• 제목/요약/키워드: CR-dimension

검색결과 54건 처리시간 0.023초

도재 냉각방법의 차이가 금속-도재간 열팽창 양상과 결합력에 미치는 영향 (INFLUENCE OF COOLING RATE ON THERMAL EXPANSION BEHAVIOR AND FLEXURAL FAILURE OF PFM SYSTEMS)

  • 임애란;임호남;박남수
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.165-191
    • /
    • 1990
  • Although a number of studies have been performed to assure that residual stress caused by a mismatch of alloy porcelain thermal expansion can contribute to clinical failure of a ceramometal restoration, the interactive influence of cooling rate on the magnitude of thermal expansion difference and on bond strength between them have not been extensively analyzed. The objective of this study was to determine the influence of cooling rate and the number of firing cycles on the expansion mismatch and the flexural failure resistance of metal porcelain strip. Tested alloys included one Pd-Ag alloy, one Ni-Cr-Be alloy with two kinds of porcelain, Vita and Ceramco. Metal specimens were cast into rods with a height of 13mm and a diameter of 5mm. Subsequently, the castings were subjected to scheduled firing cycles without porcelain. And the porcelain specimens after being fired were trimmed into a bar with a final dimension of $5{\times}5{\times}25mm$. Thermal expansions of the alloys and porcelains were measured by using a push rod or a differential dialometer respecitvely. Porcelain glass transition temperatures and expansion values were derived alloy-porcelain pairs were assessed by comparing expansion values of the components at a porcelain glass transition temperature. Calculations were made using combinations of a Ni-Cr alloy or Pd-Ag alloy with each of two porcelain products. Metal-porcelain strip specimens were subjected to four point loading in an Instron testing machine until crack occured at the metal-cramic interface at the time of sharp decrease of load on recorder. On the basis of this study, the following conclusions may be stated: 1. Regardless of the kinds of ceramometal combinations, both of calculated and experimental data revealed that the double fired specimens exhibited a significantly lower flexural strength. 2. By the rise of the amount of mismatch, bond strength were decreased. 3. Thermal expansion value of Pd-Ag alloys were higher than that of Ni-Cr alloys. 4. Expansion curves of metal were proportional to the increase of temperature and were not affected by the experimental conditions, however porcelains did not show the same magnitude of metal, and a shift of the glass transition temperature to higher temperatures was observed when cooled rapidly 5. Alloy-porcelain thermal compatibility appeared more dependent on the porcelain than the alloy.

  • PDF

도재 냉각방법의 차이가 금속-도재간 열팽창 양상과 결합력에 미치는 영향 (INFLUENCE OF COOLING RATE ON THERMAL EXPANSION BEHAVIOR AND FLEXURAL FAILURE OF PFM SYSTEMS)

  • 임애란;임호남;박남수
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.111-137
    • /
    • 1991
  • Although a number of studies have been performed to assure that residual stress caused by a mismatch of alloy porcelain thermal expansion can contribute to clinical failure of a ceramometal restoratoin, the interactive influence of cooling rate on the magnitude of thermal expansion difference and on bond strength between them have not been extensively analyzed. The objective of this study was to determine the influence of cooling rate and the number of firing cycles on the expansion mismatch and the flexural failure resistance of metal porcelain strip. Tested alloys included one Pd-Ag alloy, one Ni-Cr-Be alloy with two kinds of porcelain, Vita and Ceramco. Metal specimens were cast into rods with a height of 13mm and a diameter of 5mm. Subsequently, the castings were subjected to scheduled firing cycles without porcelain. And the porcelain specimens after being fired were trimmed into a bar with a final dimension of 5 x 5 x 25mm. Thermal expansions of the alloys and porcelains were measured by using a push rod or a differential dialometer respectively. Porcelain glass transition temperatures and expansion values were derived alloy- porcelain pairs were assessed by comparing expansion values of the components at a porcelain glass transition temperature. Calculations were made using combinations of a Ni-Cr alloy or Pd-Ag alloy with each of two porcelain products. Metal- porcelain strip specimens were subjected to four point loading in an Instron testing machine until crack occured at the metal-cramic interface at the time of sharp decrease of load on recorder. On the basis of this study, the following conclusions may be stated : 1. Regardless of the kinds of ceramometal combinations, both of calculated and experimental data revealed that the double fired specimens exhibited a significantly lower flexural strength. 2. By the rise of the amount of mismatch, bond strength were decreased. 3. Thermal expansion value of Pd-Ag alloys were higher than of Ni-Cr alloys. 4. Expansion curves of metal were proportional to the increase of temperature and were not affected by the experimental conditions, however porcelains did not show the same magnitude of metal, and a shift of the glass transition temperature to higher temperatures was observed when cooled rapidly. 5. Alloy- porcelain thermal compatibility appeared more dependent on the porcelain than the alloy.

