to reconstruct slice images from spiral scanning. This paper describes the fast image reconstruction techniques with filtered back projection from the viewpoints of fast algorithm as well as hardware implementation for real-time imaging.

  • PDF

CT Image Reconstruction of Wood Using Ultrasound Velocities I - Effects of Reconstruction Algorithms and Wood Characteristics -

  • Kim, Kwang-Mo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권5호통권133호
    • /
    • pp.21-28
    • /
    • 2005
  • For the proper conservation of wooden cultural properties, non-destructive evaluation (NDE) method, which can be used to quantitatively evaluate the internal state of wood members, are needed. In this study, an ultrasonic CT system composed of portable devices was attempted, and the capacity of this system was verified by reconstructing the CT images for two phantoms and two artificially defected specimens. Results from this study showed that the sizes of detected defects were enlarged and the shapes were distorted on the CT images. Also, the positions were shifted somewhat toward the surface of specimen, which is regarded due to the anisotropic property of wood. Compared to the filtered back-projection method, SIRT (simultaneous iterative reconstruction technique) method was determined to be more efficient as the algorithm of image reconstruction for wood. A new ultrasonic CT system is thought to be used as a NDE method for wood. However wood characteristics and wave diffraction within wood made it difficult to accurately evaluate the size, shape and position of defects. To improve the quality of CT image of wood, more research including the relationship between wood and ultrasound is needed, and wood properties should be taken into consideration on the image reconstruction algorithm.

얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교 (Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures)

  • 정종명;김종환;홍인표;최치훈
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

PACS에서 JPEG2000을 이용한 AAPM CT Performance Phantom영상의 압축에 따른 화질변화 (Change of Image Quality within Compression of AAPM CT Performance Phantom Image Using JPEG2000 in PACS)

  • 권순무
    • 한국방사선학회논문지
    • /
    • 제6권3호
    • /
    • pp.217-226
    • /
    • 2012
  • 본 연구는 PACS에서 JPEG200을 이용하여 AAPM CT Performance Phantom 영상을 다양한 비율로 압축 한 후 영상의 질 변화를 알아보았다. 원 영상을 기준으로 압축된 영상을 비교했을 때 물의 CT 계수 측정에서는 압축률 15:1에서 1.93%의 변화, 절편 두께 측정에서는 15:1에서 0.81% 의 변화를 보였다. 균일도는 규칙적인 변화나 통계적으로 유의한 차이가 나타나지는 않았다. 노이즈 측정의 경우 10:1에서 1.47%의 변화를 보이나 15:1에서 10.99%로 증가한 후 변화율 증가 폭이 확대되어 40:1에서 81.68%의 변화율을 보였다. CT 계수, 균일도, 절편 두께, 공간 분해능, 대조도 분해능의 경우 압축률 증가에 따라 영상의 화질 변화율도 증가하나 영향은 크지 않은 것으로 나타났다. 상대적으로 노이즈는 압축에 따른 영향을 많이 받는 것으로 나타났다. JPEG2000 압축 기법으로 AAPM CT Performance Phantom 영상을 평가한 결과 CT영상의 압축을 시행하는 경우 10:1정도의 압축률이 적정한 것으로 판단된다.