• Title/Summary/Keyword: CT angiography

Search Result 323, Processing Time 0.028 seconds

Usefulness of Three-Dimensional CT Image in Meningioma Using Contrast Method (조영법을 이용한 뇌수막종에서 3차원 CT영상의 유용성)

  • Lee, Jun-Haeng;Baek, Sung-Eun;Lee, Sang-Bock;Kim, Yong-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2008
  • Because of the reason that the meningioma is enhanced lately, we started the study to maximally enhance the meningioma. we were to know the relation between meningioma and vessels in the skull and compared 3D CT angiography with the conventional angiography. we got the data from 6 patients performed by both 3D CT angiography and there were 5 cases in sphenoidal ridge and 1 case parasagittal sinus. Injecting the contrast media at 3 ml/sec, 120 ml and then the CT number reached 100, we started the study using the medical system Program(smart prep). The scan parameters were HS-Mode(1.25 mm / 7.5 mm) right after being injected all and reconstructed with 0.5 mm interval. We compared the study with the conventional angiography after reconstructing the images required by using 3D-Med software Program(Rapidia). Seeing the consequences, the maximum enhancing time in the menigioma is about 120~180 seconds after injecting the contrast media and we distinguished the relation between vessels and tumors at the time and 1 case showed us the aneurysm with a tumor clearly at the time too. It was very helpful to the operation that the 3D images required by injecting the contrast media to the patients with meningioma distingushed between tumors and vessels dimensionally.

  • PDF

Fast 3D CT/CTA Image Registration and its Application to DS-CTA (고속 3차원 CT/CTA 영상 정합 기법 및 DS-CTA 응용)

  • 권성민;김용선;김태성;김동익;나종범
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2697-2700
    • /
    • 2003
  • 이 논문에서는 3 차원 CT/CTA 영상 데이터에 대하여 고속 자동 정합 기법을 제안한다. 제안하는 기법은 다해상도 (multi-resolution) 구조의 정규 상호 정보량(normalized mutual information) 을 최대화하는 정합 방식에서, 정합 유사도를 계산하는 볼륨 영역을 효율적으로 줄여 정합 속도를 증가시키는 방법이다. 제안된 정합방식을 CT/CTA (CT angiography) 팬텀 데이터와 7 세트의 실제 CT/CTA 임상 데이터에 적용하여 테스트하였다. 이로부터 제안하는 방식이, 정합 정확도를 유지하는 동시에 정합 속도를 10 ∼ 60% 로 감소시킴을 확인 할 수 있었다. 또한 제안된 정합 방식을 DS-CTA (digital subtraction CT angiography) 에 적용하여, CT/CTA 영상으로부터 혈관 영상을 성공적으로 추출하였다.

  • PDF

CT Assessment of Myocardial Perfusion and Fractional Flow Reserve in Coronary Artery Disease: A Review of Current Clinical Evidence and Recent Developments

  • Chun-Ho Yun;Chung-Lieh Hung;Ming-Shien Wen;Yung-Liang Wan;Aaron So
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1749-1763
    • /
    • 2021
  • Coronary computed tomography angiography (CCTA) is routinely used for anatomical assessment of coronary artery disease (CAD). However, invasive measurement of fractional flow reserve (FFR) is the current gold standard for the diagnosis of hemodynamically significant CAD. CT-derived FFRCT and CT perfusion are two emerging techniques that can provide a functional assessment of CAD for risk stratification and clinical decision making. Several clinical studies have shown that the diagnostic performance of concomitant CCTA and functional CT assessment for detecting hemodynamically significant CAD is at least non-inferior to that of other routinely used imaging modalities. This article aims to review the current clinical evidence and recent developments in functional CT techniques.

