• Title/Summary/Keyword: CT Scans

Search Result 583, Processing Time 0.031 seconds

Trastuzumab in a Patient with Metastatic Salivary Duct Carcinoma : A Case Report (트라스투주맙 치료에 반응을 보인 HER2/neu 양성 전이성 타액관 암종 1예)

  • Kong, Bong Han;Lee, Jieun;Choi, Sang-Su;Park, Jinhee;Kim, Yeon Shil;Kim, Min-Sik;Lee, Youn-Soo;Lee, Ji-Yeon;Hong, Sook Hee;Kang, Jin Hyoung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.30 no.2
    • /
    • pp.90-94
    • /
    • 2014
  • Salivary duct carcinoma(SDC) is rare malignancy, accounting for approximately 1-3% of all malignant salivary gland tumors. Systemic chemotherapy has been used for stage IV SDC, but there is no consensus on the standard treatment. SDC is histologically similar to ductal carcinoma of breast and often overexpress HER2/neu, hence HER2/neu targeted therapy could be one of treatment options. A 75-year-old Arabian man was diagnosed as SDC of right parotid gland with extensive metastases. He received oral 5-FU as palliative chemotherapy, but he was intolerable to oral chemotherapy due to severe oral mucositis. Considering immunohistochemical stain of tumor tissue showing strong positive for HER2/neu, we decided to administer an anti-HER2/neu antibody, trastuzumab. Follow-up CT scans before the third dose of trastuzumab demonstrated remarkable regression of multiple metastases as well as primary tumor. This case suggests that HER2/neu targeted therapy may be a potential therapeutic option for the SDC patient with overexpression of HER2/neu.

Ultrasounds Image on the Disorders of the Ligaments Surrounding Temporomandibular Joints (측두하악관절 주변인대 질환의 초음파영상)

  • Hong, Soo-Min;Im, Yeong-Gwan;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2008
  • Purpose : The purpose of this study was to verify the usefulness and feasibility of ultrasonographic imaging for the detection of the disorders of the surrounding supporting structure such as articular capsule, retrodiscal tissue and related ligaments, osteoarthritic evidence and associated disc displacement at the temporomandibular joint(TMJ) Materials and Methods : 20 patients(40 joints) with periodic lock and crepitations were investigated prospectively using 12 MHz array transducer. Ultrasonographic Imagings were assessed for osteoarthritic surface changes of condyle, extent of disc displacement and disorders of surrounding structures. Ultrasonographic images were compared with clinical investigations, conventional radiography and Dental Computed Tomographic scans. Results : In clinical and conventional radiography, osteoarthritic changes were diagnosed in 8 joints. Ultrasonographically 7 of the 8 osteoarthritic changes were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 87.5%, 62.5%, and 67.5% respectively. About the detection of disc displacement, disc displacement were diagnosed in 21 joints clinically. Ultrasonographically 19 of the 21 disc displacements were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 95%, 90%, and 92.5% respectively. when the disorders of supportive structure were figured out, the disorders of supportive structure were diagnosed in 18 joints clinically. Ultrasonographically 1 of the 18 the disorders of supportive structure were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 5.5%, 4.5%, and 55% respectively. Conclusion : Ultrasonography is an relatively reliable diagnostic tool for the detection of disc displacement and some of osteoarthritic changes. But it's not an insufficient imaging technique for the detection of the disorders of the surrounding structure.

Three dimensional analysis of the upper airway and facial morphology in children with Class II malocclusion using cone-beam computed tomography (Cone-beam CT를 이용한 제II급 부정교합 아동의 상기도 형태에 관한 3차원적 연구)

  • Hong, Ji-Suk;Kim, Dae-Sung;Oh, Kyung-Min;Kim, Yoon-Ji;Lee, Kyu-Hong;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.134-144
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the volumes and areas of the upper airways in children with Class II malocclusion, using three dimensional cone-beam computed tomography (CBCT) and to compare the volumetric and cross-sectional measurements and cephalometric variables to investigate possible relationships between the upper airway and facial morphology. Methods: CBCT scans were obtained from 37 subjects (17 boys and 20 girls; average age, 11.02 years). The upper airway volumes and areas were measured, and compared with cephalometric variables. Results: The area of the PNS-posterior plane ($S_{PP}$) was significantly smaller in the Class II malocclusion group (p < 0.05). Also, the volumetric and cross-sectional measurements were lower in Class II than in Class I malocclusion groups, although the differences were not significant between the two groups (p > 0.05). The Class II malocclusion group showed significantly smaller values of PFH, mandibular body length, pog to N perp and showed larger values of FMA, ANB, and facial convexity than the Class I malocclusion group. The volume of the upper airway in front of PNS point (WN) showed negative correlation with ANB (p < 0.05). Conclusions: The Class II malocclusion group had a narrower upper airway associated with a decreased posterior facial height and a divergent growth pattern than the Class I malocclusion group.

