• 제목/요약/키워드: CT Image Normalization

검색결과 9건 처리시간 0.021초

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

CT영상에서 개별 치아 분리를 위한 적응 최적 임계화 방안 (Adaptive Optimal Thresholding for the Segmentation of Individual Tooth from CT Images)

  • 허훈;채옥삼
    • 대한전자공학회논문지SP
    • /
    • 제41권3호
    • /
    • pp.163-174
    • /
    • 2004
  • 치과 분야에서는 치아교정이나 수술 시뮬레이션을 위해서 각 치아를 개별적으로 조작할 수 있는 3차원 치아모델이 필요하다. 치아 CT 영상으로부터 이러한 치아모델의 재구성을 위해서는 각 치아를 이웃한 치아나 치조골로부터 정확하게 분리할 수 있어야 한다. 본 연구에서는 치아 영역을 효과적으로 분리하기 위한 영상정규화 방안과 최적임계화방안을 제안한다. 제안된 방법은 연속적인 CT 영상 슬라이스들에서 치아영역의 형태와 밝기는 점진적으로 변한다는 사실을 근거로 이전 슬라이스에서 추정된 임계치를 이용하여 현 슬라이스의 임시치아경계를 결정하고 이것을 바탕으로 보다 정확한 임계치를 계산한다.

흉부 컴퓨터 단층 촬영에서 정규화를 사용한 다양한 히스토그램 평준화 기법을 비교 (Comparison of Based on Histogram Equalization Techniques by Using Normalization in Thoracic Computed Tomography)

  • 이영준;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.473-480
    • /
    • 2021
  • This study was purpose to method that applies for improving the image quality in CT and X-ray scan, especially in the lung region. Also, we researched the parameters of the image before and after applying for Histogram Equalization (HE) such as mean, median values in the histogram. These techniques are mainly used for all type of medical images such as for Chest X-ray, Low-Dose Computed Tomography (CT). These are also used to intensify tiny anatomies like vessels, lung nodules, airways and pulmonary fissures. The proposed techniques consist of two main steps using the MATLAB software (R2021a). First, the technique should apply for the process of normalization for improving the basic image more correctly. In the next, the technique actively rearranges the intensity of the image contrast. Second, the Contrast Limited Adaptive Histogram Equalization (CLAHE) method was used for enhancing small details, textures and local contrast of the image. As a result, this paper shows the modern and improved techniques of HE and some advantages of the technique on the traditional HE. Therefore, this paper concludes that various techniques related to the HE can be helpful for many processes, especially image pre-processing for Machine Learning (ML), Deep Learning (DL).

X-ray micro-CT 이미지 내 패임 및 동심원상 화상결함 제거를 위한 이미지 보정 기법 (Image Calibration Techniques for Removing Cupping and Ring Artifacts in X-ray Micro-CT Images)

  • 정연종;윤태섭;김광염;주진현
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.93-101
    • /
    • 2011
  • X-ray micro-CT를 이용한 지반재료 내부 미세구조 및 공극구조의 정밀한 이미지 처리는 종종 이미지 내에 원천적으로 포함되는 화상결함으로 인해 제약된다. 본 논문에서는 X-ray micro-CT 이미지에 가장 일반적으로 나타나는 화상결함인 패임(영상 외곽과 중심부의 명암 차이) 및 동심원상(영상 중심으로부터 방사방향으로 연속적으로 나타나는 원)을 제거할 수 있는 이미지 보정 기법을 제시한다. 결함 제거는 좌표 변환법, 정규화 및 2차원 푸리에 변환에 의한 저역 통과 필터링 기법의 순차적 적용을 통해 이루어진다. 이미지 처리 기법의 효과를 다공성 현무암의 CT 이미지에서 화상결함들을 제거하고 이진화 후 적층하여 3차원 공극 구조를 추출하는 과정을 통해 설명하였다. 패임 및 동심원상 결함을 제거한 이미지와 원본 이미지의 비교 결과 결함 제거는 대상 재료 공극률의 과대평가를 방지할 수 있으며, 따라서 화상결함의 적절한 보정은 X-ray CT의 지반재료 적용 시 필수적인 과정으로 판단된다.

