• Title/Summary/Keyword: CT image

Search Result 1,639, Processing Time 0.032 seconds

Manufacturing Techniques of Bronze Medium Mortars(Jungwangu, 中碗口) in Joseon Dynasty (조선시대 중완구의 제작 기술)

  • Huh, Ilkwon;Kim, Haesol
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.161-182
    • /
    • 2021
  • A jungwangu, a type of medium-sized mortar, is a firearm with a barrel and a bowl-shaped projectileloading component. A bigyeokjincheonroe (bombshell) or a danseok (stone ball) could be used as a projectile. According to the Hwaposik eonhae (Korean Translation of the Method of Production and Use of Artillery, 1635) by Yi Seo, mortars were classified into four types according to its size: large, medium, small, or extra-small. A total of three mortars from the Joseon period have survived, including one large mortar (Treasure No. 857) and two medium versions (Treasure Nos. 858 and 859). In this study, the production method for medium mortars was investigated based on scientific analysis of the two extant medium mortars, respectively housed in the Jinju National Museum (Treasure No. 858) and the Korea Naval Academy Museum (Treasure No. 859). Since only two medium mortars remain in Korea, detailed specifications were compared between them based on precise 3D scanning information of the items, and the measurements were compared with the figures in relevant records from the period. According to the investigation, the two mortars showed only a minute difference in overall size but their weight differed by 5,507 grams. In particular, the location of the wick hole and the length of the handle were distinct. The extant medium mortars are highly similar to the specifications listed in the Hwaposik eonhae. The composition of the medium mortars was analyzed and compared with other bronze gunpowder weapons. The surface composition analysis showed that the medium mortars were made of a ternary alloy of Cu-Sn-Pb with average respective proportions of (wt%) 85.24, 10.16, and 2.98. The material composition of the medium mortars was very similar to the average composition of the small gun from the Joseon period analyzed in previous research. It also showed a similarity with that of bronze gun-metal from medieval Europe. The casting technique was investigated based on a casting defect on the surface and the CT image. Judging by the mold line on the side, it appears that they were made in a piece-mold wherein the mold was halved and using a vertical design with molten metal poured through the end of the chamber and the muzzle was at the bottom. Chaplets, an auxiliary device that fixed the mold and the core to the barrel wall, were identified, which may have been applied to maintain the uniformity of the barrel wall. While the two medium mortars (Treasure Nos. 858 and 859) are highly similar to each other in appearance, considering the difference in the arrangement of the chaplets between the two items it is likely that a different mold design was used for each item.

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Diagnostic Value of Susceptibility-Weighted MRI in Differentiating Cerebellopontine Angle Schwannoma from Meningioma

  • Seo, Minkook;Choi, Yangsean;Lee, Song;Kim, Bum-soo;Jang, Jinhee;Shin, Na-Young;Jung, So-Lyung;Ahn, Kook-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.1
    • /
    • pp.38-45
    • /
    • 2020
  • Background: Differentiation of cerebellopontine angle (CPA) schwannoma from meningioma is often a difficult process to identify. Purpose: To identify imaging features for distinguishing CPA schwannoma from meningioma and to investigate the usefulness of susceptibility-weighted imaging (SWI) in differentiating them. Materials and Methods: Between March 2010 and January 2015, this study pathologically confirmed 11 meningiomas and 20 schwannomas involving CPA with preoperative SWI were retrospectively reviewed. Generally, the following MRI features were evaluated: 1) maximal diameter on axial image, 2) angle between tumor border and adjacent petrous bone, 3) presence of intratumoral dark signal intensity on SWI, 4) tumor consistency, 5) blood-fluid level, 6) involvement of internal auditory canal (IAC), 7) dural tail, and 8) involvement of adjacent intracranial space. On CT, 1) presence of dilatation of IAC, 2) intratumoral calcification, and 3) adjacent hyperostosis were evaluated. All features were compared using Chi-squared tests and Fisher's exact tests. The univariate and multivariate logistic regression analysis were performed to identify imaging features that differentiate both tumors. Results: The results noted that schwannomas more frequently demonstrated dark spots on SWI (P = 0.025), cystic consistency (P = 0.034), and globular angle (P = 0.008); schwannomas showed more dilatation of internal auditory meatus and lack of calcification (P = 0.008 and P = 0.02, respectively). However, it was shown that dural tail was more common in meningiomas (P < 0.007). In general, dark spots on SWI and dural tail remained significant in multivariate analysis (P = 0.037 and P = 0.012, respectively). In this case, the combination of two features showed a sensitivity and specificity of 80% and 100% respectively, with an area under the receiver operating characteristic curve of 0.9. Conclusion: In conclusion, dark spots on SWI were found to be helpful in differentiating CPA schwannoma from meningioma. It is noted that combining dural tail with dark spots on SWI yielded strong diagnostic value in differentiating both tumors.

