• Title/Summary/Keyword: CORRECTION

Search Result 9,605, Processing Time 0.039 seconds

Algorithm and Hardware Implementation of Redeye Correction Using the Redeye Features (적목현상 특징을 이용한 적목현상 보정 알고리즘 및 하드웨어 구현)

  • Lee, Song-Jin;Jang, Won-Woo;Choi, Won-Tae;Kim, Suk-Chan;Kang, Bong-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 2009
  • In this paper, we proposed an algorithm of redeye correction. For naturally redeye correction, we assumed positions of the redeye at an image which produced redeye, and we estimated rate of the redeye to apply the appropriate redeye correction suitably. We extract and label pixels those are possible of generating redeye using red, skin and reflected light color. The each labeled group is decided by rates of length and width, dimension, density, the color of white of the eye and reflected light color of groups for the redeye group. We corrected positions of redeye using blurring effect, naturally. In the case of designing the proposed algorithm, we designed the redeye correction hardware using the minimum of memories for efficiency of hardware.

  • PDF

Packet-Level Scheduling for Implant Communications Using Forward Error Correction in an Erasure Correction Mode for Reliable U-Healthcare Service

  • Lee, Ki-Dong;Kim, Sang-G.;Yi, Byung-K.
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.160-166
    • /
    • 2011
  • In u-healthcare services based on wireless body sensor networks, reliable connection is very important as many types of information, including vital signals, are transmitted through the networks. The transmit power requirements are very stringent in the case of in-body networks for implant communication. Furthermore, the wireless link in an in-body environment has a high degree of path loss (e.g., the path loss exponent is around 6.2 for deep tissue). Because of such inherently bad settings of the communication nodes, a multi-hop network topology is preferred in order to meet the transmit power requirements and to increase the battery lifetime of sensor nodes. This will ensure that the live body of a patient receiving the healthcare service has a reduced level of specific absorption ratio (SAR) when exposed to long-lasting radiation. We propose an efficientmethod for delivering delay-intolerant data packets over multiple hops. We consider forward error correction (FEC) in an erasure correction mode and develop a mathematical formulation for packet-level scheduling of delay-intolerant FEC packets over multiple hops. The proposed method can be used as a simple guideline for applications to setting up a topology for a medical body sensor network of each individual patient, which is connected to a remote server for u-healthcare service applications.

Correction Method of Tracking Error for Astronomical Telescope Using Recursive Least Square Method (재귀 최소자승법을 이용한 천체 망원경의 추적 오차 보정법)

  • Kwak, Dong-Hoon;Kim, Tae-Han;Lee, Young-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.224-229
    • /
    • 2012
  • In this paper, we propose a correction method for astronomical telescope using recursive least square method. There are two ways to move a telescope : equatorial operation and altazimuth operation. We must align polar axis of a equatorial telescope with the north celestial pole and adjust the horizontal axis of a altazimuth telescope exactly to match the celestial coordinate system with the telescope coordinate system. This process needs time and expertise. We can skip existing process and correct a tracking error easily by deriving the relationship of the celestial coordinate system and the telescope coordinate system using the proposed correction method. We obtain the coordinate of a celestial body in the celestial coordinate system and the telescope coordinate system and derive a transformation matrix through the obtained coordinate. We use recursive least square method to estimate the unknown parameters of a transformation matrix. Finally, we implement a telescope control system using a microprocessor and verify the performance of the correction method. Through an experiment, we show the validity of the proposed correction method.

Scattering Bar Optical Proximity Correction to Suppress Overlap Error and Side-lobe in Semiconductor Lithography Process (Overlap Margin 확보 및 Side-lobe 억제를 위한 Scattering Bar Optical Proximity Correction)

  • 이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.22-26
    • /
    • 2003
  • Overlap Errors and side-lobes have been simultaneously solved by the rule-based correction using the rules extracted from test patterns. Lithography process parameters affecting attPSM lithography process have been determined by the fitting method to the real process data. The correction using scattering bars has been compared to the Cr shield method. The optimal insertion rule of the scattering bal's has made it possible to suppress the side-lobes and to enhance DOF at the same time. Therefore, in this paper, the solution to both side-lobe and overlap Error has been proposed using rule-based confection. Compared to the existing Cr shield method, the proposed rule-based correction with scattering bars can reduce the process complexity and time for mask production.

  • PDF

A Study on Effective Correction of Internal Drag and Wall Interference Using Response Surface in Wind Tunnel Test (풍동시험에서 반응면을 이용한 내부 항력 및 벽면 효과의 효율적 보정방안 연구)

  • Kim, Junemo;Lee, Yeongbin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.637-643
    • /
    • 2019
  • Wind tunnel testing for flow-through model is necessary for performance prediction of an aircraft with air-breathing jet engine. Internal drag correction and wall correction are performed to acquire preciser wind tunnel test data. Many test runs are generally required to correct internal drag and wall interference in wind tunnel test. In this study we investigated more effective correction schemes using the response surface method. Even though the number of tests required for these schemes was much smaller than that for conventional methods, the differences between corrections using these schemes and conventional methods were similar level with the uncertainty of measurement except for the data near the boundaries.

