• Title/Summary/Keyword: CT값

Search Result 11, Processing Time 0.03 seconds

Convergence Comparison of Metal Artifact Reduction Rate for Pacemaker Insertion of CT Imaging Phantoms in the Raw Data with MAR Algorithm (심박조율기 삽입 팬텀의 CT영상 원시데이터에 금속인공물감소 알고리즘 적용 시 금속인공물 감소율의 융합적 비교)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • In the analyzed cardiac CT algorithm applied when comparing the MAR self-made metal artifact reduction in pacemaker inserted phantom degree. Result of comparing the energy value by CT showed a decrease in the CT value in the case of BKG 40 KeV in WSA maximum decreased to 663.2% in the case of 140 KeV BHA were increased a maximum of 56.2%. In addition, the maximum was decreased by approximately 145% based on a 70 KeV artifacts in CT value comparison by type WSA, BHA was to increase up to approximately 46.38%. MAR Algorithm is believed to provide a more quality cardiac CT image if the energy changes, or have the effect that by type and irrespective of reduced metal artifacts occurrence of artifacts applied to the pacemaker when tracking a heart CT scan after inserting MAR algorithm.

Inactivation Effect of Cryptosporidium by Ozone and UV (Ozone과 UV를 이용한 Cryptosporidium의 불활성화 효과)

  • Kim, Yun-Hee;Lee, Chul-Hee;Lee, Shun-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • The objective of this study was to investigate the inactivation characteristics of Cryptosporidium oocysts by ozone and UV and to suggest the better, disinfection method. The inactivation CT value of 1 log(90%) and 2 log(99%) in of one disinfection, which is an index of disinfection for inactivation effect by ozone, were respectively 5.77 $mg{\cdot}min/L$ and 21.30 $mg{\cdot}min/L$. The inactivation in UV disinfection was not affected by pHs(5, 7 and 9), low turbidity(5 and below NTU) and UV intensity(0.2 and 0.6 $mWs/cm^2$) but obviously decreased at high turbidity over 20 NTU. Therefore UV disinfection capacity can be obtained when a good turbidity removal in drinking water treatment process is achieved. And if oocysts is exposed by high UV over 0.6 mWs/cm2 during enough time, the better inactivation effect will be obtained.

Development of the method for optimal water supply pump operation considering disinfection performance (소독능을 고려한 송수펌프 최적운영기법 개발)

  • Hyung, Jinseok;Kim, Kibum;Seo, Jeewon;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

A study of beam hardening effect reduction occur in brain CT (Brain CT에서 발생하는 선속경화현상 감소방안에 관한 연구)

  • Kim, Hyeon-ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8479-8486
    • /
    • 2015
  • This study aim is occur in brain CT cause of beam hardening effect and reducing method, We will scan Bone opaque bead phantom on variation of image on the influence factor with equipment called 'Samatom Senation 16' with following listed herein : tube voltage, tube current, slice thickness, gantry angle, base line which affect beam-hardening effect. After that we are going to start Quantitative Analysis resulted in previous scanning and Qualitative Assessment with CT image sheet evaluation. result of quantitative analysis 140kVp $31.56{\pm}2.89HU$ on tube voltage, 150mA $-3.87{\pm}0.12HU$ on tube current, 3mm on slice thickness, and $13.31{\pm}1.03HU$ IOML on gantry angle which was the least beam-hardening effect. Like Qualitative Analysis, we went through Qualitative Assessment and most of valuers got a result of 140kVp on tube voltage, 150mA on tube current, 3mm on slice thickness. As before valuers evaluated gantry angle that scanned image from IOML or OML was the least beam-hardening effect occured. There are meaningful differences when we compare all theses factors statistically(P<0.05). therefore We consider that Minimizing artifact that caused by beam-hardening effect can provide better quality of image to deciphers and patients. if we rise tube voltage in permissible dose limit, set tube current in a limit that does not effect to image quality, use slice thickness too thin enough to harm resolution, use IOML or OML on gantry angle.

A New Disinfestation Approach Against Some Greenhouse Pests Using Ethyl Formate Fumigation (훈증제 에틸포메이트를 이용한 몇 가지 시설하우스 해충에 대한 새로운 방제 전략)

  • Kwon, Tae-Hyung;Jeong, In-Hong;Lee, Byung-Ho;Park, Chung Gyoo
    • Korean journal of applied entomology
    • /
    • v.58 no.4
    • /
    • pp.341-345
    • /
    • 2019
  • Ethyl formate (EF) is a rapid kill, environmentally safe, and low mammalian toxicity fumigant, registered to disinfest quarantine insect pests from imported agricultural products. A new concept for controlling insect pests of agricultural crops was tested in a fumigation chamber with EF. Control efficacy of and phyto-toxicity due to EF fumigation were evaluated against four pests (Thrips palmi, Bemisia tabaci, Myzus persicae, and Tetranychus urticae) and on seedlings of four fruit vegetables (FVs; yellow melon, cucumber, tomato, and pepper). Ethyl formate fumigation at a dose of 1.5 g m-3 for 12 h produced >93.3% mortality in T. palmi, B. tabaci, and M. persicae. However, T. urticae was tolerant to fumigation, showing only 20% mortality at 2.0 g m-3. In terms of concentration × time (CT) products, at least 8.9 g·h m-3 CT at 20 ± 1.5℃ was needed to achieve > 90% mortality against the three susceptible insect pests. Fumigation at 1.5 g m-3 for 12 h caused no phyto-toxicity to any of the four FV seedlings. Ethyl formate application, as a new disinfestation method in greenhouses, could be an alternative to reduce the use of conventional insecticides. However, further studies are needed to determine the efficacy of this method at different pest developmental stages and in different greenhouse environments. Additionally, research is needed to elucidate the phyto-toxicity of EF application at different growing stages of a wide variety of crops.