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

  • Jeong, Dae-Kyo;Lee, Sam-Sun;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.273-279
    • /
    • 2019
  • Purpose: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT)(Siemens Healthineers, Erlangen, Germany). Materials and Methods: A bone density calibration phantom with 3 HA inserts of different densities(CTWATER®; 0, 100, and 200 mg of HA/㎤) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. Results: Hydroxyapatite density was strongly correlated with HU values(correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels(correlation coefficient= -0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU(P>0.05). Conclusion: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.

A three-dimensional finite element analysis of obturator prosthesis for edentulous maxilla (무치악 구개결손 환자를 위한 폐쇄장치의 삼차원 유한요소 분석)

  • Song, Woo-Seok;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.222-228
    • /
    • 2011
  • Purpose: The purposes of this study were to evaluate the stress distributions and the displacements of obturator for edentulous maxillectomy patients and to compare them with those of complete denture using three-dimensional finite element analysis. Materials and methods: Based on the CT image of edentulous patient, three-dimensional finite element model of edentulous maxillae was constructed. Three-dimensional finite element model of edentulous maxillae with palatal defect was also fabricated. On each model, complete denture and obturator prosthesis were created. Vertical static force of 200 N was applied on the left maxillary premolar and molar region. The von Mises stress values and the displacements of models were analyzed using three-dimensional finite element analysis. Results: Maximum von Mises stress values were recorded in the cortical bones of both models. The von Mises stress value in the complete denture model was 2.73 MPa and 2.69 MPa in the obturator model. High von Mises stress values were also observed on the tissue surface of prosthesis. The maximum value of the displacement in the obturator was higher than that of complete denture. Conclusion: The obturator showed a worse result in terms of stress distribution and displacement than complete denture. In the prosthodontic rehabilitation of edentulous maxillectomy patient accurate impression procedure based on patients'anatomy and application of prosthodontic principle should be considered.

Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy

  • Lee, Soon Sung;Min, Chul Kee;Cho, Gyu Suk;Han, Soorim;Kim, Kum Bae;Jung, Haijo;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • Radiotherapy patients should maintain their treatment position as patient setup is very important for accurate treatment. In this study, we evaluated patient setup error quantitatively according to Cone-Beam Computed Tomography (CBCT) Gamma Density Analysis using Mobius CBCT. The adjusted setup error to the $QUASAR^{TM}$ phantom was moved artificially in the superior and lateral direction, and then we acquired the CBCT image according to the phantom setup error. To analyze the treatment setup error quantitatively, we compared values suggested in the CBCT system with the Mobius CBCT. This allowed us to evaluate the setup error using CBCT Gamma Density Analysis by comparing the planning CT with the CBCT. In addition, we acquired the 3D-gamma density passing rate according to the gamma density criteria and phantom setup error. When the movement was adjusted to only the phantom body or 3 cm diameter target inserted in the phantom, the CBCT system had a difference of approximately 1 mm, while Mobius CBCT had a difference of under 0.5 mm compared to the real setup error. When the phantom body and target moved 20 mm in the Mobius CBCT, there are 17.9 mm and 13.5 mm differences in the lateral and superior directions, respectively. The CBCT gamma density passing rate was reduced according to the increase in setup error, and the gamma density criteria of 0.1 g/cc/3 mm has 10% lower passing rate than the other density criteria. Mobius CBCT had a 2 mm setup error compared with the actual setup error. However, the difference was greater than 10 mm when the phantom body moved 20 mm with the target. Therefore, we should pay close attention when the patient's anatomy changes.

