• Title/Summary/Keyword: CR 요소

Search Result 188, Processing Time 0.027 seconds

Finite Element Analysis on Stress Distribution in Base Metal-Ceramic Crown Margin Designs (유한요소법을 이용한 비귀금속-도재관 변연부 형태에 따른 응력 분포 분석)

  • Lee, Myung-Kon;Shin, Jung-Woog;Kim, Myung-Duk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.79-88
    • /
    • 2000
  • The objective of this finite element method study was to analyze the stress distribution induced in a maxillary central incisor Ni-Cr base metal coping ceramic crowns with various margin design. Margin designs of crown in this experiment were knife-edge metal margin on chamfer finishing line of tooth preparation(M1), butt metal margin on shoulder finishing line(M2), reinforced butt metal margin on shoulder finishing line(M3), beveled metal margin on bevelde shoulder finishing line(M4). Two- dimensional finite element models of crown designs were subjected to a simulated biting force of 100N which was forced over porcelain near the lingual incisal edge. Base on plane stress analysis, the maxium von Miss stresses(Mpa) in porcelain venner was 0.432, in metal coping was 0.579, in dentin abutment was 0.324 for M1 model, and M2 model revealed in porcelain was 0.556, in metal coping was 0.511, in dentin was 0.339, and M3 model revealed in porcelain was 0.556, in metal coping was 0.794, in dentin was 0.383 for M4 model. All values of each material in metal-ceramic crown were much below the critical failure values.

  • PDF

Assessment of Material Properties Using Finite Element Analysis for Small Punch Creep Testing (SP 크리프 시험의 유한요소해석을 이용한 재료물성 평가)

  • Park, Tae-Kyu;Ma, Young-Wha;Yoon, Kee-Bong;Jeong, Ill-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.511-516
    • /
    • 2001
  • Recently small punch creep testing (or miniature disc bend creep test) has received much attention through European collaborative research projects. This method was considered as a substitute for the conventional creep rupture testing by which the residual creep life is measured from the specimen taken out from serviced components of high temperature plants. It would be beneficial if the material creep properties such as power law creep constants as well as the creep rupture life can be measured from the small punch creep test. In this paper a method of assessing creep constants from the small punch creep testing is proposed. Finite element analyses were performed to investigate evolution of stress and strain rate at the weakest locations of the small punch creep specimen. Elastic-plastic-secondary creep analyses were carried out. The estimation equations for creep constants by the small punch creep testing are proposed based on the finite analysis results. Small punch creep tests were also performed with 9Cr steel and the accuracy of the proposed equation was verified by the experimental results.

  • PDF

Interworking Mechanism for QOS support Between MPLS and DS (ATM 기반의 MPLS 네트워크에서 QOS 를 보장하는 MPLS 와 DS 연동 메커니즘)

  • Song, Ye-Jin;Seok, Seung-Joon;Kang, Chul-Hee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.686-691
    • /
    • 2000
  • 최근 들어 인터넷의 사용이 급격히 증가함에 따라 인터넷의 백본망에는 패킷 전달의 고속성, 확장성 뿐만 아니라 QOS 보장을 요구하게 되었다. 효과적인 인터넷 백본망을 구현하기 위해 본 논문에서는 Multi-Protocol Label Switching(MPLS)를 고려하고 MPLS 에서 인터넷 Quality Of Service(QOS) 서비스 모델 중 백본망에 적합한 Differentiated Service(DS) 모델을 그대로 제공하기 위해 MPLS 와 DS 의 연동에 대한 문제를 다룬다. 우선 MPLS 에서 QOS 제공을 위한 기능요소를 정성적으로 분석한다. 그리고 두 DS 망 가운데 ATM 기반의 MPLS 망을 두고 있는 경우를 가정하여, 종단대 종단간 DS 제공을 위하여 DS 망과 MPLS 망에서의 시그널링 과정을 제안한다. 즉, DS 의 BB 로부터 SLA 를 위한 신호를 MPLS 의 입구 라우터에서 해석하여 DS Type-Length-Value(TLV)를 만들고 이를 이용하여 Constraint-based Label Distribution Protocol(CR-LDP) 시그널링을 통해 마다 Label-Only-Inferred-PSC LSP(L-LSP)를 설립하여 MPLS 에서 DS QOS 를 그대로 제공한다. 또한 입구 DS BB 로부터의 정보를 MPLS 망을 통해 BB 에게 보낸다.

