• 제목/요약/키워드: CT contrast media

검색결과 81건 처리시간 0.045초

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

Effects of Remote Ischemic Pre-Conditioning to Prevent Contrast-Induced Nephropathy after Intravenous Contrast Medium Injection: A Randomized Controlled Trial

  • Dihia Belabbas;Caroline Koch;Segolene Chaudru;Mathieu Lederlin;Bruno Laviolle;Estelle Le Pabic;Dominique Boulmier;Jean-Francois Heautot;Guillaume Mahe
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1230-1238
    • /
    • 2020
  • Objective: We aimed to assess the effects of remote ischemic pre-conditioning (RIPC) on the incidence of contrast-induced nephropathy (CIN) after an intravenous (IV) or intra-arterial injection of contrast medium (CM) in patient and control groups. Materials and Methods: This prospective, randomized, single-blinded, controlled trial included 26 patients who were hospitalized for the evaluation of the feasibility of transcatheter aortic valve implantation and underwent investigations including contrast-enhanced computed tomography (CT), with Mehran risk scores greater than or equal to six. All the patients underwent four cycles of five minute-blood pressure cuff inflation followed by five minutes of total deflation. In the RIPC group (n = 13), the cuff was inflated to 50 mm Hg above the patient's systolic blood pressure (SBP); in the control group (n = 13), it was inflated to 10 mm Hg below the patient's SBP. The primary endpoint was the occurrence of CIN. Additionally, variation in the serum levels of cystatin C was assessed. Results: One case of CIN was observed in the control group, whereas no cases were detected in the RIPC group (p = 0.48, analysis of 25 patients). Mean creatinine values at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 88 ± 32 μmol/L, 91 ± 28 μmol/L and 82 ± 29 μmol/L, respectively (p = 0.73) in the RIPC group, whereas in the control group, they were 100 ± 36 μmol/L, 110 ± 36 μmol/L, and 105 ± 34 μmol/L, respectively (p = 0.78). Cystatin C values (median [Q1, Q3]) at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 1.10 [1.08, 1.18] mg/L, 1.17 [0.97, 1.35] mg/L, and 1.12 [0.99, 1.24] mg/L, respectively (p = 0.88) in the RIPC group, whereas they were 1.11 [0.97, 1.28] mg/L, 1.13 [1.08, 1.25] mg/L, and 1.16 [1.03, 1.31] mg/L, respectively (p = 0.93), in the control group. Conclusion: The risk of CIN after an IV injection of CM is very low in patients with Mehran risk score greater than or equal to six and even in the patients who are unable to receive preventive hyperhydration. Hence, the Mehran risk score may not be an appropriate method for the estimation of the risk of CIN after IV CM injection.

소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 - (Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography -)

  • 이희정;손순룡;이원홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.279-286
    • /
    • 2005
  • 목 적 : 소장조영술과 복부골반 CT검사의 진단 결과를 비교함으로써 방사선학적 영상의 특징 파악 및 질환에 따른 적절한 방사선학적 검사법을 선택하는데 기초자료를 제공하고자 한다. 대상 및 방법 : 1999년부터 2000년까지 소장조영술과 복부골반 CT검사를 병행하여 시행한 환자 284명을 대상으로 하여, 각각의 진단 소견을 병명별로 분류하였다. 소장조영술은 250 ml 황산바륨 현탁액(W/V 40W/V%, Methylcellulose+$BaSo_4$)을 경구로 복용시키고, Rt. recumbent position을 취하게 한 후 약 10분 후에 Carboxymethylcellulose solution(0.5%) 600 ml 복용시켰다. 20분, 40분, 1시간 정규촬영을 하고, 조영제가 회맹판(I-C valve)을 통과하면 투시 하에 저격촬영을 시행하였다. 복부골반전산화단층촬영은 검사 1시간 전에 $BaSO_4$+Methylcellulose 1.5 W/V% 450 ml를 복용시키고 검사직전 450 ml 추가로 복용시켰다. 요오드 성분의 비이온성 조영제 2.5 ml flow/sec로 주입하고, 조영제 주입 후 72초 지연 촬영을 하였다. 촬영은 간 상연에서부터 치골결합 부위까지 continuous scan을 시행하였으며, 검사 protocol은 Helical thick 5 mm, picth 1.375 : 1, speed 27.50, increment 5 mm, 120 kV, 245 mA로 하였다. 결 과 : 소장조영술에서는 정상(Normal)이 131예(46.1%), 감염성 장질환(Inflammatory bowel disease ; 이하 IBS)이 65예(22.9%), ischemia+ileocolitis+vasculitis 22예(7.7%), obstruction+stricture 21예(7.4%)의 순으로 나타났고, 복부골반 CT검사에서는 정상이 103예(36.3%) IBS가 65예(22.9%), wall thickening+lymphadenopathy가 42예(14.8%), fluid collection이 17예(6%)의 순으로 나타났다. 소장조영술과 복부골반 CT검사에서 동일하지 않은 결과로 진단된 경우는 소장조영술에서 정상으로 진단된 132명(46.1%) 중 14예(10.6%), 복부골반 CT검사 결과에서는 wall thickening+lymphadenopathy와 IBS로 진단되어 차이를 보였으며, 복부골반 CT검사 결과 정상으로 진단된 103예(36.3%) 중 5예(5.8%)가 소장조영술에서 ischemia+ileocolitis+vasculitis로 진단되었다. 정상으로 진단 된 235예 중 37예(15.9%)가 서로 다른 결과로 진단되어 통계적으로 유의한 차이를 보였다(P<0.05). 결 론 : 본 연구에서 특정질환에 특정검사의 진단결과가 우수하게 나타나는 것으로 조사되었으므로 방사선학적 검사의 진단적 민감도를 높이기 위해서는 처방 및 검사에 있어서 질환에 따른 적절한 검사법의 선택이 무엇보다도 중요하리라 사료된다.