  • PDF

Effects of Alloying Elements and Heat-Treatments on Abrasion Wear Behavior of High Alloyed White Cast Iron

  • Yu, Sung-Kon
    • 한국주조공학회지
    • /
    • 제20권2호
    • /
    • pp.104-109
    • /
    • 2000
  • Three different white cast irons alloyed with Cr, V, Mo and W were prepared in order to study their abrasion wear behavior in as-cast and heat-treated conditions. The specimens were produced using a 15㎏-capacity high frequency induction furnace. Melts were super-heated to $1600^{\circ}C$, and poured at $1550^{\circ}C$ into Y-block pepset molds. Three combinations of the alloying elements were selected so as to obtain the different types of carbides : 3%C-10%Cr-5%Mo-5%W(alloy No. 1: $M_7C_3$ and $M_6C$), 3%C -10%V-5%Mo-5%W(alloy No. 2: MC and $M_2C$) and 3%C-17%Cr-3%V(alloy No. 3: $M_7C_3$ only). A scratching type abrasion test was carried out in the states of as-cast(AS), homogenizing(AH), air-hardening(AHF) and tempering(AHFT). First of all, the as-cast specimens were homogenized at $950^{\circ}C$ for 5h under the vacuum atmosphere. Then, they were austenitized at $1050^{\circ}C$ for 2h and followed by air-hardening in air. The air-hardened specimens were tempered at $300^{\circ}C$ for 3h. 1 ㎏ load was applied in order to contact the specimen with abrading wheel which was wound by 120 mesh SiC paper. The wear loss of the test piece(dimension: $50{\times}50{\times}5$ mm) was measured after one cycle of wear test and this procedure was repeated up to 8 cycles. In all the specimens, the abrasion wear loss was found to decrease in the order of AH, AS, AHFT and AHF states. Abrasion wear loss was lowest in the alloy No.2 and highest in the alloy No.1 except for the as-cast and homogenized condition in which the alloy No.3 showed the highest abrasion wear loss. The lowest abrasion wear loss of the alloy No.2 could be attributed to the fact that it contained primary and eutectic MC carbides, and eutectic $M_2C$ carbide with extremely high hardness. The matrix of each specimen was fully pearlitic in the as-cast state but it was transformed to martensite, tempered martensite and austenite depending upon the type of heat-treatment. From these results, it becomes clear that MC carbide is a significant phase to improve the abrasion wear resistance.

  • PDF

Fabrication of MFISFET Compatible with CMOS Process Using $SrBi_2Ta_2O_9$(SBT) Materials

  • You, In-Kyu;Lee, Won-Jae;Yang, Il-Suk;Yu, Byoung-Gon;Cho, Kyoung-Ik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권1호
    • /
    • pp.40-44
    • /
    • 2000
  • Metal-ferroelectric-insulator-semoiconductor field effect transistor (MFISFETs) were fabricated using CMOS processes. The Pt/SBT/NO combined layers were etched for forming a conformal gate by using Ti/Cr metal masks and a two step etching method, By the method, we were able to fabricate a small-sized gate with the dimension of $16/4{\mu}textrm{m}$ in the width/length of gate. It has been chosen the non-self aligned source and drain implantation process, We have deposited inter-layer dielectrics(ILD) by low pressure chemical vapor deposition(LPCVD) at $380^{circ}C$ after etching the gate structure and the threshold voltage of p-channel MFISFETs were about 1.0 and -2.1V, respectively. It was also observed that the current difference between the $I_{ON}$(on current) and $I_{OFF}$(off current) that is very important in sensing margin, is more that 100 times in $I_{D}-V_{G}$ hysteresis curve.

  • PDF

$Sb_2O_3$가 첨가된 고전압 ZnO 바리스터의 미세 구조 및 전기적 특성 (The Microstructure and Electrical Characteristics of High Voltage ZnO Varistors with $Sb_2O_3$Additive)

  • 오수홍;정우성;홍경진;이진;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.369-372
    • /
    • 2000
  • ZnO varistor is studied to sintering condition and mixing condition for the improvement to non linear of electrical characteristics. In this paper, ZnO varistor, ZnO-Bi$_2$O$_3$-Y$_2$O$_3$-MnO-Cr$_2$O$_3$-Sb$_2$O$_3$series, is fabricated with Sb$_2$O$_3$mol ratio(0.5~4[mol%]) and sintered at 1250[$^{\circ}C$] for 2 hours. The grain size to Sb$_2$O$_3$moi ratio was measured by fractal mathematics. The ZnO varistors that Sb$_2$O$_3$mot ratio is 1[mol%] were shown small grain size because of spinel phase. The fractal dimension were increased with increasing of Sb$_2$O$_3$mo ratios. The capacitance of ZnO varistors with increasing of Sb$_2$O$_3$additive in voltage-capacitance characteristics was decreased by small grain size.