  • PDF

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

개방형 문제를 활용한 평가가 수학적 창의력에 미치는 효과

  • Byeon, Eun-Jin;Jeon, Pyeong-Guk
    • Communications of Mathematical Education
    • /
    • v.11
    • /
    • pp.259-277
    • /
    • 2001
  • 본 연구는 개방형 문제를 활용한 평가가 수학적 창의력에 미치는 효과를 분석함으로써 수학적 창의력을 신장시킬 수 있는 평가 방법을 찾는데 그 목적이 있다. 이를 위해 대구광역시 소재의 C중학교 2학년 1개반과 S중학교 2학년 1개반을 임의로 선정하여 한 반은 개방형 문제를 활용한 평가 집단으로 하고 다른 한 반은 전통적 평가 집단으로 무선 할당하여 실험연구를 실시하였다. 실험처치는 두 집단에게 서로 다른 유형의 평가를 실시하는 것으로, 실험집단은 개방형 문제를 평가과제로 하여 실험집단 담임 교사가 평가를 실시하였으며, 비교집단은 객관식 및 주관식 단답형 문제를 평가과제로 하여 비교집단 담임교사가 전통적인 평가를 실시하였다. 본 연구에서 사용한 검사도구는 수학적 창의력 검사로 사전 사후검사 모두 같은 검사지를 사용하였다. 사후 수학적 창의력 검사의 평균의 차를 t-검정한 결과 유의도p=.025(p < .05)로 실험집단과 비교집단 사이에는 통계적으로 유의미한 차가 있는 것으로 나타났다. 수학적 창의력의 각 요소별로 차이가 있는지 알아보기 위해 사후 창의력 검사의 각 요소별로 평균의 차를 t-검정한 결과, 유창성과 융통성은 각각 유의도 p=.030, p=.040으로 p < .05 수준에서 통계적으로 유의미한 차이가 있었으며, 독창성은 유의도 p=.052로 p < .1 수준에서 통계적으로 유의미한 차이를 보였다. 연구결과 개방형 문제를 활용한 평가가 전통적 평가보다 수학적 창의력 향상에 더 효과적이며, 수학적 창의력의 세 가지 요소(유창성, 융통성, 독창성)의 향상에도 효과적인 것으로 나타났다. 결론적으로 개방형 문제를 활용한 평가가 수학적 창의력 신장에 효과적인 방법임을 시사한다.질공학적 특성의 위도별, 깊이별 변화는 탄산질 퇴적물과 규질 퇴적물의 분포, 수층의 생산성 및 수심변화에 따른 용해도와 퇴적을 차이 그리고 침식 및 재퇴적작용 등 퇴적 과정이 위도별로 달랐기 때문으로 판단된다.haetoceros resting spores/Chaetoceroe vegetative cells도 80 cm 보다 상층에서는 높게 나타나 규조온도지수 분포와도 일치하는 경향을 보인다. 이상의 규조군집 분석 결과에 의하면, 홀로세의 후빙기동안 본 연구 지역인 동해 북동부에는 대마 난류의 유입이후 현재와 유사한 환경이 우세하게 발달했으나, 난류종 P. doliolus의 변화는 동해내에서 대마난류의 세기가 반복되었음을 지시하고 있다./3 수준으로 높다. 결론적으로 풍부한 화학물질들을 함유한 제주해류는 남해 및 동해의 생지화학적 과정들에 있어 상당히 중요함을 시사한다.다. 수조 상층수 중 Cu, Cd, As 농도는 모든 FW, SW수조에서 시간이 지남에 따라 일관성 있게 감소하였고, 제거속도는 Cu가 다른 원소에 비해 빨랐다. 제거속도는 FW 3개 수조 중 FW5&6에서 세 원소 모두 가장 느렸고, SW 3개 수조 중에서는 SW1&2에서 가장 빨랐다. SW와 FW간 제거속도 차이는 세 원소 모두 명확치 않았다 Cr은 FW에서 전반적으로 감소하는 경향을 보였지만 SW에서는 실험 초기에 감소하다 24시간 이후에는 증가 후 일정한 양상을 보였다. Pb은 FW에서 전반적으로 감소했지만 SW에서는 초기에 급격히 증가 후 다시 급격히 감소하는 양상을 보였다 Pb 또한 Cu, Cd, As와 마찬가지로 SW1&2에서 제거속도가 가장 빠르게 나타났다. FW 상층수 중 Hg는 시간에 따라 급격히 감소했고,

  • PDF

The Characteristics of Heavy Metal Accumulations in Feral Pigeon (Columba livia) Feathers for Environmental Monitoring (환경모니터링을 위한 집비둘기 깃털의 중금속 축적특성 연구)

  • Lee, Jangho;Lee, Jongchun;Lee, Sang Hee;Kim, Myungjin;Lee, Eugene;Han, Areum;Shim, Kyuyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.6
    • /
    • pp.492-504
    • /
    • 2014
  • Feral pigeon (Columba livia) has been known as a good indicator for accumulations of chemical pollutants in urban areas. However, it is against the animal rights to kill the indicator species in order to monitor pollutants accumulations in wild birds. Eggs and feathers of birds, therefore, have been used as non-invasive monitoring materials. Even though eggs are a good indicator for accumulations of lipophilic pollutants, but unsuitable for some heavy metals such as lead and cadmium because bird's ovary builds a sort of barrier to inhibit higher accumulations of some heavy metals in the eggs. Therefore, feathers instead of eggs have been used as a non-invasive indicator for accumulations of heavy metals. However, there are few studies of heavy metal accumulations of feral pigeon in Korea. In this study, we characterized the characteristics of heavy metal accumulations of feathers in relation to internal organs (bloods, viscera and bones) in feral pigeons between two sites (Hangang Park representing urban area and Hampyeong Park for rural area). The samples from the Hangang Park showed significantly higher lead (Pb) concentrations in the blood, liver and bone than those from Hampyeong Park. The Pb concentration in the feathers was also significantly higher at Hangang Park than at Hampyeong Park. The analytical result for the breast, wing and tail feathers, and the internal organs (blood, lung, liver, kidney and bone) indicated that the Pb concentrations in the feathers were significantly positively correlated with the levels in the kidney and bone. Overall, feathers of feral pigeon may be candidate for bioindicator to monitor for Pb accumulations in urban areas.

