• Title/Summary/Keyword: CT complex

Search Result 192, Processing Time 0.032 seconds

A study on the finite element modeling of femur based marching cube algorithm (Marching cube 알고리즘을 이용한 대퇴골의 유한요소 모델링에 관한 연구)

  • 곽명근;오택열;변창환;이은택;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1074-1077
    • /
    • 2002
  • Biomechanical behavior of the human femur is very important in various clinical situations. In this study, the data of FE models based on DICOM file exported from Computed tomography(CT). We generated FE models(voxel model, tetra model) of human femur using CT slide image. We compared them with Yon Mises stress results derived from finite element analysis(FEA). Comparing the two models, we found a correlation of them. As a result, the tetra model based proposed marching cube algorithm is a valid and accurate method to predict parameters of the complex biomechanical behavior of human femur.

  • PDF

ON OPERATORS T COMMUTING WITH CT C WHERE C IS A CONJUGATION

  • Cho, Muneo;Ko, Eungil;Lee, Ji Eun
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.1
    • /
    • pp.69-79
    • /
    • 2020
  • In this paper, we study the properties of T satisfying [CTC, T] = 0 for some conjugation C where [R, S] := RS - SR. In particular, we show that if T is normal, then [CTC, C] = 0. Moreover, the class of operators T satisfy [CTC, T] = 0 is norm closed. Finally, we prove that if T is complex symmetric, then T is binormal if and only if [C|T|C, |T|] = 0.

Low-dose CT Image Denoising Using Classification Densely Connected Residual Network

  • Ming, Jun;Yi, Benshun;Zhang, Yungang;Li, Huixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2480-2496
    • /
    • 2020
  • Considering that high-dose X-ray radiation during CT scans may bring potential risks to patients, in the medical imaging industry there has been increasing emphasis on low-dose CT. Due to complex statistical characteristics of noise found in low-dose CT images, many traditional methods are difficult to preserve structural details effectively while suppressing noise and artifacts. Inspired by the deep learning techniques, we propose a densely connected residual network (DCRN) for low-dose CT image noise cancelation, which combines the ideas of dense connection with residual learning. On one hand, dense connection maximizes information flow between layers in the network, which is beneficial to maintain structural details when denoising images. On the other hand, residual learning paired with batch normalization would allow for decreased training speed and better noise reduction performance in images. The experiments are performed on the 100 CT images selected from a public medical dataset-TCIA(The Cancer Imaging Archive). Compared with the other three competitive denoising algorithms, both subjective visual effect and objective evaluation indexes which include PSNR, RMSE, MAE and SSIM show that the proposed network can improve LDCT images quality more effectively while maintaining a low computational cost. In the objective evaluation indexes, the highest PSNR 33.67, RMSE 5.659, MAE 1.965 and SSIM 0.9434 are achieved by the proposed method. Especially for RMSE, compare with the best performing algorithm in the comparison algorithms, the proposed network increases it by 7 percentage points.

Surgical Simulation Environment for Replacement of Artificial Knee Joint (CT 영상을 이용한 무릎관절 모의 치환 시술 환경)

  • Kim, Dong-Min
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.119-126
    • /
    • 2003
  • This paper presents a methodology for constructing a surgical simulation environment for the replacement of artificial knee join using CT image data. We provide a user interface of preoperative planning system for performing complex 3-D spatial manipulation and reasoning tasks. Simple manipulation of joystick and mouse has been proved to be both intuitive and accurate for the fitness and the wear expect of joint. The proposed methodology are useful for future virtual medical system where all the components of visualization, automated model generation, and surgical simulation are integrated.