Traumatic Pseudoaneurysm of the Superficial Temporal artery Diagnosed by 3-dimensional CT Angiography

  • Park, In-Ho;Kim, Hyeun-Sung;Park, Sung-Kuen;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.4
    • /
    • pp.209-211
    • /
    • 2008
  • Pseudoaneurysm arising from the superficial temporal artery (STA) is a rare and potentially critical cause of palpable mass. Most pseudoaneurysms form as a result of blunt trauma and present as painless, pulsatile mass that may be associated with pathologic finding and enlarged size. We report a rare case of pseudoaneurysm arising from STA caused by blunt injury and diagnosed by 3-dimensional computed tomography (CT) angiography.

Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography (컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발)

  • Kim, S.H.;Suh, T.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF

Congenital portal vein aplasia with portocaval shunting in two dogs

  • Hwang, Taesung;Moon, Jonghyun;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.3
    • /
    • pp.171-173
    • /
    • 2019
  • Two dogs presented with vomiting and head pressing. In both dogs, a large vessel was revealed in computed tomography (CT) angiography, which was found to leave the portal vein (PV) cranial to the splenomesenteric confluence and enter the pre-hepatic caudal vena cava cranial to the right renal vein. The flow of portal blood to the liver was not identified. Based on CT angiography, the dogs were suspected to have congenital PV aplasia with portocaval shunting. Diagnostic imaging of potential malformations for PV continuation should be conducted before attempting shunt closure.

A Pseudoaneurysm Appeared after Rebleeding

  • Hwang, Sung-Nam;Kim, Kyoung-Tae;Nam, Taek-Kyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.134-136
    • /
    • 2007
  • A woman who had a spontaneous subarachnoid hemorrhage [SAH] and temporal intracerebral hemorrhge [ICH] without any causative lesions on computed tomography [CT] and digital angiography at the day of the stroke. She was considered to have an angiographically negative SAH and scheduled for a repeated angiography. While she was waiting for the next study, she developed a second hemorrhage. CT angiography showed an aneurysmal shadow in the course of the posterior cerebral artery. After the operation, the aneurysm proved to be a pseudoaneurysm.

Distal Middle Cerebral Artery M4 Aneurysm Surgery Using Navigation-CT Angiography

  • Lee, Seung-Hwan;Bang, Jae-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.6
    • /
    • pp.478-480
    • /
    • 2007
  • Unruptured non-traumatic dissecting aneurysm in the M4 segment of the middle cerebral artery (MCA) accompanied by complete occlusion of the ipsilateral internal cerebral artery (ICA) has never been reported. A 41-year-old man presented with an infarction manifesting as left-sided weakness and dysarthria. Magnetic resonance angiography revealed a subacute stage infarction in the right MCA territory and complete occlusion of the right ICA. Angiography demonstrated aneurysmal dilatation of the M4 segment of the right MCA. Surgery was performed to prevent hemorrhage from the aneurysm. The aneurysm was proximally clipped guided by Navigation-CT angiography and flow to the distal MCA was restored by superficial temporal artery-middle cerebral artery (STA-MCA) anastornosis. We report this rare case with literature review.

Image Registration for High-Quality Vessel Visualization in Angiography (혈관조영영상에서 고화질 혈관가시화를 위한 영상정합)

  • Hong, Helen;Lee, Ho;Shin, Yeong-Gil
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.201-206
    • /
    • 2003
  • In clinical practice, CT Angiography is a powerful technique for the visualziation of blood flow in arterial vessels throughout the body. However CT Angiography images of blood vessels anywhere in the body may be fuzzy if the patient moves during the exam. In this paper, we propose a novel technique for removing global motion artifacts in the 3D space. The proposed methods are based on the two key ideas as follows. First, the method involves the extraction of a set of feature points by using a 3D edge detection technique based on image gradient of the mask volume where enhanced vessels cannot be expected to appear, Second, the corresponding set of feature points in the contrast volume are determined by correlation-based registration. The proposed method has been successfully applied to pre- and post-contrast CTA brain dataset. Since the registration for motion correction estimates correlation between feature points extracted from skull area in mask and contrast volume, it offers an accelerated technique to accurately visualize blood vessels of the brain.

  • PDF