• 제목/요약/키워드: CT(Computed Tomogram)

검색결과 40건 처리시간 0.03초

파노라마촬영장치의 선형단층상에 의한 하악골의 협설단면 평가 (An assessment on cross-sectional view of the mandible by linear tomogram of panorama)

  • 홍순기;김재덕
    • Imaging Science in Dentistry
    • /
    • 제31권2호
    • /
    • pp.101-107
    • /
    • 2001
  • Purpose: To evaluate the precision of measurements of distances and angle in the cross-sectional views of linear tomogram of panorama and to assess the technique for visualizing the mandibular canal. Methods: Ten dry mandibles were radiographically examined with 3 continuous cross-sectional views of linear tomogram of panorama and 4 continuous computed tomograms. The distance between the superior border of canal and alveolar crest and the bucco-lingual width of alveolar bone at the level of the superior border of canal and the angle between the two lines above were measured. Measurements were performed by radiologist and implantologist group and compared with measurements on computed radiograms of the same areas. Results: The measurements differences for the distance of alveolar bone height between in panorama and in CT showed 0.9 mm±0.6 mm by radiologists and 1.3mm±0.8mm by implantologists. There was no statistically significant difference between two groups' measurements. The differences in measurements for the distance of alveolar bone width between in panorama and in CT showed 0.5mm±0.8mm by radiologists and 2.5mm±1.4 mm by implantologists. There was significant difference (P<0.05) between two groups' measurements. The average bucco-lingual inclination of alveolar bone above mandibular canal was average 95.8° in CT. The difference of measurements between two groups was average 1±0.9°. Three cross-sectional views of panorama could show that the mandibular canal crosses antero-lingually and slopes inferiorly from the posterior segment of the mandible. Conclusions: The measurements in the linear tomogram of panorama by radiologists gave the accurate values of the distances and the angle compared with the values in computed tomograms.

  • PDF

악골 병소의 켬퓨터 촬영상에서 Hounsfield Unit에 관한 연구 (STUDY FOR HOUNSFIELD UNITS IN COMPUTED TOMOGRAM WITH JAW LESION)

  • 김철환;정종일
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권4호
    • /
    • pp.391-396
    • /
    • 2006
  • The CT number is called Hounsfield unit(HU). Generally HU has a score between +1000 from -1000, and it is standardized usingthe air(-1000), water(0), and compact bone(+1000). Hounsfield Unit to standardize the density in computed tomography using the air and water has been used to analysis of lesion in other medical field. Computed tomography is popular method to analysis of lesion in oral & maxillofacial field but the analysis about density of lesion by Hounsfield unit is still obscure. For this study, computed tomography taken in Dankook University Dental Hospital and Hounsfield unit was measured to compare the difference of jaw bone lesion as cystic lesion, benign tumor, malignant tumor.

악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용 (Application of Simulated Three Dimensional CT Image in Orthognathic Surgery)

  • 김형돈;유선국;이경상;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

관골구 골절에서의 전산화단층촬영술의 진단적 가치 (Diagnostic Value of Computed Tomography in Acetabular Fracture)

  • 김선용;박복환;인주철
    • Journal of Yeungnam Medical Science
    • /
    • 제5권1호
    • /
    • pp.43-48
    • /
    • 1988
  • 골절의 모양, 범위 및 골편의 해리의 정도를 C.T.로서 잘 결정할 수 있었다. 고관절을 비롯한 기타 골반골의 골절과 연부 조직손상 정도를 잘 알 수 있었다. 고식적인 단순 Z-선 촬영으로 발견이 안 되었던 고관절내 골편의 유 무를 잘 관찰할 수 있었다. 골반골 골절이 있는 움직이기 어려운 환자에서 검사가 쉽고, 용이하게 이루어질 수 있었다. 수술후 관절강내 골편이나 개방성복술에 대한 평가를 잘 할 수 있었다.

  • PDF

전산화단층상을 이용한 측두하악관절의 삼차원 재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF TEMPOROMANDIBULAR JOINT USING COMPUTED TOMOGRAM)

  • 임숙영;고광준
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.335-344
    • /
    • 1993
  • The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joints were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint spaces were more clearly visualized on dissection images.

  • PDF

개에서 컴퓨터단층촬영을 이용한 두부 외상의 평가 3례 (Computed Tomographic Evaluation of Three Canine Patients with Head Trauma)

  • 김태훈;김주형;조항묘;천행복;강지훈;나기정;모인필;이영원;최호정;김근형;장동우
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.667-672
    • /
    • 2007
  • This report describes the use of conventional computed tomography(CT) for the diagnosis of head trauma in three canine patients. According to physical and neurologic examinations, survey radiography and computed tomography, these patients were diagnosed as traumatic brain injury. Especially, CT is the imaging modality of first choice for head trauma patients. It provides rapid acquisition of images, superior bone detail, and better visualization of acute hemorrhage than magnetic resonance imaging. It is also less expensive and more readily available. Pre-contrast computed tomography was used to image the head. Then, post-contrast CT was performed using the same technique. The Modified Glasgow Coma Scale(MGCS) score was used to predict their probability of survival rate after head trauma in these dogs. Computed tomogram showed fluid filled tympanic bulla, fracture of the left temporal bone and cerebral parenchymal hemorrhage with post contrast ring enhancement. However, in one case, computed tomographic examination didn't delineate cerebellar parenchymal hemorrhage, which was found at postmortem examination. Treatments for patients placed in intensive care were focused to maintain cerebral perfusion pressure and to normalize intracranial pressure. In these cases, diagnostic computed tomography was a useful procedure. It revealed accurate location of the hemorrhage lesion.

