• 제목/요약/키워드: CT Examinations

검색결과 228건 처리시간 0.028초

Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients

  • Won, Tristan;Lee, Ae-Kyoung;Choi, Hyung-do;Lee, Choonsik
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.98-105
    • /
    • 2021
  • Background: In recent events of the coronavirus disease 2019 (COVID-19) pandemic, computed tomography (CT) scans are being globally used as a complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. It will be important to be aware of major organ dose levels, which are more relevant quantity to derive potential long-term adverse effect, for Korean pediatric and adult patients undergoing CT for COVID-19. Materials and Methods: We calculated organ dose conversion coefficients for Korean pediatric and adult CT patients directly from Korean pediatric and adult computational phantoms combined with Monte Carlo radiation transport techniques. We then estimated major organ doses delivered to the Korean child and adult patients undergoing CT for COVID-19 combining the dose conversion coefficients and the international survey data. We also compared our Korean dose conversion coefficients with those from Caucasian reference pediatric and adult phantoms. Results and Discussion: Based on the dose conversion coefficients we established in this study and the international survey data of COVID-19-related CT scans, we found that Korean 7-year-old child and adult males may receive about 4-32 mGy and 3-21 mGy of lung dose, respectively. We learned that the lung dose conversion coefficient for the Korean child phantom was up to 1.5-fold greater than that for the Korean adult phantom. We also found no substantial difference in dose conversion coefficients between Korean and Caucasian phantoms. Conclusion: We estimated radiation dose delivered to the Korean child and adult phantoms undergoing COVID-19-related CT examinations. The dose conversion coefficients derived for different CT scan types can be also used universally for other dosimetry studies concerning Korean CT scans. We also confirmed that the Caucasian-based CT organ dose calculation tools may be used for the Korean population with reasonable accuracy.

COVID-19 환자에서 음압격리들것을 이용한 흉부 CT 검사에 대한 전문가 의견 설문: 영상품질과 감염위험 (Expert Opinion Questionnaire About Chest CT Scan Using A Negative Pressure Isolation Strecher in COVID-19 Patients: Image Quality and Infection Risk)

  • 진광남;남보다;신재민;황성호
    • 대한영상의학회지
    • /
    • 제84권4호
    • /
    • pp.891-899
    • /
    • 2023
  • 목적 급성호흡기질환인 코로나바이러스감염증-19 (coronavirus disease 2019; 이하 COVID-19) 환자를 대상으로 한 음압격리들것(negative presurre isolation stretcher; 이하 NPIS)을 이용한 흉부 전산화단층촬영(이하 CT) 방식에 대해 전문의들의 경험과 의견을 확인하고자 하였다. 대상과 방법 격리입원 중인 COVID-19 환자에게 NPIS를 이용한 흉부 CT 검사를 시행했던 9개 의료기관 소속 27명의 전문의들을 대상으로 1) 조영증강 흉부 CT가 필요한 경우, 2) NPIS를 이용한 흉부 CT의 영상품질, 그리고 3) CT 조영제주사를 위한 NPIS 개방과 CT 검사실의 오염을 주제로 설문조사를 진행하였다 결과 조사대상인 9개의 의료기관들은 기관당 한 해 평균 116건의 COVID-19관련 흉부 CT 검사를 NPIS와 함께 진행했으며. 전체 검사 건수 중 평균 24건(21%)이 조영증강 흉부 CT였다. 설문에 참여한 호흡기내과 전문의 9명 중 5명(56%)은 환자의 혈중 D-dimer 이상이 확인되면 조영증강 CT가 필요하다고 의견을 밝혔다. 한편 영상의학과 전문의 9명 모두는 NPIS로 인한 흉부 CT 영상의 품질은 폐렴 또는 폐혈전 진단이 가능한 수준이라 답하였다. 또한 감염내과 전문의 9명 중 5명(56%)은 NPIS의 개방으로 인한 CT 검사실의 이차감염은 소독을 통해 예방할 수 있는 수준으로 생각하고 있었다. 결론 격리입원 중인 COVID-19 환자에서 NPIS와 함께 흉부 CT를 진행하더라도 CT의 품질은 진단이 가능한 수준이며 NPIS가 CT 검사실 내에서 잠시 개방되더라도 CT 검사실의 감염확산 위험은 높지 않은 것으로 전문의들은 인식하고 있었다.

