• Title/Summary/Keyword: CPR performance

Search Result 188, Processing Time 0.019 seconds

Effects of Case-based Small Group Learning on Daycare Center Teachers' Coping Ability in Emergency Situations: Focus on Daily Life and Cardiopulmonary Resuscitation (보육교사를 위한 응급상황 대처 사례기반 소그룹 학습의 효과: 일상생활 응급상황과 심폐소생술 중심으로)

  • Choi, Eun-Ju
    • Child Health Nursing Research
    • /
    • v.19 no.3
    • /
    • pp.168-176
    • /
    • 2013
  • Purpose: This study was conducted to examine the effects of case-based learning on the coping ability of daycare center teachers in emergency situations. In the study knowledge of emergency treatment methods, attitude, intention and ability to perform CPR between were examined in an experimental group (daycare center teachers who participated in the small groups discussing case studies and comparing them with their own experience) and a control group. Methods: The study was designed using a nonequivalent control group pretest-posttest design. Sixty-four teachers were recruited from 40 child daycare centers in S city located in J province. Thirty-three teachers were assigned to experimental group and participated in the case-based small group learning. The data were analyzed using the SPSS 18.0 program to perform ${\chi}^2$-test, Pearson correlation coefficients and t-test. Results: The experimental group showed significantly higher posttest scores in knowledge, attitude, intention, and performance ability than those of the control group. Conclusion: The study results indicate that case-based small group learning on coping ability in emergency situation is effective in increasing knowledge, attitude, intention, and performance ability for daycare center teachers.

The Work and Job Satisfaction of Paramedics in the Emergency Room of University Hospitals (대학병원 응급실 내 1급 응급구조사의 업무와 직무만족도)

  • Lee, Ok-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.1
    • /
    • pp.47-63
    • /
    • 2011
  • Purpose : This research is to examine the work and job satisfaction of paramedics in the emergency room of university hospitals. This research is done to provide basic data needed for establishing work realms of paramedics in hospitals and to enhance their degree of satisfaction. Methods : Research questionnaire survey was conducted on 141 paramedics working in the emergency room of 32 university hospitals from August 24, 2010 to September 30, 2010 through direct visits and telephone interviews or email to explain the purpose of this research and assurance of confidentiality of responses on the questionnaires. As the tool for the degree of job satisfaction, 'The Index of Work Satisfaction' developed by Slavitt, et al(1978) and revised and supplemented by Soon-shim Kim and Hye-ran Kwon(2002) was used. The collected data were analyzed by evaluating frequency, percentage, mean, standard deviation, t-test and ANOVA, Cronbach's $\alpha$ by using SPSS WIN 18.0 program. Results : 1. Investigating the work and role of paramedics in the emergency room of university hospitals, electrocardiogram(EKG) was found to be highest with $\alpha$ was widely used with the rate of patient evaluation and test area. In the medical treatment for patients area, cardiopulmonary resuscitation(CPR) with 95%(134 persons) and ventilation assistance through ambu bagging(BVM) with 95%(134 persons) were found to be high. $\alpha$ were performed. In the role within the hospital and other areas, a member of CPR team in the hospital accounted for 78%(110 persons). 2. In the measurements of the job satisfaction of paramedics working at university hospitals, the total mean score was 2.91. The mean score in each question area indicated: section on job 3.48, autonomy 3.05, interaction 3.01, organizational demand 2.85, working conditions 2.67, salaries 2.40. This result obviously demonstrates the work of paramedics itself was most satisfied but the salaries were most dissatisfied. 3. In the measurements of the job satisfaction of paramedics working at university hospitals, job satisfaction based on the general characteristics showed significant difference in age (F=6.547, p=.002), gender (F=4.436, p=.000) marital status (F=-3.270, p= .001), religion (F=2.041, p= .043), motive for application (F=3.603, p= .015), and salary (F=6.658, p= .000). 대학병원 응급실 내 1급 응급구조사의 업무와 직무만족도 The Journal of the Korean Society of Emergency Medical Technology Vol. 15 (1) 63 4. In the measurements of the job satisfaction of paramedics working at university hospitals, job satisfaction based on the working environmental characteristics showed significant difference in total number of paramedics (F=3.779, p= .012), form of employment (F=5.601, p= .001), existence or non-existence of intention to change jobs (F=-4.037, p= .000). Conclusion : The work of paramedics in the emergency room of university hospitals consists of lots of treatment processes after specialized diagnosis and performance of professionally subdivided works. However, current legislation does not reflect such circumstances to which paramedics are exposed; thus, it should be considered for further revision and modification. The degree of job satisfaction of paramedics in the emergency room of university hospitals was high but low in salaries and working conditions were the weak points. The measures to enhance their degree of job satisfaction should be taken though improvement of labor conditions such as consideration of the rate of increase in salaries, compensation for overtime work, providing rest areas, improvement of current employment system, and conversion of temporary employees into regular employees.

Preference and Performance Fidelity of Modified Korean Physician Order for Life-Sustaining Treatment (MK-POLST) Items in Hospice Patients with Cancer (수정된 한글 연명의료계획서(Modified Korean Physician Order for Life-Sustaining Treatment, MK-POLST) 분석을 통한 호스피스 병동 환자의 의료 중재 항목별 선호도 및 충실도 조사)

  • Han, Ji Hee;Chun, Hye Sook;Kim, Tae Hee;Kim, Rock Bum;Kim, Jung Hoon;Kang, Jung Hun
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.4
    • /
    • pp.198-206
    • /
    • 2019
  • Purpose: The Act on Hospice and Palliative Care and Decisions on Life-sustaining Treatment for Patients at the End of Life was enacted in 2016 and has taken effect since 2018 February. The content of this act was based on Physician Orders for Life-Sustaining Treatment (POLST) in the United States and we modified it for terminal cancer patients registering hospice. The object of this study is to investigate preference and implementation rate for modified Korean POLST (MMK-POLST) items in hospice ward. Methods: From February 1, 2017 to April 30, 2019, medical records regarding MMK-POLST were retrospectively analyzed for all patients hospitalized in the hospice ward of Gyeongsang National University Hospital. Results: Of the eligible 387 total cohorts, 295 patients filled out MK-POLST. MK-POLST has been completed in 133 cases (44.1%) by the patient themselves, 84 cases (28.5%) by the spouse, and 75 cases (25.4%) by their children, respectively. While only 13 (4.4%) out of 295 MK-POLST completed patients refused the parenteral nutrition and 5 patients (1.7%) for palliative sedation, the absolute majority of 288 (97.6%) patients did not want cardiopulmonary resuscitation (CPR) and ventilators and 226 people (76.9%) for pressor medications. Kappa values for the matched strength of MK-POLST implementation were poor for all items except CPR, ventilators and palliative sedation. Conclusion: Hospice patients refused to conduct cardiopulmonary resuscitation, ventilators and pressor agents. In contrast, antibiotics, parenteral nutrition and palliative sedation were favored in the majority of patients.

Task Analysis of Paramedics of Korea Based on DACUM Method (DACUM 기법에 의한 1급 응급구조사의 직무분석)

  • Bae, Ki-Sook;Koh, Bong-Yeun;Lee, Jung-Eun;Lee, In-Mo;Choi, Keun-Myoung;Kim, Soo-Tae
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.1
    • /
    • pp.5-23
    • /
    • 2011
  • Objective : This study grasps specific task on paramedics who plays a great role in the emergency scene, thereby eliciting definition of job called paramedics and analyzing occupation by DACUM method. Thus, the aim is to suggest working-level guidelines on the task of paramedics. Methods : It targeted paramedics who are working at hospitals, fire stations, and industries in Seoul and Gyeonggi area from Oct. 11, 2010 to Nov. 30. A total of 608 copies of questionnaire were analyzed by DACUM method. A research tool on occupational analysis consisted of 8 pieces for duty, 43 pieces for task, and 149 pieces for task elements. In order to survey performance frequency, importance, and difficulty by element, each task was developed by this research team, and each task was analyzed and finally elicited through workshop of DACUM method. Results : The occupational definition of paramedics, which was defined through this DACUM, was elicited as 'professional job of performing emergency medical care on the scene, during transferring, or within medical institution in order to maintain life and prevent wound deterioration, targeting a person who is put in emergency situation.' Task element, whose performance frequency was indicated to be the highest, was in order of checking mental status($2.76{\pm}0.497$), checking vital signs($2.70{\pm}0.578$), and airway/c-spine immobilization($2.69{\pm}.546$). Especially, defibrillation stood at $2.23{\pm}.655$ points. Task element, whose performance frequency was low, was in order of caring sexual abuse victims($1.32{\pm}0.563$), performing cricothyrotomy($1.36{\pm}0.618$), and caring cardiac arrest victims($1.40{\pm}0.636$). Importance of task was in order of airway/c-spine immobilization ($2.88{\pm}0.338$), maintenance of respiration($2.88{\pm}0.351$), caring cardiac arrest victims($2.87{\pm}0.349$), and performing CPR($2.87{\pm}0.361$). Task element, whose importance is low, was indicated to be in order of enema($2.29{\pm}0.736$), urinary catheterization($2.35{\pm}0.664$), and nasogastric intubation($2.35{\pm}0.667$). Task element, whose difficulty was shown to be the highest, was indicated to be in order of caring cardiac arrest victims during pregnancy ($2.60{\pm}0.559$), caring cardiovascular injury($2.59{\pm}0.546$), and labor management($2.53{\pm}0.533$). Conclusion : Based on the results of this study, the job performance work table(Dacom chart) of paramedics is suggested to be used, thereby being applied to development in education and curriculum of paramedics. It is necessary to evaluate usefulness of the job performance work table by estimating effect of education for paramedics based on the job performance work table of paramedics.

