• 제목/요약/키워드: CT evaluation

검색결과 1,309건 처리시간 0.035초

Spiral CT를 이용한 경동맥 질환의 평가 (The Evaluation of Carotid Artery Stenosis Using Spiral CT.)

  • 윤희석;황윤천;신현길;백천기;윤석민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권2호
    • /
    • pp.45-49
    • /
    • 1996
  • To determine the utility of spiral computed tomography(CT) in the evaluation of carotid artery stenosis, spiral CT images of 10 patients were compared with both ones of conventional angiography and magnetic resonance(MR) angiography. The severeness of stenosis was determined for each Internal carotid artery on the basis of arterial narrowness : mild stenosis : 40 % or less, moderate stenosis = $40{\sim}70%$, severe stenosis = greater than 70 % of arterial narrowness. The short examination and clear depiction of the arterial lumen In areas of complex or low flow make CT angiography attractive alternative to MR angiography. Spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional anglography.

  • PDF

반복적 연산으로 얻은 Sparse-view CT 영상에 대한 정량적 평가 (Quantitative Evaluation of Sparse-view CT Images Obtained with Iterative Image Reconstruction Methods)

  • 김혜선;;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.257-263
    • /
    • 2011
  • Sparse-view CT imaging is considered to be a solution to reduce x-ray dose of CT. Sparse-view CT imaging may have severe streak artifacts that could compromise the image qualities. We have compared quality of sparseview images reconstructed with two representative iterative reconstruction techniques, SIRT and TV-minimization, in terms of image error and edge preservation. In the comparison study, we have used the Shepp-Logan phantom image and real CT images obtained with a micro-CT. In both phantom image and real CT image tests, TV-minimization technique shows the best performance in error reduction and preserving edges. However, the excessive computation time of TV-minimization is a technical challenge for the practical use.

Basic Performance Evaluation of the First Model of 4-Dimensional CT-Scanner

  • Mori, Shinichiro;Endo, Masahiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuzi;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.376-378
    • /
    • 2002
  • This work was carried out to evaluate the basic performances for 4D CT, which employed continuously rotating conebeam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D CT has not yet been established, and we think this result was helpful to establish it. 4D CT can give dynamic volume imaging data continuously and with high-speed. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in longitudinal direction.

  • PDF

F-18 FDG PET/MRI와 PET/CT 전신 영상에서 VOI를 이용한 정상부위의 $SUV_{LBM}$-최대치에 의한 영상평가 (Image Evaluation Via $SUV_{LBM}$ for Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CT)

  • 박정규;김성규;조인호;공은정;박명환
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.68-75
    • /
    • 2013
  • 본 연구의 목적은 26명의 건강한 검진자들을 대상으로 PET/CT와 PET/MRI의 전신 영상에서 조기 정밀/ 진단 수준을 향상하고자 관심부피를 이용하여 정상부위의 $SUV_{LBM}$-최대치를 이용하여 PET/CT와 PET/MRI를 조영제 사용 유무와 관계없이 동시 평가할 수 있는 데이터를 구축하고자 하였다. 전신 F-18 FDG PET/CT와 전신 F-18 FDG PET/MRI의 정상부위의 VOI를 이용한 $SUV_{LBM}$-최대치평가는 PET/CT를 기준으로 PET/MRI의 영상은 매우 유의한 차이를 보였다(p<0.0001). 그러나 통계학적으로 높은 상관관계를 가진다(R>0.8). PET/MRI의 $SUV_{LBM}$ 평가 시 26.3% 감소하여 판단할 것과 조영제를 사용할 경우는 29.3% 감소하여 판단할 것으로 생각한다. PET/CT와 PET/MRI의 모든 영상의 판독에서는 $SUV_{LBM}$-최대치를 사용하는 것이 편리성과 효율성을 고려하여 임상의나 연구자들에게 많은 도움이 되리라 판단된다.

