• Title/Summary/Keyword: CONDITION FACTOR

Search Result 4,511, Processing Time 0.051 seconds

Simulation of electromigration behavior on ULSI′s interconnect under pulsed DC stress : frequency, duty factor, temperature effect (Pulsed DC 조건에서 반도체 배선의 electromigration 시뮬레이션 : 주파수, duty factor, 온도효과)

  • 이동현;안진호;박영준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.40-42
    • /
    • 2002
  • Electromigration is atomic diffusion driven by a momentum transfer from conducting electrons. With every new generation of intergrated circuits, interconnect line widths have been reduced and current densities in the interconnect have become higher. This leads to an increase in the threat to interconnect reliability due to electromigration. In this paper, we simulated stress evolution with changing temperature, duty factor(ratio of on time and pulse time), frequency under pulsed DC condition. As a result, we predict MTF(median time to failure) and found that exponent n is affected by changing temperature, duty factor.

  • PDF

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

Coprime factor reduction of plant in $H{\infty}$ mixed sensitivity problem

  • Um, Tae-Ho;Oh, Do-Chang;Park, Hong-Bea;Kim, Soo-Joong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.340-343
    • /
    • 1995
  • In this paper, we get a reduced order controller in $H^{\infty}$ mixed sensitivity problem with weighting functions. For this purpose, we define frequency weighted coprime factor of plant in $H^{\infty}$ mixed sensitivity problem and reduce the coprime factor using the frequency weighted balanced truncation technique. The we design the controller for plant with reduced order coprime factor using J-lossless coprime factorization technique. Using this approach, we can derive the robust stability condition and achieve good performance preservation in the closed loop system with reduced order controller. And it behaves well in both stable plant and unstable plant.t.

  • PDF

Stress Intensity Factor Calculation for the Semi-elliptical Surface Flaws on the Thin-Wall Cylinder using Influence Coefficients (영향계수를 이용한 원통용기 표면결함의 응력확대계수의 계산)

  • Jang, Chang-Heui;Moonn, Ho-Rim;Jeong, Ill-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.280-285
    • /
    • 2001
  • As an integral part of the probabilistic fracture mechanics analysis, stress intensity factor calculation scheme for semi-elliptical surface flaws in thin-walled cylinder has been introduced. The approximation solution utilizes the influence coefficients to calculate the stress intensity factor at the crack tip. This method has been compared with other solution methods including 3-D finite element analysis for cooldown boundary condition. The analysis results confirmed that the simplified methods provided sufficiently accurate stress intensity factor values for axial semi-elliptcal flaws on the surface of the reactor pressure vessel.

  • PDF

A Study on Mercury Emission Factor for Environmental Impact Assessment of Municipal Waste Incinerator (소각장 환경영향평가시 수은 배출 계수에 관한 연구)

  • Chun, Mee-Kyung;Park, Seok-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.113-125
    • /
    • 1998
  • The amount of mercury emitted from an incinerator depends on the properties of waste, combustion condition, and control devices. Mercury concentration in air proportionates to the increase of incinerator installation. The purpose of this study is to provide a method for determination of mercury emission factor which can predict the amount of mercury emitted from each incinerator specifically. Case study was performed for N municipal waste incinerator. Based on the method presented in this paper, we obtained mercury emission factor as 1.85~1.95 g Hg/t at N Municipal Waste Incinerator and this result was regarded as reasonable when compared with existing mercury emission factor in reference cases. Fluorescent lamps turned out to be the most important source(44.4%) of mercury in municipal waste and its amount will tend to increase, while batteries become less significant. In addition, medical waste is one of the major source of mercury.

  • PDF

Achitectural acoustic design for multi-purpose hall of J science museum (J 과학관(科學館) 다목적(多目的) 강당(講堂)의 건축음향설계(建築音響設計))

  • Kim, Dae-Goon;Choi, Dool;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.303-307
    • /
    • 2008
  • For the recently constructing building, diverse forms of attempt are being applied with the environmental-friendly design and reflection of the design factor by environment simulation. Especially, in case of Multi-Purpose Hall, in view of its use-purpose and because of the characteristics that should be utilized as the multipurpose uses by well-mingled together with the lecture-wise factor and musical factor, now it could be said that the sufficient examination and planning with regard to the acoustic factor are essential. On such viewpoint, as the object of practically planning multipurpose auditorium, this Study has intended to design such auditorium equipped with the optimal architectural acoustic factor, for the acoustic condition using Acoustic Simulation Technique at the planning stage.

