• Title/Summary/Keyword: CR-39 plastic

Search Result 11, Processing Time 0.02 seconds

Measurement of Radon-222 Exhalation Rate from Building Materials by Using CR-39 Radon Cup (CR-39 라돈컵을 이용한 국산 전축자재의 라돈-222 방출율 측정)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.15-24
    • /
    • 1991
  • Radon-222 exhalation rate from several domestic building materials were experimentally measured by using radon cup method, in which a CR-39 plastic is used as a passive radon detector. The radon detection factor of CR-39 detector determined in a series of calibration experiments was $0.164{\pm}0.005(tracks\;cm^{-2}/Bq\;d\;m^{-3})$, which is consistent with those reported by other investigators. The radon exhalation rates of several building materials (brick, red brick, concrete block, granite plate, concrete floor and wall) ranges from $6.8{\times}10^{-6}\;(granite plate)\;to\;75.0{\times}10^{-6}Bq/m^2-sec(brick)$ with the increasing order of granite plate, red brick, concrete wall, concrete block, concrete floor and brick. It showed that the CR39 radon cup can be efficiently utilized in measuring the radon-222 gas exhalation rate from building materials.

  • PDF

The Usefulness of the Endonasal Incisional Approach for the Treatment of Nasal Bone Fracture

  • Kim, Hyo-Seong;Suh, Hyeun-Woo;Ha, Ki-Young;Kim, Boo-Yeong;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.209-215
    • /
    • 2012
  • Background : Among all facial fractures, nasal bone fractures are the most common, and they have been reduced by closed reduction (CR) for a long time. But several authors have reported suboptimal results when using CR, and the best method of nasal bone reduction is still being debated. We have found that indirect open reduction (IOR) through an endonasal incisional approach is a useful method for more accurate reduction of the nasal bone. Methods : A retrospective chart review was performed of 356 patients who underwent reduction of a nasal bone fracture in our department from January, 2006, to July, 2011. We treated 263 patients with IOR. We assessed patients' and doctors' satisfaction with surgical outcomes after IOR or CR. We evaluated the frequency of nasal bleeding owing to mucosal injury, and followed the surgical outcomes of patients who had simultaneous dorsal augmentation rhinoplasty. Results : According to the analysis of the satisfaction scores, both patients and doctors were significantly more satisfied in the IOR group than the CR group (P<0.05). Mucosal injury with nasal bleeding occurred much less in the IOR group (5.3%) than the CR group (12.9%). Dorsal augmentation rhinoplasty with IOR was performed simultaneously in 34 cases. Most of them (31/34) showed satisfaction with the outcomes. Conclusions : IOR enables surgeons to manipulate the bony fragment directly through the endonasal incisional approach. However, we propose that CR is the proper technique for patients under 16 and for those with comminuted nasal bone fractures because submucosal dissection in IOR can damage the growth or circulation of nasal bone.

Analysis of Absorbance for Tinted Dye Absorbed into Tinted Lenses by Spectrophotometric Method (분광광도법에 의한 칼라 렌즈 내 염색제에 대한 흡광도 분석)

  • Choi, Eun-Jung;Jung, Ju-Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.704-708
    • /
    • 2009
  • We studied absorbance of tinted dye absorbed into tinted lenses by Spectrophotometric method. Used lenses and tinted dye were CR-39 plastic optical lenses and Ons & $Lavas^{(R)}$ Blue, respectively. Absorbance values of tinted dye absorbed into tinted lenses were obtained from the differences of absorbance values between tinted lenses and CR-30 lenses. Average concentrations of tinted dye absorbed into tinted lenses were obtained from the mass differences between tinted lenses and CR-30 lenses. The relationship between absorbance and average concentration for tinted dye absorbed into tinted lenses was also confirmed to follow Beer’s law. The absorption coefficient calculated from the tangent of the calibration curve was determined to be a=0.983 $Lg^{-1}cm^{-1}$.