Comparison of Blood and Urine Renal Indices Between Hypercalciuric and Non-hypercalciuric Hematuria Patients (혈뇨 환아에서 고칼슘뇨군과 비고칼슘뇨군의 혈액 및 소변화학검사와 신기능 지표들의 비교)

  • Lee, Jin-Hee;Lee, Hyun-Seung;Lee, Keun-Young;Jang, Pil-Sang;Lee, Kyung-Yil;Kim, Dong-Un
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.168-177
    • /
    • 2007
  • Purpose : The purpose of this study was to investigate whether hypercalciuria patients with hematuria show different renal indices compared to non-hypercalciuria patients with hematuria. Methods : We retrospectively reviewed the medical records of patients with gross or microscopic hematuria whose blood chemistry and 24 hour urine chemistry were examined. After excluding the patients with more than $4 mg/m^2/day$ proteinuria or the patients with urinary calcium excretion between 3 and 4 mg/kg/day, we divided the patients into two groups: a hypercalciuria group whose calcium excretion was more than 4 mg/kg/day(n=30) and a non hypercalciuria group whose calcium excretion was less than 3 mg/kg/day(n=41). The urinary excretion, clearance, and fractional excretion(FE) of Na, K, Cl, Ca, P, urea, and creatinine were calculated and compared between the two groups. Results : The hypercalciuria group had more calcium excretion($6.1{\pm}2.9$ vs $1.5{\pm}0.9 mg/kg/day$), more urea excretion($341{\pm}102$ vs $233{\pm}123 mg/kg/day$), greater glomerular filtration rate(GFR) ($93.7{\pm}31.1$ vs $79.5{\pm}32.0 mL/min$) but lower FENa($1.0{\pm}0.4%$ vs $1.3{\pm}0.6%$) than the nonhyper-calciuria group, although the urinary sodium excretion was similar between the two groups. Conclusion : The greater urea excretion and GFR in hypercalciuric patients suggest that they might be on a higher protein diet than the non-hypercalciuria group. The increased glomerular filtration of sodium and calcium induced by the higher GFR in hypercalciuria would have increased their delivery to the distal tubule, where sodium is effectively reabsorbed but calcium is not, which is suggested by the lower FENa but higher FECa in hyercalciuria. It is recommended that the diet of hematuria patients be reviewed in detail at initial presentation and during treatment.

  • PDF

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

Comparison Study on CNR and SNR of Thoracic Spine Lateral Radiography (흉추 측면검사 영상의 CNR과 SNR 측정의 비교 연구)

  • Kim, Ki-Won;Min, Jung-Whan;Lyu, Kwang-Yeul;Kim, Jung-Min;Jeong, Hoi-Woun;Lee, Joo-Ah;Jung, Jae-Hong;Sung, Dong-Chan;Park, Soon-Cheol
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.273-280
    • /
    • 2013
  • This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

Applied Mineralogy for the Conservation of Dinosaur Tracks in the Goseong Interchange Area (35번 고속도로 고성 교차로 지역 공룡발자국의 보존을 위한 응용광물학적 연구)

  • Jeong Gi Young;Kim Soo Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.189-199
    • /
    • 2004
  • Cretaceous sedimentary rocks bearing dinosaur tracks in the Goseong interchange area were studied for their conservation and public display in the aspect of applied mineralogy. Black clay layers alternate with silt layers in the sedimentary rocks. The verical and horizontal fissures are commonly filled with calcite veinlets, supergenetic iron and manganese oxides. The rocks are composed of quartz, albite, K-feldspar, calcite, chlorite, illite, muscovite, and biotite, with minor apatite and rutile. Silt layers are relatively rich in calcite and albite, whereas clay layers are abundant in quartz, illite, and chlorite. Al, Fe, Mg, K, Ti, and P are enriched in the clay layers, while Ca, Na, and Mn in silt. Most of trace elements including V, Cr, Co, Ni, Cs, Zr, REE, Th, and U are enriched in clay layers. Inorganic carbon are present in silt layers as calcite, while organic carbon in black clay layers. The black clay layers were partly altered to yellow clay layers along the fissures, simultaneously with the decrease of organic carbon. Selective exfoliation of clay-rich black and yellow clay layers, calcite matrix of silt layers and calcite infillings of fissures are estimated as the major weakness potentially promoting chemical and physical degradation of the track-bearing rock specimens.