  • PDF

정맥내의 IV 카테터 조각의 3D MDCT 재구성 영상 (Findings of an Intravenous Catheter Fragment in the Vein Using the 3D Image Reformations of MDCT)

  • 권대철;유병규;양성환;김정구
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.167-172
    • /
    • 2006
  • 전산화단층촬영에서 조영 증강을 위한 조영제 주입은 정맥내에 삽입한 카테터를 통해 자동주입기로 주입하고 있다. 정맥내에 위치한 카테터를 제거하는 도중에 IV 카테터가 부러져 정맥내에 남아 있는 카테터의 조각은 환자에게 순환기 질환의 위험을 초래할 수 있다. CT 검사 중에 정맥내에 카테터 조각이 남아있는 2명의 환자를 대상으로 카테터의 크기 및 위치를 정확히 확인하기 위해 MDCT를 이용하여 정맥내 주사부위를 스캔하였다. 3D 재구성은 MPR, MIP, 볼륨렌더링, SSD 등으로 구성하였다. 정맥내에 위치한 카테터 조각을 MDCT로 스캔한 데이터를 3D 재구성으로 정맥내의 위치 및 크기를 확인하였고, 카테터 조각을 제거하는데 일조하였다.

  • PDF

요방형근(Quadratus Lumborum) 통증 유발점 주사 후 나타난 후복막 혈종 -증례 보고- (Retroperitoneal Hematoma after Trigger Point Injections of Quadratus Lumborum -A case report-)

  • 심재용;박종민;배만석
    • The Korean Journal of Pain
    • /
    • 제12권2호
    • /
    • pp.263-267
    • /
    • 1999
  • We have observed retroperitoneal hematoma after trigger point injections of quadratus lumborum in a patient with chronic low back pain. Severe flank pain and dyspnea was observed three hours after injection of local anesthetic and steroid to the trigger point of quadratus lumborum muscle. There was fuge hematoma in abdominal CT image around the right kidney, which displaced and compressed the kidney anteriorly. Following infusion of contrast media, extravasation through renal vein and IVC was notified. Patient had a past history of having been treated with platelet aggregation inhibitor and lower dose aspirin treatment after cerebral ischemia for a year, but coagulative function was within normal range. Patient was admitted 12 days for bed rest, pain control and transfusion. We need to take greater care with a frequent aspiration and exact direction of needle, during trigger point injection of quadratus lumborum, particu right side, to avoid vascular injury.

