• Title/Summary/Keyword: CT angiography

Search Result 353, Processing Time 0.032 seconds

Rupturing Anterior Communicating Artery Aneurysm during Computed Tomography Angiography : Three-Dimensional Visualization of Bleeding into the Septum Pellucidum and the Lateral Ventricle

  • Kim, Ealmaan
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.6
    • /
    • pp.357-361
    • /
    • 2014
  • Computed tomography angiography (CTA) is commonly used in setting of subarachnoid hemorrhage, but imaging features of aneurysm rupturing taking place at the time of scanning has rarely been described. The author reports a case of actively rebleeding aneurysm of the anterior communicating artery with intraventricular extravasation on the hyperacute CTA imaging. The rebleeding route, not into the third ventricle but into the lateral ventricles, can be visualized by real-time three-dimensional CT pictures. The hemorrhage broke the septum pellucidum and the lamina rostralis rather than the lamina terminalis.

Persistent Hypoglossal Artery

  • Ahn, Jae-Heung;Choe, Woo-Jin;Park, Hyo-Il;Lee, Chae-Heuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.312-315
    • /
    • 2005
  • The persistent hypoglossal artery[PHA] is a rare anomaly that belongs to the group of embryonic carotid-basilar artery anastomoses that may occur in adults. The most commonly reported type of such an anastomosis is the primitive trigeminal artery, followed by the PHA. We report a 35-year old man, hospitalized because of an intraventricular hemorrhage, who was found to have a right persistent PHA. Three-dimensional computed tomography[CT] angiography provided excellent anatomical topology of the anomaly. To our knowledge, this patient is the first case of a PHA identified by this means in Korea.

Coronary Artery Anomaly, What Radiologist Should Know? (영상의학과 의사가 꼭 알아야 할 관상동맥기형)

  • Hyun Jin Lee;Jin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.84-101
    • /
    • 2022
  • Cardiac CT is the most accurate tool for diagnosing and evaluating coronary artery anomalies. Coronary anomalies can often be observed as the number of cardiac CT scans increases. In this review article, we described the CT findings and clinical significance of coronary anomalies that radiologists should know. In particular, we described the dangerous anatomical findings of coronary anomalies on CT images in detail.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images (심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출)

  • Kim, Hye-Ryun;Kang, Mi-Sun;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • Computed tomographic angiography (CTA) is widely used in the diagnosis and treatment of coronary artery disease because it shows not only the whole anatomical structure of the cardiovascular three-dimensionally but also provides information on the lesion and type of plaque. However, due to the large size of the image, there is a limitation in manually extracting coronary arteries, and related researches are performed to automatically extract coronary arteries accurately. As the coronary artery originate from the ascending aorta, the ascending aorta and ostium should be detected to extract the coronary tree accurately. In this paper, we propose an automatic segmentation for the ostium as a starting structure of coronary artery in CTA. First, the region of the ascending aorta is initially detected by using Hough circle transform based on the relative position and size of the ascending aorta. Second, the volume of interest is defined to reduce the search range based on the initial area. Third, the refined ascending aorta is segmented by using a two-dimensional geodesic active contour. Finally, the two ostia are detected within the region of the refined ascending aorta. For the evaluation of our method, we measured the Euclidean distance between the result and the ground truths annotated manually by medical experts in 20 CTA images. The experimental results showed that the ostia were accurately detected.

Comparison of Radiation Doses between 64-slice Single Source and 128-slice Dual Source CT Coronary Angiography in patient (64-slice single source CT와 128-slice dual source CT를 이용한 관상동맥 조영 검사 시 환자선량 비교)

  • Kang, Yeong-Han
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • The purpose of this study was to estimate radiation doses from 64-slice single source Computed Tomography(SSCT) coronary angiography(CA) and 128-slice dual source Computed Tomography(DSCT). With SSCT CA, the effective dose averaged approximately 13.86 mSv when two dose modulation was not. The mean effective dose for DSCT CA with retrospectively gated helical(RGH) technique was 11.87 mSv, when prospective ECG gating transverse(PGT) without dose modulation technique was 5.61 mSv. The one with dose modulation in PGT technique and flash mode were 3.04 mSv and flash mode was 0.98 mSv respectively. The lifetime attributable risk(LAR) of cancer incidence from SSCT RGH mode averaged approximately 1 for 1,176, and DSCT averaged 1 for 1,960(RGH mode), 1 for 3,030(PGT without modulation), 1 for 5,882(PGT with modulation). Because of CTCA is associated with non-negligible risk of cancer. Doses can be reduced by application PGT, FLASH than RGH using DSCT.

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Brain Segmentation on CT Angiography with Slice Information (CT 혈관조영영상에서 슬라이스 정보를 이용한 뇌 분할)

  • Lee, Byeong-Hun;Lee, Ho;Hong, Helen
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.904-906
    • /
    • 2005
  • 본 논문에서는 뇌 CT 혈관조영영상에서 슬라이스 정보를 이용한 뇌 분할 방법을 제안한다. 뇌 분할 과정은 현재 슬라이스와 이전 슬라이스 간 분할 영역의 크기 정보를 가지고 영역 성장 단계와 전파 단계로 구분하여 수행된다. 영역 성장 단계에서는 이차원 영역성장법을 통해 뇌 분할을 수행하고 누출이 발생하는 슬라이스에 대하여 방사선 투과 기법을 통해 영역보정을 수행한다. 전파 단계에서는 이전 슬라이스에서 분할된 뇌 영역을 현재 슬라이스로 전파함으로써 장벽을 생성하고 장벽 내에서 이차원 영역성장법을 수행함으로써 누출을 최소화한다. 또한 뇌 영역과 유사한 밝기값을 형성하고 있는 미세 요소들을 제거하기 위해 이차원 연결화소군 레이블링 기법을 통해서 최종적으로 뇌 분할을 수행한다. 본 논문의 실험을 위하여 뇌 CT 혈관조영영상을 사용하여 정확한 뇌분할 결과를 얻었다.

  • PDF

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Computed Tomography for Diagnosing Chylothorax Associated with Cranial Vena Cava Thrombosis in a Dog

  • Jin-Yoo Kim;Gunha Hwang;Sumin Kim;Chi-Oh Yun;Seunghwa Lee;Na-Young Eom;Joong-Hyun Song;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.183-188
    • /
    • 2024
  • A 13-year-old male neutered Miniature Pinscher presented with coughing and dyspnea. The dog had been coughing for the past 4 weeks. The patient had mild dehydration on physical examination, and muffled heart sounds were detected. Thoracic radiographs revealed pleural effusion, which was consistent with chylous effusion based on cytological and biochemical evaluations. Computed tomography (CT) lymphangiography, which was performed via intrametatarsal pad injection, revealed no evidence of thoracic duct rupture or obvious leakage. On CT angiography (CTA), an intraluminal filling defect was identified in the cranial vena cava (CrVC). CrVC thrombosis with secondary chylothorax was diagnosed based on CT lymphangiography and CTA. Clopidogrel, rivaroxaban, and recombinant tissue-plasminogen activator were prescribed. The follow-up CTA, 4 months after diagnosis, revealed a decrease in the thrombus, and no pleural effusion was identified. Although CrVC thrombosis is an uncommon presentation in veterinary patients, thrombus in the CrVC should be considered as a differential diagnosis of chylothorax in dogs. CT lymphangiography and CTA could be helpful in identifying and differentiating the underlying etiologies of chylothorax.