컴퓨터 단층영상에서 사이노그램 정규화를 이용한 금속 영상왜곡 저감 방법의 이론적 고찰 (Theoretical Investigation of Metal Artifact Reduction Based on Sinogram Normalization in Computed Tomography)

  • 전호상;윤한빈;남지호;김호경
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.303-314
    • /
    • 2013
  • 금속 인공물을 포함한 인체 단층영상의 경우 금속 영상왜곡으로 인한 화질의 저하가 매우 심각하다. 금속 영상왜곡 저감을 위한 많은 방법 중 사이노그램 정규화를 통해 평탄한 사이노그램을 제공하여 금속 궤적을 쉽게 찾고, 단순 선형 보간으로 금속물을 대체하는 두께 및 배경 정규화 방법이 최근 소개되었다. 본 연구에서는 두 방법의 이론적 배경을 개발하였으며, 시뮬레이션을 통해 금속 인공 물질의 크기 및 개수에 따른 두 방법의 보정 결과를 비교하였다. 개발한 이론에 의하면 배경 정규화 방법이 두께 정규화 방법에 비해 피검사체 배경 구성 물질의 개수 및 종류에 상관없이 거의 평탄한 사이노그램을 제공하였으며, 시뮬레이션을 통해 이를 증명하였다. 금속 인공 물질의 다양한 크기 및 개수에 대한 두 방법의 보정 결과 역시 배경 정규화 방법이 두께 정규화 방법에 비해 훨씬 나은 보정 결과를 보여 주었다. 배경 정규화 방법은 영상분할 과정을 요구하는데 본 연구에서는 이 과정을 생략하더라도 비록 영상왜곡 잔상이 미약하게 나타나긴 하지만, 두께 정규화 방법에 비해 훨씬 나은 보정 결과를 제공함을 확인하였다. 영상분할 과정을 생략한 배경 정규화 방법은 매우 간단하며 단순 선형 보간으로도 금속 궤적에 의해 손실된 데이터의 기술이 충분하고, 또한 사용자의 개입이 없는 알고리즘화가 가능하기 때문에 기존 컴퓨터단층영상 시스템에 쉽게 탑재되어 활용될 수 있을 것으로 기대된다.

Low-dose CT Image Denoising Using Classification Densely Connected Residual Network

  • Ming, Jun;Yi, Benshun;Zhang, Yungang;Li, Huixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권6호
    • /
    • pp.2480-2496
    • /
    • 2020
  • Considering that high-dose X-ray radiation during CT scans may bring potential risks to patients, in the medical imaging industry there has been increasing emphasis on low-dose CT. Due to complex statistical characteristics of noise found in low-dose CT images, many traditional methods are difficult to preserve structural details effectively while suppressing noise and artifacts. Inspired by the deep learning techniques, we propose a densely connected residual network (DCRN) for low-dose CT image noise cancelation, which combines the ideas of dense connection with residual learning. On one hand, dense connection maximizes information flow between layers in the network, which is beneficial to maintain structural details when denoising images. On the other hand, residual learning paired with batch normalization would allow for decreased training speed and better noise reduction performance in images. The experiments are performed on the 100 CT images selected from a public medical dataset-TCIA(The Cancer Imaging Archive). Compared with the other three competitive denoising algorithms, both subjective visual effect and objective evaluation indexes which include PSNR, RMSE, MAE and SSIM show that the proposed network can improve LDCT images quality more effectively while maintaining a low computational cost. In the objective evaluation indexes, the highest PSNR 33.67, RMSE 5.659, MAE 1.965 and SSIM 0.9434 are achieved by the proposed method. Especially for RMSE, compare with the best performing algorithm in the comparison algorithms, the proposed network increases it by 7 percentage points.

Efficient Semi-automatic Annotation System based on Deep Learning

  • Hyunseok Lee;Hwa Hui Shin;Soohoon Maeng;Dae Gwan Kim;Hyojeong Moon
    • 대한임베디드공학회논문지
    • /
    • 제18권6호
    • /
    • pp.267-275
    • /
    • 2023
  • This paper presents the development of specialized software for annotating volume-of-interest on 18F-FDG PET/CT images with the goal of facilitating the studies and diagnosis of head and neck cancer (HNC). To achieve an efficient annotation process, we employed the SE-Norm-Residual Layer-based U-Net model. This model exhibited outstanding proficiency to segment cancerous regions within 18F-FDG PET/CT scans of HNC cases. Manual annotation function was also integrated, allowing researchers and clinicians to validate and refine annotations based on dataset characteristics. Workspace has a display with fusion of both PET and CT images, providing enhance user convenience through simultaneous visualization. The performance of deeplearning model was validated using a Hecktor 2021 dataset, and subsequently developed semi-automatic annotation functionalities. We began by performing image preprocessing including resampling, normalization, and co-registration, followed by an evaluation of the deep learning model performance. This model was integrated into the software, serving as an initial automatic segmentation step. Users can manually refine pre-segmented regions to correct false positives and false negatives. Annotation images are subsequently saved along with their corresponding 18F-FDG PET/CT fusion images, enabling their application across various domains. In this study, we developed a semi-automatic annotation software designed for efficiently generating annotated lesion images, with applications in HNC research and diagnosis. The findings indicated that this software surpasses conventional tools, particularly in the context of HNC-specific annotation with 18F-FDG PET/CT data. Consequently, developed software offers a robust solution for producing annotated datasets, driving advances in the studies and diagnosis of HNC.