  • PDF

두 칼라 모델의 부분연결 다층 퍼셉트론을 사용한 피부색 검출 (Skin Color Detection Using Partially Connected Multi-layer Perceptron of Two Color Models)

  • 김성훈;이현수
    • 전자공학회논문지CI
    • /
    • 제46권3호
    • /
    • pp.107-115
    • /
    • 2009
  • 피부색 검출은 피부색과 비피부색에 대한 분류기가 사용되며, 분류 성능이 높은 분류기가 필요하다. 기존의 피부색 검출을 위한 분류기들은 대부분 하나의 칼라 모델을 사용하고 있다. 그러나 칼라 모델에 따라 피부색의 분포 특성이 다르기 때문에 하나 이상의 칼라 모델을 사용함으로써 분류 성능을 높일 수 있다. MLP(Multi Layer Perceptron)는 다른 분류기보다 적은 파라미터를 사용하면서 좋은 분류 성능을 보이고 있다. 하지만 두 개의 칼라 모델을 사용할 경우 MLP의 입력 차원이 증가되기 때문의 파라미터 수가 증가되는 문제가 발생하게 되며, 파라미터 수의 증가는 MLP의 학습 시간이 증가되는 원인이 된다. 따라서 본 논문에서는 두 칼라 모델의 구성 성분을 조합함으로써 피부색과 비피부색의 분류 성능을 향상시키고, 적은 수의 파라미터가 사용된 피부색 검출 방법을 제안한다. 제안한 부분 연결 MLP는 각 칼라 모델에 따라 연결 강도를 부분적으로 연결함으로써 연결 강도의 수를 감소 시켰으며, 각 부분 네트워크에 서로 다른 칼라 모델의 특성을 학습시킴으로써 분류율을 향상시킬 수 있다. 실험 결과 제안한 부분연결 MLP를 RGB와 CbCr 칼라 정보로 구성했을 때 91.8%의 분류율을 달성하였다.

스테레오 비젼 기반의 능동형 물체 추적 시스템 (Active Object Tracking System based on Stereo Vision)

  • 고정환
    • 전자공학회논문지
    • /
    • 제53권4호
    • /
    • pp.159-166
    • /
    • 2016
  • 본 논문에서는 지능적인 보안 시스템 구현의 새로운 접근 방식으로, 인공지능형 시각 시스템에 기반한 팬/틸트 탑재형 스테레오 카메라의 기하학적 정보를 이용한 능동형 물체 추적 시스템을 제안하였다. 제안된 시스템에서는 먼저, 스테레오 카메라에서 입력된 영상으로 부터 YCbCr 컬러 모델과 위상형 상관 기법을 사용하여 표적 얼굴영역의 중심좌표를 검출한 다음, 지능형 시각 시스템에 기반한 팬/틸트 탑재형 스테레오 카메라의 능동적인 제어각도 산출을 통해 표적의 다양한 변화에 관계없이 표적의 3차원 좌표를 실시간적으로 검출하고, 이를 통한 표적 대상의 적응적인 신체 크기 추정을 수행하였다. 각기 다른 신장을 가진 3사람의 다양한 이동경로를 가진 480 프레임의 테스트용 스테레오 영상을 사용한 실험 결과, 표적의 추정된 신체 크기값 역시 계산치 및 측정치 사이의 표준편차가 평균 1.03의 작은 값으로 유지됨은 물론, 제안된 시스템에서 계산된 좌표값과 실제 실험대상으로 참여한 사람의 정확한 실제 위치와의 차이 역시 평균 1.2cm 미만의 오차와 전체적으로 1.18 %의 오차를 보임으로써 이를 통한 새로운 실시간 스테레오 표적 감시추적 시스템의 구현 가능성을 제시하였다.

Analysis of in vitro 2D-COSY on Human Brain Metabolites for Molecular Stereochemistry

  • Kim, Sang-Young;Woo, Dong-Cheol;Bang, Eun-Jung;Kim, Sang-Soo;Lim, Hyang-Sook;Choi, Chi-Bong;Choe, Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제12권1호
    • /
    • pp.14-25
    • /
    • 2008
  • To investigate the 3-bond connectivity of human brain metabolites by scalar coupling interaction through 2D-correlation spectroscopy (COSY) techniques using high field NMR spectroscopy. All NMR experiments were performed at 298K on Unity Inova 500 or 600 (Varian Inc.) equipped with a triple resonance probe head with z-shield gradient. Human brain metabolites were prepared with 10% $D_2O$. Two dimensional 2D COSY spectra were acquired with 4096 complex data points in $t_2$ and 128 or 256 increments in $t_1$ dimension. The spectral width was 9615.4 Hz and solvent suppression was achieved using presaturation using low power irradiation of the water resonance during 2s of relaxation delay. NMR data were processed using VNMRJ (Varian Instrument) software and all the chemical shifts were referenced to the methyl resonance of N-acetyl aspartate (NAA) peak at 2.0 ppm. Total 10 metabolites such as N-acetyl aspartate (NAA), creatine (Cr), choline (Cho), glutamine (Gln), glutamate (Glu), myo-inositol (Ins), lactate (Lac), taurine (Tau), ${\gamma}$-aminobutyricacid (GABA), alanine (Ala) were included for major target metabolites. Symmetrical 2D-COSY spectra were successfully acquired. Total 14 COSY cross peaks were observed even though there were parallel/orthogonal noisy peaks induced by water suppression. Except for Cr, all of human brain metabolites produced COSY cross peaks. The spectra of NAA methyl proton at 2.02 ppm and Glu methylene proton ($CH_2(3)$) at 2.11 ppm and Gln methylene proton ($CH_2(3)$) at 2.14 ppm were overlapped in the similar resonance frequency between 2.00 ppm and 2.15 ppm. The present study demonstrated that in vitro 2D-COSY represented the 3-bond connectivity of human brain metabolites by scalar coupling interaction. This study could aid in better understanding the interactions between human brain metabolites in vivo 2D-COSY study. Also it would be helpful to determine the molecular stereochemistry in vivo by using two-dimensional MR spectroscopy.

트랜스 리비도 경제학 - Homo surplus (Titre- l'économie trans libidinale-homo surplus)

  • 윤지영
    • 철학연구
    • /
    • 제126권
    • /
    • pp.191-212
    • /
    • 2013
  • 이 논문은 기존 욕망의 경제학이 남근 질서에 대한 예속성에서 벗어나있지 못함으로써 리비도 흐름들의 절단과 국소화 작업에 치우쳐 왔음을 비판하며 시작한다. 라캉의 욕망 개념이 결핍과 거세에 한정되어왔기에 리비도 흐름들의 산발성과 표류, 탈주의 가능성과 더불어, 잉여와 과잉이라는 초과성 개념을 제대로 담아내지 못하고 있다. 이러한 거세의 법에 포박된 욕망 개념을 넘어서는 생성과 생산으로서의 욕망 개념인 들뢰즈와 가타리의 논의에서 보다 나아가 homo surplus 잉여적 인간 개념을 창출해 보려 하였다. 미리 주어진 규준틀 자체를 넘어서 버리는 과잉성과 비 측량성으로서의 잉여 개념이 어떻게 남근 질서로부터의 분리와 해체를 가능케 하는지에 주목한다. 그리고 기관 쾌락이라는 제 2세대 재생산을 위한 국소적이며 합목적적, 기능주의적 쾌락 개념의 한계를 날카로이 드러내며, 쥬이상스(jouissance)라는 비남근적 향유가 감각 다발의 재배치라는 급진적 성적 실천으로 이어질 수 있는가를 면밀히 분석해 나갈 것이다.

미소 유량 측정을 위한 마이크로 전자 유량 센서의 제작 (Fabrication of a Micro Electromagnetic Flow Sensor for Micro Flow Rate Measurement)

  • 윤현중;김순영;양상식
    • 센서학회지
    • /
    • 제9권5호
    • /
    • pp.334-340
    • /
    • 2000
  • 본 논문에서는 패러데이의 전자기 유도 법칙을 응용한 마이크로 전자 유량 센서를 제작하였다. 마이크로전자 유량 센서는 열 발생이 없고 빠른 응답 속도를 가지고 있고 압력 손실이 없는 장점을 가지고 있다. 전도성 유체가 영구 자석 자장 내의 유로를 통과할 때, 유속에 비례하는 유도 기 전력이 발생하게 되는데, 발생된 기 전력은 유로 벽에 제작된 전극으로 검출된다. 마이크로 전자 유량 센서는 유로를 가지고 있는 두 장의 실리콘 웨이퍼 기판과 전극, 그리고 두 개의 영구 자석으로 구성되어 있다. 두 장의 실리콘 웨이퍼 기판을 이방성 식각 공정으로 유로를 제작하고, Cr/Au를 증착하여 전극을 제작한다. 제작된 마이크로 전자 유량 센서에 유량을 변화시킬 때, 발생되는 기 전력을 측정한다.

  • PDF