Missed Skeletal Trauma Detected by Whole Body Bone Scan in Patients with Traumatic Brain Injury

  • Seo, Yongsik;Whang, Kum;Pyen, Jinsu;Choi, Jongwook;Kim, Joneyeon;Oh, Jiwoong
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.649-656
    • /
    • 2020
  • Objective : Unclear mental state is one of the major factors contributing to diagnostic failure of occult skeletal trauma in patients with traumatic brain injury (TBI). The aim of this study was to evaluate the overlooked co-occurring skeletal trauma through whole body bone scan (WBBS) in TBI. Methods : A retrospective study of 547 TBI patients admitted between 2015 and 2017 was performed to investigate their cooccurring skeletal injuries detected by WBBS. The patients were divided into three groups based on the timing of suspecting skeletal trauma confirmed : 1) before WBBS (pre-WBBS); 2) after the routine WBBS (post-WBBS) with good mental state and no initial musculoskeletal complaints; and 3) after the routine WBBS with poor mental state (poor MS). The skeletal trauma detected by WBBS was classified into six skeletal categories : spine, upper and lower extremities, pelvis, chest wall, and clavicles. The skeletal injuries identified by WBBS were confirmed to be simple contusion or fractures by other imaging modalities such as X-ray or computed tomography (CT) scans. Of the six categorizations of skeletal trauma detected as hot uptake lesions in WBBS, the lesions of spine, upper and lower extremities were further statistically analyzed to calculate the incidence rates of actual fractures (AF) and actual surgery (AS) cases over the total number of hot uptake lesions in WBBS. Results : Of 547 patients with TBI, 112 patients (20.4 %) were presented with TBI alone. Four hundred and thirty-five patients with TBI had co-occurring skeletal injuries confirmed by WBBS. The incidences were as follows : chest wall (27.4%), spine (22.9%), lower extremities (20.2%), upper extremities (13.5%), pelvis (9.4%), and clavicles (6.3%). It is notable that relatively larger number of positive hot uptakes were observed in the groups of post-WBBS and poor MS. The percentage of post-WBBS group over the total hot uptake lesions in upper and lower extremities, and spines were 51.0%, 43.8%, and 41.7%, respectively, while their percentages of AS were 2.73%, 1.1%, and 0%, respectively. The percentages of poor MS group in the upper and lower extremities, and spines were 10.4%, 17.4%, and 7.8%, respectively, while their percentages of AS were 26.7%, 14.2%, and 11.1%, respectively. There was a statistical difference in the percentage of AS between the groups of post-WBBS and poor MS (p=0.000). Conclusion : WBBS is a potential diagnostic tool in understanding the skeletal conditions of patients with head injuries which may be undetected during the initial assessment.

CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS (구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구)

  • Kim, Jae-Hwan;Kim, Kyung-Wook;Kim, Yong-Kack
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

Geometry of Resident's ridge with Multidetector-Row Computed Tomograph Image (다중검출기 컴퓨터 단층 영상 분석을 이용한 Resident's ridge의 형태학적 연구)

  • Roh, Jeong-Ho;Min, Byoung-Hyun;Park, Jeong-Wook;Ahn, Byung-Moon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.40-44
    • /
    • 2008
  • Purpose: The purpose of this study was to report the real geometry of Resident's ridge doing in anterior cruciate ligament reconstruction Materials and Methods: From Jan 2007 to Aug 2007, 48 cases which had normal distal femoral condyle analyzed with Multidetector-Row Computed Tomography. Resident's ridge was defined as change of height above 1 mm in lateral wall of intercondylar notch. Anterior-posterior length of intercondylar notch, length and height of Resident's ridge, distance of Resident's ridge from posterior cortex were estimated with 3-D reconstruction using $Lucion^{(R)}$ program. Results: Cases were $59{\pm}16$ years olds and male was 16 cases, female was 32 cases. 9 cases had no Resident's ridge, anterior-posterior length of intercondylar notch was $25.4{\pm}3.5$ mm, average of length and height of the Resident's ridge was $8.2{\pm}2.6,\;3.5{\pm}1.5$ mm. Distance of the Resident's ridge from posterior cortex was $7.6{\pm}2.6$ mm. Conclusion: Resident's ridge was used as landmark in anterior cruciate ligament reconstruction, which presented in many cases and which had distinct length and height.

  • PDF