Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment (MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가)

  • Sun, Geo Jun;Son, Sang Jun;Lee, Yang Hoon;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.169-176
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate clinical applicability of Co-60 ViewRay treatment plan to increase the skin dose in case of high skin dose is required such as Malignant Fungating Wound By measuring the presence / absence of Bolus application and skin dose by the treatment device and comparing it Materials and Methods : Nine inner measuring points of 2.5 cm lattice arrangement and all 13 measuring points including upper and lower left and right measuring points touching the chest and skin were marked. After CT was taken, each treatment plan was formulated through Eclipse and ViewRay-TPS, and a Fixed beam-IMRT treatment plan was formulated so that the left chest V2Gy=95 % is delivered. Before measurement QED detector was calibrated and the QED detector was positioned at the 13 measurement points displayed on Phantom and surface dose of each treatment planner was measured using 5 mm Bolus application using True-beam and View-ray before and after, measure three times and compare each before applying 5 mm Bolus. Results : The surface dose of the Co-60 ViewRay and the linear accelerator appeared at $76.8%{\pm}5.2%$ vs. $67.3{\pm}%7.5%$ and the surface dose after application of 5 mm Bolus was $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$ It was measured at 10.2 % (p<0.001). Conclusion : As a result of the surface dose measurement of each treatment instrument, Co-60 ViewRay confirmed that the surface dose reached 95.6 % of 6 MV Linac with conventional 5 mm bolus, despite not using Bolus (p<0.001). Also, by utilizing magnetic resonance images for each treatment, it is possible to observe the change in the treatment site without the problem of exposure, it is easy to formulate an adaptive treatment plan and it is easy to secure the skin dose, so the size In the case of Malignant Fungating Wound patients who need fast skin changes and need high skin doses, Co-60 ViewRay is considered to be more useful than linear accelerators.

  • PDF

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

A Study on the Status of Startups and Their Nurturing Plans: Focusing on Startups in Seongnam City (스타트업 실태 및 육성방안에 관한 연구: 성남시 스타트업을 중심으로)

  • Han, Kyu-Dong;Jeon, Byung-Hoon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.5
    • /
    • pp.67-80
    • /
    • 2022
  • This study was conducted to derive policy measures such as fostering and supporting by examining the actual conditions of domestic startups. The subject of this study was the start-ups located in Seongnam-si, where Pangyo Techno Valley, which is the highest-level innovation cluster in Korea and is evaluated as a start-up mecca. Startups were defined as startups under 7 years old based on new technologies such as IT, BT, and CT, and the subjects of the study were selected. This can be seen as a step forward from previous research in that it embodies the concept of a startup that was previously abstract in a quantitatively measurable way. As a result of the analysis, about 94% of startups are distributed in the so-called "Death Valley" growth stage, and startups above scale-up, which means full-scale growth beyond BEP, account for about 6%. appeared to be occupied. He cited the problem of start-up funds as the biggest difficulty in the early stages of startups, and cited the loan evaluation method that prioritizes sales or collateral in raising funds as the biggest problem. In addition, start-ups rated the access to private investment capital such as VC, AC, and angel investors at a low level compared to policy funds, which are public funds. Most startups showed a lot of interest in overseas expansion, and they chose matching overseas investors such as overseas VCs as the biggest support for overseas expansion. The overall competitiveness in the overseas market was 49.6 points, which is less than 50 points out of 100, indicating that the overall competitiveness was somewhat inferior. It was analyzed that public support and investment in overseas sales channels (sales channels, distribution networks, etc.) should be prioritized along with enhancement of technological competitiveness in order for domestic startups to increase their competitiveness in overseas markets as well as in the domestic market.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Clinical Analysis of Ectopic Kidney in Children (소아 이소성 신장의 임상적 고찰)

  • Yook Jin-Won;Kim Ji-Hong;Kim Myung-Joon;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.196-202
    • /
    • 1999
  • Purpose : When the mature kidney fails to reach its norml location in the renal fossa, the condition is known as ectopic kidney. Presenting symtoms can be various and it generally depend on the associated anomaly. Beside urologic anomalies such as hydronephrosis and vesicoureteral reflux, various anomalous vascular net work, skeletal anomaly or genital anomaly can be observed in this condition. Methods : Sixteen children with ectopic kidney was studied retrospectively to analyse initial presentation, accompanied anomaly and prognosis. Results : 56% of the children were accompanied with other urologic anomalies such as true incontinence and vesicoureteral reflux that required surgical treatment. 31% of children were either diagnosed incidentally during evaluation of other non-urologic disease or during follow-up evaluation of abnormal antenatal renal sonogram. Conclusion : Ectopic kidney can be often misdiagnosed as tumorous condition or as a surgical condition depend on the abnormal location of the kidney. Careful evaluation using abdominal sonogram, DMSA, VCUG and abdominal CT scan should be performed in order to search for associated anomalous condition and for proper management.

