• Title/Summary/Keyword: CT산업

Search Result 149, Processing Time 0.026 seconds

Comparison of Time Analysis on the Film Based System Versus PACS in the CT Scanning (CT 검사에서 시간분석에 의한 필름시스템과 PACS의 비교 연구)

  • Kweon, Dae-Cheol;Hong, Sung-Man;Park, Peom
    • IE interfaces
    • /
    • v.15 no.4
    • /
    • pp.439-443
    • /
    • 2002
  • In this paper, we study to evaluate the relative time required to perform the CT scanning in the PACS versus a film-based system and helical versus non-helical studies. Time studies were performed in 175 consecutive CT scanning. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT test was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10~20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.

An Association between Private Health Insurance and Use of Endoscopy, Sonography, CT, MRI, and PET (내시경, 초음파, CT, MRI, PET 검사와 민간의료보험의 관련성 연구)

  • You, Chang-Hoon;Kwon, Young-Dae;Choi, Ji-Heon;Kang, Sung-Wook
    • The Korean Journal of Health Service Management
    • /
    • v.8 no.4
    • /
    • pp.25-34
    • /
    • 2014
  • This paper examined the effects of private health insurance (PHI) on the use of endoscopy, sonography, CT, MRI, and PET among Koreans. The data used was the four waves of the Korea Health Panel (2008-2011), and the number of subjects was 141,862 visits. We employed a pooled logistic regression mode which was corrected with cluster errors. The results showed that PHI was positively related to the use of endoscopy, but not related to the use of sonography, CT, MRI, and PET. It is, however, recommended that health policy makers pay attention to the effects of PHI on the use of sonography, CT, MRI, and PET.

Comparison of Weight Functions in Iterative Technique for Image Reconstruction of Gamma-ray CT (감마 CT 영상재구성을 위한 반복적인 방법의 가중치 함수비교)

  • Lee, Na-Young;Jung, Sung-Hee;Kim, Jong-Bum;Kim, Jin-Sup;Kim, Jae-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10c
    • /
    • pp.480-484
    • /
    • 2007
  • 일반적으로 x선 CT는 물체 투과율이 짧기 때문에 대형 산업공정 내부의 영상진단 시 대상체는 금속으로 구성되어 있으며 내부는 액체, 고체, 기체 등 고밀도 물질이 포함되어 있어 계측이 어렵다. 따라서 본 논문에서는 물체 투과율이 x선에 비해 긴 감마선을 사용하였다. 대형 산업공정 내부의 단면영상을 재구성하기 위하여 반복적인 영상재구성 방법의 가중치 함수를 비교하였다. 실험 결과를 통하여 감마 CT 영상에서 빔 통과 여부에 따른 가중치 함수보다 빔 길이나 면적에 의한 가중치 함수로 복원할 경우, 원 영상과 유사함을 확인하였다.

  • PDF

An Influence of Supportive Policy for CT Industry on Innovation Ability of Organization and OSMU of Contents - Focusing on Domestic Animation Industry (CT산업 지원 정책이 조직의 혁신역량과 콘텐츠의 OSMU화에 미치는 영향 - 국내 애니메이션 산업중심으로)

  • Choi, Young-Kwan;Cho, Sung-Sook
    • Journal of Digital Convergence
    • /
    • v.7 no.4
    • /
    • pp.67-80
    • /
    • 2009
  • The research tried to realize the policy which serves Innovation ability for culture-contents producer, and culture-contents producer's Innovation ability which impacts OSMU of contents in the policies of government for vitalizations of culture-contents industry. As a result, we have reached the conclusion that the supportive policies for technology, exports and marketing were effective to strengthen the innovation ability of management of human resource, creation and production area. Also we have found that content's OSMU has been influenced by innovation ability. The implication of this study are followed. First, the policies which are intended to revitalize the culture content industry by government has the effect that are some different ones from the settlement and intention. Second, the production industry of animation do still passive and closed organization management, without the efforts for opened and cooperative management. Therefore, the efforts of government which are more practical and realistic supports to revitalize and based on strategic cooperation of industry.