Perioperative Orbital Volume Change in Blowout Fracture Correction through Endoscopic Transnasal Approach (안와파열골절의 비강내 내시경적 접근을 통한 교정에서 수술 전후 안와 용적 변화)

  • Lee, Jae Woo;Nam, Su Bong;Choi, Soo Jong;Kang, Cheol Uk;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.617-622
    • /
    • 2009
  • Purpose: Endoscopic transnasal correction of the blowout fractures has many advantages over other techniques. But after removal of packing material, there were some patients with recurrence of preoperative symptoms. Authors tried to make a quantitative anterograde analysis of orbital volume change over whole perioperative period which might be related with recurrence of preoperative symptoms. Methods: 10 patients with pure medial wall fracture(Group I) and 10 patients with medial wall fracture combined with fracture of orbital floor(Group II) were selected to evaluate the final orbital volume change, who took 3 CT scans, pre-, postoperative and 4 months after packing removal. By multiplying cross - section area of orbit in coronal view with section thickness, orbital volume were calculated. Then, mean orbital volume increment after trauma, mean orbital volume decrement after endoscopic correction and volume increment after packing removal were found out. And we tried to find correlations between type of fracture, initial correction rate and final correction rate. Results: The mean orbital volume increment of the fractured orbits were 7.23% in group I and 13.69% in group II. After endoscopic surgery, mean orbital volume decrement were 11.0% in group I and 12.46% in group II. Mean volume increment after packing removal showed 3.10% in group I and 6.50% in group II. The initial correction rate(%) showed linear correlation with final correction rate(%) after packing removal. And there were negative linear correlation between increment percentage of orbital volume by fracture and final correction rate(%). Conclusion: Orbital volume was proved to be increasing after removal of packing or foley catheter and it was dependent upon type of fracture. Overcorrection should be done to improve the final result of orbital blowout fracture especially when there are severe fracture is present.

Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons

  • Ju Gang Nam;Whal Lee;Baren Jeong;Eun-Ah Park;Ji Yeon Lim;Yujin Kwak;Hong-Gook Lim
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.706-713
    • /
    • 2021
  • Objective: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. Materials and Methods: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1-10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. Results: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5-43.5) and 21.4 (17.9-192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2-29.5) and 13.6 (10.3-30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6-17.7) and 8.0 (1.8-170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). Conclusion: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.

Comparison of Radiological Tumor Response Based on iRECIST and RECIST 1.1 in Metastatic Clear-Cell Renal Cell Carcinoma Patients Treated with Programmed Cell Death-1 Inhibitor Therapy

  • Bingjie Zheng;Ji Hoon Shin;Hailiang Li;Yanqiong Chen;Yuan Guo;Meiyun Wang
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.366-375
    • /
    • 2021
  • Objective: To evaluate the radiological tumor response patterns and compare the response assessments based on immune-based therapeutics Response Evaluation Criteria in Solid Tumors (iRECIST) and RECIST 1.1 in metastatic clear-cell renal cell carcinoma (mccRCC) patients treated with programmed cell death-1 (PD-1) inhibitors. Materials and Methods: All mccRCC patients treated with PD-1 inhibitors at Henan Cancer Hospital, China, between January 2018 and April 2019, were retrospectively studied. A total of 30 mccRCC patients (20 males and 10 females; mean age, 55.6 years; age range, 37-79 years) were analyzed. The target lesions were quantified on consecutive CT scans during therapy using iRECIST and RECIST 1.1. The tumor growth rate was calculated before and after therapy initiation. The response patterns were analyzed, and the differences in tumor response assessments of the two criteria were compared. The intra- and inter-observer variabilities of iRECIST and RECIST 1.1 were also analyzed. Results: The objective response rate throughout therapy was 50% (95% confidence interval [CI]: 32.1-67.9) based on iRECIST and 30% (95% CI: 13.6-46.4) based on RECIST 1.1. The time-to-progression (TTP) based on iRECIST was longer than that based on RECIST 1.1 (median TTP: not reached vs. 170 days, p = 0.04). iRECIST and RECIST 1.1 were discordant in 8 cases, which were evaluated as immune-unconfirmed PD based on iRECIST and PD based on RECIST 1.1. Six patients (20%, 6/30) had pseudoprogression based on iRECIST, of which four demonstrated early pseudoprogression and two had delayed pseudoprogression. Significant differences in the tumor response assessments based on the two criteria were observed (p < 0.001). No patients demonstrated hyperprogression during the study period. Conclusion: Our study confirmed that the iRECIST criteria are more capable of capturing immune-related atypical responses during immunotherapy, whereas conventional RECIST 1.1 may underestimate the benefit of PD-1 inhibitors. Pseudoprogression is not rare in mccRCC patients during PD-1 inhibitor therapy, and it may last for more than the recommended maximum of 8 weeks, indicating a limitation of the current strategy for immune response monitoring.