Evaluation of Ultraviolet Blocking of Ophthalmic Lenses (안경렌즈의 자외선 차단 평가)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.7-12
    • /
    • 2008
  • Purpose: To evaluate ultraviolet (UV) blocking characteristics of transparent and tinted ophthalmic lenses. Methods: The transmittance spectra of ophthalmic lenses were measured using the method suggested in ANSI Z80.1 standard. Transmittance percentage were calculated for each lens for UV (200~380 nm; UVA, UVB, UVC) and blue light portions (380~400 nm) of spectrum. Results: The results indicate that transparent plastic lenses with middle, high refractive index and tinted plastic lenses had superior UV blocking characteristics at UV radiation while UV blocker-untreated lenses such as crown glasses and CR39 did not. All except high refractive index lenses and anti-glare night vision lens was not effectively blocked blue light. Conclusions: Crown glass and CR39 lenses need to treat UV blockers to protect eyes from UV. Also, all lenes except high refractive index lenses and anti-glare night vision lens need to treat blue light blockers for protecting from blue light.

  • PDF

Changes of the Plastic Lens Properties Caused by Etching of the Coating Films (코팅막 식각으로 인한 플라스틱 렌즈의 특성 변화)

  • Moon, Byeong-Yeon;Hwang, Ki Ju;Lee, Yoon Jeong;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: We investigated the changes of plastic lens after etching of coating films by comparing uncoated lens. Methods: CR-39, middle index and high index lenses of 0 (zero) diopter were etched at $80^{\circ}C$ and room temperature using a coating remover, and then changes of refractive power, transmittance and surface morphology were investigated. Results: There were no differences in refractive power and transmittance between uncoated and etched lenses. The etching rate was similar in both CR-39 and middle index lens, but in the case of high index lens, it was slower and less steady than the others. From the SEM observation of lens surface, etching damage was found out on the surface of etched lens. It was shown the least damage in middle index lens but the most damage in high index lens. Conclusions: If the etching of coating films is demanded on condition that the surface of ophthalmic lenses are not damaged, a using of most adequate coating remover based on lens material should be considered, and a caution for proper etching conditions is required.

Dosimetry of $^{222}Rn$ Component in Outdoor Natural Background Radiation (자연 방사선량 중 $^{222}Rn$기여 성분 정량 해석)

  • Jun, Jae-Shik;Oh, Hi-Peel;Chae, Ha-Suk;Lee, Byung-Young;Kim, Do-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.10-17
    • /
    • 1989
  • A study for the assessment of dose given by outdoor radon to respiratory system has been carried out by making use of radon-cups containing CR-39 plastic track detectors. Detection efficiencies were determined by irradiation of the radon-cups in a standard radon chamber of known concentration. Thus determined detection factors of CR-39 plastic track detector in bare, open cup and filtered cup geometry are found to be 0.273, 0.0813 and 0.0371 $trmm^{-2}$/(37$Bqm^{-3}{\cdot}d$), respectively, which are chemically etched in 30% NaOH solution of $70^{\circ}C$ for 220 minutes. The outdoor radon concentrations measured at Taejeon(Chungnam National University) from May 1988 to March 1989 are in the range of 27.4 - 135.8 Bq/$m^3$(0.74 - 3.67pCi/l)by open cup and 16.7 - 143.9 Bq/$m^3$(0.45 - 3.89 pCi/l) by filtered cup, which yield overall annual average value of outdoor radon concentration of $70.8Bq/m^3$(1.91 pCi/l). Corresponding effective dose equivalent rate to respiratory system of ICRP standard man is assessed to be 520 nSv /h.

  • PDF

Evaluation of Bonding Performance of Hybrid Materials According to Laser and Plasma Surface Treatment (레이저 및 플라즈마 표면처리에 따른 이종소재 접합특성평가)