A Study on Accuracy Improvement of SBAS Ionospheric Correction Using Electron Density Distribution Model

  • Choi, Bong-Kwan;Han, Deok-Hwa;Kim, Dong-Uk;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.8 no.2
    • /
    • pp.59-68
    • /
    • 2019
  • This paper proposed a method to estimate the vertical delay from the slant delay, which can improve accuracy of the ionospheric correction of SBAS. Proposed method used Chapman profile which is a model for the vertical electron density distribution of the ionosphere. In the proposed method, we assumed that parameters of Chapman profile are given and the vertical ionospheric can be modeled with linear function. We also divided ionosphere into multi-layer. For the verification, we converted slant ionospheric delays to vertical ionospheric delays by using the proposed method and generated the ionospheric correction of SBAS with vertical delays. We used International Reference Ionosphere (IRI) model for the simulation to verification. As a result, the accuracy of ionospheric correction from proposed method has been improved for 17.3% in daytime, 10.2% in evening, 2.1% in nighttime, compared with correction from thin shell model. Finally, we verified the method in the SBAS user domain, by comparing slant ionospheric delays of users. Using the proposed method, root mean square value of slant delay error decreased for 23.6% and max error value decreased for 27.2%.

A complete 3D map of Bell Glasstone spatial correction factors for BRAHMMA subcritical core

  • Shukla, Shefali;Roy, Tushar;Kashyap, Yogesh;Shukla, Mayank;Singh, Prashant
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3488-3493
    • /
    • 2022
  • Accelerator driven subcritical systems have long been discussed as facilities which can be used for solving the nuclear waste problem. The physics of these systems is very different from conventional reactors and new techniques had to be developed for reactivity monitoring. One such technique is the Area Ratio Method which studies the response of a subcritical system upon insertion of a large number of neutron pulses. An issue associated with this technique is the spatial dependence of measured reactivity which is intrinsic to the sub criticality of the system since the reactor does not operate on the fundamental mode and measured reactivity depends on the detector position. This is generally addressed by defining Bell-Glasstone spatial correction factor. This factor upon multiplication with measured reactivity gives the correct reactivity which is independent of detector location. Monte Carlo Methods are used for evaluating these factors. This paper presents a complete three dimensional map of spatial correction factors for BRAHMMA subcritical system. In addition, the dataset obtained also helps in identifying detector locations where the correction factor is close to unity, thereby implying no correction if the detector is used at those locations.

Quantitative Study of Annular Single-Crystal Brain SPECT (원형단일결정을 이용한 SPECT의 정량화 연구)

  • 김희중;김한명;소수길;봉정균;이종두
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.163-173
    • /
    • 1998
  • Nuclear medicine emission computed tomography(ECT) can be very useful to diagnose early stage of neuronal diseases and to measure theraputic results objectively, if we can quantitate energy metabolism, blood flow, biochemical processes, or dopamine receptor and transporter using ECT. However, physical factors including attenuation, scatter, partial volume effect, noise, and reconstruction algorithm make it very difficult to quantitate independent of type of SPECT. In this study, we quantitated the effects of attenuation and scatter using brain SPECT and three-dimensional brain phantom with and without applying their correction methods. Dual energy window method was applied for scatter correction. The photopeak energy window and scatter energy window were set to 140ke${\pm}$10% and 119ke${\pm}$6% and 100% of scatter window data were subtracted from the photopeak window prior to reconstruction. The projection data were reconstructed using Butterworth filter with cutoff frequency of 0.95cycles/cm and order of 10. Attenuation correction was done by Chang's method with attenuation coefficients of 0.12/cm and 0.15/cm for the reconstruction data without scatter correction and with scatter correction, respectively. For quantitation, regions of interest (ROIs) were drawn on the three slices selected at the level of the basal ganglia. Without scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.2 and 2.1, respectively. However, the ratios between basal ganglia and background were very similar for with and without attenuation correction. With scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.69 and 2.64, respectively. These results indicate that the attenuation correction is necessary for the quantitation. When true ratios between basal ganglia and background were 6.58, 4.68, 1.86, the measured ratios with scatter and attenuation correction were 76%, 80%, 82% of their true ratios, respectively. The approximate 20% underestimation could be partially due to the effect of partial volume and reconstruction algorithm which we have not investigated in this study, and partially due to imperfect scatter and attenuation correction methods that we have applied in consideration of clinical applications.

  • PDF

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF