• 제목/요약/키워드: COOLING EFFECT

검색결과 2,349건 처리시간 0.03초

모터내장형 주축의 냉각특성에 관한 연구 (Study on the Cooling Effect of Motor Integrated Spindle)

  • 송영찬;이득우;최대봉;김수태
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.8-13
    • /
    • 1997
  • Generally, A motor integrated spindle is selected to perform the high speed machining, to improve the machining flexibility, and to simplify the structure of machine tools. The thermal deformation caused by heat generation of the integrated motor is, however, serious problem in motor integrated spindle system. In this study, cooling characteristics for the several kinds of cooling systems(such as, oil-jacket cooling, air cooling) are investigated and more efficient cooling method is presented. The results show that the shaft cooling by the air cooling system is effective to improve the thermal characteristic of motor integrated spindle.

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

수원시 녹지 조성 및 주변 환경에 따른 녹지 냉각 효과의 변화 (Variation of Green Space Cooling Effect Influenced by Its Composition and Surroundings in Suwon City)

  • 이승연;전성우
    • 환경영향평가
    • /
    • 제32권3호
    • /
    • pp.176-186
    • /
    • 2023
  • 도시열섬(Urban Heat Island; UHI)은 도시가 인근 지역에 비해 뜨거운 현상을 의미하며 도시 내부의 건물의 구성, 토지피복의 종류 등이 변화하기 때문에 발생한다. 도시열섬을 완화하기 위한 방법으로 녹지공간의 조성인데, 녹지가 제공하는 냉각효과의 경우 녹지의 내부 구성 요소 및 녹지의 크기에 따라 변화한다. 본 연구는 다양한 토지피복으로 구성된 수원시를 대상으로 녹지의 크기와 녹지를 구성하는 요소들에 따른 냉각효과의 차이를 확인하고, 녹지의 인근 토지피복에 따라 녹지로부터 제공되는 냉각효과의 차이를 고찰하고자 한다. 연구 결과, 녹지의 초기 온도는 산림의 비율이 높을수록, 그리고 호수가 존재할수록 낮아졌다. 냉각효과 중 하나인 냉각강도는 숲의 비율이 높을수록 강해졌지만, 초기 온도가 더 큰 영향을 미쳤다. 다만 냉각 거리는 녹지의 크기나 구성에 따라 달라지지 않음을 확인했다. 본 연구의 결과는 도시의 계획 시 열섬을 완화하기 위한 녹지 설계 방안을 제시한 다는 점에 의의를 가진다.

일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

공랭형 병렬방식 2중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System with Parallel Flow Type)

  • 오명도;김선창;김영인;이홍원
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2099-2109
    • /
    • 1993
  • A gas-fired 4RT absorption heat pump was designed as an air-conditioner for domestic use during the summer. The absorption heat pump is air-cooled. double-effect, $LiBr-H_{2}O$ system with parallel flow type. The performance of the absorption heat pump in the cooling mode of operation was investigated through cycle modeling and simulation to obtain the system characteristics with parameter changes. System parameters considered in this analysis were the inlet temperature of cooling air to the absorber, the working solution concentrations, the ratio of the amount of the weak solution from the absorber, and the LTD's of each heat exchange component. The optimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance.

다꾸지 기법에 의한 이륜자동차 브레이크 디스크의 마찰특성에 관한 연구 (A Study on Friction Characteristics for Motorcycle Disk Using Taguchi Experimental Design)

  • 전환영;류미라;이상재;박흥식
    • 동력기계공학회지
    • /
    • 제10권3호
    • /
    • pp.67-72
    • /
    • 2006
  • The effect of manufacturing parameters on wear and improve cooling of motorcycle break system was studied using a disk-on-pad type friction tester. Such parameters conditions have an effect on the wear and improve cooling factor such as applied load, sliding speed, frictional time and number of ventilated disk hole. However, it is difficult to know the mutual relation of these factor. In this study, the wear and cooling characteristics using design of experiment containing 4 elements were investigated for an optimal condition for the best motorcycle disk break system employing Taguchi robust experimental design. From this study, the result was shown that vents have an effect on convection area improving more cooling ability and reduced wear of the disk.