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장 (Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

Visualization of Tooth for Non-Destructive Evaluation from CT Images

  • Gao, Hui;Chae, Oksam
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.207-213
    • /
    • 2009
  • This paper reports an effort to develop 3D tooth visualization system from CT sequence images as a part of the non-destructive evaluation suitable for the simulation of endodontics, orthodontics and other dental treatments. We focus on the segmentation and visualization for the individual tooth. In dental CT images teeth are touching the adjacent teeth or surrounded by the alveolar bones with similar intensity. We propose an improved level set method with shape prior to separate a tooth from other teeth as well as the alveolar bones. Reconstructed 3D model of individual tooth based on the segmentation results indicates that our technique is a very conducive tool for tooth visualization, evaluation and diagnosis. Some comparative visualization results validate the non-destructive function of our method.

CT를 이용한 심장 기능 검사 (Using CT to Evaluate Cardiac Function)

  • 이종민
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.308-326
    • /
    • 2024
  • 심장 기능의 포괄적인 결과는 심장박출량과 전신 정맥 환류로 표현된다. 심장의 4개의 방실은 각자 고유한 기계적 기능을 가진다. 심장방실과 판막, 폐순환 시스템은 전부하 또는 후부하의 형태로 상호 연관되어 있다. 심장 기능 장애는 전반적인 심장 기능의 실패로 전형적인 임상 증상을 나타낸다. 심장 기능 장애의 근본 원인을 조사하려면 심장 내 혈류 유동 경로에 대한 단계별 평가가 필요하다. 이러한 맥락에서, 심장의 세부 구조를 볼 수 있는 영상검사의 표지자는 심장 기능 평가에 중요한 역할을 한다. 영상기반 평가를 통해 개별 심장 구성 요소의 기능을 단계별로 조사할 수 있다. 심장 기능 평가를 위한 영상검사 중 최근 심장 CT가 포함되고 검증되었다. 본 종설에서는 포괄적 및 단계별 심장 기능 평가를 위한 심장 CT 기반 영상 표지자에 대해 논의하겠다.

고급 모델 반복 재구성법 (ADMIRE)을 사용한 CT 영상에서의 노이즈 레벨 및 블라인드 화질 평가 (Evaluation of Noise Level and Blind Quality in CT Images using Advanced Modeled Iterative Reconstruction (ADMIRE))

  • 심지나;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.203-209
    • /
    • 2022
  • 전산화단층촬영장치 (Computed Tomography, CT)의 화질을 유지하면서 방사선량을 낮추기 위한 대표적인 방법 중에 하나는 모델기반 반복 재구성법 (Model-Based Iterative Reconstruction, MBIR)을 사용하는 것이다. 본 연구에서는 MBIR의 대표적인 모델로 잘 알려진 고급 모델 반복 재구성법 (Advanced Modeled Iterative Reconstruction, ADMIRE)의 강도를 조절하여 영상의 화질을 평가하고자 하였다. 연구는 팬텀을 사용하여 수행되었고, ADMIRE의 강도를 1에서부터 5까지 1 단위로 조절하면서 CT 영상을 획득하였다. 정량적 평가는 변동 계수 (coefficient of variation, COV)와 대조도 대 잡음비 (contrast to noise ratio, CNR)를 활용한 노이즈 레벨과 natural image quality evaluator (NIQE)와 blind/referenceless image spatial quality evaluator (BRISQUE)의 블라인드 품질 평가를 수행하였다. 결과적으로 노이즈 레벨 및 블라인드 품질 평가 결과에서 모두 ADMIRE의 강도가 높아질수록 우수한 결과가 도출되었다. 특히, COV와 CNR은 ADMIRE 1에 비하여 5에서 각각 1.89 및 1.75배 향상됨을 확인하였고, NIQE와 BRISQUE는 재구성 강도 1에 비하여 5에서 각각 1.35 및 1.22배 향상됨이 증명되었다. 결론적으로 ADMIRE의 재구성 강도는 CT 영상의 노이즈 레벨 및 전체적인 화질 평가에 큰 영향을 끼친다는 것을 증명하였다.