• Title/Summary/Keyword: CT Scans

Search Result 552, Processing Time 0.026 seconds

Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis (척추골전이에 있어 F-18 FDG PET/CT에 대한 골스캔의 추가적 역할 및 F-18 FDG PET/CT와 골스캔간에 불일치 병소에 대한 연구)

  • Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju;Kim, Yong-Ki;Kim, Ju-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.218-228
    • /
    • 2008
  • Purpose: Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. Material and Methods: FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). Results: A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p < 0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p = 0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. Conclusion: A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

Impact of Respiratory Phase during Pleural Puncture on Complications in CT-Guided Percutaneous Lung Biopsy (CT 유도 경피 폐생검에서 흉막 천자 시 호흡 시기가 합병증에 미치는 영향)

  • Ji Young Park;Ji-Yeon Han;Seok Jin Choi;Jin Wook Baek;Su Young Yun;Sung Kwang Lee;Ho Young Lee;SungMin Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.566-578
    • /
    • 2024
  • Purpose This study investigated whether the respiratory phase during pleural puncture in CT-guided percutaneous transthoracic needle biopsy (PTNB) affects complications. Materials and Methods We conducted a retrospective review of 477 lung biopsy CT scans performed during free breathing. The respiratory phases during pleural puncture were determined based on the table position of the targeted nodule using CT scans obtained during free breathing. We compared the rates of complications among the inspiratory, mid-, and expiratory respiratory phases. Logistic regression analysis was performed to control confounding factors associated with pneumothorax. Results Among the 477 procedures, pleural puncture was performed during the expiratory phase in 227 (47.6%), during the mid-phase in 108 (22.6%), and during the inspiratory phase in 142 (29.8%). The incidence of pneumothorax was significantly lower in the expiratory puncture group (40/227, 17.6%; p = 0.035) and significantly higher in the mid-phase puncture group (31/108, 28.7%; p = 0.048). After controlling for confounding factors, expiratory-phase puncture was found to be an independent protective factor against pneumothorax (odds ratio = 0.571; 95% confidence interval = 0.360-0.906; p = 0.017). Conclusion Our findings suggest that pleural puncture during the expiratory phase may reduce the risk of pneumothorax during image guided PTNB.

Analyses Using Micro-CT Scans and Tissue Staining on New Bone Formation and Bone Fusion According to the Timing of Cranioplasty via Frozen Autologous Bone Flaps in Rabbits : A Preliminary Report

  • Shin, Hee Sup;Lee, Deok-Won;Lee, Seung Hwan;Koh, Jun Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.242-249
    • /
    • 2015
  • Objective : The timing of cranioplasty and method of bone flap storage are known risk factors of non-union and resorption of bone flaps. In this animal experimental study, we evaluated the efficacy of cranioplasty using frozen autologous bone flap, and examined whether the timing of cranioplasty after craniectomy affects bone fusion and new bone formation. Methods : Total 8 rabbits (male, older than 16 weeks) were divided into two groups of early cranioplasty group (EG, 4 rabbits) and delayed cranioplasty group (DG, 4 rabbits). The rabbits of each group were performed cranioplasty via frozen autologous bone flaps 4 weeks (EG) and 8 weeks (DG) after craniectomy. In order to obtain control data, the cranioplasty immediate after craniectomy were made on the contralateral cranial bone of the rabbits (control group, CG). The bone fusion and new bone formation were evaluated by micro-CT scan and histological examination 8 weeks after cranioplasty on both groups. Results : In the micro-CT scans, the mean values of the volume and the surface of new bone were $50.13{\pm}7.18mm^3$ and $706.23{\pm}77.26mm^2$ in EG, $53.78{\pm}10.86mm^3$ and $726.60{\pm}170.99mm^2$ in DG, and $31.51{\pm}12.84mm^3$ and $436.65{\pm}132.24mm^2$ in CG. In the statistical results, significant differences were shown between EG and CG and between DG and CG (volume : p=0.028 and surface : p=0.008). The histological results confirmed new bone formation in all rabbits. Conclusion : We observed new bone formation on all the frozen autologous bone flaps that was stored within 8 weeks. The timing of cranioplasty may showed no difference of degree of new bone formation. Not only the healing period after cranioplasty but the time interval from craniectomy to cranioplasty could affect the new bone formation.