CT 조영제를 이용한 차폐체에 대한 연구 (Study on Shielding using CT Contrast Medium)

  • 강헌효;김동현
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.693-698
    • /
    • 2018
  • 현재 의료환경에서 영상의학 검사 시 의료 방사선을 차폐하기 위한 차폐체는 납가운, 납유리가 대부분이다. 이러한 차폐체의 주성분인 납은 납중독과 경량화의 한계, 고가라는 제한점이 있다. 납차폐체 대신 대체 물질로 조영제로 쓰이고 있는 요오드 성분은 방사선을 흡수하는 특성을 지니고 있어 차폐체로써 효과가 있을 것이라 예측하고 있다. 이에 본 연구에서는 투시 검사 시 기존의 납유리 대신 임상에서 사용하고 남은 CT 조영제로 채워진 아크릴판을 이용하여 차폐유무를 평가 하였다. 그 결과 산란선 선량 평가 시 차폐를 하지 않았을 때 보다 CT조영제로 채워진 아크릴판은 7배 이상 차폐효과가 나타났다. 따라서 기존의 납유리 대신 요오드 성분으로 이루어진 CT 조영제가 차폐체로써 활용될 것이라 기대된다.

축방향 CT 스캔과 나선형 CT 스캔에서 영·유아의 장기흡수선량 비교 평가 (A Comparative Evaluation of Organ Doses in Infants and toddlers between Axial and Spiral CT Scanning)

  • 김상태;은성종;김성길
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.137-143
    • /
    • 2013
  • 성인에 비해 방사선에 민감하고 검사건수가 증가하고 있는 영 유아의 CT 스캔 시의 장기흡수선량을 평가하기 위해 스캔부위를 머리부위와 가슴부위로 구분하고 64 MDCT를 이용하여 축방향 스캔과 나선형 스캔으로 비교했다. 스캔부위에 상관없이 나선형 스캔 시의 선량이 축방향 스캔 시 보다 유의하게 낮은 것으로 나타났다. 축방향 스캔과 비교해서 나선형 스캔 중 피치 1.355를 사용했을 때가 나머지 두 피치(0.525, 0.988)를 사용했을 때보다 가슴부위 스캔의 평균 장기흡수선량이 유의하게 높게(평균 -12.03%) 나왔다. 나선형 스캔 시 장기흡수선량이 축방향 스캔보다 평균 20.54% 낮게 나왔다. 결과적으로 인체모형을 통한 장기흡수선량을 평가한 본 연구는 몬테카를로 시뮬레이션 결과값을 실증하고, CT 검사를 받는 영 유아의 장기흡수선량의 보다 정확한 평가에 기여할 것이다.

초기 폐암의 정위방사선치료후 반응평가 분석 (Response Evaluation after Stereotactic Ablative Radiotherapy for Lung Cancer)

  • 최지훈
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.229-233
    • /
    • 2015
  • 정위 방사선치료를 받은 폐암환자에서 결과를 후향적으로 분석하고자 하였다. 연속된 흉부 컴퓨터단층촬영(CT)의 종양의 크기변화 분석을 통해 치료 반응 평가를 조사하였다. 11명의 초기 비소세포폐암환자를 대상으로 정위 방사선치료 선량의 중앙값은 6,000 cGy이고 분할 조사 회수의 중앙값은 5회였다. 경과 관찰기간의 중앙값은 28개월로 치료후 종양의 크기 변화는 총 51회의 CT를 통해 분석하였고, 각 환자당 중앙값 3회의 CT 촬영이 시행되었다. 본 연구에서 치료의 총 반응률은 90.9%로 5명의 환자에서 완전관해와 5명에서 부분관해가 관찰되었다. 부분관해와 완전관해까지의 기간의 중앙 값은 각각 3개월과 5개월이었다. 경과관찰에서 3명의 환자가 병의 진행양상을 나타내었다. 본 연구에서 초기 폐암의 정위방사선치료후 CT 분석을 통해 반응 평가와 함께 치료 반응 시점을 확인할 수 있었다.

비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험 (A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs)

  • 정유철;임창윤;김경민;이성옥;정주현;장진화;오선경;송경진;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제23권2호
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

Effect of Improving Accuracy for Effective Atomic number (EAN) and Relative Electron Density (RED) extracted with Polynomial-based Calibration in Dual-energy CT

  • Daehong Kim;Il-Hoon Cho;Mi-jo Lee
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1017-1023
    • /
    • 2023
  • The purpose of this study was to improve the accuracy of effective atomic number (EAN) and relative electron density (RED) using a polynomial-based calibration method using dual-energy CT images. A phantom composed of 11 tissue-equivalent materials was acquired with dual-energy CT to obtain low- and high-energy images. Using the acquired dual-energy images, the ratio of attenuation of low- and high-energy images for EAN was calibrated based on Stoichiometric, Quadratic, Cubic, Quartic polynomials. EAN and RED were extracted using each calibration method. As a result of the experiment, the average error of EAN using Cubic polynomial-based calibration was minimum. Even in the RED image extracted using EAN, the error of the Cubic polynomial-based RED was minimum. Cubic polynomial-based calibration contributes to improving the accuracy of EAN and RED, and would like to contribute to accurate diagnosis of lesions in CT examinations or quantification of various materials in the human body.