  • PDF

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

Comparative Analysis of Patterns of Care Study of Radiotherapy for Esophageal Cancer among Three Countries: South Korea, Japan and the United States (한국, 미국, 일본의 식도암 방사선 치료에 대한 PCS($1998{\sim}1999$) 결과의 비교 분석)

  • Hur, Won-Joo;Choi, Young-Min;Kim, Jeung-Kee;Lee, Hyung-Sik;Choi, Seok-Reyol;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • Purpose: For the first time, a nationwide survey of the Patterns of Care Study(PCS) for the various radiotherapy treatments of esophageal cancer was carried out in South Korea. In order to observe the different parameters, as well as offer a solid cooperative system, we compared the Korean results with those observed in the United States(US) and Japan. Materials and Methods: Two hundreds forty-six esophageal cancer patients from 21 institutions were enrolled in the South Korean study. The patients received radiation theraphy(RT) from 1998 to 1999. In order to compare these results with those from the United States, a published study by Suntharalingam, which included 414 patients[treated by Radiotherapy(RT)] from 59 institutions between 1996 and 1999 was chosen. In order to compare the South Korean with the Japanese data, we choose two different studies. The results published by Gomi were selected as the surgery group, in which 220 esophageal cancer patients were analyzed from 76 facilities. The patients underwent surgery and received RT with or without chemotherapy between 1998 and 2001. The non-surgery group originated from a study by Murakami, in which 385 patients were treated either by RT alone or RT with chemotherapy, but no surgery, between 1999 and 2001. Results: The median age of enrolled patients was highest in the Japanese non-surgery group(71 years old). The gender ratio was approximately 9:1(male:female) in both the Korean and Japanese studies, whereas females made up 23.1% of the study population in the US study. Adenocarcinoma outnumbered squamous cell carcinoma in the US study, whereas squamous cell carcinoma was more prevalent both the Korean and Japanese studies(Korea 96.3%, Japan 98%). An esophagogram, endoscopy, and chest CT scan were the main modalities of diagnostic evaluation used in all three countries. The US and Japan used the abdominal CT scan more frequently than the abdominal ultrasonography. Radiotherapy alone treatment was most rarely used in the US study(9.5%), compared to the Korean(23.2%) and Japanese(39%) studies. The combination of the three modalities(Surgery+RT+Chemotherapy) was performed least often in Korea(11.8%) compared to the Japanese(49.5%) and US(32.8%) studies. Chemotherapy(89%) and chemotherapy with concurrent chemoradiotherapy(97%) was most frequently used in the US study. Fluorouracil(5-FU) and Cisplatin were the most preferred drug treatments used in all three countries. The median radiation dose was 50.4 Gy in the US study, as compared to 55.8 Gy in the Korean study regardless of whether an operation was performed. However, in Japan, different median doses were delivered for the surgery(48 Gy) and non-surgery groups(60 Gy). Conclusion: Although some aspects of the evaluation of esophageal cancer and its various treatment modalities were heterogeneous among the three countries surveyed, we found no remarkable differences in the RT dose or technique, which includes the number of portals and energy beams.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Aorta-esophageal Fistula That Developed after Endovascular Stent-grafting of a Mycotic Aneurysm - A case report- (감염성 대동맥류에 혈관 내 스텐트 삽입 시행 후 발생한 대동맥-식도루 - 1예 보고 -)

  • Nam, Jin-Hae;Park, Kay-Hyun;Yoo, Jae-Suk;Lee, Jae-Hang;Lim, Cheong;Jheon, Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.781-784
    • /
    • 2010
  • A 74-year-old woman presented at our hospital with hemoptysis. Three months ago, she had endovascular stent-grafting done by a general surgeon for a saccular thoracic aneurysm that was found accidentally following an episode of fever and chills. Despite a lasting fever after the procedure, she was discharged without further treatment and follow-up. She was subsequently admitted to the hospital for evaluation and several exams were performed. Chest CT scans and an esophagoscopy identified an aorto-esophageal fistula at the level of the aorta that was covered by a previous stent-graft. After extensive administration of antibiotics, surgery was done - esophagectomy, cervical esophago-gastrostomy and replacement of the thoracic aorta. She was later discharged uneventfully.

A Fat Density Mass in the Mediastinum (지방음영을 보인 종격동내 종괴)

  • Heo, Su Beom;Roh, Eun Suk;Kim, Dae Sung;Kim, Eui Hiung;Kang, Ji Ho;Lee, Sang Haak;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak;Park, Chan Beom;Lee, Bae Young;Kim, Hyeon Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.188-192
    • /
    • 2005
  • A 47-year-old female was admitted for an evaluation of a left mediastinal mass. The chest X-ray performed 16 months ago was normal, but the chest X-ray upon admission showed a large mass adjacent to the anterior aspect of the left hemidiaphragm. The CT scan demonstrated a large mass with a fat density in the left lower hemithorax. A focal diaphragmatic defect behind the xiphoid process was suspected. A thoracoscopic examination revealed omental herniation through the diaphragmatic defect. Therefore, a left thoracotomy was performed and the defect was repaired. We believe that a differential diagnosis should be needed to include a diaphragmatic omental hernia when a fat density mass is observed in the mediastinum.