Flexible InGaP/GaAs Double-Junction Solar Cells Transferred onto Thin Metal Film (InGaP/GaAs 이중접합 기반의 고효율 플렉시블 태양전지 제조기술 연구)

  • Moon, Seungpil;Kim, Youngjo;Kim, Kangho;Kim, Chang Zoo;Jung, Sang Hyun;Shin, Hyun-Beom;Park, Kyung Ho;Park, Won-Kyu;Ahn, Yeon-Shik;Kang, Ho Kwan
    • Current Photovoltaic Research
    • /
    • v.4 no.3
    • /
    • pp.108-113
    • /
    • 2016
  • III-V compound semiconductor based thin film solar cells promise relatively higher power conversion efficiencies and better device reliability. In general, the thin film III-V solar cells are fabricated by an epitaxial lift-off process, which requires an $Al_xGa_{1-x}As$ ($x{\geq}0.8$) sacrificial layer and an inverted solar cell structure. However, the device performance of the inversely grown solar cell could be degraded due to the different internal diffusion conditions. In this study, InGaP/GaAs double-junction solar cells are inversely grown by MOCVD on GaAs (100) substrates. The thickness of the GaAs base layer is reduced to minimize the thermal budget during the growth. A wide band gap p-AlGaAs/n-InGaP tunnel junction structure is employed to connect the two subcells with minimal electrical loss. The solar cell structures are transferred on to thin metal films formed by Au electroplating. An AlAs layer with a thickness of 20 nm is used as a sacrificial layer, which is removed by a HF:Acetone (1:1) solution during the epitaxial lift-off process. As a result, the flexible InGaP/GaAs solar cell was fabricated successfully with an efficiency of 27.79% under AM1.5G illumination. The efficiency was kept at almost the same value after bending tests of 1,000 cycles with a radius of curvature of 10 mm.

A Comparative Study on Defibrillation Efficiency According to Defibrillation Type (제세동 유형에 따른 제세동 효율성 비교 연구)

  • Lee, Hyeon-Ji;Hwang, Jeong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.579-588
    • /
    • 2017
  • The purpose of this study was to examine the defibrillation efficiency according to the defibrillator type among paramedics by making a comparative analysis of the chest compression pause time and defibrillation efficiency after providing simulation education. The subjects in this study were 15 paramedics who were selected from a provincial 119 safety center. The experiment was conducted using a single-group pretest-post test design from March 2 to August 31, 2016. The collected data were analyzed by SPSS WIN 21.0, and a frequency analysis was conducted. The findings of this study were as follows: First, there was a significantly greater decrease in the chest compression pause time during CPR after providing simulation education when semi-automated defibrillators were used than when manual paddles and manual pads were employed. Second, there was a statistically significant decrease in the performance time of defibrillation when semi-automated defibrillators were used than when manual paddles and manual pads were used. The findings of this study are expected to provide paramedics with simulation education on how to promptly read ECGs using the manual mode of a semi-automated defibrillator to help more patients revive and on how to facilitate their job enlargement.