Antioxidative Properties of Amaranth Cauline Leaf and Suppressive Effect against CT-26 Cell Proliferation of the Sausage Containing the Leaf

  • Lee, Heejeong;Joo, Nami
    • 한국축산식품학회지
    • /
    • 제38권3호
    • /
    • pp.570-579
    • /
    • 2018
  • The study investigated antioxidative properties and rectal cancer cell inhibition effect of amaranth (Amaranthus cruentus L.) cauline leaves (ACL) to produce the sausage with ACL powder (ACLP). Antioxidative effects of ACLP prepared with different stem lengths (10-45 cm) were evaluated through DPPH, ABTS, reducing power, total phenol, and total flavonoid. Inhibition effect on rectal cancer cells growth was also examined with CT-26 cell. To determine appropriate ACL amounts in sausage formula, response surface methodology was used. The sausages without ACL (control) and the sausage with ACL (ACLP sausage) were the subjected to the examinations of antioxidation, growth inhibition on CT-26, and physicochemical properties (pH and water content). ACLP made from the leaf with 15 cm length stem generally showed the highest antioxidative effect through results of DPPH, ABTS, reducing power, total phenol, and total flavonoid. ACLP also showed inhibition effect on the proliferation of CT-26, depending on concentration of ACLP. The surface response model showed that 4.87 g of ACLP was optimized amount for sausage production. Physicochemical properties between optimized ACLP and control sausages were not significantly different. Higher antioxidative effect of optimized ACLP sausage extract was observed (p<0.05) in antioxidation tests than control sausage extract except for DPPH. Cell viability of CT-26 cells were higher (p<0.05) in ACLP than in control sausage extracts. These results indicate that ACLP has functional effects on antioxidation activity and growth inhibition on CT-26 cell, and thus, it should be useful as a supplement in sausage, which may some effect as ACLP itself.

소아 전산화단층촬영에서 Volume Mode의 유용성 연구 (The Study of Effectiveness of Volume Mode in Pediatric CT)

  • 박연;김상현
    • 디지털융복합연구
    • /
    • 제12권10호
    • /
    • pp.425-431
    • /
    • 2014
  • 본 연구는 ATOM Phantom을 이용하여 선량, 화질을 비교 분석 하여 Volume mode의 유용성 밝혀 소아 CT 검사에 적극적으로 사용하기 위함이다. Helical mode Noise와 Volume mode의 Noise, HU, SNR은 p>0.05 이므로 통계적으로 유이한 차이가 없음을 알 수 있었다. 각 부위별 선량값은 모두 p>0.05 이므로 통계적 유이한 차이가 없었으나 DLP값이 Helical mode보다 Volume mode가 더 낮게 측정되었다. 유효선량 역시 Volume mode가 Helical mode 보다 낮음을 알 수 있었다. 정성적 분석에서는 Mode에 따른 조건 별로 각각 Helical: 2.6, 3.3, 4.36 Volume: 2.8, 3.64, 4.44, Mode별 Follow up 영상평가 결과로는 Helical mode가 3.8 Volume mode가 3.83점으로 큰 차이가 없는 것으로 나타났다. 5세 이하의 소아 CT검사에 있어서 640-MDCT Volume scan이 Helical mode와 비교해 낮은 선량으로 영상의 질이 큰 차이가 없기에 소아 CT 검사에는 유용 하다고 생각된다.

CT and US Findings of Multilocular Cystic Renal Cell Carcinoma

  • Jong Chul Kim;Kie Hwan Kim;Jun Woo Lee
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.104-109
    • /
    • 2000
  • Objective: Multilocular cystic renal cell carcinoma (MCRCC) is a recently described variety of renal cell carcinoma with characteristic pathologic and clinical features. The purpose of this study was to analyze the imaging findings of MCRCCs. Materials and Methods: Ten adult patients with pathologically proven unilateral MCRCC who underwent renal US and CT were included in this study. The radiologic findings were retrospectively evaluated for cystic content, wall, septum, nodularity, calcification and solid portion by three radiologists who established a consensus. Imaging and postnephrectomy pathologic findings were compared. Results: All patients were adults (six males and four females) and their ages ranged from 33 to 68 years (mean, 46). On US and CT images, all tumors appeared as well-defined multilocular cystic masses composed of serous or complicated fluid. In all patients, unenhanced CT scans revealed hypodense cystic portions, and in four tumors, due to the presence of hemorrhage or gelatinous fluid, some hyperdense areas were also noted. In no tumor was an expansile solid nodule seen in the thin septa, and in only one was there dystrophic calcification in a septum. Small areas of solid portion constituting less than 10% of the entire lesion were found in six of the ten tumors, and these areas were slightly enhanced on enhanced CT scans. In all patients, imaging and pathologic findings correlated closely. Conclusion: On US and CT images, MCRCC appeared as a well-defined multilocular cystic mass with serous, proteinaceous or hemorrhagic fluid, with no expansile solid nodules in the thin septa, and sometimes with small slightly enhanced solid areas. Where radiologic examinations demonstrate a cystic renal mass of this kind in adult males, MCRCC should be included in the differential diagnosis.

  • PDF