• Title/Summary/Keyword: CT Images

Search Result 1,782, Processing Time 0.04 seconds

Estimation of CyberKnife Respiratory Tracking System Using Moving Phantom (동적 팬톰을 이용한 사이버나이프 호흡동기 추적장치의 위치 정확성 평가)

  • Seo, Jae-Hyuk;Kang, Young-Nam;Jang, Ji-Sun;Shin, Hun-Joo;Jung, Ji-Young;Choi, Byong-Ock;Choi, Ihl-Bohng;Lee, Dong-Joon;Kwon, Soo-Il;Lim, Jong-Soo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.324-330
    • /
    • 2009
  • In this study, we evaluated accuracy and usefulness of CyberKnife Respiratory Tracking System ($Synchrony^{TM}$, Accuray, USA) about a moving during stereotactic radiosurgery. For this study, we used moving phantom that can move the target. We also used Respiratory Tracking System called Synchrony of the Cyberknife in order to track the moving target. For treatment planning of the moving target, we obtained an image using 4D-CT. To measure dose distribution and point dose at the moving target, ion chamber (0.62 cc) and gafchromic EBT film were used. We compared dose distribution (80% isodose line of prescription dose) of static target to that of moving target in order to evaluate the accuracy of Respiratory Tracking System. We also measured the point dose at the target. The mean difference of synchronization for TLS (target localization system) and Synchrony were $11.5{\pm}3.09\;mm$ for desynchronization and $0.14{\pm}0.08\;mm$ for synchronization. The mean difference between static target plan and moving target plan using 4D CT images was $0.18{\pm}0.06\;mm$. And, the accuracy of Respiratory Tracking System was less 1 mm. Estimation of usefulness in Respiratory Tracking System was $17.39{\pm}0.14\;mm$ for inactivity and $1.37{\pm}0.11\;mm$ for activity. The mean difference of absolute dose was $0.68{\pm}0.38%$ in static target and $1.31{\pm}0.81%$ in moving target. As a conclusion, when we treat about the moving target, we consider that it is important to use 4D-CT and the Respiratory Tracking System. In this study, we confirmed the accuracy and usefulness of Respiratory Tracking System in the Cyberknife.

  • PDF

Comparison of FDG Uptake with Pathological Parameters in the Well-differentiated Thyroid Cancer (분화성 갑상선 암에서 FDG 섭취 정도와 병리학적 지표들과의 비교)

  • Choi, Woo-Hee;Chung, Yong-An;Kim, Ki-Jun;Park, Chang-Suk;Jung, Hyun-Suk;Sohn, Hyung-Sun;Chung, Soo-Kyo;Yoo, Chang-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.40-47
    • /
    • 2009
  • Purpose: Differentiated thyroid cancer (DTC) has variable degree of F-18 FDG avidity. The purpose of this study was to evaluate the relationship between F-18 FDG uptake and pathological or immunohistochemical features of DTC. Materials and Methods: DTC patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included in the study. Maximum standardized uptake values (SUVmax) of primary tumor were calculated. If the primary tumor showed no perceptibly increased F-18 FDG uptake, region of interest was drawn based on finding of a portion of the PET/CT images. Pathological and immunohistochemical markers such as presence of lymph node (LN) metastasis and underlying thyroiditis, tumor size, Ki-67 labeling index, expressions of EGFR, COX-2, and Galectin-3 were evaluated. Results: Total of 106 patients was included (102 papillary carcinomas, 4 follicular carcinomas). The mean SUVmax of the large tumors (above 1 cm) was significantly higher than the mean SUVmax of small (equal to or less than 1 cm) ones ($7.8{\pm}8.5$ vs. $3.6{\pm}3.1$, p=0.004). No significant difference in F-18 FDG uptake was found according to the presence or absence of LN metastasis and underlying thyroiditis, or the degree of Ki-67 labeling index, expression of EGFR, COX- 2 and Galectin-3. Conclusion: In conclusion, the degree of F-18 FDG uptake in DTC was associated with the size of primary tumor. But there seem to be no relationship between F-18 FDG uptake of DTC and expression of Ki-67, EGFR, COX-2 and Galectin-3.

Relationship between inter-condylar width and inter-maxillary first molar width (과두간 폭경과 상악 제1대구치간 폭경 사이의 관계)

  • Oh, Sang-Chun;Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.214-219
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the correlation between inter-condylar width and inter-maxillary first molar width to present the criteria for prosthetic reconstruction of dental arch width in maxillary and mandibular fully edentulous patients. Materials and Methods: 120 Koreans (60 males and 60 females) who underwent the cone beam computerized tomography (Cone-beam CT) were selected. The Cone-beam CT images were analysed using Invivo 5.1. After reorientation of axis, inter-maxillary first molar width was measured by clicking both mesio-buccal cusp tip of maxillary first molar. And inter-condylar width was measured by clicking both middle points of condyles. The collected data were analysed with SPSS Version 20.0 and statistical significance of the correlation between inter-condylar width and inter-maxillary first molar width was verified by Pearson's correlation analysis. Results: The mean inter-condylar width of Korean was 105.9 mm, and that of male (108.3 mm) was statistically significantly wider than the female (103.4 mm). The inter-maxillary first molar width of Korean was 57.1 mm, and that of male (57.9 mm) was statistically significantly wider than the female (56.2 mm). Pearson's correlation analysis between inter-condylar width and inter-maxillary first molar width showed a Pearson correlation coefficient of 0.614 and statistically significantly positive correlation. Conclusion: Intercondylar width and inter-maxillary first molar width showed positive correlation and the average ratio of inter-condylar with and inter-maxillary first molar width was 1:0.54. Based on the results of this limited study, inter-condylar width can be used as a guide for setting up dental arch width in fully edentulous patient.

Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network (멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용)

  • Tae Jun Ha;Hee Sang Kim;Seong Uk Kang;DooHee Lee;Woo Jin Kim;Ki Won Moon;Hyun-Soo Choi;Jeong Hyun Kim;Yoon Kim;So Hyeon Bak;Sang Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.187-201
    • /
    • 2024
  • Osteoporosis is a major health issue globally, often remaining undetected until a fracture occurs. To facilitate early detection, deep learning (DL) models were developed to classify osteoporosis using abdominal computed tomography (CT) scans. This study was conducted using retrospectively collected data from 3,012 contrast-enhanced abdominal CT scans. The DL models developed in this study were constructed for using image data, demographic/clinical information, and multi-modality data, respectively. Patients were categorized into the normal, osteopenia, and osteoporosis groups based on their T-scores, obtained from dual-energy X-ray absorptiometry, into normal, osteopenia, and osteoporosis groups. The models showed high accuracy and effectiveness, with the combined data model performing the best, achieving an area under the receiver operating characteristic curve of 0.94 and an accuracy of 0.80. The image-based model also performed well, while the demographic data model had lower accuracy and effectiveness. In addition, the DL model was interpreted by gradient-weighted class activation mapping (Grad-CAM) to highlight clinically relevant features in the images, revealing the femoral neck as a common site for fractures. The study shows that DL can accurately identify osteoporosis stages from clinical data, indicating the potential of abdominal CT scans in early osteoporosis detection and reducing fracture risks with prompt treatment.

Leiomyosarcoma of the Mandible : Report of a Case (하악골에 발생한 평활근육종)

  • Lee Jean;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.549-559
    • /
    • 1999
  • Leiomyosarcoma is extremely rare in the oral cavity and especially in the mandible. At first. the case of this report was diagnosed as odontogenic fibroma but after approximately 3.5 years. it was diagnosed as leiomyosarcoma. Conventional radiograph of the first time showed an ill-defined radiolucent lesion in the mandible. After local recurrence. CT images showed a large irregular soft tissue mass with some necrotic areas. These findings were not specific for leiomyosarcoma, but they suggested that this lesion was a recurrent soft tissue sarcoma. Histopathological examinations using H & E staining, immunohistochemical staining and Masson's trichrome staining confirmed this case as leiomyosarcoma. Deciding its malignancy or benignancy, defining the tumor extent and its relationship to the surrounding anatomic structures, and evaluating the distant metastasis are more important roles of radiographic examination than finding out the name of disease.

  • PDF

Segmentation and 3D Visualization of Medical Image : An Overview

  • Kang, Jiwoo;Kim, Doyoung;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • In this paper, an overview of segmentation and 3D visualization methods are presented. Commonly, the two kinds of methods are used to visualize organs and vessels into 3D from medical images such as CT(A) and MRI - Direct Volume Rendering (DVR) and Iso-surface Rendering (IR). DVR can be applied directly to a volume. It directly penetrates through the volume while it determines which voxels are visualizedbased on a transfer function. On the other hand, IR requires a series of processes such as segmentation, polygonization and visualization. To extract a region of interest (ROI) from the medical volume image via the segmentation, some regions of an object and a background are required, which are typically obtained from the user. To visualize the extracted regions, the boundary points of the regions should be polygonized. In other words, the boundary surface composed of polygons such as a triangle and a rectangle should be required to visualize the regions into 3D because illumination effects, which makes the object shaded and seen in 3D, cannot be applied directly to the points.

Radiological and acoustic characteristics of "Arae-a" (/ㆍ/) articulation in Jeju language speakers (제주어 화자에서 '아래 아'(/ㆍ/) 조음의 영상의학적 및 음향학적 특성)

  • Lee, Seung Jin;Choi, Hong-Shik
    • Phonetics and Speech Sciences
    • /
    • v.10 no.1
    • /
    • pp.57-64
    • /
    • 2018
  • The purpose of the present study was to explore the radiological and acoustic characteristics of "Arae-a" (/${\cdot}$/) articulation in two male Jeju language speakers, focusing on selected measures in radiological images derived from computed tomography scans, as well as the first and the second formant measures in selected vowels. An elderly male speaker (a 78-year-old) and a young male speaker (a 34-year-old) participated in the study. During the production of four selected vowels, the shape of the vocal tract was identified, and selected measures were obtained from the elderly participant's computed tomography (CT) scans. For acoustic analysis, the participants were given a list of near-minimal pairs consisting of 112 words and asked to read them aloud. The results indicated that the "Arae-a" (/${\cdot}$/) articulation of the elderly speaker showed unique acoustic and radiological characteristics compared to other similar vowels, thus presenting substantial consistency with the descriptions of the "Hunminjeongeum Haeryebon." In contrast, the F1 and F2 measures of the young male's /${\cdot}$/ articulation were not distinguished from those of /ㅗ/. Current results, in part, support the scientific principles underlying the invention of "Arae-a," which reflects the shape of the vocal tract during production, and the necessity for further research.

Analysis on Setup Variation According to Megavoltage Computed Tomography System

  • Kim, Sun-Yung;Kim, Hwa-Sun;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.425-430
    • /
    • 2016
  • The aim of this study was to measure the setup variation for X (lateral), Y (longitude), and Z (vertical) by taking magnetic megavoltage computed tomography (MVCT) before treating the brain, oropharynx, lung, and prostate patients on helical tomotherapy. In this study, 30 patients were chosen for each of the treatment areas, and their skin was labeled with a mark on a treatment planning reference point when taking CT. We preceded MVCT prior to tomotherapy and then conducted an auto registration based on the bony landmarks; image registration was used for automatically matching the patient's setup. Lastly, we confirmed and evaluated the translation coordinates of the images for 30 patients. The following shows the comparison result of the setup errors of each part: X (lateral) showed the highest setup errors with $3.44{\pm}2.05$ from Lung; Y (longitude) showed the highest setup errors showing $3.40{\pm}2.87mm$ from Prostate; and Z (vertical) showed the highest setup errors showing $6.62{\pm}4.38mm$ from Lung. This result verifies that the setup error can be prevented by taking MVCT before the treatment, and Planning Target Volume (PTV) margins can be reduced by referring to the resulting value of each treatment part. Ultimately, the dosage of the normal organs can be decreased as well as any side effects.

Analysis of Isometry of the Anterior Cruciate Ligament for Optimal Ligament Reconstruction (전방십자인대의 최적 재건을 위한 등장성 해석)

  • Park Jung-Hong;Suh Jeung-Tak;Moon Byung-Young;Son Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.457-464
    • /
    • 2006
  • The anterior cruciate ligament (ACL) is liable to a major injury that often results in a functional impairment requiring surgical reconstruction. The success of reconstruction depends on such factors as attachment positions, initial tension of ligament and surgical methods of fixation. The purpose of this study is to find isometric positions of the substitute during flexion/extension. The distance between selected attachments on the femur and tibia was computed from a set of measurements using a 6 degree-of-freedom magnetic sensor system. A three-dimensional knee model was constructed from CT images and was used to simulate length change during knee flexion/extension. This model was scaled for each subject. Twenty seven points on the tibia model and forty two points on the femur model were selected to calculate length change. This study determined the maximum and minimum distances to the tibial attachment during flexion/extension. The results showed that minimum length changes were $1.9{\sim}5.8mm$ (average $3.6{\pm}1.4mm$). The most isometric region was both the posterosuperior and anterior-diagonal areas from the over-the-top. The proposed method can be utilized and applied to an optimal reconstruction of ACL deficient knees.

Lymphangioma of the Head and Neck: Report of 4 Cases (두경부 림프관종의 증례보고)

  • Jeong Yeon-Hwa;Cho Bong-Hae;Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.87-91
    • /
    • 2000
  • Lymphangiomas are uncommon benign congenital tumors. Most occur in the head and neck and most lesions present by the age of 2 years. We present our experience with four patients who have lymphangiomas of the head and neck with tongue involvement. First case is a 7-year-old male who has the cystic lymphangioma of left submandibular area. Second a 22-year-old female has a lesion involving the border of right tongue. Third case is the lymphangioma which occurs in the right upper lip of a 6-year old male. The last patient is a 28-year old male who fell down and whose right face was swollen up. He had undergone an operation and been treated with steroid before. The characteristic appearances of imaging methods were described and all lesions best depicted on T2-weighted images. Our experience indicates that MRI is useful in the diagnosis and treatment planning of lymphangioma.

  • PDF