  • PDF

외상성 골반 출혈환자에서 CT 혈관조영술 후 동맥 색전술을 시행하는 치료방침의 유용성: 단일 권역응급센터의 경험 (Treatment Strategy of Transcatheter Arterial Embolization after Pelvic CT Angiography in Traumatic Pelvic Hemorrhage : A Single Regional Emergency Center's Experience)

  • 이유진;제환준;차원철;서준석;김효철;신청일;신상도
    • Journal of Trauma and Injury
    • /
    • 제22권2호
    • /
    • pp.184-192
    • /
    • 2009
  • Purpose: This study was conducted to evaluate the effectiveness of the treatment strategy of transcatheter arterial embolization after pelvic CT angiography (CTA) in cases of traumatic pelvic hemorrhage. Methods: This is a retrospective analysis of pelvic hemorrhage patients who underwent transcatheter arterial embolization after pelvic CTA at our regional emergency center during a 31-month period. We reviewed the medical records and imagings of all these patients. Results: Transcatheter arterial embolization was performed in 17 patients (M:F=7:10, mean age=53.9) who underwent pelvic CTA for the evaluation of traumatic pelvic hemorrhage. Arterial bleeding was demonstrated on pelvic CTA in all patients, and the combined injury was also noted in 13 patients. The admission-to-CTA time was $84.53{\pm}66.92$ minutes, and the CTA-to-embolization time was $147.65{\pm}99.97$ minutes. Extravasation of contrast media or pseudoaneurysm was demonstrated on conventional angiography in all patients. Unilateral iliac artery embolization was performed in 8 patients, and bilateral iliac artery embolization was performed in 9 patients. Additional embolizations other than in the iliac arteries were performed in 7 patients. Initial hemostasis was achieved in 16 patients. One patient died of ongoing pelvic bleeding. Rebleeding occurred in only one patient and hemostasis was achieved with the second embolization. Another patient died of intracranial and facial bleeding in spite of pelvic hemostasis. The overall mortality was 11.8%, and there was no significant adverse effects in the other patients. Conclusion: Transcatheter arterial embolization after pelvic CTA is an effective treatment strategy in the management of traumatic pelvic hemorrhage patients.

자기공명(M.R.)진단법의 특징 및 그 영상기전의 이해 (Characteristics of Magnetic Resonance(M.R.) and Comprehension of its Imaging Mechanism)

  • 장재천;황미수;김선용
    • Journal of Yeungnam Medical Science
    • /
    • 제4권1호
    • /
    • pp.1-15
    • /
    • 1987
  • Magnetic Resonance (M.R.) is rapidly emerging technique that provides high quality images and potentially provides much more diagnostic information than do conventional imaging modalities. M.R.I. is conceptually quite different from currently used imaging methods. The complex nature of M.R.I. allows a great deal of flexibility in image product ion and available information, and key points are as follows. 1. M.R.I. offers a non-invasive technique with which to gene rate in vivo human images without ionizing radiation and with no known adverse biological effects. 2. Imaging mechanism of M.R.I. is quite different from conventional imaging modality and for more accurate diagnostic application, It is necessary for physician to understand imaging mechanism of M.R.I. 3. M.R. makes available basic chemical parameters that may provide to be useful for diagnostic medical imaging and more specific pathophysiologic information which are not available by alternate techniques. 4. M.R. can be produced by number of different methods. This flexibility allows the imaging technique to be applicated for particular clinical purpose. Multiplanar and three dimensional imaging may extend the imaging process beyond the single section available with current CT. 5. Future directions include efforts to; a. Further development of hard ware b. More fasternning scan time c. Respiratory and cardiac gated imaging d. Imaging of additional nuclei except hydrogen e. Further development of contrast media f. M.R. in vivo spectroscopy g. Real time M.R. imaging.

  • PDF

경추부 초음파 유도하 중재술 (Ultrasound-guided Intervention in Cervical Spine)