Clinical Characteristics of Community-Acquired Viridans Streptococcal Pneumonia

  • Choi, Sun Ha;Cha, Seung-Ick;Choi, Keum-Ju;Lim, Jae-Kwang;Seo, Hyewon;Yoo, Seung-Soo;Lee, Jaehee;Lee, Shin-Yup;Kim, Chang-Ho;Park, Jae-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.3
    • /
    • pp.196-202
    • /
    • 2015
  • Background: Viridans streptococci (VS) are a large group of streptococcal bacteria that are causative agents of community-acquired respiratory tract infection. However, data regarding their clinical characteristics are limited. The purpose of the present study was to investigate the clinical and radiologic features of community-acquired pneumonia (CAP) with or without parapneumonic effusion caused by VS. Methods: Of 455 consecutive CAP patients with or without parapneumonic effusion, VS were isolated from the blood or pleural fluid in 27 (VS group, 5.9%) patients. Streptococcus pneumoniae was identified as a single etiologic agent in 70 (control group) patients. We compared various clinical parameters between the VS group and the control group. Results: In univariate analysis, the VS group was characterized by more frequent complicated parapneumonic effusion or empyema and bed-ridden status, lower incidences of productive cough, elevated procalcitonin (>0.5 ng/mL), lower age-adjusted Charlson comorbidity index score, and more frequent ground glass opacity (GGO) or consolidation on computed tomography (CT) scans. Multivariate analysis demonstrated that complicated parapneumonic effusion or empyema, productive cough, bed-ridden status, and GGO or consolidation on CT scans were independent predictors of community-acquired respiratory tract infection caused by VS. Conclusion: CAP caused by VS commonly presents as complicated parapneumonic effusion or empyema. It is characterized by less frequent productive cough, more frequent bed-ridden status, and less common CT pulmonary parenchymal lesions. However, its treatment outcome and clinical course are similar to those of pneumococcal pneumonia.

Matched Comparison of Fusion Rates between Hydroxyapatite Demineralized Bone Matrix and Autograft in Lumbar Interbody Fusion

  • Kim, Dae Hwan;Lee, Nam;Shin, Dong Ah;Yi, Seong;Kim, Keung Nyun;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.363-367
    • /
    • 2016
  • Objective : To compare the fusion rate of a hydroxyapatite demineralized bone matrix (DBM) with post-laminectomy acquired autograft in lumbar interbody fusion surgery and to evaluate the correlation between fusion rate and clinical outcome. Methods : From January 2013 to April 2014, 98 patients underwent lumbar interbody fusion surgery with hydroxyapatite DBM (HA-DBM group) in our institute. Of those patients, 65 received complete CT scans for 12 months postoperatively in order to evaluate fusion status. For comparison with autograft, we selected another 65 patients who underwent lumbar interbody fusion surgery with post-laminectomy acquired autograft (Autograft group) during the same period. Both fusion material groups were matched in terms of age, sex, body mass index (BMI), and bone mineral density (BMD). To evaluate the clinical outcomes, we analyzed the results of visual analogue scale (VAS), Oswestry Disability Index (ODI), and Short Form Health Survey (SF-36). Results : We reviewed the CT scans of 149 fusion levels in 130 patients (HA-DBM group, 75 levels/65 patients; Autograft group, 74 levels/65 patients). Age, sex, BMI, and BMD were not significantly different between the groups (p=0.528, p=0.848, p=0.527, and p=0.610, respectively). The HA-DBM group showed 39 of 75 fused levels (52%), and the Autograft group showed 46 of 74 fused levels (62.2%). This difference was not statistically significant (p=0.21). In the HA-DBM group, older age and low BMD were significantly associated with non-fusion (61.24 vs. 66.68, p=0.027; -1.63 vs. -2.29, p=0.015, respectively). VAS and ODI showed significant improvement after surgery when fusion was successfully achieved in both groups (p=0.004, p=0.002, HA-DBM group; p=0.012, p=0.03, Autograft group). Conclusion : The fusion rates of the hydroxyapatite DBM and Autograft groups were not significantly different. In addition, clinical outcomes were similar between the groups. However, older age and low BMD are risk factors that might induce non-union after surgery with hydroxyapatite DBM.

Nasal Anthropometry on Facial Computed Tomography Scans for Rhinoplasty in Koreans

  • Moon, Kyung Min;Cho, Geon;Sung, Ha Min;Jung, Min Su;Tak, Kyoung Seok;Jung, Sung-Won;Lee, Hoon-Bum;Suh, In Suck
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.610-615
    • /
    • 2013
  • Background Cephalometric analysis is essential for planning treatment in maxillofacial and aesthetic facial surgery. Although photometric analysis of the Korean nose has been attempted in the past, anthropometry of the deeper nasal structures in the same population based on computerized tomography (CT) has not been published. We therefore measured three anthropometric parameters of the nose on CT scans in our clinical series of patients. Methods We conducted the current retrospective study of a total of 100 patients (n=100) who underwent a CT-guided radiological measurement at our institution during a period ranging from January of 2008 to August of 2010. In these patients, we took three anthropometric measurements: the nasofrontal angle, the pyramidal angle, and the linear distance between the nasion and the tip of the nasal bone. Results The mean nasofrontal angle was $131.14^{\circ}$ in the male patients and $140.70^{\circ}$ in the female patients. The mean linear distance between the nasion and the tip of the nasal bone was 21.28 mm and 18.02 mm, respectively. The mean nasal pyramidal angle was $112.89^{\circ}$ and $103.25^{\circ}$ at the level of the nasal root, $117.49^{\circ}$ and $115.60^{\circ}$ at the middle level of the nasal bone, and $127.99^{\circ}$ and $125.04^{\circ}$ at the level of the tip of the nasal bone, respectively. Conclusions In conclusion, our data will be helpful in the preparation of silicone implants for augmentation and/or corrective rhinoplasty in ethnic Korean people.

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.