• Title/Summary/Keyword: CT

Search Result 8,147, Processing Time 0.031 seconds

Comparison of CT numbers between cone-beam CT and multi-detector CT (Cone-beam CT와 multi-detector CT영상에서 측정된 CT number에 대한 비교연구)

  • Kim, Dong-Soo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-68
    • /
    • 2010
  • Purpose : To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Materials and Methods : Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, $\rho$ ($g/cm^3$), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. Results : CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were $\rho$=0.001H+1.07 with $R^2$ value of 0.999 for Somatom Emotion, $\rho$=0.002H+1.09 with $R^2$ value of 0.991 for Alphard VEGA, $\rho$=0.001H+1.43 with $R^2$ value of 0.980 for i-CAT and $\rho$=0.001H+1.30 with $R^2$ value of 0.975 for Implagraphy. Conclusion: CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

Image Registration for PET/CT and CT Images with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 PET/CT와 CT영상의 정합)

  • Lee, Hak-Jae;Kim, Yong-Kwon;Lee, Ki-Sung;Moon, Guk-Hyun;Joo, Sung-Kwan;Kim, Kyeong-Min;Cheon, Gi-Jeong;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.195-203
    • /
    • 2009
  • Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  • PDF

Combined PET/CT in Oncology (종양핵의학에서 PET/CT의 역할)

  • Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.80-86
    • /
    • 2002
  • Presently, PET is widely used in oncology, but suffers from limitations of poor anatomical information. To compensate for this weakness, a combined PET/CT has been developed by Professor Townsend at the University of Pittsburgh Medical Center. The prototype was designed as PET and CT components combined serially in a gantry. The CT images provide not only accurate anatomical location of the lesions but also transmission map for attenuation correction. More than 300 cancer patients have been studied with the prototype of PET/CT since July, 1998. The PET/CT studies affected the managements in about $20{\sim}30%$ of cancer patients. These changes are a consequence of the more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake. Now a variety of combined PET/CT scanners with high-end PET and high-end CT components are commercially available. With the high speed of multi-slice helical CT, throughput of patient's increases compared to conventional PET. Although some problems (such as a discrepancy in breathing state between the two modalities) still remain, the role of PET/CT in oncology is very promising.

Evaluation of CT Number Difference between Radiation Therapeutic CT Simulator and Conventional CT (방사선치료용 CT simulator와 진단용 CT의 구조 차이에 의한 CT number의 비교 평가)

  • Seo, Jeong Min;Rhim, Jae Dong;Kim, Chan Hyeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.3
    • /
    • pp.215-219
    • /
    • 2015
  • The purpose in this study is to investigate CT number difference between conventional CT and CT simulator. It shows good correlation in CT number on the muscle, bone, and air. However, in the liver, lungs and water, the low correlation was detected. This result can become the good index for the direction of the distribution of dose difference research between CT equipment for using the computerized radiation therapy planning system.

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Developing Pre-service Teachers' Computational Thinking : Analysis of the Five Core CT Competencies (예비교원의 Computational Thinking(CT) 역량 계발 방안 : CT의 5가지 핵심 역량 분석)

  • Choi, Hyungshin
    • Journal of The Korean Association of Information Education
    • /
    • v.20 no.6
    • /
    • pp.553-562
    • /
    • 2016
  • Although software education pursues developing learners' computational thinking skills, more studies are needed in terms of designing software education lessons to enhance CT skills and to measure the effects of the lessons. This study aims to investigate the effects of a course designed to enhance pre-service teachers' CT skills by using CT-based teaching materials. Through a literature review the study has selected the five core competencies of CT: algorithmic thinking, evaluation, problem decompositions, abstraction, and generalization. The participants of the study are 47 pre-service teachers who took the one-semester course in a national university of education. A survey was developed and conducted and qualitative analyses on the team projects were performed focusing on the core competencies of CT. The results revealed pre-service teachers' perceived degree of experiencing CT and their competencies represented in their projects. The present study provides important implications to future software education programs in terms of designing and implementing of software education.

Measurement of CT Numbers for Effective Atomic Number And Physical Density of Compound (화합물의 물리적 밀도와 유효원자번호에 대한 CT수 측정)

  • Kim, Jong Eon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.125-130
    • /
    • 2021
  • In the AAPM CT performance phantom, there is little data on the CT number of the effective atomic number and physical density corresponding to each peg and water of the CT number calibration insert. Therefore, the necessity of documentation was raised.The purpose of this study is to calculate the effective atomic number for each peg and water of the CT number calibration insert in the AAPM CT performance phantom, and to measure the CT number for the calculated effective atomic number and physical density for comparative analysis.In order to obtain CT number data on the effective atomic number and physical density of each peg and water from the CT number calibration insert of the AAPM CT performance phantom, the effective atomic number for each peg and water was first calculated. Then, CT slices were obtained by scanning the CT number calibration with a CT scanner. CT numbers were measured for each peg and water in the central CT slice. As a result, the CT numbers for the effective atomic number showed a nonlinear pattern of repeating the increase and decrease as the effective atomic number increased. In addition, the CT numbers for physical density showed a nonlinear pattern of repeating the increase and decrease as the physical density increased.

The preliminary study of developing computational thinking practice analysis tool and its implementation (컴퓨팅 사고 실천 분석도구 개발 및 이의 활용에 대한 기초연구)

  • Park, Young-Shin;Hwang, Jin-Kyung
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.10 no.2
    • /
    • pp.140-160
    • /
    • 2017
  • The purpose of this study was to develop computational thinking (CT) analysis tool that can be used to analyze CT practices; first, by defining what CT practices are, and then, by identifying which components of CT are reflected in STEAM classes. Exploring various kinds of CT practices, which can be identified while applying the proposed CT analysis tool for exemplary STEAM classes, is another goal of this study. Firstly, to answer the question of "What is CT in science education" and thereby to develop the proposed CT practice analysis tool, three types of published documents about CT definition as the main data in this study have been considered. In the first "analysis tool development" part of this study, the following five elements have been identified as the main components of CT analysis tool as follows; (1) connecting open problems with computing, (2) using tools or computers to develop computing artifact, (3) abstraction process, (4) analyzing and evaluating computing process and artifact, and (5) communicating and cooperating. Based on the understandings that there is a consistent flow among the five components due to their interactions, a flow chart of CT practice has also been developed. In the second part of this study, which is an implementation study, the proposed CT practice analysis tool has been applied in one exemplary STEAM program. To select the candidate STEAM program, four selection criteria have been identified. Then, the proposed CT practice analysis tool has been applied for the selected STEAM program to determine the degree of CT practice reflected in the program and furthermore, to suggest a way of improving the proposed CT analysis tool if it shows some weak points. Through the findings of this study, we suggest that the actual definition of computational thinking will be helpful to converge Technology and Engineering to STEAM education and a strong complement to reinforce STEAM education.

The Study on a Various Parameter for the CT Test and the Patients-Anxiety of Factor Related (CT검사 시 다양한 매개변수와 환자의 불안 요인에 관한 연구)

  • Baek, Cheol-Oh;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.149-156
    • /
    • 2011
  • This study is to identify perceptions and response degrees of anxiety for each factor, targeting patients for CT test and analyze the relations between factors. It is to provide scientific fundamental data to reduce anxiety by improving awareness of patients about CT test by analyzing relations between variables. The subjects of this study were surveyed in self-writing type, targeting 263 patients for CT test in the department of radiology at three University hospitals from July to September, 2010. This survey was executed once by a structured self-administered survey type. The targeting patients for CT test of anxiety will investigate for affect. Anxiety by each CT test variables depending on CT test-related features showed independent variable is Expense Responsibility, Economic burden, Sufficient explain, Explain agent, Endoscope, Biopsy, Pre treatment, Previous experience, CT side effect experience, Side effect of contrast medium and dependent variable is physical, Hospital staff, Hospital environment, Socioeconomic These used statistics program SPSS (ver. 13.0). Summarizing the above results of this study, awareness of anxiety and response to it in each variable under CT test appeared significant differences in economic burdens, state anxiety, pre-treatment anxiety, exposure anxiety to radiation, and anxiety of side effect. Therefore, pre-treatment before test and pre-training programs on chemical poison of contrast medium and side effect seem to be able to release patients' anxiety level for CT test. Ways to meditate these anxiety variables and reduce degree of anxiety are needed to be researched more and updated. In addition, impact of patients' economic burdens on CT test anxiety is required to be recognized and solved in society level.