프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구 (Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System)

  • 손준영;최성훈;이동훈;김희중
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.111-118
    • /
    • 2019
  • 흉부 디지털 단층영상합성장치는 기존 DR의 낮은 깊이 해상도, CT의 높은 피폭선량 문제를 해결할 수 있는 획기적인 영상장치로 대두되고 있다. 그러나 제한된 스캔 각도로 인해 프로젝션이 X 선 소스 동작 방향으로 흉부를 완전히 포함 할 수 없어 재구성 된 슬라이스의 위, 아래 방향 경계를 따라 강도의 불연속성이 발생하게 되는데 이러한 현상을 잘림 아티팩트 (Truncation artifact)라고 한다. 이 연구의 목적은 가중 정규화 접근법을 사용하여 잘림 아티팩트를 줄이고 리스템에서 개발한 프로토 타입 흉부 디지털 단층영상합성장치 시스템에 대한 이 접근법의 성능을 평가하는 것이다. 이 시스템의 source-to-image distance는 1100 mm 이고 X 선원의 회전 중심은 검출기 표면에서 100mm 위로 설정되었다. LUNGMAN 팬텀을 사용하여 ${\pm}20^{\circ}$의 투영 뷰를 $1^{\circ}$ 간격으로 41장을 얻은 후, filtered back projection 알고리즘으로 재구성했다. 정량적 평가를 위하여 시뮬레이션을 이용하여 기준영상을 재구성 후 peak signal to noise ratio와 structure similarity index 값을 평가하였으며 실제 실험 데이터를 이용하여 mean value of specific direction 값을 평가하였다. 시뮬레이션 결과로 아티팩트 보정 전 일반적인 filtered back projection 알고리즘으로 재구성 한 영상과 비교하여 peak signal to noise ratio값과 structure similarity index값 모두 각각 증가하였으며, 실제 실험 재구성 영상의 mean value of specific direction 결과는 아티팩트의 영향이 감소됨을 확인할 수 있었다. 결론적으로, 가중 정규화 방법은 잘림 아티팩트를 줄임으로써 진단의 어려움을 발생시키는 가능성을 개선시킬 수 있는 방법으로 사료된다.

주성분분석을 이용한 C[11]-PIB imaging 영상분석 (Principal component analysis in C[11]-PIB imaging)

  • 김남범;신귀순;안성민
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.12-16
    • /
    • 2015
  • 주성분분석(Principal component analysis, PCA)은 고차원 변수들 사이의 복잡한 상관성 구조를 더 낮은 차원으로 단순화하여 상관성의 구조를 쉽게 설명하기 위한 다변량분석기법으로 뇌영상 분석에서 자주 사용되는 방법이다. 주성분분석의 기본개념은 서로 직교하는 변수들의 선형결합을 통해서 원래의 뇌영상 자료가 가지고 있는 전체정보를 최대한 설명할 수 있는 서로 독립적인 새로운 변수들을 유도하는 것이다. 뇌영상분석에서 주성분분석의 효율성과 유용성을 알아보기 위해서 C[11]-PIB 영상을 이용하여 분석하였다. 대상 및 방법으로는 평균나이가 같은 9명의 정상인, 10명의 알츠하이머/경도인지장애환자들의 C[11]-PIB 영상을 이용하였다. PET-CT 장비로는 Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN)를 영상을 획득하였고 9.6 MBq/kg C[11]-PIB를 정맥주사 한 후 40분 후에 20분 동안 3D acquisition mode로 방출영상을 얻었다. Attenuation map은 X-ray CT scan을 이용하여 재구성하였다(130 kVp, 240 mA). PIB template을 만들기 위해서 정상인에서 3T MRI T1-weighted 영상을 동시에 얻었다. 주성분분석을 위한전처리과정으로서 공간정규화 및 공간편평화를 SPM8을 이용하여 실시하였고 주성분분석은 Matlab2012b를 이용하여 분석하다. 결과는 주성분분석을 통해서 서로 독립적인 주성분영상들을 얻을 수 있었다. 주성분분석을 통해서 얻어진주성분영상은 C[11]-PIB brain PET 영상의 패턴을 몇 개의 주성분으로 단순화 할 수 있었으며 주로는 neocortex를 변동 나타내는 영상, white matter의 변동을 나타내는 영상 그리고 pons등 deep brain의 변동을 나타내는 영상 등으로 단순화되었다. 결론으로는 주성분분석은 C[11]-PIB brain 영상을 단순화하여 영상의 패턴을 해석하는데 매우 유용하였다. 이러한 주성분분석은C[11]-PIB영상 분석뿐만 아니라 뇌의 포도당 대사를 측정하는 FDG-PET 또는 뇌기능영상등의 다변량분석 방법으로서 그 적용범위가 클 것으로 기대된다.

  • PDF