• Title/Summary/Keyword: CQ method

Search Result 38, Processing Time 0.027 seconds

Does Cultural Intelligence enhance Export SME's Capability for Utilizing Foreign Market Informations? (문화 인텔리전스는 수출중소기업의 해외시장정보 활용능력을 키우는가?)

  • Hong, Songhon
    • International Commerce and Information Review
    • /
    • v.19 no.1
    • /
    • pp.127-152
    • /
    • 2017
  • One of the biggest challenges in export activities of SME is the increasingly cultural diversity that requires especially export managers to adapt their doing business in many different kinds of cross-cultural situations effectively. A relative newly developed concept 'Cultural Intelligence' has been evaluated as a key element for the success in international business activities. This study aims to investigate empirically the role of Cultural Intelligence(CQ), one component of cultural competence, on export marketing adaptation. The statistical method used to test the hypotheses was Structural Equation Modeling using PLS. The results of this study are follows. The moderating role of Cultural Intelligence between information seeking and information using abilities is more stronger in marketing rather than relationship adaptation. Cultural Intelligence moderates between them. Critical factors affecting Cultural Intelligence are also discussed; foreign language fluency, business travels in abroad, characteristics of the business travels, multi-lingual ability, pre-education related cultural subjects, and visit experience in foreign countries. Especially, export managers' foreign language ability leads to much stronger influence on cultural intelligence. The result of the empirical study provides important implications for export SME and export supporting organizations. Export firms and supporting organizations must expand programs widely in multi cultural training and education to help managers gain a better understanding in a various export environment.

  • PDF

Phonatory Caracteristics of Vwels and Resonant Consonants using the Electroglottography (전기성문파형검사를 이용한 모음과 공명 자음의 발성특성)

  • Choi, Seong-Hee;Nam, Do-Hyun;Lim, Jae-Yol;Lim, Sung-Eun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.133-140
    • /
    • 2004
  • Background and Objectives : Vowels and resonant including nasals and liquid are produced with vocal folds vibration have been used for voice therapy of hyperadduction patients. This study was conducted to investigate phonatory characteristics of vowels and resonant consonants through the EGG measures from Lx. Speech studio (Laryngograph Ltd, UK). Materials and Method : 7 male adults produced sustained vowel /a/, /i/, /u/, nasals /m/, /n/, /${\eta}$/and liquid /I/ and read the sentences (1nasals-liquid sentence, 1 non-nasals-liquid sentence) and tongue-tip trill and humming. Fx(Hz), Ox(%) were obtained of vowels, nasals, liquid and each of the posterior vowel /a/ of /ma/, /na/, /la/, /ha/ with same F0(around F#165Hz) and amplitude (75${\pm}$5db). And also DFx(Hz), DQx(%), CFx(%) and CAx(%) were obtained from reading two kinds of sentences. Results : Qx(%) was the highest in /u/ of vowels, and nasal/n/ of the resonant consonants and nasals-liquid sentence was higher Qx than non-nasals-liquid sentence but significant differences were not found. Qx(%) of the posterior vowel /a/ of nasal consonants/n/ was higher than in the isolated vowel/a/ and other posterior vowel of resonant consonants and fricatives /h/. Regularity or periodicity and higher Qx were observed in the nasals-liquid sentence than non-nasals-liquid sentence in graphs of QxFx & CFx produced by Quantiative analysis. In the nasalance score, /u/vowel was significant higher among the vowels and /I/ liquid was significant lower among the resonant consonants and nasals-liquid sentence is higher than non-nasals -liquid sentence. CQ(%) was not significantly correlated with nasalance(%). Conclusion : These findings might signify resonant phonation was not correlated with nasalance.

  • PDF

Range Stabbing Technique for Continuous Queries on RFID Streaming Data) (RFID 스트리밍 데이타의 연속질의를 위한 영역 스태빙 기법)

  • Park, Jae-Kwan;Hong, Bong-Hee;Lee, Ki-Han
    • Journal of KIISE:Databases
    • /
    • v.36 no.2
    • /
    • pp.112-122
    • /
    • 2009
  • The EPCglobal leading the development in RFID standards proposed Event Cycle Specification (ECSpec) and Event Cycle Reports (ECReports) for the standard about RFID middleware interface. ECSpec is a specification for filtering and collecting RFID tag data and is treated as a Continuous Query (CQ) processed during fixed time intervals repeatedly. ECReport is a specification for describing the results after ECSpec is processed. Thus, it is efficient to apply Query Indexing technique designed for the continuous query processing. This query index processes ECSpecs as data and tag events as queries for efficiency. In logistics environment, the similar or same products are transferred together. Also, when RFID tags attached to the products are acquired, the acquisition events occur massively for the short period. For these properties, it is inefficient to process the massive events one by one. In this paper, we propose a technique reducing similar search process by considering tag events which are collected by the report period in ECSpec, as a range query. For this group processing, we suggest a queuing method for collecting tag events efficiently and a structure for generating range queries in the queues. The experiments show that performance is enhanced by the proposed methods.

Quantitative Label-free Terahertz Sensing of Transdermal Nicotine Delivered to Human Skin

  • Lee, Gyuseok;Namkung, Ho;Do, Youngwoong;Lee, Soonsung;Kang, Hyeona;Kim, Jin-Woo;Han, Haewook
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.368-372
    • /
    • 2020
  • We report the terahertz time-domain spectroscopy (THz-TDS) of transdermal drug delivery in human skin. The time evolution of transdermal nicotine delivery in nicotine patches was assessed by detecting the transmission coefficient of sub-picosecond THz pulses and using a semi-analytic model based on the single-layer effective medium approximation. Using commercial nicotine patches (Nicoderm CQ®, 7 mg/24 h), THz transmission coefficients were measured to quantitatively analyze the cumulative amounts of nicotine released from the patches in the absence of their detailed specifications, including multilayer structures and optical properties at THz frequencies. The results agreed well with measurements by conventional in vitro and in vivo methods, using a diffusion cell with high-performance liquid chromatography and blood sampling respectively. Our study revealed the ability of the THz-TDS method to be an effective alternative to existing methods for noninvasive and label-free assessments of transdermal drug delivery, showing its high promise for biomedical, pharmaceutical, and cosmetic applications.

An Experimental Study of Comfortable Pitch and Loudness with Target Matching: Effects on Electroglottographic and Acoustic Measures

  • Choi, Seong Hee
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.139-146
    • /
    • 2012
  • This study was designed to examine comfort levels of pitch and loudness with target matching and their effects on electroglottographic (EGG) and acoustic measures. Twelve speakers, six males and six females, were instructed to produce /a/ sustained vowel for three seconds at a comfortable pitch and loudness level without any instruction and with a target matching procedure of either a certain f0 or SPL separately with visual and auditory feedback. The range of pitch for females and males were presented by progressing up and down randomly at intervals of 5Hz from 150 Hz to 310 Hz (total 33 frequency targets) and from 85 Hz to 190 Hz (total 22 frequency targets), respectively. The loudness levels were 65, 75, 85, 95 dB (total of four intensity targets) for both males and females. Subjective estimations of comfortable levels were obtained using a 10-point equal-appearing interval rating scale following each phonation. The results showed that males and females demonstrated similar trends in loudness levels with greatest comfort at 75 dB, whereas pitch comfort ratings showed a greater variability with females having a wider range with target matching. In the comfort levels of individuals, most male and female speakers rated higher comfort at soft, rather than loud phonations. On the other hand, most male speakers perceived highest comfort levels below the comfort pitch levels they phonated under natural conditions. Higher frequency ranges, however, were perceived to be more comfortable than those of natural condition in most female speakers, although the comfortable pitch levels in spontaneous phonations were within the comfort level ranges determined by targeted phonations. When comparing acoustic (%jitter, %shimmer, SNR) and EGG measures (CQ%) between spontaneous comfortable phonations and targeted phonations produced by the same subject at similar f0 and intensity, no significant differences were observed (p>0.05). Thus, target matching procedures may be considered a compatible and alternative method to reduce the variability of comfortable pitch and loudness levels by eliciting consistent comfortable phonations.

A STUDY ON THE MECHANICAL PROPERTIES OF EXPERIMENTAL, COMPOSITES CONTAINING ZIRCONIA FILLER (지르코니아 필러를 첨가한 복합레진의 기계적 성질에 관한 연구)

  • Rew, Kyung-Hee;Choi, Ho-Young;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.421-434
    • /
    • 2000
  • The purpose of this study was to evaluate the influences of incorporation of zirconium-silicate on diametral tensile strength, shear bond strength to the enamel, and depth of cure of 7 experimental composites. One group contained no filler(group 1 or control group), and the other 6 composites contain 75% filler in which zirconium-silicate(Zr-Si) were 0%, 2%, 4%, 6%, 8%, 10% with reduced contents of silica filler, respectively. Both of fillers were treated with 1% silane (${\gamma}$-methacryloxypropyltrimethoxy silane). Light curable monomers were prepared by mixing Bis-GMA and TEGDMA with 3:1 ratio and adding camphoroquinone(CQ) 0.6% with tertiary amine 0.3%. Diametral tensile strengths of specimens with $3mm{\times}6mm$ were measured with Instron (No.4467, USA) with 1mm/min crosshead speed. Shear bond strengths of composites which bonded to bovine enamel etched with 37% phosphoric acid were measured at Instron Testing Machine with as same speed as in diametral tensile strengths. Depth of cure were measured by a method that composite was filled in cylinder mold, illuminated at one side. and uncured composite was removed with acetone, and the residual thickness of composite was measured. Following results were obtained ; 1. Composites containing 0%, 2%, or 4% zirconium-silicate filler(group 2, 3 and 4) showed the statistically higher diametral tensile strength than the others. (p<0.05) 2. Increase of zirconium-silicate filler contents reduced the diametral tensile strength of experimental composites. ($r^2$=0.8721, p=0.0002) 3. Increase of zirconium-silicate filler contents did not affect the shear bond strength of experimental composites. ($r^2$=0.2815, p=0.4067) 4. Increase of zirconium-silicate filler contents reduced significantly the depth of cure of experimental composites. ($r^2$=0.9700, p<0.0001) These results mean that the mechanical properties of composites could not be improved by incorporation of small amount of zirconium-silicate filler. Also, the increased contents of zirconium-silicates fillers was found to reduce the diametral tensile strength and depth of cure.

  • PDF

An Analysis of Middle school Technology Teachers' Stage of Concerns about Maker Education By Concerns-Based Adoption Model (관심기반수용모형(CBAM)에 의한 중학교 기술교사의 메이커 교육 관심도 분석)

  • Kang, Sang-Hyun;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.44 no.2
    • /
    • pp.104-122
    • /
    • 2019
  • In the era of the fourth industrial revolution, maker education is drawing attention as a method of student-led education. At a time when interest in maker education is also growing in technology education, figuring out what stage of concern(SoC) a middle school technology teacher is critical to effective implementation. This study analyzed SoC in maker education by layer sampling among 400 middle school technology teachers using Concerns-based adoption model. SoC was then obtained by measuring the origin using the SoCQ and then presenting it as a SOCQ profile. Gender, training experience with two lower variables were analyzed using t verification, working cities, teaching experience with more than three lower variables were analyzed using one-way ANOVA. Studies showed that SoC in maker education of middle school technology teachers showed the most similar characteristics to that of non-users. The difference in concern depending on gender was that male teachers were more concerned in maker education than female teachers. The difference in concern depending on the working city was that teachers working in the township were more concerned in the maker education than teachers working in the large city, and the difference in concern depending on the teaching career was higher among teachers with middle experience than those with low and high experience. There was also a higher stage of concern in maker education than in teachers without training experience. Therefore, it is necessary to provide middle school technology teachers with an introduction to the maker education and various information, teaching, learning and evaluation data to enhance overall concern and to support the use and evaluation of the maker education in the classroom by providing various teacher training and consulting on the maker education in the future. Further, through further study, we should conduct study that analyzes both Stage of Concern, Level of Use and Innovation Configuration, to put in the effort for effective settlement of maker education.

MICROLEAKAGE OF THE EXPERIMENTAL COMPOSITE RESIN WITH THREE COMPONENT PHOTOINITIATOR SYSTEMS (3종 광중합개시제를 함유한 실험용 복합레진의 미세누출도)

  • Kim, Ji-Hoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2009
  • This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 ${\mu}m$) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/$cm^2$. Teeth were thermocycled fivehundred times between $50^{\circ}C$and $550^{\circ}C$for 30s at each temperature. Electrical conductivity (${\mu}A$) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (${\mu}A$)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.