• Title/Summary/Keyword: CSMT survey

Search Result 5, Processing Time 0.017 seconds

Hydrogeologic Structure derived from Electrical and CSMT Surveys in the Chojung Area (전기 및 CSMT 탐사를 이용한 초정지역의 수리지질 구조 해석)

  • Song Sung-Ho;Yong Hwan-Ho;Kim Jin-Ho;Song Seung-Yup;Chung Hyung-Jae
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.118-125
    • /
    • 2002
  • The hydrogeologic structure in the Chojung area was evaluated from a set of geological and geophysical investigations: detailed geological survey, vertical electric sounding (VES), borehole logging, and controlled-source magnetotelluric (CSMT) survey. Among these, CSMT soundings were taken for integrated interpretation to extend hydrogeologic structure with depth. The result of CSMT survey along with VES and borehole logging provides the vertical geologic boundary connected with hydrogeologic structure, and also indicates the depth of aquifer in granite basement. To interpret the geologic boundary and aquifer characteristics using CSMT data, we adopted the technique of 1-D inversion with smoothness-constrained method and 2-D continuous profiling with 1-D Bostick inversion and spatial filtering. The methodology tested and adopted in this study would be useful and required for providing a more information to the structure of fractured aquifer system.

A Geophysical Survey of an Iron Mine Site (철광산 지역에서의 물리탐사 기술 적용 연구)

  • Kim, Kiyeon;Oh, Seokhoon
    • Journal of the Korean earth science society
    • /
    • v.34 no.6
    • /
    • pp.575-587
    • /
    • 2013
  • DC electrical and electromagnetic survey was applied to evaluate the reserve of an iron mine site. We analyzed the borehole cores and the cores sampled from outcrops in order to decide which geophysical method was efficient for the evaluation of iron mine site and to understand the geological setting around the target area. Based on the core tests for specific weight, density, porosity, resistivity and P-wave velocity, showing that the magnetite could be distinguishable by the electrical property, we decided to conduct the electrical survey to investigate the irone mine site. According to previous studies, the DC electrical survey was known to have various arrays with high resolutions effective to the survey of the iron mine site. However it was also known that the skin depth is too shallow to grasp the deep structure of iron mine. To compensate the weakness of the DC electrical method, we applied the MagnetoTelluric (MT) survey. In addition, a Controlled Source MT (CSMT) method was also applied to make up the shortcoming of MT method which is weak for shallow targets. From the DC electrical and MT survey, we found a new low resistivity zone, which is believed to be a magnetite reserve beneath the old abandoned mine. Therefore, this study was confirmed for additional utility value.

An Interpretation of Hydrogeologic Structure Using Geophysical Data from Chungwon Area, Chungcheongbuk-Do (물리탐사자료를 이용한 수리지질구조 해석 -충청북도 청원지역)

  • 송성호;정형재;권병두
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.283-293
    • /
    • 2000
  • A set of geophysical survey results over an area in Bookil-myun, Chungwon-Gun, Chungcheongbuk-Do is presented; resistivity logging, d.c. sounding, dipole-dipole resistivity, and controlled-source magnetotelluric (CSMT) surveys. These surveys were chosen in this research for the estimation of the basement depth and the delineation of the hydrogeologic structure over the survey area. The results provide an optimal input to a hydrogeologic modeling analysis using the strategies built in GIS software. A total of 14 lines of dipole-dipole resistivity surveys, 25 stations of d.c. sounding and 6 stations of CSMT sounding were performed. In addition 10 boreholes were chosen for resistivity logging to correlate the logs to the surface data. A quantitative information on the hydrogeologic structure over the area is provided by synthesizing the results from various geophysical data and attribute layers are constructed by utilizing a GIS software Arc/ Info. The constructed layers match well to the hydrogeologic structures, which were outlined from the drilling data. The methodology tested and adopted in this study would be useful for providing a more reliable input to the hydrogeologic model setup.

  • PDF

Controlled Source Magnetotellurics with Vector Measurement Using Electric and Magnetic Sources (전기장 또는 자기장 송신원을 이용한 벡터 CSMT)

  • Lee, Heuisoon;Song, Yoonho
    • Economic and Environmental Geology
    • /
    • v.30 no.5
    • /
    • pp.451-458
    • /
    • 1997
  • The horizontal magnetic dipole as well as electrical dipole was adopted as a source to compute one-dimensional electromagnetic field behavior in controlled source magnetotellurics. he Cagniard impedances due to horizontal magnetic dipole source, especially phases, showed better frequency characteristics than those due to electric one. The magnetic dipole is inferior to the electric dipole in the point of relatively weak transmitting power at low frequency. But considering high resistivity charateristics of Korean geology, the magnetic dipole source is recommended for the survey up to depth of 500 m. A vector CSMT was introduced to get more reliable data in the area of two- or three-dimensional structures. A software and interpretation technique using polarization ellipses were developed. The technique was tested by synthetic data, which provided theoretical basis of the methodology. Although CSMT has inevitable limitation of investigation depth due to practically possible source-receiver separation, we proposed to use the technique developed in this paper where MT is not available, for example, in extremely noisy area or for shallow target.

  • PDF

Application of integrated geophysical methods to investigate the cause of ground subsidence of the highly civilized area

  • Kim Jung-Ho;Yi Myeong-Jong;Hwang Se-Ho;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.410-415
    • /
    • 2003
  • Ground subsidence has occurred in the downtown of Muan-eup in Korea. Integrated geophysical survey, including two-dimensional resistivity, CSMT(Controlled source magnetotelluric), magnetic, borehole logging, GPR and resistivity tomography, has been conducted to investigate the cause of subsidence and ground conditions. Since the target area is in the city downtown, there were no spaces for surface geophysical methods. To get regional geology and to facilitate the detailed geophysical interpretation in the survey area, two-dimensional resistivity, CSMT and magnetic surveys have been applied in the outer region of the downtown. From these results, we could accurately define the Gwangju fault system and estimate the geologic conditions in the downtown. For the detailed survey of the downtown area, resistivity tomography and borehole logging data have been acquired using a few tens of densely located boreholes. Among these survey results, borehole logging data provided the guide to classification of the rock type and we could define the geologic boundary of granite and limestone formations. From the resistivity tomograms of 42 sections, which are densely located enough to be interpreted in a three-dimensional manner, we could delineate the possible weak zones or cavities in the limestone formations. In particular, resistivity tomograms in the subsided area showed the real image of ground subsidence. The map of hazardous zone has been derived from the joint interpretation of these survey results and we could provide the possible reinforcement strategy in this area.

  • PDF