• Title/Summary/Keyword: CT Examinations

Search Result 228, Processing Time 0.032 seconds

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

Staging of Esophageal Cancer Using Positron Emission Tomography : Comparing to Computed Tomography (양전자방출단층촬영술(PET)을 이용한 식도암 환자의 병기 결정 -전산화단층촬영술(CT)과의 비교-)

  • 심영목;박승준;김병태;김성철
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.388-393
    • /
    • 1999
  • Background: Correct preoperative staging of esophageal cancer is a prerequisite for adequate treatment. We prospectively compared the accuracy of positron emission tomography (PET) with [fluorine-18]FDG in the staging of esophageal cancer to that of computed tomography (CT). Material and Method: The findings of FDG PET and of chest CT including lower neck and the upper abdomen of 20 biopsy-proven squamous cell carcinoma patients (male, 19; female, 1; mean age, 61) were compared with the pathologic findings obtained from a curative esophagectomy with lymph node dissection. Result: The sensitivities of FDG PET and CT for diagnosis of primary tumor were the same, 90.0% (18/20). Both FDG PET and CT failed to show the primary tumor in 2 of 20 patients; one had a 1cm sized carcinoma in situ and the other had T1 stage cancer. By using the results of the pathologic examinations of 193 removed lymph node groups, we calculated the diagnostic sensitivities, specificities and accuracies of PET and CT (*$\chi$2 p < 0.005). Sensitivity** Specificity Accuracy* PET 55.6%(30/54) 97.1%(135/139) 85.5%(165/193) CT 13.0%(7/54) 98.6%(137/139) 74.6%(144/193) One of four patients with a false-positive for PEThad had active pulmonary tuberculosis. Among the 24 tumor involved lymph node groups, PET failed to show tumor metastasis in 5 lymph node groups abutting the tumor and in 14 lymph node groups located where the decay correction was not performed. Conclusion: Based on the above findings, it is suggested that [F-18]FDG-PET is superior to CT in the detection of nodal metastases and in the staging of patients with esophageal cancer.

  • PDF

The disc morphological changes on CT scan examinations after 5-7years, of acute HIVD patients who underwent oriental medical treatment (조기(早期) 한방치료(韓方治療)를 시행한 요추수핵탈출증(腰椎髓核脫出症) 환자(患者)의 C-T 상(上) 5-7년 후의 추간판(椎間板)의 변화(變化))

  • Mun, Hyung-Cheal;Hwang, Woo-Jun;Lee, Geon-Mok;Cho, Nam-Geun;Gang, Sung-Do;Cho, Jae-Woon;Chang, Byoung-Sun;Jin, Kyong-Son
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.1-12
    • /
    • 2001
  • Study design : A retrospective study of lumbar disc herniations using results of follow-up computed tomographic scan examinations. Objective : Lumbar disc herniations is one of the cause low back pain and lower extremity pain. To clarify the lumbar disc herniations morphological changes over time(mean 5.3 years) in order to establish a strategy for treatment. Methods : Sixteen patients with lumbar disc herniations who underwent follow-up computed tomographic scan examinations were studied. The changes over time in herniated disc size(herniation ratio) were evaluated using this scan technique. The initial computed tomographic scan allowed classification of the herniations according to herniation ratio: small, medium and large. Results : Comparison with follow-up computed tomographic scans showed that of the 16 patients, in 14 patients(88%), the herniation ratio(HR) was decreased and among them, 8 patients had complet resolution of herniated disc. In 2 patients with small herniations, the HR of one case was increased, the other was decreased. In 8 patients with medium herniations, the HR of one case had no change, the others was decreased. In 6 patients with large herniation, the HR of all patients was decreased. Interestingly, 4 of the 16 patients showed calcification change of herniated disc. Conclusion : There is no doubt that herniated disc size is decreased over time. The largest herniations were those which had the greatest tendency to decrease in size. But in some cases, the HR was increased, or calcification change was showed.

  • PDF

Radiological Observation of Coin Lesion in Chest P.A (폐장(肺臟)의 Coin병소(病巢)에 관한 방사선학적(放射線學的) 고찰(考察))

  • Kang, Shin-Hwa
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.128-134
    • /
    • 1985
  • Circumscribed solitary pulmonary nodule is often founded on the plain chest P-A. Even if many study results of coin lesion have been reported by some scholars, it is still very difficult to judge whether the coin lesion is to be benign or malignant. In order to avoid unnecessary surgical treatment, it must be made an examination and analysis very carefully in advance. In the chest P-A, we can grasp the aspects of the site and size of lesion, marginal state of lesion, calcification, cavity, and the growth rate in comparison to follow-up chest P-A. On the basis of above-mentioned analysis, we have to judge whether it is benign or malignant, and decide the next examinations. And then the doctor make diagnosis definitely by the clinical history, plain chest P-A, tomography, bronchography, CT, variable laboratory findings.

  • PDF

The value of panoramic radiography in assessing maxillary sinus inflammation

  • Cho, Bong-Rae;Jung, Yun-Hoa;Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.215-218
    • /
    • 2008
  • Purpose : To evaluate the value of panoramic radiography in diagnosing maxillary sinus inflammation. Materials and Methods : A total of 214 maxillary sinuses from 114 panoramic radiographs were assessed in this study. Two independent experienced oral radiologists evaluated the images in random order for sinus inflammation. Using Cone beam CT images as the gold standard, the sensitivity and specificity of panoramic radiography were calculated, and inter- and intraobserver agreement for panoramic interpretation were obtained. Results : The mean sensitivity and specificity of panoramic radiography were 81.0% and 85.6%, respectively. The weighted kappas for inter- and intraobserver agreement of panoramic radiography were 0.56 and 0.60, respectively. Conclusion : Panoramic radiography is a reasonably accurate method for diagnosing maxillary sinus inflammation and can be used for screening. However, additional examinations should be considered in patients with potentially significant pathology. (Korean J Oral Maxillofac Radiol 2008; 38: 215-8)

  • PDF

A case report of incidental finding of fungus ball on CBCT of maxillary sinus in treatment planning of dental implant (치과 임플란트 치료계획시 상악동의 CBCT 영상에서 우연히 발견된 fungus ball의 일례)

  • Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.93-97
    • /
    • 2010
  • This report was to show the radiographic appearances of the fungus ball in a paranasal sinus and to emphasize the scan area of cone beam computed tomography (CBCT) to detect the calcification in the paranasal sinus. A seventyfour-year-old woman visited our department for the implant rehabilitation at both maxillary posterior edentulous region. Pre-operative radiographic examinations including the panoramic, CBCT, and multidector CT images were taken. An opacification in the right maxillary sinus was observed on the multiplanar image of CBCT, however the pre-determined scan area of CBCT in this report hardly showed the calcifications at the central portion of the maxillary sinus. The opacification in the maxillary sinus could be misdiagnosed as chronic maxillary sinusitis if the calcification of fungus ball was not simultaneously detected. The scan area of pre-operative CBCT needs to be enough to scan the paranasal sinus from top to bottom.

Imaging diagnosis of clonorchiasis

  • Choi, Don-Gil;Hong, Sung-Tae
    • Parasites, Hosts and Diseases
    • /
    • v.45 no.2 s.142
    • /
    • pp.77-85
    • /
    • 2007
  • Among several diagnostic tools for clonorchiasis (Clonorchis sinensis infection), radiologic examinations are commonly used in clinical practices. During the 2 past decades, many reports regarding imaging findings of clonorchiasis were introduced. The basic imaging finding of clonorchiasis is diffuse dilatation of the peripheral intra-hepatic bile ducts, without dilation of the large intrahepatic or extrahepatic bile ducts. By this finding, however, active clonorchiasis cannot be differentiated from cured infection. Some recent radiologic studies suggested specific findings of active clonorchiasis. Besides direct demonstration of worms, increased periductal echogenicity on sonography and periductal enhancement on dynamic contrast-enhanced CT or MR imaging possibly represent active clonorchiasis. Those images of the liver clonorchiasis are known to be correlated with worm burdens (EPG counts) in their frequency and also severity. The images of cholangiocarcinoma associated with clonorchiasis show both the tumor with obstruction images and diffuse dilatation of the peripheral intrahepatic bile ducts. Radiological images can be a good practical alternative diagnostic method of clonorchiasis.

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

The structural change in the hyoid bone and upper airway after orthognathic surgery for skeletal class III anterior open bite patients using 3-dimensional computed tomography (3D-CT를 이용한 골격성 III급 개방교합자의 악교정 수술 전, 후 설골 및 상기도의 변화)

  • Lee, Yoon-Seob;Baik, Hyoung-Seon;Lee, Kee-Joon;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.72-82
    • /
    • 2009
  • Objective: The purpose of this study was to investigate the structural changes of the hyoid bone and upper airway after orthognathic surgery for skeletal class III anterior open bite patients, and make comparisons with normal occlusion. Methods: Pre- and post-operative computed tomography (CT) examinations were performed on 12 skeletal class III anterior open bite patients who were treated with mandibular setback osteotomy. Using the V-works $4.0^{TM}$ program, 3-dimensional images of the total skull, mandible, hyoid bone, and upper airway were evaluated. Results: In the Class III open bite group, the hyoid bone were all positioned anteriorly, compared to the Normal group (p < 0.05). The angle between the hyoid plane and mandibular plane in the Class III openbite group before surgery was greater than in the Normal group (p < 0.05), and the difference increased after surgery (p < 0.01). In the Class III openbite group, the volume of the upper airway decreased after surgery (p < 0.001) and the volume of the upper airway was smaller than the Normal group before and after surgery (p < 0.001). Conclusions: The narrow upper airway space in skeletal Class III openbite patients decreased after mandibular setback osteotomy. This may affect the post-surgical stability.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.