Analysis of the Rate of Discrepancy between Preliminary Reports by Radiology Residents and Final Reports by Certified Radiologists for Emergency Radiology: Studies in a University Hospital (대학병원 응급 영상검사에서 영상의학과 전공의 가판독과 전문의 최종 판독 간의 불일치 발생률 분석)

  • Younbeom Jeong;Cheong-Il Shin;Hwan Jun Jae;Jung Hoon Kim;Jin Wook Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1186-1195
    • /
    • 2021
  • Purpose In the adult emergency department of a university hospital, we investigated the frequency of major discrepancies between the preliminary reports by radiology residents and the final reports by certified radiologists. Materials and Methods Based on CT and MRI scans obtained between December 2016 and November 2019, we selected cases with diagnoses or treatment plans that could be changed due to discrepancies between preliminary and final reports and classified them by the type of discrepancy. We also examined the distributions of the major discrepancies and stratified them by residents' working time zone, experience, and subspecialty. Results Based on the 72137 preliminary reports evaluated, 1348 tests (1.9%) showed major discrepancies. Most of the major discrepancies were false negatives (72.0%), followed by misdiagnosis (26.3%) and false positives (1.7%). Acute findings (87.2%) were more common than non-acute findings (12.8%). The major discrepancy rate increased toward the second half of the 24-hour shift, with the highest rate of 2.9% occurring between 2 am and 4 am. The major discrepancy rate did not vary with experience, and it varied from 0.6% to 4.5% for each subspecialty. Conclusion The major discrepancy rate was less than 2%, and it increased with longer working hours during a 24-hour shift.

Is routine screening examination necessary for detecting thromboembolism in childhood nephrotic syndrome? (소아 신증후군 환자에서 혈전증 검색을 위해screening 검사가 필요한가?)

  • Kim, Mun Sub;Koo, Ja Wook;Kim, Soung Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.7
    • /
    • pp.736-741
    • /
    • 2008
  • Purpose : The incidence of thromboembolic episodes in children with nephrotic syndrome (NS) is low; however, these episodes are often severe. Moreover, both pulmonary thromboembolism (PTE) and renal vein thrombosis (RVT) rarely show clinical symptoms. This study was performed to determine the benefits of routine screening in the detection of thrombosis in childhood NS. Methods : Among 62 children with nephrotic syndrome, a total of 54 children (43 males, 11 females) were included in this study. When the patients experienced their first NS episode, we performed renal Doppler ultrasonography in order to detect RVT. To rule out the possibility of PTE, a lung perfusion scan was performed. Computed tomographic (CT) pulmonary angiography was recommended to patients who showed possible signs of PTE. All patients were evaluated for clinical signs of thrombosis, biochemical indicators of renal disease, as well as clotting and thrombotic parameters. Results : RVT or related clinical symptoms were not observed in any children. Based on the findings of the lung perfusion scans, 15 patients (27.8%) were observed with as a high probability of PTE. We were able to perform a CT pulmonary angiography only on 12 patients, and 5 patients were diagnosed with PTE (prevalence 8.1%). The serum fibrinogen level in the group with PTE was significantly higher ($776.7{\pm}382.4mg/dL$, P<0.05) than that in the group without PTE, and other parameters were not significantly different between each group. Conclusion : Further studies are required for clarifying the role of renal Doppler ultrasonography for the detection of RVT in NS. Children with NS who developed non-specific respiratory symptoms should be evaluated for the diagnosis of PTE. In the management of NS, a lung perfusion scan should be performed at the time of the initial episode of NS regardless of the pulmonary symptoms, since patients having PTE are either often asymptomatic, or present with nonspecific symptoms.

A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF

Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients (사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰)

  • Ahn, Seung-Kwon;Kim, Yong-Bae;Lee, Ik-Jae;Song, Tae-Soo;Son, Dong-Min;Jang, Yung-Jae;Cho, Jung-Hee;Kim, Joo-Ho;Kim, Dong-Wook;Cho, Jae-Ho;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Purpose: We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by $4{\sim}4.4%$ to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume.