• Title/Summary/Keyword: CPAP

Search Result 81, Processing Time 0.034 seconds

Effects of CP AP Therapy on Systemic Blood Pressure, Cardiac Rhythm and Catecholamines Concentration in Patients with Obstructive Sleep Apnea (폐쇄성 수면 무호흡에서 CPAP 치료가 전신성 혈압, 심조율 및 catecholamines 농도에 미치는 영향)

  • Kang, Ji-Ho;Lee, Sang-Haak;Choi, Young-Mee;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.715-723
    • /
    • 2000
  • Background : Obstructive sleep apnea syndrome (OSAS) affects systemic blood pressure and cardiac function. The development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac rhythm, suggests that recurrent hypoxia and arousals from sleep may increase a sympathetic nervous system activity. Continuous positive airway pressure (CPAP) therapy has been found to be an effective treatment of OSAS. However, only a few studies have investigated the cardiovascular and sympathetic effects of CPAP therapy. We evaluated influences of nasal CPAP therapy on the cardiovascular system and the sympathetic activity in patients with OSAS. Methods : Thirteen patients with OSAS underwent CPAP therapy and were monitored using polysomnography, blood pressure, heart rate, presence of arrhythmia and the concentration of plasma catecholamines, before and with CPAP therapy. Results: The apnea-hypopnea index (AHI) was significant1y decreased (p<0.01) and the lowest arterial oxygen saturation level was elevated significantly after applying CPAP (p<0.01). Systolic blood pressure tended to decrease after CPAP but without statistical significance. Heart rates during sleep were not significantly different after CPAP. However, the frequency and number of types of arrhythmia decreased and sinus bradytachyarrhythmia disappeared after CPAP. Although there was no significant difference in the level of plasma epinephrine concentration, plasma norepinephrine concentration significantly decreased after CPAP (p<0.05). Conclusion : CPAP therapy decreased the apnea-hypopnea index, hypoxic episodes and plasma norepinephrine concentration. In addition, it decreased the incidence of arrhythmia and tended to decrease the systemic blood pressure. These results indicate that CPAP may play an important role in the prevention of cardiovascular complications in patients with OSAS.

  • PDF

Comparison for the Optimal Pressure between Manual CPAP and APAP Titration with Obstructive Sleep Apnea Patients (한국인 폐쇄성 수면 무호흡 환자의 적정 양압을 위한 수동화 양압 측정법과 자동화 양압 측정법의 비교)

  • Kim, Dae Jin;Choi, Byoung Geol;Cho, Jae Wook;Mun, Sue Jean;Lee, Min Woo;Kim, Hyun-Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.191-197
    • /
    • 2019
  • Although auto-adjusting positive airway pressure (APAP) titration at home has several advantages over a CPAP titration in terms of convenience and time saving, there are still concerns as to whether it will show corresponding accuracy when compared to laboratory-based polysomnography (PSG) and CPAP titration. To obtain more evidence supporting home-based auto-titration, APAP titration was performed at home for patients who were presented with OSA on laboratory-based diagnostic PSG followed by CPAP titration. A total of 79 patients were included in the study. They all underwent split-night PSG with CPAP titration, and APAP titration for more than 7 days. The patients with successful titration at both situations were selected. The optimal pressure and apnea-hypopnea index (AHI) of CPAP and APAP titration were compared. The optimal pressure for CPAP and APAP titration were $7.0{\pm}1.8cmH_2O$ and $7.6{\pm}1.6cmH_2O$ (P<0.001), whereas the corresponding AHI were $1.3{\pm}1.5/h$ and $3.0{\pm}1.7/h$ (P<0.001). As a result, the achievement rates of optimal pressure for CPAP and APAP titration were 96.2% and 94.9% (r=-0.045, P=0.688), respectively. The results of this study did not differ with regard to the optimal pressure between CPAP and APAP titration. Overall, CPAP and APAP titrations should be chosen depending on a required situation.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

Post-operative Continuous Positive Airway Pressure (CPAP) Therapy in Velopharyngeal Insufficiency Patient (지속성 양압 치료법을 이용한 구개인두기능부전증의 치료)