  • Minha Shin;Eun Sung Kim;Seong-Jong Kim
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.441-447
    • /
    • 2023
  • Recently, as demand for high-strength, lightweight materials has increased, there has been great interest in joining with metals. In the case of mechanical bonding, such as bolting and riveting, chemical bonding using adhesives is attracting attention as stress concentration, cracks, and peeling occur. In this paper, surface treatment was performed to improve the adhesive strength, and the change in adhesive strength was analyzed. For the adhesive strength test were conducted with Carbon Fiber Reinforced Plastic(CFRP), CR340(Steel), and Al6061(Aluminum), and laser and plasma surface treatment were used. After plasma surface treatment, the adhesive strength improved by 7.3% and 39.2% in CFRP-CR340 and CFRP-Al6061, respectively. CR340-Al6061 was improved by 56.2% in laser surface treatment. Surface free energy(SFE) was measured by contact angle after plasma treatment, and it is thought that the adhesion strength was improved by minimizing damage through a chemical reaction mechanism. For laser surface treatment, it is thought that creates a rough bonding surface and improves adhesive strength due to the mechanical interlocking effect. Therefore, surface treatment is effect to improve adhesive strength, and based on this paper, the long-term fatigue test will be conducted to prevent fatigue failure, which is a representative cause of actual structural damage.

Evaluation and Analysis of Composition of Shredder Residue from End-of-life Vehicle (폐자동차 차피파쇄잔류물의 組咸에 대한 分析評價硏究)

  • 오종기;이화영;김성규
    • Resources Recycling
    • /
    • v.10 no.4
    • /
    • pp.34-41
    • /
    • 2001
  • A research was performed to evaluate a use of shredder residue to currently dispose of at landfills. Laboratory analyses were conducted to determine especially the fuel characteristics of shredder residue. For this aim, shredder residue was classified by the particle size as well as by the type of material and the content of Cl, S, ash, and calorific value were determined. Due to the chlorinated plastic content of shredder residue, mean concentration of Cl was found to exceed 4wt% except one sample while that of S was ranged from 0.25 to 0.39 wt%. As far as calorific value was concemed, plastic was observed to be more than 10,000 kcal/kg while wood/paper and fiber accounted for approximately 4,000 kcal/kg. Shredder residue was found to contain varying trace amounts of metal elements, including Fe of 6∼8.5 wt%. Hg and Cr(VI) were not detected, however, while Cd was contained as small as 0.0004-0.0009 wt%.

  • PDF

Radon Measurement by Alpha Particle Track Method (Alpha 입자비적법(粒子飛跡法)에 의(依)한 Radon 측정(測定))

  • Kang, Yung-Ho;Park, Jang-Sick;Kim, Do-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.17-22
    • /
    • 1982
  • Measurement of the radon concentration close to the ground surface can be used in search of environmental radiation for human safety, exploration for uranium, premonitory signals from earthquakes. We can detect radons in soil gas by alpha particle track method using the plastic track detectors, cellulose nitrate (LR115-Type 2 and CA80-15, Kodak $Path\'{e}$) and CR-39. For present works, radon cups having these detectors were made in our laboratory and their conversion factor was determined. A typical conversion factor was $1tr/cm^2{\cdot}30days=1.2{\times}10^{-2}pCi/l$. In the radon cups, some of $CaSO_4$ were used as desiccant for reducing the moisture effects on plastic track detectors. With these radon cups, underground radon concentrations of Kyungpook area were measured. Average radon concentration in Daegu from Jan. 1981 to Feb. 1982 was 39.7pCi/l. From Aug. 1981 to Feb. 1982, average radon concentrations of Daegu, Angang, Kyungju, Pohang, Chungha, and Andong were 31.8pCi/l, 124.5pCi/l, 127.0pCi/l, 79.1pCi/l, 144.4pCi/l, and 70.9pCi/l, respectively. The results were compared with the environmental radiation measured by TLD method.

  • PDF

초음파 진동절삭에 의한 광학 플라스틱의 미소표면성상 분석

  • 최인휴;김정두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.115-120
    • /
    • 1992
  • Mirror-surface machining is very important machining technology to manufacture optical parts. especially brittle materials. In case of optical plastics, it is produced through both grinding and polishing till now. New machining method which is more efficient and contributed to the protection of the environmental pollution is, therefore, studied. In this , experimental results and an analysis of surface roughness in ultrasonic vibration cutting of optical plastic (CR-39) which is used for optical lens is presented. In results, a comparison of the micro-structure of machined surfaces produced by cutting with ultrasonic vibration and conventional turning is presented by analyzing S.E.M. photograph. Also, wavelength spectrum analysis is performed to investigate the surface-characteristics machined by ultrasonic vibration cutting.