• Title/Summary/Keyword: CORONA

Search Result 1,314, Processing Time 0.025 seconds

Experimental Study of DC Coronas in Point-to-Plane Short Gap (지간적 직류Corona의 실질적 검토)

  • 오철한;이성만
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.5
    • /
    • pp.157-163
    • /
    • 1983
  • Positive and negative coronas in point-to-plane short gap have been investigated with the variations of point radius and gap length. Mainly the onset potentials and current pulses under various conditions were measured with a 70 MHz C.R.O. and a precise-controllable D.C. power supply. In the case of negative corona, the Trichel pulse corona, glow corona and spark regions were distinguished apparently and the critical gap lengths between them were also found clearly. In the case of positive corona, there are streamer corona, spark regions and the critical gap length between them, too. The current pulse forms of Trichel pulse corona of negative and streamer pulse corona of positive are similar in rising time, peak-to-peak time and pulse width. The glow corona current shows D.C. component in form.

  • PDF

An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode (관형 코로나 방전전극을 이용한 이온풍속의 최대화)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

A Public Perception Study on the new word "Corona Blue":Focusing on Social Media Big Data Analysis

  • Ann, Myung Suk
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.133-139
    • /
    • 2020
  • The purpose of this study is to contribute to the provision of basic data for psychological quarantine policy and counseling by examining the public perception of the "corona blue" phenomenon through analysis of social media big data. To do this, key words related to the word 'Corona Blue' were derived and analyzed using the big data analysis program 'Textom'. As a result of the analysis, words such as 'Corona 19', 'depression', 'problem' and 'overcome' were derived as key words. For the analysis results,"pride and awarenes as the public perception of Corona 19", "depression and anxiety as a group trauma as the corona blue phenomenon", "spreading a psychological quarantine culture and demanding social healing as the perception of overcoming corona Blue," and "hope for return to daily life and changes in daily life as the perception of post corona" were discussed. In conclusion, we have identified the need for active psychological support from the community By revealing that Corona Blue is a depression as a group trauma. At this time, it is confirmed that it is necessary to prioritize social healing and psychological quarantine for the main risk groups such as youth or the vulnerable, who are the socially weak.

A Study on the Radio Interference due to the Corona Noise of 345 KV Transmission Line (345KV 송전선에 의한 CORONA 잡음 전파장해 연구)

  • 최기호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.4 no.1
    • /
    • pp.32-37
    • /
    • 1979
  • The corona noise level at the place 10m and the frequency 1MHz from the new 345KV transmission line is 72dB in the maximum rain-fall and 63dB due to the wet conductors. The synthesized corona noise level of all 3 phases dominantly depends on the phase which has maximum corona level among them. The measured characteristic of the variation with distance from the line coincided well with the theoretically calculated value in this paper. The corona noise level was the highest level in rainy weather or snow-fall. It takes a few hours, for the corona noise to be stable after a rain-fall or snow-fall. The measured value of the corona noise level corresponds quite well with the formula for the corona noise level revision. It was necessary to quantize S/N ratio into radio reception quality for the radio interference due to the transmission line. Some regulations for radio reception quality were defined through long term experiments and ratings by ITU, IEEE comittee, NHK in Japan and others. Fixing our own regulation about radio reception quality should be required.

  • PDF

Effect of Corona Treatment of Polymers on Bonds to Aluminum (高分子 物質의 表面에너지 增加에 對한 새로운 理論. 高分子 物質의 코로나 放電處理가 알루미늄과의 接着强度에 주는 影響)

  • Kim Chung Yup;Sung Ki Joong
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.5
    • /
    • pp.417-423
    • /
    • 1976
  • Corona treatment of PE, PP and PVC showed a dramatic increase of bond strength when lap joints were made between the polymers and aluminum plates. Heating the corona-treated PE and PP, and PVC in a drying oven at 80 and $50^{\circ}C$, respectively, for 15 min reduced the bond strength to about a half of that of corona-treated but unheated polymers, which indicated that the increase of bond strength was not due to oxidation of the polymer surface. The Weibull distribution function was employed to check reliability of the scattered data obtained from testing the lap joints. It is speculated that electron was deposited on the corona-treated polymer surface to enhance bond strength with aluminum.