  • 문상호
    • 대한정형외과 초음파학회지
    • /
    • 제7권1호
    • /
    • pp.49-66
    • /
    • 2014
  • 지금까지 경추부 중재술은 방사선 투시하에 하는 것이 표준화된 방법이었다. 그러나 방사선을 피폭해야 하는 문제가 있으며, 실시간으로 조영제를 이용하여 투시하거나 컴퓨터단층촬영 유도하 시술로써 안전하게 시행하려는 노력에도 불구하고, 특히 경추간공 차단술에서, 예기치 않은 주사제의 동맥내 주입이 발생하여 심각한 합병증인 척수 손상, 소뇌 및 뇌간 경색 등의 증례들이 방사선 투시하 시술에서 보고되는 것이 사실이다. 최근에는 그 대안으로서 경추부 초음파 유도하 중재술이 시행되고 있는데, 초음파는 주요 신경 및 혈관 구조물들의 위치를 관찰하면서 목표 부위 주위로 주사제가 퍼져나가는 양상을 파악할 수 있다는 장점이 있기 때문이다. 또한 초음파는 방사선이 없고 간편하며 주사하는 동안 실시간으로 계속 영상을 제공함으로써 시술의 정확도를 높일 수 있는 술기이다. 결국 초음파 유도하 시술은 주요 신경과 혈관의 위치를 확인하면서 그에 대한 손상 혹은 주사를 피할 수 있기 때문에 이러한 구조물들의 손상 위험이 높은 경추부에서 안전하게 시행할 수 있다는 중요한 장점이 있는 술기이다. 그리하여 저자는 실시간 초음파 유도하라는 술기가 경추부 중재술에서 얼마나 유용한가에 대해 분석하여 기술하였다.

  • PDF

3차원 전산화 단층촬영을 이용한 상악 정중 과잉치의 진단 (THE DIAGNOSIS OF IMPACTED MAXILLARY MESIODENS USING 3-DIMENSIONAL COMPUTED TOMOGRAPHY : A CASE REPORT)

  • 홍영우;김성오;손흥규;이종갑
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.549-554
    • /
    • 1998
  • 저자는 매복된 상악 정중 과잉치를 주소로 내원한 환아를 3차원 전산화 단층촬영술을 이용해 매복된 과잉치의 위치를 파악하였으며 다음의 결론을 얻었다. 1. 인접한 영구치에 대한 위해한 영향을 주지 않기 위해 상악 정중 매복 과잉치의 정확한 위치 판별이 요구된다. 2. 3차원 전산화 단층촬영법은 매복 과잉치의 위치판별에 있어서 객관적인 중요한 정보를 제공한다.

  • PDF

MRI 분포와 관행수가 현황 및 촬영실적 분석 (Current Status of MRI Distribution, Prevailing Charges and Analysis of Its Performance)

  • 문옥륜;장원기;이상이;김철웅;최경혜
    • 보건행정학회지
    • /
    • 제8권1호
    • /
    • pp.155-182
    • /
    • 1998
  • There exists a remarkable differences in use of MRI scanning among income classes. The poor can hardly utilize it. This is because, among high cost technnologies, MRI is the only equipment not covered under health insurance benefits in Korea. This study was designed 1) to reveal the status of nation-wide MRI installation, customary charges and per unit annual scanning performance, and 2) to analyse factors influencing the above variables. The data for this study came from "MRI Prevalence Survey" conducted by the National Federation of Medcial Insurance(NFMI) in 1997, and were analyzed through SAS packages for T-test, analysis of variance and stepwise multiple regression. Data were collected from 188 hospitals equipped with MRI scanners. Major findings are summarized as follows : The number of MRI scanners has increased from 69 in 994 to 158 in 1996(2.3 times) while per unit annual scanning performance has risen by 11.2% from 2,173 cases in 1994 to 2,417 cases in 1996. Such a rapid increase was made possible mainly due to the inclusion of CT scanning under the health insurance benefit package. The customary charges for MRI scanning with or without contrast media, on average, amounted to 484,000 Won and 402,000 Won, respectively, with the percentile increase of 17.8% and 8.1% each during the same time. Korea ranks the third worldwidely in terms of number of MRI installations, 4.8 scanners per one million persons, only next to Japan and United States. Geographical variation of MRI, however, was rather high, 7.91 unit, in Cheju area compared to 1.82 in Kyongnam area. Variations of customary charges of MRI scanning can be explained as much as by 44.8% by both the total amount of claims to NFMI and geographical variable. The charges were more likely to be higher in metropolitan areas like Seoul and in hospitals with a bigger amount of claims. While those of per unit annual scanning performance can be explained as much as by 30.7% by both MRI installation cost and level of MRI-installed organizations. Per capital scannig performance was higher in tertiary hospitals and hospitals equipped with more expensive scanners than hospitals with less expensive scanners. Two measures are called for the remedying the existing excessive abundance in MRI units in korea : One is to set a ceiling of MRI units in an area like a province or a metropolitan district. The other is to establish a committee on introduction of high cost technologies for reviewing its effective use.ctive use.

  • PDF