우수유출 모형을 이용한 합류식하수관로시스템의 월류량, 월류빈도 산정 기준 결정 연구 (Criteria for calculation of CSO volume and frequency using rainfall-runoff model)

  • 이건영;나용운;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.313-324
    • /
    • 2013
  • It is widely known that untreated Combined Sewer Overflows (CSOs) that directly discharged from receiving water have a negative impact. Recent concerns on the CSO problem have produced several large scale constructions of treatment facilities, but the facilities are normally designed under empirical design criteria. In this study, several criteria for defining CSOs (e.g. determination of effective rainfall, sampling time, minimum duration of data used for rainfall-runoff simulation and so on) were investigated. Then this study suggested a standard methodology for the CSO calculation and support formalized standard on the design criteria for CSO facilities. Criteria decided for an effective rainfall was over 0.5 mm of total rainfall depth and at least 4 hours should be exist between two different events. An Antecedent dry weather period prior to storm event to satisfy the effective rainfall criteria was over 3 days. Sampling time for the rainfall-runoff model simulation was suggested as 1 hour. A duration of long-term simulation CSO overflow and frequency calculation should be at least recent 10 year data. A Management plan for the CSOs should be established under a phase-in of the plan. That should reflect site-specific conditions of different catchments, and formalized criteria for defining CSOs should be used to examine the management plans.

장기간 강우-유출 모의를 통한 합류식하수관로시스템의 월류부하량 저감목표 설정 연구 (Set up Reduction Goals of Combined Sewer Overflow Pollutant Load Using Long-Term Rainfall-Runoff Model Simulation)

  • 이건영;나용운;류재나;오재일
    • 대한환경공학회지
    • /
    • 제35권11호
    • /
    • pp.785-794
    • /
    • 2013
  • 합류식하수관로시스템에서 강우시 유출수는 관로내 퇴적물과 지표면 세척효과에 의한 오염물질 등이 혼합되어 하천으로 방류되기 때문에 방류수계에 화학적 물리적 생물학적으로 상당한 문제를 야기하지만, 현재 국내에서는 CSOs의 오염 부하량 관리기준을 결정함에 있어 통일된 방법론이 부재한 실정이다. 이에 따라 본 연구에서는 우수유출모형을 활용한 장기간 CSOs 유량-수질모의를 통하여 CSOs의 오염부하량 저감목표를 설정하고자 한다. 이를 위하여 국내외 CSOs 관리기준을 검토하였으며, 그 결과 연간 총 월류부하량 및 발생빈도를 총 2단계로 구분하여 관리하고, 1단계에서는 60%, 2단계에서는 85%를 저감하는 것을 목표로 설정하였다. 도출된 저감 목표 기준을 대상지역에 적용하여 장기간(최소 10년간)의 CSOs 발생 모의를 바탕으로 분석한 결과, BOD 월류부하량 저감목표는 1단계 1,123 kg, 2단계 2,374 kg이었으며, 목표 달성을 위해 대응해야 할월류량은 1단계 $11,685m^3$, 2단계 $24,701m^3$으로 나타났다.

전기전도도를 이용한 CSO의 유량 추정 (The Flow rate estimation of CSOs using EC Data)

  • 최원석;송창수
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.751-757
    • /
    • 2011
  • The monitoring technique based on electrical conductivity (EC) can provide researchers with some advantages in maintenance management and is cost-effective as compared with existing CSOs monitoring. In this study, the flow rate estimation using EC data was executed in two sites where storm overflow chamber had installed. In the result of A-site, R2 of second order multinomial between dilution ratio of EC and observed flow rate was showed the range of 0.68 ~ 0.77. And $R^{2}$ of B-site was 0.62 ~ 0.81. On the other hand, cumulative frequency of A-site was 43.4 ~ 52.2% in the relative error level of under 20%. And B-site was 10.1 ~ 46.5%. The flow rate estimation formula was improved through consideration of some parameters including antecedent dry days and rainfall duration. And difference between estimated flow rate and observed flow rate in total rainfall event was very small.

가변 주파수 Sono-Fenton 산화를 이용한 Spent-GAC 재생기술 (Spent-GAC Regeneration Using Variable Frequency Sono-Fenton Oxidation)

  • 주수빈;이상민;김형준;심인태;김희진
    • 대한토목학회논문집
    • /
    • 제43권4호
    • /
    • pp.449-458
    • /
    • 2023
  • 용존 유기물을 흡착 제거하는 기술로서, 흡착능이 우수한 입상활성탄을 우선적으로 적용할 수 있지만, 흡착탑의 운전기간에 따라 GAC의 흡착능이 현저히 저하되어 파과되는 한계가 있으며 파과된 활성탄인 spent-GAC는 교체나 재생이 불가피하다. 활성탄 교체는 비용의 경제성 때문에 기피되며 상업적으로 열재생법을 사용하고 있으나, 800℃ 이상의 고온 조건으로 인한 높은 에너지 비용과 활성탄의 질량 손실이 발생하는 단점이 있다. 본 연구에서는 CSOs내의 용존 유기물 처리에 사용된 spent-GAC의 재생효율을 제고하기 위해, Fenton 산화법과 초음파 산화를 융합한 다중산화기술인 Sono-Fenton 방법을 적용하였고, 산화제 주입농도와 초음파 주파수별 spent-GAC의 재생효율을 조사하였다. 적용된 Sono-Fenton 처리에서 Fe2+ 10 mmol/L, H2O2 농도 1,000 mmol/L, 120분 초음파 주사시간, 초음파 주파수 40 kHz 재생처리 조건에서 68.5%의 가장 높은 재생효율을 얻을 수 있었고, 750 kHz에서도 유사한 효율을 얻을 수 있었으며, 다른 주파수의 초음파는 재생효율이 불량했고 주파수의 크기와 GAC 재생효율은 선형 관계를 나타내지 않았다. 실 하수를 희석하여 제조한 CSOs로 GAC 흡착탑을 연속운전 한 경우, 재생없이 700시간 내외의 운전이 가능했고 1회의 Sono-Fenton 처리를 적용한 결과, 총 1,000시간의 GAC 흡착 운전 기간 동안 40~70%의 CODcr 제거 효율이 확보하였다.