  • Kim, Kyu Nam;Koh, Kyung Suck;Jung, Seung Eun;Ha, Seung Hee;Park, Mi Kyung
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.73-76
    • /
    • 2010
  • Purpose: There are several surgical methods for correcting a velopharyngeal insufficiency (VPI) but in some cases, it is not possible to achieve complete recovery of the velopharyngeal function. This paper introduces a new therapy for treating hypernasality without further surgery using continuous positive airway pressure (CPAP). Methods: CPAP therapy was applied to seven VPI patients for eight weeks from April of 2007 to September of 2009. All patients underwent palatoplasty for the cleft palate and six patients underwent palatal lengthening for VPI before CPAP therapy. A speech pathologist performed an auditory perceptual evaluation to evaluate the improvement in hypernasality after 8-week CPAP therapy. Results: Six patients showed an improvement in hypernasality after CPAP therapy according to the auditory perceptual evaluation. One patient with severe hypernasality responded to the early part of therapy but the hypernasality did not improve after therapy. Conclusion: CPAP therapy might be effective in reducing the hypernasality in patients with VPI by providing resistance training to strengthen the velopharyngeal closure muscles. In particular, CPAP therapy could be more effective for patients who show mild to moderate hypernasality after surgery.

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

A Study on the Effects of the Early Use of Nasal CPAP in the Weaning of Mechanical Ventilators (인공호흡기 이탈시 비강내 CPAP 조기 사용 효과에 관한 연구)

  • Kim, Yeoung Ju;Jung, Byun Kyung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1200-1206
    • /
    • 2003
  • Purpose : This study was conducted for the use of nasal continuous positive airway pressure (CPAP), by comparing the early use of non-invasive nasal CPAP with low intermittent mandatory ventilation(low IMV) and endotracheal CPAP in weaning a mechanical ventilator from infants with moderate respiratory distress syndrome(RDS). Methods : Thirty infants in the study group, with moderate RDS from November 2001 to June 2002, were administered surfactants and treated with the mechanical ventilator, and applied the nasal CPAP in weaning. Thirty infants of the control group, from January 1999 to September 2001, were applied low IMV and endoctracheal CPAP in weaning. Results : There were no significant differences in the characteristics, the severity of clinical symptoms, the initial laboratory findings and settings of the mechanical ventilator. After weaning, the study group showed no significant changes in $PaCO_2$. However, the control group showed a slight $CO_2$ retension after one and 12 hours. Twenty eight infants(93.3%) of the study group and 24 infants(80%) of the control group were successfully extubated. The primary cause of failure was apnea. There were no significant differences in the duration of weaning and the mechanical ventilator treatment between the groups. Complications in weaning were related to the fixation of nasal CPAP and the mechanical problems caused by endotracheal tube. Conclusion : Aggressive weaning is possible for moderate RDS, in which the nasal CPAP was used without the low IMV and the endotracheal CPAP process. It had no difficulties. In conclusion, the nasal CPAP is an adequate weaning method for moderate RDS.

Bayesian Network Model to Evaluate the Effectiveness of Continuous Positive Airway Pressure Treatment of Sleep Apnea

  • Ryynanen, Olli-Pekka;Leppanen, Timo;Kekolahti, Pekka;Mervaala, Esa;Toyras, Juha
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.346-358
    • /
    • 2018
  • Objectives: The association between obstructive sleep apnea (OSA) and mortality or serious cardiovascular events over a long period of time is not clearly understood. The aim of this observational study was to estimate the clinical effectiveness of continuous positive airway pressure (CPAP) treatment on an outcome variable combining mortality, acute myocardial infarction (AMI), and cerebrovascular insult (CVI) during a follow-up period of 15.5 years ($186{\pm}58$ months). Methods: The data set consisted of 978 patients with an apnea-hypopnea index (AHI) ${\geq}5.0$. One-third had used CPAP treatment. For the first time, a data-driven causal Bayesian network (DDBN) and a hypothesis-driven causal Bayesian network (HDBN) were used to investigate the effectiveness of CPAP. Results: In the DDBN, coronary heart disease (CHD), congestive heart failure (CHF), and diuretic use were directly associated with the outcome variable. Sleep apnea parameters and CPAP treatment had no direct association with the outcome variable. In the HDBN, CPAP treatment showed an average improvement of 5.3 percentage points in the outcome. The greatest improvement was seen in patients aged ${\leq}55$ years. The effect of CPAP treatment was weaker in older patients (>55 years) and in patients with CHD. In CHF patients, CPAP treatment was associated with an increased risk of mortality, AMI, or CVI. Conclusions: The effectiveness of CPAP is modest in younger patients. Long-term effectiveness is limited in older patients and in patients with heart disease (CHD or CHF).