  • PDF

Evaluation of Contaminant Concentrations in Wet and Dry Seasons during Pump-and-Treat Pilot Tests

  • Jeon, Woo-Hyun;Lee, Jin-Yong;Kwon, Hyung-Pyo;Jun, Seong-Chun;Cheon, Jeong-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.18-31
    • /
    • 2013
  • This study was performed to examine use of the pump-and-treat method for remediation of TCE, CF and CT in groundwater contaminated by DNAPL. The Woosan industrial complex is located in Wonju, about 120 km east of Seoul, Korea. Two pumping wells (KDPW7 and KDPW8) and five monitoring wells (KDMW7, KDMW8, KDMW9, KDMW10, and SKW2) were installed for the test. An asphalt laboratory is a main source of the extensive subsurface contamination at this site. To evaluate change in the concentrations of TCE, CF, and CT in groundwater in the study area, three rounds of pump-and-treat pilot tests were performed (6 July to 6 August, 22 August to 6 September, and 19 September to 2 December in 2011). The groundwater levels and the concentrations of TCE, CF, and CT exhibited negative correlations in the wet season but positive correlations in the dry season, which suggests that the TCE concentrations were mainly controlled by dilution through rainfall during the wet season and by residual TCE, CF, and CT in the unsaturated zone during the dry season. These possibilities should be considered in the full-scale remediation plan.

Retinopathy Induced by Zinc Oxide Nanoparticles in Rats Assessed by Micro-computed Tomography and Histopathology

  • Kim, Young Hee;Kwak, Kyung A;Kim, Tae Sung;Seok, Ji Hyeon;Roh, Hang Sik;Lee, Jong-Kwon;Jeong, Jayoung;Meang, Eun Ho;Hong, Jeong-sup;Lee, Yun Seok;Kang, Jin Seok
    • Toxicological Research
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • Nanotechnology has advanced at an extremely rapid pace over the past several years in numerous fields of research. However, the uptake of nanoparticles (NPs) into the body after administration through various routes may pose a risk to human health. In this study, we investigated the potential ocular toxicity of 20-nm, negatively- charged zinc oxide (ZnO) NPs in rats using micro-computed tomography (micro-CT) and histopathological assessment. Animals were divided into four groups as control group, ZnO NPs treatment group (500 mg/kg/day), control recovery group, and ZnO NPs treatment and recovery group. Ocular samples were prepared from animals treated for 90 days (10 males and 10 females, respectively) and from recovery animals (5 males and 5 females, respectively) sacrificed at 14 days after final treatment and were compared to age-matched control animals. Micro-CT analyses represented the deposition and distribution of foreign materials in the eyes of rats treated with ZnO NPs, whereas control animals showed no such findings. X-ray fluorescence spectrometry and energy dispersive spectrometry showed the intraocular foreign materials as zinc in treated rats, whereas control animals showed no zinc signal. Histopathological examination revealed the retinopathy in the eyes of rats treated with ZnO NPs. Neuronal nuclei expression was decreased in neurons of the ganglion cell layer of animals treated with ZnO NPs compared to the control group. Taken together, treatment with 20-nm, negatively-charged ZnO NPs increased retinopathy, associated with local distribution of them in ocular lesions.

Modifications Induced by Organic Solvents to Aeromonas hydrophila IB Bct4 (유기용매에 의하여 유발된 Aeromonas hydrophila Bct4의 변형)

  • Lazaroaie, Mihaela Marilena
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.325-334
    • /
    • 2009
  • Many bacteria that are capable to tolerate and degrade organic solvents have been isolated from seawater. However, their roles in the biodegradation of organic solvents in the marine environment have remained unknown. Aeromonas hydrophila IB$B_{ct4}$, isolated from Constanta seawater, was able to tolerate and degrade different organic solvents. Toluene, styrene, xylene isomers, ethylbenzene, with the logarithm of the partition coefficient in octanol-water mixture (log $P_{ow}$) between 2.64 and 3.17, were more toxic for bacterial cells, compared with propylbenzene, n-hexane, n-heptane, with log $P_{ow}$ between 3.69 and 4.39. There were revealed cellular and molecular modifications induced by organic solvents to Aeromonas hydrophila IB$B_{ct4}$. The study of cellular and molecular modifications induced by different organic solvents showed a complex response of bacterial cells to the presence of organic solvents in the culture media.

Computed tomographic features of the temporomandibular joint in 10 Jeju horses

  • Lee, Seyoung;Lee, Eun-Bee;Park, Kyung-Won;Jeong, Hyohoon;Shin, Kwang-Yun;Kweon, Young-Park;Seo, Jong-pil
    • Journal of Veterinary Science
    • /
    • v.23 no.3
    • /
    • pp.44.1-44.10
    • /
    • 2022
  • Background: The equine temporomandibular joint (TMJ) has a complex anatomical structure that makes diagnosis of TMJ disorders difficult. Computed tomography (CT) is now available in equine medicine; hence, TMJ evaluation has become more convenient. Objectives: The objectives of this study were to describe the CT features of the TMJ in Jeju horses and to compare these features with those of Thoroughbreds. Methods: In this report, the TMJs of 10 Jeju horses (mean age: 4.5 ± 1.9 yr; mean body weight: 282.6 ± 40.3 kg) and 6 Thoroughbreds (mean age: 7.3 ± 1.6 yr; mean body weight: 479.7 ± 44.0 kg) were examined using CT. After CT scanning, the Hounsfield units (HU) and height to width ratio (H:W) of the mandibular condyle were measured. Results: The mean H:W in Jeju horses was significantly lower than that in Thoroughbreds. The mean HU in Jeju horses was lower than that in Thoroughbreds; however, the difference was not significant. The most frequent CT finding was an irregular medial margin of the mandibular condyle in both breeds. Conclusions: In this study, the shape of the mandibular condyle in Jeju horses was flatter than that in Thoroughbreds. This report could be useful in evaluating the TMJ in Jeju horses. Moreover, CT could be a pragmatic choice for the examination of the TMJ in horses.

Comparison Study of Conventional Film-based and CT-reconstruction method in HDR Brachytherapy (고선량률 근접 방사선 치료에서 기존의 필름 방법과 CT 재구성 방법의 비교 연구)

  • 장지나;이형구;윤세철;서태석
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.63-69
    • /
    • 2004
  • HDR brachytherapy administers a large dose of radiation in a short time compare with LDR, and its optimization for treatment is related to several complex factors, such as physical, radiation and optimization algorithms, so there is a need for these to be verified for accurate dose delivery. In our approach, a previous study concerning the phantom for dose verification has been modified, and a new pelvic phantom fabricated for the purpose of localization, including a structure enabling the use of a CT or MRI system. In addition, a comparison study was performed to verify an orthogonal method that is commonly used for brachytherapy localization by comparing target coordinates from a CT system. Since the developed phantom was designed to simulate the clinical setups of cervix cancer, it included an air-filled bladder and a rectum structure shaped sphere and cylinder An N-shaped localizer was used to obtain precision coordinates from both CT and films. Moreover, the IDL 5.5 software program for Windows was used to perform coordinates analysis based on an orthogonal algorithm. The film results showed differences within 1.0 mm of the selected target points compare with the CT coordinates. For these results, a Plato planning system (Nucletron, Netherlands) could be independently verified using this phantom and software. Furthermore, the new phantom and software will be efficient and powerful qualify assurance (QA) tools in the field of brachytherapy QA.

  • PDF

Reconstruction of Head Surface based on Cross Sectional Contours (단면 윤곽선을 기반으로 한 두부표변의 재구성)

  • 한영환;성현경;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.365-373
    • /
    • 1997
  • In this paper, a new method of the 3D(dimensional) image reconstruction is proposed to build up the 3D image from 2D images using digital image processing techniques and computer graphics. First, the new feature extraction algorithm that doesn't need various input parameters and is not affected by threshold is adopted This new algorithm extracts feature points by eliminating some undesirable points on the ground of the connectivity. Second, as the cast function to reconstruct surfaces using extracted feature points, the minimum distance measure between two plane images has been adopted According to this measure, the surface formation algorithm doesn't need complex calculation and takes the form of triangle or trapezoid To investigate usefulness, this approach has been applied to a head CT image and compared with other methods. Experimental comparisons show that the suggested algorithm yields better performance on feature extraction than others. In contrast with the other methods, the complex calculation for surface formation in the proposed algorithm is not necessary.

  • PDF