• Title/Summary/Keyword: CPM(Continuous passive motion)

Search Result 24, Processing Time 0.022 seconds

Analysis of Range-of-Motion in Continuous Passive Motion Rehabilitation (무릎관절 재활 운동기기의 운동범위 분석)

  • Park, Won-Man;Kim, Yoon-Hyuk
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1515-1517
    • /
    • 2008
  • The purposes of this study were to measure the ranges of motion in knee joint and during continuous passive motion(CPM) treatment and to computationally calculate joint angles at the knee joint dependent on the CPM machine design and its application. Four CPM machines and eleven candidates were recruited for this study. Experimental and numerical studies have been peformed to calculate the range-of-motion of CPM machines. From the experimental measurements, the average range of motions at the knee joint for the CPM machine #1, #2, #3, and #4 were lower than the manufactures suggested values due to improper alignments of the hip and knee joints to the CPM machines. Different design of CPM machine generated different outcomes of the ROM at the knee joints during CPM. The experiments and kinematic simulation in this study could be used to provide useful guidance in the treatment of CPM after joint surgery.

  • PDF

A Systemic Review of Korean Medical Treatment Combined with Continuous Passive Motion Therapy on the Knee Joint Postoperative Rehabilitation (슬관절 수술 후 재활에 대한 Continuous Passive Motion 치료와 한의 병행치료의 체계적 문헌 고찰)

  • Ha, Hyun Ju;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.3
    • /
    • pp.33-45
    • /
    • 2017
  • Objectives The objective of this study is to report the evidence that continuous passive motion (CPM) therapy combined with Korean Medicine is effective for knee injuries. Methods We searched 2 Korean medical electronic databases, and 2 Chinese electronic databases to find randomized controlled clinical trials (RCTs) that treat knee injuries with Korean Medicine combined with CPM therapy. We selected studies by screening. We extracted data from selected RCTs, and analyzed RCTs by using Cochrane's Risk of bias criteria. Results 386 studies are searched, and 7 RCTs are selected. According to the study, several kinds of Korean Medicine such as hydrotherapy, decoction, acupuncture, moxibustion, and manual therapy are used with CPM therapy for the knee joint postoperative rehabilitation. We found the encouraging evidence that Korean Medicine and CPM combined therapy is more effective than single CPM therapy by alleviating pain, increasing range of motion, and improving knee function, etc. However, the risk of bias in most RCTs was judged to be uncertain. Conclusions Combination of Korean Medicine and CPM therapy can compensate the defect of single CPM therapy, and promotes the recovery of knee joint function.

The Effects of CPM (Continuous Passive Motion) on Hand Function and Muscular Strength for Patients with Stroke (CPM (Continuous Passive Motion) 사용이 뇌졸중 환자의 손 기능과 근력향상에 미치는 영향)

  • Jeong, In-Seon
    • Therapeutic Science for Rehabilitation
    • /
    • v.3 no.2
    • /
    • pp.71-81
    • /
    • 2014
  • Objective: The purpose of this study is to ob serve effects of CPM(Continuous Passive Motion) on hand functional and upper-extremity muscular strength rehabilitation for stroke patients. Method: Objects of this study, three patients have the symptoms of hemiplegia due to stroke. These are acute patients, within a 18 months after treatment and correspond in Brunnstrom stage 4~6. This study used single subject (A-B) design for three patients with a stroke and the effect of CPM was measured using Jebsen-Taylor hand function test, Purdue Pegboard test, hand muscular strength test. They received CPM for 3 weeks, 2 per day, 30 minutes for each, total 30 times. Results: Two patients' results of fingertip grip test in hand strength measurements did not change. Results of Jebsen-Taylor hand function test, Purdue Pegboard test and other hand muscular strength test were improved. To validate statistical results nonparametric statistical method, Wilcoxon signed ranks test was performed. P-Values are greater than 0.05 so difference between be fore and after treatment is not statistically significant result. Conclusion: Despite of limitation of short program period and fewer participants, CPM which has been conducted for stroke patients showed the effect on improvement of hand function and muscle strength. This study shows that CPM which is mainly used to treate lower-extremity rehabilitation can be use to improve performance of hand function and strength for patients with stroke.

The Effect of Continuous Passive Motion and Continuous Active Motion on Joint Proprioception After Total Knee Replacement (슬관절전치환술 후 연속수동운동(CPM)과 연속능동운동(CAM) 적용이 관절 고유수용감각에 미치는 영향)

  • Yang, Jin-Mo;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.1_2
    • /
    • pp.41-52
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the effects of continuous passive motion(CPM) and continuous active motion(CAM) on proprioception of the knee after total knee replacement(TKR). Methods: Twenty patients with TKR were randomly allocated into two groups, the CPM group(n=10) and the CAM group(n=10). All subjects were evaluated for levels of pain, passive range of motion and angle reproduction of the knee. An angle reproduction test was used to assess the proprioceptive deficit. Two types of angle reproduction test were used: a passive angle reproduction(PAR) test and an active angle reproduction(AAR) test. The relevant examinations were performed before and after intervention(on the 5th day and the 10th day). The statistical significance were calculated using a t-test and a one-way repeated ANOVA. Results: A pre-intervention significant difference was not found between the two groups. Significantly better results were before and after the intervention at 10 days, for the PAR(flexion direction) test; however, only in the CAM group. There were no significant difference, either before or after the intervention, for the AAR test(flexion and extension direction) in both group. Both groups experienced similar levels of pain and passive range of knee motion before and after the intervention. Conclusion: This study revealed that CAM was a better effect to restore position sense of the knee joint after TKR.

  • PDF

Design of Multifunctional Compound Joint Medical Equipment for Continuous Passive Motion (다기능 복합관절 연속수동운동 의료기기 설계)

  • Lee, Kang Won;Yang, Oh;Lee, Chang Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.126-131
    • /
    • 2022
  • The number of joint disease patients is increasing every year. Currently, the most CPM(Continuous Passive Motion) equipment uses expensive imported equipment, and one CPM equipment is designed to be used only in one joint, medical personnel or hospitals who are the main users of the medical equipment need to have several types of CPMs for joint rehabilitation. To solve this problem, this paper designed a multifunctional joint medical equipment that enables rehabilitation of knee, shoulder, and elbow joints in one CPM equipment and includes general, intensive, and adaptive exercise functions for effective treatment according to the patient's condition. The patient's condition was diagnosed using a load cell and a current sensor. In this paper, effective rehabilitation methods were presented and high reliability and precision of medical equipment was confirmed through experiments using potentiometer, encoder, and PI controller.

Design of Continuous Passive Motion Medical Device System with Range of Motion Measurement Function (관절가동범위 측정 기능을 갖는 연속수동운동 의료기기 시스템 설계)

  • Kang Won Lee;Min Soo Park;Do Woo Yu;Oh Yang;Chang Ho Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.87-92
    • /
    • 2023
  • As the elderly population increases, the number of patients with various joint diseases, including degenerative arthritis, is steadily increasing. CPM medical devices are needed to effectively treat degenerative arthritis that is common in the elderly population. Domestic CPM medical devices have limited functions and are highly dependent on imports for expensive imported medical devices. To solve this problem, we designed a ROM measurement function using a current sensor that is not present in existing composite joint CPM medical devices. The algorithm was designed using the fact that the force caused by joint stiffness greatly increases the current flowing through the DC motor. In addition, the need for digital healthcare in the medical field is gradually expanding as the proportion of chronically ill patients increases due to the spread of the non-face-to-face economy due to COVID-19 and the aging population. Therefore, this paper aims to improve the performance of CPM medical devices by allowing real-time confirmation of rehabilitation exercise information and operation range measurement results in accordance with digital healthcare trends through a Bluetooth application developed as an Android studio.

  • PDF

The Clinical Case Report about Postoperative Rehabilitation for the Tear of Anterior Cruciate Ligament Treated with Korean Medical Treatment and Continuous Passive Motion (한방 치료와 연속 수동 운동(CPM)을 병행한 전방 십자인대 파열 환자의 수술 후 재활 치료에 대한 증례 보고)

  • Park, Chang-Hyun;Song, Yun-Kyung
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.11 no.1
    • /
    • pp.97-107
    • /
    • 2016
  • Objectives : The objective of this study is to report the effect of Koran medical treatment and CPM exercise on recovery after reconstruction surgery of torn anterior cruciate ligament Methods : A 27-year-old male patient who had anterior cruciate ligament reconstruction surgery was treated by Korean medical treatment and CPM exercise from March 24th 2015 to April 16th 2015. Results : After treatments, VAS were generally decreased, ROM of Lt. knee got better from $95^{\circ}/10^{\circ}$(flexion/extension) to $120^{\circ}/-5^{\circ}$ (flexion/extension), Lysholm Score increased from 26 to 63. Conclusions : This study showed that Korean medical treatments and CPM exercise has meaningful effect on recovery after reconstruction surgery of anterior cruciate ligament. And it is considered that we need to apporoach recovery of these kinds of operation with more active Korean medical treatment, and further researches should be done steadily.

  • PDF

Physical Therapy After Total Knee Replacement (A Comparison of Two Physical Therapy Techniques) (슬관절 전치환술 후의 물리치료)

  • Jang, Moon-Heon;Ko, Joo-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.4
    • /
    • pp.809-816
    • /
    • 1998
  • This study was conducted to evaluated the effects adding continuous passive motion(CPM) each day to the entire postoperative program of patients who received a total knee replacement(TKR). A retrospective chart review was completed for 31 patients(12 with bilateral involvement, totaling 44 knees)who received a TKR between 1996 and 1998. The data analysis compared the following variables for 28 patients who received CPM and 16 patients who received no CPM: the length of hospital stay(LOS), the frequency of postoperative complications, the number of post-operative days(PODs) range of motion (ROM). The CPM Group showed significant decreases in the frequency of complication(p<0.05), the LOS(p < 0.05), and No difference was demonstrated in the ROM of the two groups. We concluded that CPM was an effective adjunct to physical therapy care of patients undergoing total knee replacement.

  • PDF

The Clinical Results of Conservative Treatment of Frozen Shoulder Using Continuous Passive Motion

  • Chung, Hoe-Jeong;Kim, Doo-Sup;Yoon, Yeo-Seung;Lee, Dong-Woo;Hong, Kyung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.217-220
    • /
    • 2015
  • Background: The purpose of this study is to administer conservative treatment in 30 patients diagnosed with idiopathic frozen shoulder, following the suggested frozen shoulder rehabilitation program and to assess the clinical outcome using a prospective study. Methods: Thirty patients diagnosed with idiopathic frozen shoulder, treated with steroid hormone injection on the articular joint with an intra-articular steroid (triamcinolone 40 mg+lidocaine 4 ml) injection and started on stepwise shoulder extension exercise were chosen. The subjects were divided into two groups of 15 people each with one group undergoing rehabilitation with continuous passive motion (CPM) and the other group without it. Follow-ups were done before rehabilitation and at 4-week intervals with the 24th being the final week. At every follow-up, passive range of motion (ROM) was measured and surveys on pain and clinical score were administered. Results: In the last follow-up, both groups showed statistically significant improvements in all evaluation criteria. However, no statistical difference in all values of the ROM and Constant score evaluation criteria was observed between the groups. Only in the last follow-up, group 1 had a visual analog scale (VAS) score of $2.4{\pm}2.1$ points, which was lower, with statistical significance, than the VAS score of group 2, which was $4.4{\pm}3.1$ points (p<0.001). Conclusions: Study using CPM in treatment of frozen shoulder has been inadequate, meaning that there is still room for improvement and need for more study on setting a more specific protocol and guidelines for this procedure.

The Effects of Active Exercise Program using Sling on the Pain and Balance Following Total Knee Replacement (슬링을 이용한 능동 운동프로그램이 무릎 관절 전치환술 환자의 통증과 균형에 미치는 영향)

  • Ryu, Je-Ju;Jeong, Beom-Cheol;Yoo, Kyung-Tae
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.2
    • /
    • pp.174-183
    • /
    • 2022
  • This study was conducted to investigate the effect of the active exercise program using sling on the pain and balance of total knee replacement patients. Subjects were 20 patients who received total knee replacement and are hospitalized, 10 patients in each group were randomly assigned to a group (CPM group) that applied only CPM (Continuous passive motion) and a group (CSG) that combined CPM with a active exercise program using sling. CG was performed CPM 5 days a week, CSG performed CPM 2 days a week and a active exercise program using sling 3 days a week, and each intervention was performed for 40 minutes a day for a total of 4 weeks. Pain was evaluated using VAS (Visual analog scale), and balance was measured using BT4 (Balance training 4) to measure C90 area, trace length, and Sway average velocity with eyes open and closed. As a result, there was a significant decrease in pain in both groups, and there was also a significant difference in the amount of change between groups. In balance, all variables except C90 of CG showed significant changes after intervention, and there was a significant difference between C90 and Vel with eyes closed in the amount of change between groups. Therefore, we believe that CPM and active exercise program using sling are effective interventions to reduce pain and improve balance in total knee replacement patients.