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT) (심장 CT 검사시 ASIR 적용에 따른 선량 평가)

  • Jang, Hyun-Cheol;Kim, Hyun-Ju;Cho, Jae-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.252-259
    • /
    • 2011
  • To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.

Viral Load Dynamics After Symptomatic COVID-19 in Children With Underlying Malignancies During the Omicron Wave

  • Ye Ji Kim;Hyun Mi Kang;In Young Yoo;Jae Won Yoo;Seong Koo Kim;Jae Wook Lee;Dong Gun Lee;Nack-Gyun Chung;Yeon-Joon Park;Dae Chul Jeong;Bin Cho
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.2
    • /
    • pp.73-83
    • /
    • 2023
  • Purpose: This study aimed to investigate the viral load dynamics in children with underlying malignancies diagnosed with symptomatic coronavirus disease 2019 (COVID-19). Methods: This was a retrospective longitudinal cohort study of patients <19 years old with underlying hemato-oncologic malignancies that were diagnosed with their first symptomatic severe acute respiratory syndrome coronavirus 2 polymerase chain reaction (PCR)-confirmed COVID-19 infection during March 1 to August 30, 2022. Review of electronic medical records and telephone surveys were undertaken to assess the clinical presentations and transmission route of the patients. Thresholds of negligible likelihood of infectious virus was defined as E gene reverse transcription (RT)-PCR cycle threshold (Ct) value ≥25. Results: During the 6-month study period, a total of 43 children with 44 episodes of COVID-19 were included. Of the 44 episodes, the median age of the patients included was 8 years old (interquartile range [IQR], 4.9-10.5), and the most common underlying disease was acute lymphoid leukemia (n=30, 68.2%), followed by patients post-hematopoietic stem cell transplantation (n=8, 18.2%). Majority of the patients had mild COVID-19 (n=32, 72.7%), and three patients (7.0%) had severe/critical COVID-19. Furthermore, 2.3% (n=1) died of COVID-19 associated acute respiratory distress syndrome. The largest percentage of the patients showed E gene RT-PCR Ct value ≥25 between 15-21 days (n=13, 39.4%), followed by 22-28 days (n=10, 30.3%). In 15.2% (n=5), E gene RT-PCR Ct value remained <25 beyond 28 days after initial positive PCR. Refractory malignancy status (β, 67.0; 95% confidence interval, 7.0-17.0; P=0.030) was significantly associated with prolonged duration of E gene RT-PCR <25. A patient with prolonged duration of E gene RT-PCR Ct value <25 was suspected to have infectivity shown by the transmission of the virus to his mother at day 86 after his initial positive test. Conclusions: Children that acquire symptomatic COVID-19 during refractory malignancy state are at a high risk for prolonged shedding warranting PCR-based transmission precautions in this cohort of patients.

Feasibility Assessment on the Application of X-ray Computed Tomography on the Characterization of Bentonite under Hydration (벤토나이트 수화반응 특성화를 위한 X선 단층촬영 기술 적용성 평가)

  • Melvin B., Diaz;Gyung Won, Lee;Seohyeon, Yun;Kwang Yeom, Kim;Chang-soo, Lee;Minseop, Kim;Jin-Seop, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.491-501
    • /
    • 2022
  • Bentonite has been proposed as a buffer and backfill material for high-level radioactive waste repository. Under such repository environment conditions, bentonite is subjected to combined thermal, hydrological, mechanical, and chemical processes. This study evaluates the feasibility of applying X-ray CT technology on the characterization of bentonite under hydration conditions using a newly developed testing cell. The cylindrical cell is made of platic material, with a removable cap to place the sample, enabling to apply vertical pressure on the sample and to measure swelling pressure. The hydration test was carried out with a sample made of Gyeonju bentonite, with a dry density of 1.4 g/cm3, and a water content of 20%. The sample had a diameter of 27.5 mm and a height of 34 mm. During the test, water was injected at a constant pressure of 0.207 MPa, and lasted for 7 days. After one day of hydration, bentonite swelled and filled out the space inside the cell. Moreover, CT histograms showed how the hydration process induced an initial increase and later progressive decrease on the density of the sample. Detailed profiles of the mean CT value, CT standard deviation, and CT gradient provided more details on the hydration process of the sample and showed how the bottom and top regions exhibited a decrease on density while the middle region showed an increase, especially during the first two days of hydration. Later, the differences in CT values with respect to the initial state decreased, and were small at the end of testing. The formation and later reduction of cracks was also characterized through CT scanning.