  • PDF

Surface Discharge Characteristics of a DC Corona Charged Ferroelectric Pellet Barrier (직류 코로나 하전된 강유전체구 층의 연면방전특성)

  • Geum, Sang-Taek;Lee, Geun-Taek;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.385-390
    • /
    • 1999
  • Surface corona discharge characteristics of a dc corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charges stored on the surfaces of the ferroelectric pellets by a dc corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between corona tip and mesh electrode. Positive and negative dc voltages were applied to the tip to generate partial discharges, and corona currents were estimated to investigate the buildup charge on ferroelectric pellets as a function of the applied time and the charge relaxation time constants of ferroelectric pellets. As a result, in the case of the negative corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be fenerated efficiently. It is also found that, charge relaxation time, dielectric constants offerroelectric pellets, polarity of applied voltage and applied time affected to the surface discharges among the ferroelectric pellets.

  • PDF

ORGANIC POLLUTANTS DEGRADATION USING PULSELESS CORONA DISCHARGE: APPLICATION IN ULTRAPURE WATER PRODUCTION

  • Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.144-154
    • /
    • 2005
  • The use of ozone gained acceptance in the production of ultrapure water because of its powerful oxidizing ability. Ozone is currently used to deactivate microorganisms and remove organic contaminants. However, interest also exists in using radical species, which arc stronger oxidants than ozone, in such processes. One means of producing radical species is by corona discharge. This work investigates the use of a novel pulseless corona-discharge system for the removal of organic substances in ultrapure water production. The method combines corona discharge with electrohydrodynamic spraying of oxygen, forming microbubbles. Experimental results show that pulseless corona discharge effectively removes organics, such as phenol and methylene blue, in deionized water. The corona-discharge method is demonstrated to be comparable to the direct use of ozone at a high-applied voltage. The results also show that a minimum applied voltage exists for operation of the corona-discharge method. In this work, the minimum applied voltage is approximately 4.5 kV. The kinetic rate or phenol degradation in the reactor is modeled. Modeling results show that the dominant species of the pulseless corona-discharge reactor are hydroxyl radical and aqueous electron. Several radical species produced in the pulseless corona-discharge process are identified experimentally. The. major species are hydroxyl radical, atomic hydrogen species, and ozone.

A Study on the Collection Characteristics of Submicron Particles in an Electrostatic Precipitator - II. Collection Efficiency Characteristics (전기 집진기에서의 Submicron 입자의 집진 특성에 관한 연구-II. 집진 효율 특성)

  • 김용진;여석준;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.579-587
    • /
    • 2001
  • This study investigates particle collection characteristics of a cylindrical electrostatic precipitator. Experimental work has been made for the submicron particles. The effects of polarity of discharge electrode wire, particle diameter, gas velocity, gas temperature, and specific corona power on the particle collection efficiency are investigated. The efficiency of negative corona is higher than that of positive corona. as the particle diameter increases, the efficiency is decreased when the diameter is in the range of 0.02-0.6 micron, but is increased for the nanometer particles with diameter smaller than 0.02 micron. The efficiency is increased with increase of specific corona power. As the gas temperature increases, overall collection efficiency is increased for a negative corona, but is deceased for a positive corona.

  • PDF

Simulation of Charging Process in PTFE Electret (PTFE 일렉트렛트의 대전 과정 시뮬레이션)

  • Park, Geon-Ho;Kim, Sang-Jin;Sung, Nak-Jin;Bae, Duk-Kwun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.123-126
    • /
    • 2005
  • In this study, the Thermally Stimulated Current(TSC) of corona charged PTFE is studied and the simulation of corona charging process is also calculated by Finite Element Method. The electrets which were formed by applying high voltages (DC ${\pm}5{\sim}{\pm}8$ [kV]) to PTFE, are used to measure TSC in the temperature range of $-100{\sim}+200$ [$^{\circ}C$] and then the Finite Element Method is performed to examine corona charging process using a obtained physical constants. As a result. it is confirmed that the charging negative corona is profitable as the applications are manufactured, because the time constant of negative corona is much larger than it of positive corona. And it is attempted to estimate the corona charging process in space using simulation.

  • PDF

Characteristics of Ozone Generation by Diameter and Polarity Variation of Corona Wire Electrode (코로나 선전극의 직경과 극성변화에 따른 오존발생특성)

  • Jung, Jae-Seung;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.85-90
    • /
    • 2012
  • In this paper, it was investigated experimentally that diameter and polarity variation of corona wire electrode affected to ozone generation of the ozone generator using a wire-to-plate type electrode. The change in the diameter(D) of the corona wire electrode has a great effect upon ozone generation, higher influence appears in the positive corona discharge than the negative corona discharge. In the case of D=0.50[mm], maximum ozone generation and power efficiency could be obtained. However, in the case of smaller D than this, the ozone generation and efficiency decreases slowly and in the case of larger D, the ozone generation decreases rapidly. It means performance decline as an ozone generator. Therefore, ozone generation and power efficiency would increase through simple optimization of the corona electrode specification.