  • PDF

팁 클리어런스가 스트레이트 휜 히트싱크의 냉각성능에 미치는 영향에 관한 실험적 연구 (Experimental Study on the Effect of Tip Clearance for a Straight Fin Heat Sink)

  • 김진욱;김성진;민정임;이승규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1189-1194
    • /
    • 2004
  • In this paper, the effect of tip clearance on the cooling performance of the microchannel heat sink is presented under the fixed pumping power condition. For the various types of microchannel heat sink having different size of fin width and channel width, experimental study is conducted. Through the experiment, the tip clearance effect is investigated by increasing tip clearance from zero. As a result, it is shown that cooling performance of heat sink with tip clearance is better than that of heat sink without tip clearance. For the microchannel heat sink with tip clearance, the optimum conditions for cooling performance is also studied.

  • PDF

액체로켓 엔진의 분무연소 및 막냉각에 대한 수치해석 (Numerical Prediction of Spray Combustion and Film Cooling in a Liquid Rocket Engine)

  • 박태선;류철성
    • 한국추진공학회지
    • /
    • 제6권2호
    • /
    • pp.9-17
    • /
    • 2002
  • 난류분무 연소해석을 위한 수치해석 코드가 개발되었다. 복잡한 형상을 다루기 위하여 일반좌표계에서 이산화되었고 낮은 마하수 유동에 대한 수렴성을 증가시키기 위하여 예조건화기법과 고유치 재규격화기법이 도입되었다. 코트의 정확성은 캐비티 유동과 평면노즐에서 검증되었다. 액체로켓 엔진의 막냉각효과가 분무연소해석에 의하여 분석되었다. 막냉각은 연소효율에 부정적인 영향을 보였다. 연소실 벽면에서 막냉각효과는 연료가 많은 지역형성에 증진됨을 보여주었다.

학교 교실의 창호 환기 조절 모드에 따른 자연형 냉방효과 연구 (A Study on the Natural Cooling Effect by Ventilation Control Mode of Window at School Classroom)

  • 이효석;김순호;최정민
    • 한국태양에너지학회 논문집
    • /
    • 제38권4호
    • /
    • pp.67-76
    • /
    • 2018
  • Cooling the building by natural ventilation is one of the passive methods widely used from ancient times. It can be effectively applied especially in case of cooling load during the intermediate season of the year. In this study, the effect of 4 cases of window ventilation control mode which are 'Always Close', 'Temperature', 'Enthalpy' and 'Always Open' is simulated by Energyplus program and analyzed to improve the comfort of occupants and reduce energy consumption of the school classroom.

폐광의 냉기 및 냉수를 이용한 온실의 야냉 시스템 개발 (Development of Night Cooling System for Greenhouse Using Cool Air and Water from an Abandoned Coal Mine)

  • 강화석;강위수;이귀현;오재헌;김일섭;류근창
    • 한국환경농학회지
    • /
    • 제15권2호
    • /
    • pp.223-231
    • /
    • 1996
  • 폐광으로부터 유출되는 냉기 또는 냉수를 이용하여 여름 동안 야간에 온실을 냉방시키는데 있어 가장 효율적인 냉각방법을 결정하기 위해 여러 종류의 냉각 장치가 제작 및 냉각 실험되어졌다. 온실을 냉방시키는데 있어 여러 냉각장치의 효율을 비교할 때 독립적으로 소형 radiator, 냉각 pad 및 냉기를 사용한 냉각방법은 거의 비슷한 결과를 나타냈다. 또한 대형 radiator를 제외한 여러 냉각장치를 동시에 가동하였을 때는 독립적으로 이러한 냉각장치를 각각 가동하였을 때 보다 약간 향상된 냉각 효율을 나타냈다. 그러나 대형 radiator를 독립적으로 사용했을 때 온실의 냉각 효율은 다른 냉각 방법에 비하여 상당히 좋았으며, 야간의 외기 온도가 $23-24^{\circ}C$ 범위에 있을 때 온실내의 공기 온도는 약 $15^{\circ}C$로 냉각되었다.

  • PDF