• Title/Summary/Keyword: CT Images

Search Result 1,782, Processing Time 0.033 seconds

Implementation of PACS using PDA System on Medical Images (PDA기반 의료영상의 전송시스템 구현)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2009
  • PACS(Picture archiving communication system) is a system that enables medical images such as X -ray, CT, MRI, PET to be stored electronically viewed on computer screens so that doctors and other authorized people can access search the information as needed. But if they are not in hospital area for example on holiday or at night, that are not able to access the PACS system instantly. We have to solve this problem for more efficient patient care. So we try to suggest a method that use the PDA system that wireless LAN and CDMA cellular phone are equipped. This system may help to access easier to PACS system regardless of the location and can also attribute the development of telemedicne.

CT and MRI Findings of Small Bowel Involvement of Amyloidosis Mimicking Small Bowel Polyposis Syndrome: a Case Report

  • Kang, Dong Min;Lee, Young Hwan;Kim, Youe Ree;Yoon, Kwon-Ha;Yun, Ki Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.2
    • /
    • pp.85-89
    • /
    • 2020
  • Amyloidosis is an all-inclusive disease of deposition of amyloid proteins in the extracellular spaces, which in localized or systemic form cause tissue damage and dysfunction. Herein, we report a case of small bowel involvement of systemic amyloidosis presenting with multiple polypoid wall thickening mimicking small bowel polyposis syndrome in an age 75 male. Interestingly, polypoid wall thickening and amyloidoma showed hypointensity on T2-weighted images. To our knowledge, there has been no literature describing MRI findings of poylpoid wall thickening and amyloidoma. Although the underlying mechanisms are unclear and need validation, hypointensity on T2-weighted images could be valuable in diagnosing small bowel involvement of amyloidosis in patients presenting with poylpoid wall thickening and amyloidoma.

Object-Oriented Stereotactic Radiosurgery Planning System (객체 지향 개념을 이용한 뇌정위 방사선 수술 계획 시스템)

  • Park, S.H.;Suh, T.S.;Suh, D.Y.;Kang, W.S.;Ha, S.H.;Kim, I.H.;Park, C.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.85-87
    • /
    • 1994
  • In this paper, we present an object-oriented stereotactic radiosurgery planning system, which accepts medical images such as CT and angiography, transforms the coordinates to a reference frame coordinate, calculates dose distributions, and finally displays isodose curves over the images. The user finds an adequate one for radiosurgeries after performing computer simulations on different treatment parameter sets. The object-oriented design concept was fully applied to the system composed of seven manager objects of different classes: a patient information manager, a user-interface manager, a coordinate transformation manager, a blackboard manager, a dose calculation manager, an isodose curve display manager, and a report manager. All the user interactions are carried out through the use of mouse buttons. The performance of the system was verified by four physicians and two medical physicists, and now is being used in two clinical sites.

  • PDF

A New Approximate DCT Computation Based on Subband Decomposition and Its Application (서브밴드 분리에 근거한 새로운 근사 DCT 계산과 응용)

  • Jeong, Seong-Hwan
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.5
    • /
    • pp.1329-1336
    • /
    • 1996
  • In many image compression applications, the discrete cosine transform (DCY) is well known for is highly efficient coding performance. However, it produces undesirable block artifacts in low-bit rate coding. In addition, in many practical applications, faster computation and easier VLST implementation of DCT coefficients are also important issues. The removal of the block artifacts and faster DCT computation are therefor of practical interest. In this paper, a modified DCTcomputation scheme was investigated, which provides a simple efficient solution to the reduction of the block artifacts while achieving faster computation. We have applied the new ap-proach to the low-bit rate coding and decoding of images. Simulation results on real images have verified the improved performance of the proposed method over the standar d method.

  • PDF

The Globular Cluster System of the Virgo Giant Elliptical Galaxy NGC 4636

  • Park, Hong-Soo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.55.2-55.2
    • /
    • 2010
  • We present a photometric and spectroscopic study of the globular clusters (GCs) in the giant elliptical galaxy NGC 4636 in the Virgo cluster. The photometry of the GCs is based on HST/WFPC2 images for the inner region and deep, wide field Washington $CT_1$ CCD images for the outer region. We investigated the color distribution, the radial number density profile, the spatial distribution, and the mean color of the bright blue GCs about the GCs in NGC 4636. We obtained spectra of the GC candidates in NGC 4636 using the Multi-Object Spectroscopy (MOS) mode of Faint Object Camera and Spectrograph (FOCAS) on the SUBARU 8.2m Telescope. We measured the velocities for 105 GCs in NGC 4636. Using the 238 GCs obtained from combining our results with data in the literature, we investigated the kinematics of the GC system of NGC 4636: the rotation, the velocity dispersion, the radial variation, and the orbit. We also investigated the distribution and the radial variation of the metallicities, ages, and alpha-elements of the GCs in NGC 4636 derived using the absorption lines. We compared the GC kinematics of NGC 4636 with those of other six gEs, finding that the kinematic properties of the GCs are diverse among gEs. We found several correlations between the kinematics of the GCs and the global parameters of their host galaxies. Finally we discuss the implication of the results for the formation models of the GC system in gEs, and suggest a mixture scenario for the origin of the GCs in gEs.

  • PDF

A Design and Implementation of Image Maintenance Using Base on Grid of the Decentralized Storage System (GRID 기반의 분산형 의료영상 저장시스템 설계 및 구현)

  • Kim, Sun-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Modern hospitals have been greatly facilitated with information technology (IT) such as hospital information system (HIS). One of the most prominent achievements is medical imaging and image data management so-called Picture Archiving and Communication Systems (PACS). Due to inevitable use of diagnostic images (such as X-ray, CT, MRI), PACS made tremendous impact not only on radiology department but also nearly all clinical departments for exchange and sharing image related clinical information. There is no doubt that better use of PACS leads to highly efficient clinical administration and hospital management. However, due to rapid and widespread acceptance of PACS storage and management of digitized image data in hospital introduces overhead and bottleneck when transferring images among clinical departments within and/or across hospitals. Despite numerous technical difficulties, financing for installing PACS is a major hindrance to overcome. In addition, a mirroring or a clustering backup can be used to maximize security and efficiency, which may not be considered as cost-effective approach because of extra hardware expenses. In this study therefore we have developed a new based on grid of distributed PACS in order to balance between the cost and network performance among multiple hospitals.

  • PDF

Visualization of Delayed Gastric Emptying Flows After Esophageal Reconstruction Using a Gastric Graft (위장 이식편을 이용한 식도 재건술에서 위장 배출 지연 현상의 가시화)

  • Jeon, Hye-Jin;Park, Hee-Jin;Sung, Jae-Yong;Lee, Jae-Ik
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.22-27
    • /
    • 2010
  • The delayed gastric emptying flows have been visualized in this study when a gastric graft replaced an esophagus after esophagectomy. To construct visualization models for gastric grafts, the path data of gastric graft were extracted from the CT images for real patients and then the experimental models were made from silicone tube by considering elasticity of real stomach. During experiments, 200 ml of water or glycerin was poured into the gastric graft model and the gastric emptying time for total volume of fluid to pass pylorus was measured from the successive images captured by a high speed CCD. The gastric emptying time was compared according to the change of diameter and path (front or rear path) of gastric graft, and pyloroplasty or not. In case that the pyloroplasty was not conducted, the smaller was the diameter of gastric graft, the shorter was the gastric emptying time. However, if the pyloroplasty was conducted, the larger diameter of gastric graft was better for the gastric emptying. Although the rear path gave rise to longer gastric emptying time than the front path, it did not matter, if the pyloroplasty was conducted.

Application of radiographic images in diagnosis and treatment of deep neck infections with necrotizing fasciitis: a case report

  • Kim, Young-Joo;Kim, Ju-Dong;Ryu, Hye-In;Cho, Yeon-Hee;Kong, Jun-Ha;Ohe, Joo-Young;Kwon, Yong-Dae;Choi, Byung-Joon;Kim, Gyu-Tae
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.189-193
    • /
    • 2011
  • The advent and wide use of antibiotics have decreased the incidence of deep neck infection. When a deep neck infection does occur, however, it can be the cause of significant morbidity and death, resulting in airway obstruction, mediastinitis, pericarditis, epidural abscesses, and major vessel erosion. In our clinic, a patient with diffuse chronic osteomyelitis of mandible and fascial space abscess and necrotic fasciitis due to odontogenic infection at the time of first visit came. We successfully treated the patient by early diagnosis using contrast-enhanced CT and follow up dressing through the appropriate use of radiographic images.

Development of Computer Aided 3D Model From Computed Tomography Images and its Finite Element Analysis for Lumbar Interbody Fusion with Instrumentation

  • Deoghare, Ashish;Padole, Pramod
    • International Journal of CAD/CAM
    • /
    • v.9 no.1
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to clarify the mechanical behavior of human lumbar vertebrae (L3/L4) with and without fusion bone under physiological axial compression. The author has developed the program code to build the patient specific three-dimensional geometric model from the computed tomography (CT) images. The developed three-dimensional model provides the necessary information to the physicians and surgeons to visually interact with the model and if needed, plan the way of surgery in advance. The processed data of the model is versatile and compatible with the commercial computer aided design (CAD), finite element analysis (FEA) software and rapid prototyping technology. The actual physical model is manufactured using rapid prototyping technique to confirm the executable competence of the processed data from the developed program code. The patient specific model of L3/L4 vertebrae is analyzed under compressive loading condition by the FEA approach. By varying the spacer position and fusion bone with and without pedicle instrumentation, simulations were carried out to find the increasing axial stiffness so as to ensure the success of fusion technique. The finding was helpful in positioning the fusion bone graft and to predict the mechanical stress and deformation of body organ indicating the critical section.

Effects of Physical Factors on Computed Tomography Image Quality

  • Jeon, Min-Cheol;Han, Man-Seok;Jang, Jae-Uk;Kim, Dong-Young
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of X-ray photon energy, tissue density, and the kernel essential for image reconstruction on the image quality by measuring HU and noise. Images were obtained by scanning the RMI density phantom within the CT device, and HU and noise were measured as follows: images were obtained by varying the tube voltages, the tube currents and eight different kernels. The greater the voltage-dependent change in the HU value but the noise was decreased. At all densities, changes in the tube current did not exert any significant influence on the HU value, whereas the noise value gradually decreased as the tube current increased. At all densities, changes in the kernel did not exert any significant influence on the HU value. The noise value gradually increased in the lower kernel range, but rapidly increased in the higher kernel range. HU is influenced by voltage and density, and noise is influenced by voltage, current, kernel, and density. This affects contrast resolution and spatial resolution.