  • PDF

A Study on Measuring Method in Technical Progress (기술진보 측정방법에 관한 일고안)

  • 박일근
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.59-66
    • /
    • 1980
  • The purpose of this paper to study on measuring method in technical progress. Technology is combination method of raw material and capital, land, labour. The first step to technical Progress is COBB-DOUGLAS production function, so technical progresses are important role in economic growth and development. General production function from Y=f(K, L, T) and COBB-DOUGLAS production function Y=${AK^I}{L^b}$ is first condition. Technical progress is saving of production factor In capital saving, labour saving, neutral saving. Marred Hicks Robinson has Insist on technical progress by each view of production factor, but, what is most excellent measuring method of technical progress\ulcorner I : productivity index method. II : Gross Production function method. Productivity method used in every products level in weight values, gross method function method used in production factor attributed to products. Above two measuring method has delicate problem in each input factor, substitution relation and production factor simultaneously linked each others This basic problem based on technical progress is not solubable in this time.

  • PDF

Importance perception on the sanitation and cleanliness of family restaurant employees (패밀리레스토랑 종업원의 위생과 청결에 관한 중요도 인식)

  • Ko Ho-Seok;Kim Sun-Kyung;Kim Dong-Ki;Kim Beom-Jin
    • Korean journal of food and cookery science
    • /
    • v.21 no.2 s.86
    • /
    • pp.155-162
    • /
    • 2005
  • The purpose of this study was to identify factors associated with sanitation and cleanliness regarding the importance of family restaurant employees in the Ulsan and Busan areas. Accordingly, this study conducted a suey questionnaire consisting of 28 measures of food-service as well as major subject descriptors. From the results, the frequency, descriptive, factor, correspondence analysis, major findings and marketing implications could be summarized as follows: First, 6 factors were extracted: cooking and control factor, food and tableware handling factor, personal cleanliness condition factor, purchase and receiving factor, unit food material store factor and Kitchen utensil sanitation factor. KMO and Bartlett' stest statistics showed that the data fitted the factor analysis well. Results of factor analysis, average variance extracted estimates and shared variance showed that the convergent and discriminant validity of 6 factors are supported and Cronbach's alpha showed that the internal consistency of the 6 factors was supported. Second, correspondence analysis indicated that statistically significant relationships existed between some of the family restaurant employee sanitation and cleanliness factors and the family restaurant enterprise.

A Study on the Analysis of User's Satisfaction at the Commercial Street of Historic and Cultural Environmental Districts in Gyeongju (경주시 역사문화환경지구 내 상업가로경관에 영향을 미치는 요인 분석)

  • Choi, Moo-Hyun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.3
    • /
    • pp.19-26
    • /
    • 2014
  • This study aims to examine residents' satisfaction and behavioral condition at the commercial street of Historic and Cultural Environmental Districts in Gyeongju. To achieve this, the study relied on empirical study method and additionally, present condition survey was performed with a user interview. residents' satisfaction and preferences analysis was conducted to figure out present conditions and improvements. This work has completed a total analysis of the architectural characteristics and street factors among various factors which influence residents' satisfaction level including physical street equipments and street view factors which are main contents of previous studies and street improvement project. Using statistical analysis, each factor's significance was verified quantitatively. Accordingly, this study presents prior consideration points before planning the commercial street improvement project and the region development project.

A Study on TRANSYT Model-embedded Parameters (TRANSYT 모델의 내재 모개변수에 관한 연구)

  • 도철웅
    • Journal of Korean Society of Transportation
    • /
    • v.6 no.1
    • /
    • pp.55-64
    • /
    • 1988
  • Prior to using any computer model, the program-embedded palameters showing significant differences from real world should be calibrated. This is especially true when the model is expected to be used fro various roadway and traffic condition. The calibration of TRANSYT model was conducted for the parameters of start-up delay, and lag, stop penalty(K), platoon dispersion factor, and saturation flow rate. The values of the parameters were obtained by theoretical methods from actual field measurements for discharging and arrival pattern. The sites elected for the study was an intersection of Dongil-Ro and Hwarang-Ro, and a 334 meter downstrean section from the intersection stop line on westbound Hwarang-Ro. The study results showed that the start-up delay was 2.6 sec, end lag was 1.0 sec, saturation flow rate was 2287 pcphgpl, platoon dispersion factor was 0.2-03, and stop penalty(K) was 32. However, since these parameters re apt to depend on traffic and roadway condition, it is doubtful whether the obtained values will be applicable to the area-wide situation other than this particular site.

  • PDF