Fabrication of wide-bandgap β-Cu(In,Ga)3Se5 thin films and their application to solar cells

  • Kim, Ji Hye;Shin, Young Min;Kim, Seung Tae;Kwon, HyukSang;Ahn, Byung Tae
    • Current Photovoltaic Research
    • /
    • v.1 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • $Cu(In,Ga)_3Se_5$ is a candidate material for the top cell of $Cu(In,Ga)Se_2$ tandem cells. This phase is often found at the surface of the $Cu(In,Ga)Se_2$ film during $Cu(In,Ga)Se_2$ cell fabrication, and plays a positive role in $Cu(In,Ga)Se_2$ cell performance. However, the exact properties of the $Cu(In,Ga)_3Se_5$ film have not been extensively studied yet. In this work, $Cu(In,Ga)_3Se_5$ films were fabricated on Mo-coated soda-lime glass substrates by a three-stage co-evaporation process. The Cu content in the film was controlled by varying the deposition time of each stage. X-ray diffraction and Raman spectroscopy analyses showed that, even though the stoichiometric Cu/(In+Ga) ratio is 0.25, $Cu(In,Ga)_3Se_5$ is easily formed in a wide range of Cu content as long as the Cu/(In+Ga) ratio is held below 0.5. The optical band gap of $Cu_{0.3}(In_{0.65}Ga_{0.35})_3Se_5$ composition was found to be 1.35eV. As the Cu/(In+Ga) ratio was decreased further below 0.5, the grain size became smaller and the band gap increased. Unlike the $Cu(In,Ga)Se_2$ solar cell, an external supply of Na with $Na_2S$ deposition further increased the cell efficiency of the $Cu(In,Ga)_3Se_5$ solar cell, indicating that more Na is necessary, in addition to the Na supply from the soda lime glass, to suppress deep level defects in the $Cu(In,Ga)_3Se_5$ film. The cell efficiency of $CdS/Cu(In,Ga)_3Se_5$ was improved from 8.8 to 11.2% by incorporating Na with $Na_2S$ deposition on the CIGS film. The fill factor was significantly improved by the Na incorporation, due to a decrease of deep-level defects.

A Review on TOPCon Solar Cell Technology

  • Yousuf, Hasnain;Khokhar, Muhammad Quddamah;Chowdhury, Sanchari;Pham, Duy Phong;Kim, Youngkuk;Ju, Minkyu;Cho, Younghyun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.9 no.3
    • /
    • pp.75-83
    • /
    • 2021
  • The tunnel oxide passivated contact (TOPCon) structure got more consideration for development of high performance solar cells by the introduction of a tunnel oxide layer between the substrate and poly-Si is best for attaining interface passivation. The quality of passivation of the tunnel oxide layer clearly depends on the bond of SiO in the tunnel oxide layer, which is affected by the subsequent annealing and the tunnel oxide layer was formed in the suboxide region (SiO, Si2O, Si2O3) at the interface with the substrate. In the suboxide region, an oxygen-rich bond is formed as a result of subsequent annealing that also improves the quality of passivation. To control the surface morphology, annealing profile, and acceleration rate, an oxide tunnel junction structure with a passivation characteristic of 700 mV or more (Voc) on a p-type wafer could achieved. The quality of passivation of samples subjected to RTP annealing at temperatures above 900℃ declined rapidly. To improve the quality of passivation of the tunnel oxide layer, the physical properties and thermal stability of the thin layer must be considered. TOPCon silicon solar cell has a boron diffused front emitter, a tunnel-SiOx/n+-poly-Si/SiNx:H structure at the rear side, and screen-printed electrodes on both sides. The saturation currents Jo of this structure on polished surface is 1.3 fA/cm2 and for textured silicon surfaces is 3.7 fA/cm2 before printing the silver contacts. After printing the Ag contacts, the Jo of this structure increases to 50.7 fA/cm2 on textured silicon surfaces, which is still manageably less for metal contacts. This structure was applied to TOPCon solar cells, resulting in a median efficiency of 23.91%, and a highest efficiency of 24.58%, independently. The conversion efficiency of interdigitated back-contact solar cells has reached up to 26% by enhancing the optoelectrical properties for both-sides-contacted of the cells.