  • PDF

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

NMR-CT의 원리 및 그 응용

  • 조장희
    • 전기의세계
    • /
    • v.34 no.9
    • /
    • pp.528-536
    • /
    • 1985
  • 우리나라는 선진 대열에 올라설 수 있는 산업을 중심으로 제2의 도약을 계획하고 있다. 이의 핵심분야인 전자공업의 새로운 장을 연 NMR-CT의 국내 개발은 우리 민족의 우수성을 전세계에 알리는 계기가 됨과 동시에 과학입국으로서 세계어느 나라에도 못지 않는 능력을 과시하게 되었다. 최첨단 기술인 NMR-CT는 1980년대부터 의료진단 분야의 주역이 될 것이며, 치열한 세계경쟁 속에 뛰어 들어 선두대열에서 나아가게 될 것이다. 아울러 많은 첨단분야에서 세계 선진국들과의 경쟁대열에 뒤지지 않기 위해서는 이에 관련된 연구진들의 각고의 노력은 물론 정부와 산업체의 적극적인 지원 및 첨단분야에 대한 새로운 인식이 병행되어야 할 것이다.

  • PDF

The R&D Strategies of the Culture & Contents Technology in the Convergence Era (융복합 시대의 문화콘텐츠 R&D 전략)

  • Rim, Myung-Hwan;Park, Yong-Jae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1248-1253
    • /
    • 2009
  • 문화콘텐츠 산업 발전의 핵심요소인 CT는 디지털 융 복합화의 진전에 따라 게임, 영상, 가상세계, 컴퓨터그래픽 등에 적극 활용되어 문화콘텐츠 산업의 성장에 새로운 기회를 제공할 것으로 예상된다. 또한 문화콘텐츠는 IT 산업의 뒤를 잇는 신성장 동력으로서 고부가가치화를 달성하여 창조경제시대 개막의 견인차 역할을 할 것으로 기대된다. 이 논문은 우리나라가 문화콘텐츠 5대 강국으로 도약하고 세계 수준의 핵심 기술개발 역량으로 "CT 선도국가"로 자리매김하기 위하여 새로운 R&D 추진체계 도입을 연구하였다. 특히 창조 협력 경쟁의 정책철학인 "3CTP 전략"을 통해 산업 및 기술 경쟁력을 강화시키고 R&D 효율성을 제고시키는 시스템을 제안하여 제도적인 측면에서 혁신을 기하고 있다. 본 논문은 이를 도출하기 위해 문화콘텐츠 산업의 중요성, 기술동향 및 경쟁력 분석 등도 수행하였다.

  • PDF

Cone-Beam Microtomography and Its Application (원추형 빔 마이크로 단층촬영기술 및 그 응용)

  • Kim Ho-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.7-14
    • /
    • 2005
  • 본 논고에서는 microfocus X 선 발생장치와 평판형 영상센서를 이용한 micro-CT 시스템의 개발과 그 응용에 대해 소개하였다. 개발과 관련하여서는 영상센서 및 시스템의 동작원리뿐만 아니라 성능평가 결과에 대해서도 간단히 언급하였는데, 이와 같은 성능평가는 추후 개선된 혹은 새로운 설계 및 제작을 위해서는 필수적으로 수반되어야 할 부분이다. 개발된 micro-CT 시스템의 응용분야 소개와 관련하여서는 몇 가지 획득 영상을 토대로 바이오 영상과 산업용 영상에 관하여 언급하였다. 바이오 영상분야에서는 현재 세계적으로 유수 의료기기업체에서 이미 제작하여 판매하고 있으며, 대부분 X선 영상증배관 혹은 CCD(charge-coupled device)를 X 선 영상획득 센서로 사용한 반면, 본 논고에서 소개한 시스템은 평판형 영상센서를 사용했다는 점에서 차별성이 있다. Micro-CT 시스템의 산업용 영상분야로의 적용은 이제 시작 단계이며, 기존 라미노그라피 시스템을 대체하거나 혹은 새로운 응용으로 자리매김할 것으로 기대된다.

Estimation of Void Ratio of Sandy Soil Using X-ray CT Scan (X-ray CT 스캔을 이용한 사질토 간극비 측정)

  • Kim, Kwang-Yeom;Shin, Hyu-Seong;Heo, Seong-Jun;Yim, Sung-Bin;Kwon, Young-Cheul;Kim, Hong-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.1
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, a new methodology by using the X-ray CT scan is proposed for estimating void ratio of sandy soil. The general problems in high resolution X-ray CT scan such as beam hardening and ring artifact had been successfully settled up using thin metal plate filter and some calibration process. In order to calculate the void ratio of sand from its CT image, the procedures and algorithm for CT image processing are developed. CT scan tests for Joomunjin sand are carried out to verify its applicability to void ratio testing.