Effect of Optimal Humidification for Extremely Low Birth Weight Infants During Nasal Continuous Positive Airway Pressure (인공호흡기 가습기 적용방법이 초극소 저출생 체중아의 경비지속 기도 양압 환기법 유지기간에 미치는 영향)

  • Kim, Jung-Sook;Lee, Eun-Jung
    • Child Health Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • Purpose: To evaluate the efficacy of Optimal humidification during Nasal Continuous Positive Airway Pressure (nCPAP) for Extremely Low Birth Weight Infant (ELBWI). Methods: The study design was a pre-test-post-test nonequivalent nonsynchronized quasi-experimental design. The participants were 218 ELBWI on nCPAP (experimental group: 102 and control group: 116). Data collection was conducted from January 2005 to April 2010. In order to measure and analyze the nCPAP duration, reintubation and nasal condition, Chi-square test and t-test were used. Results: Hypothesis 1, that the duration with nCPAP in the experimental group is longer than that of the control group and hypothesis 2-3, that the rate of reintubation and nasal problems in the experimental group are lower than the control group, were all supported as there were statistically significant differences between two groups. Conclusion: The findings suggest that the Optimal humidification in this study is an efficient intervention because it helps increase the last time of nCPAP with ELBWI and minimize complications. It is expected that Optimal humidification is beneficial and helpful in preventing and caring for respiratory problems in these infants.

Prediction of Continuous Positive Airway Pressure Level for Treatment of Obstructive Sleep Apnea (폐쇄성 무호흡의 치료시 지속적 기도 양압치의 예측)

  • Lee, Kwan Ho;Chung, Jin Hong;Lee, Hyun Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.755-762
    • /
    • 1996
  • Background : Continuous positive airway pressure(CPAP) is doubtlessly using as a medical treatment of choice for patients with obstructive sleep apnea (OSA) syndrome. CPAP is effective in OSA patients as a physical "pneumatic pressure splint" mechanism. We have done this study for two purposes, first to seek for the factors to determine the optimal CPAP titer, second to predict the minimal CPAP titer using the determined factors. Methods: We studied a 72 OSA patients who were treated with CPAP. All of them were studied by using a two nights polysomnographic rests in hospital. We compared the patients requiring CPAP over $10cmH_2O$ with those who required CPAP under 5cm $H_2O$ to determine the factors affecting the minimal CPAP titer. Results : The high CPAP group is characterized by a significantly higher body mass index(BMI), apnea index(AI) and apnea and hyponea index(AHI) and significantly lower lowest $SaO_2$. Regression analysis using the optimal four variables resulted in the following prediction equation for CPAP titer. CPAPtiter=8.382 + 0.064 ${\times}$ BMI + 0.077 ${\times}$ AI - 0.004 ${\times}$ AHI - 0.077 ${\times}$ lowest $SaO_2$ When this regression equation was applied to the 72 patients, the mean CPAP titer as predicted by the above equation was $7.80{\pm}2.96$ mmHg. Compared this value with actually determined CPAPtiter, $7.93{\pm}4.00$mmHg, there was no significant difference between the two values. Conclusion: Obesity, apnea severity and lowest Sa02 were strongly correlated with CPAP titer. Linear regression equation for CPAP titer using these indices predicted very closely the actually measured values in the sleep laboratory.

  • PDF

Sleep Fragementation Decreases during the nCPAP Titration Night in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 압력 처방 검사 시 나타나는 수면분절의 감소)

  • Lee, Jin-Seong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Objectives: Obstructive sleep apnea syndrome (OSAS) not only causes respiratory disturbances during sleep but also decreases the quality of nocturnal sleep through sleep fragmentation and sleep structure change. We aimed at comparing the changes in sleep fragmentation and structure between baseline (diagnostic) nocturnal polysomnography (NPSG) and nCPAP (nasal continuous positive airway pressure) titration trial. Methods: One hundred and three patients with a baseline night of respiratory disturbance index (RDI) of 5 or greater and reduced RDI score during nCPAP titration night were retrospectively selected for the study. Sleep fragementation and sleep structure between baseline NPSG and the NPSG during nCPAP titration were compared. Sleep fragmentation index (SFI) was defined as the total number of awakenings and shifts to stage 1 sleep divided by the total sleep time in hour. SFI and other polysomnographic parameters were statistically compared between the two nights. Results: SFI during baseline NPSG and nCPAP titration nights were $29.0{\pm}13.8$ and $15.2{\pm}8.8$, respectively, indicating a significant SFI decrease during nCPAP titration (t=9.7, p<0.01). SFI showed significant negative correlations with sleep efficiency (r=-0.60, p<0.01) and total sleep time (r=-0.45, p<0.01) and a positive correlation with RDI (r=0.28, p<0.01). Conclusion: Use of nCPAP, even during the titration, significantly decreases sleep fragmentation and improves sleep structure in OSAS patients. We suggest that SFI may be utilized as a measure of assessing OSAS severity and nCPAP efficacy.

  • PDF