한방 치료로 완전관해에 이른 폐로 전이된 유방암 1례 (Case of Complete Remission of Breast Cancer Metastasized to Lung Treated by Traditional Korean Therapy)

  • 한재복;하태현;김성수;성신
    • 동의생리병리학회지
    • /
    • 제27권6호
    • /
    • pp.818-822
    • /
    • 2013
  • This report is aimed to investigate the effect of Traditional Korean Therapy (TKT) in treating recurred breast cancer metastasized to lung. A 53-year-old woman who was diagnosed as left breast cancer and underwent surgery, adjuvant chemotherapy and radiotherapy in early 2009 was admitted for the treatment of recurred, metastatic lung cancer in late 2012. She was treated with TKT including acupuncture, moxibustion and pharmacopuncture. The effect was evaluated with positron emission tomogram and computed tomogram (PET-CT). The metastatic tumors in both lungs were disappeared after the treatment for about 2 months. These results suggest that TKT is a therapeutic method to treat metastatic lung cancer originated from breast cancer.

안면부 골절 수술 전후 다중검출기 전산화 단층촬영의 효용성 비교 (Comparison of the Usefulness of MDCT (Multidetective Computed Tomogram) in Facial Bone Fractures)

  • 홍윤기;김형택
    • Journal of Trauma and Injury
    • /
    • 제19권1호
    • /
    • pp.28-34
    • /
    • 2006
  • Purpose: In maxillofacial surgery, proper preoperative diagnosis is very important in achieving good postoperative results. Although conventional CT scans are useful for visual representations of fractures, they cannot provide direct guidance for reconstructing facial bone fractures. However, the recent technology of multislice scanning has brought many clinical benefits to CT images. Direct correlations can be made between preoperative imaging data and operative planning. The aim of the current study is to evaluate the differences between conventional CT and multidetective three-dimensional CT(3D MDCT) measurements in craniofacial deformities. Methods: From January 2005 to November 2005, MDCT scans of 41 patients were evaluated by comparing them with conventional CT scans. The 3D MDCT images were assessed and reviewed by using a simple scoring system. Results: The 3D MDCT scans offered easy interpretation, facilitated surgical planning, and clarified postoperative results in malar complex fractures, mandibular fractures, and extensive maxillofacial fractures and cranioplasty. However, 3D MDCT images were not superior to conventional CT scans in the diagnosis of blowout fractures. Conclusion: In spite of its limitations, the 3D MDCT provided additional and more comprehensive information than the conventional CT for preoperative assessment of craniofacial deformities. Therefore, the 3D MDCT can be a useful tool for diagnosis and systematic treatment planning in craniofacial skeletal deformities.

식도 이물 모델에서 이물 탐색을 위한 삼차원 재구성법의 활용 (Detection of Foreign Body in Esophageal Foreign Body Model Using Three Dimensional Reconstruction Technique)

  • 우국성;유영삼;김동원
    • 대한기관식도과학회지
    • /
    • 제18권1호
    • /
    • pp.13-18
    • /
    • 2012
  • Objective This study was conducted to gather basic information of 3D CT in detecting and gaining information of esophageal foreign body (FB) models. Materials and Methods The chest model was made using PVC bottle, rubber balloon and plaster. Fish bone, Persimmon stone were used to mimic foreign bodies of esophageal model. The foreign body models were inserted into the balloon removing air from it and the balloon was sealed. The esophageal FB model was inserted into the chest model. The remaining space in the chest model was filled with fish paste and water to simulate soft tissue around esophagus. CT of chest model was reconstructed three-dimensionally by Rapidia software to make images of foreign body models. The axial CT, MPR image and VOI image were compared with real foreign body materials as to shape, size, location and orientation. Results Esophageal FB models were easily made. CT data gave good 3D images and showed realistic foreign body materials. Conclusion The results indicate the usefulness of 3D CT technique to help in diagnosis of esophageal foreign body models.

  • PDF

신경아세포종의 전산화단층촬영 소견 (Neuroblastoma : Computed Tomographic Finding)

  • 김재운;최종오;조재호;황미수;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제13권1호
    • /
    • pp.134-140
    • /
    • 1996
  • 1986년부터 1995년까지의 10년간 영남대학교 의과대학 부속병원에서 절제술이나 세침 생검을 시행하여 조직 병리학적으로 확진된 신경아세포종 23례 중 전산화단층촬영을 시행한 16례를 대상으로 후향적으로 분석한 결과 신경아세포종은 소아에서 많이 발생하며, 부신에서 호발하고, 임상적인 주 증상은 만져지는 종괴였다. 전산화단층촬영소견은 과반수 이상에서 작고 고밀도이거나 곡선 모양의 석회화를 보이며, 중앙선을 침범하며, 분엽상의 모양과 분명한 경계를 보이고, 내부에 낭성 변화를 보이며, 불균등한 조영 양상을 보이고, 주위 중요 혈관과 림프절을 침범한 소견을 보였다. 이와 같은 전산화 단층촬영소견들은 소아 복부 종양에서 신경아세포종의 진단과 감별에 도움을 줄것으로 생각된다.

  • PDF