• Title/Summary/Keyword: COILING

Search Result 162, Processing Time 0.025 seconds

Cladistic Analyses of Three Planorbid Snail Species (Gastropoda : Planorbidae) in Korea : Gyraulus convexiusculus,Hippeutis cantori and Segmentina hemisphaerula) (한국산 또아리물달팽이과 (Family Planorbidae) 3종에 대한 계통 분지 분석)

  • 정평림;정영훈;정은경
    • The Korean Journal of Malacology
    • /
    • v.9 no.2
    • /
    • pp.57-67
    • /
    • 1993
  • A cladistic analysis for phylogenetic relationship among 3 freshwater planorbid snail species was carried out on the basis of their conchological and anatomical characteristics.The intestinal loop in the digestive systims was mainly distinguishable among 3 species of the planorbid snails. The loops in Hippeutis cantori and Segmentina hemisphaerula coiled around stomach, extended down to the distal part of the liver and finally connected with the anus, while the loop in Gyraulus convexiusculus was short and small, and connected directly to the anus after coiling around the stomach. However, the intestinal loop of Hippeutis cantori was the largest among those of 3 target snail species. In the main morpholohical differences of the riproductive systems, Gyraulus convexiusculus uniquely had a calcareous stylet in the penis sheath. Although there was no stylet in the penis sheath in the other snail species, the penis shesths connected with 1 and 2 flagella in Segmentina hemisphaerula and in Hippeutis cantori, respectively were different from each other. Two planorbid species, Hippeutis cantori and Segmintina hemisphaerula have a more recent phylogenetic ancestor out three species employed including Gyraulus convexiusculus.

  • PDF

Life Prediction of High Pressure Hydraulic Hose Assemblies by the Impulse Test

  • KIM, Hyoung-Eui;LEE, Yong-Bum;Kwon, Young-Il
    • Corrosion Science and Technology
    • /
    • v.3 no.5
    • /
    • pp.209-215
    • /
    • 2004
  • Flexible hydraulic hose assembly that consists of hose and joints is used widely on various construction heavy equipments, agricultural machines, motor vehicles, and industrial heavy machines that require flexibility on hydraulic pipelines. It is classified by the maximum usage pressure which is determined by the winding layers of coiling steel wire and the inner diameter of the hoses. In this paper, we designed and performed an accelerated life test for assessing the reliability of a flexible hydraulic hose assembly. In the proposed accelerated life test, typical impulse pressure testing method is applied with the half omega flexing operation to simulate the practical flexing motion of the hose assembly.

Shape Design of Initial Section for Non-circular Shaped Mold Spring (비원형 단면을 갖는 금형스프링의 단면설계)

  • Lee, Hyoungwook;Choi, Hwaryong
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.24-28
    • /
    • 2011
  • The purposes of this study are predictions of the changes in the section geometry and determination of the initial cross section so that opposite side in height direction is exactly parallel after coiling process. Finite element analysis is carried out for the calculation of the sectional changes for mold spring item. Analysis results reveal that the slope of the top and bottom sides varies in the range of 5 to 8 degrees and the amount depends on the dimension of the outer diameter. The slopes of the sides should be defined first among design variables.

  • PDF

Upward Migration of a Peritoneal Catheter Following Ventriculoperitoneal Shunt

  • Cho, Kyung Rae;Yeon, Je Young;Shin, Hyung Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.383-385
    • /
    • 2013
  • We present an unusual case of peritoneal catheter migration following a ventriculoperitoneal shunt operation. A 7-month-old infant, who had suffered from intraventricular hemorrhage at birth, was shunted for progressive hydrocephalus. The peritoneal catheter, connected to an 'ultra small, low pressure valve system' (Strata$^{(R)}$; PS Medical,Gola, CA, USA) at the subgaleal space, was placed into the peritoneal cavity about 30 cm in length. The patient returned to our hospital due to scalp swelling 21 days after the surgery. Simple X-ray images revealed total upward migration and coiling of the peritoneal catheter around the valve. Possible mechanisms leading to proximal upward migration of a peritoneal catheter are discussed.

The Changes of Temperature for Embedded Duct Ventilation System in Ondol (바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰)

  • Kim, Ok;Park, Jin-Chul;Kim, Nam-Gyu;Oh, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

40-W 200-ns 300-kHz Thulium-doped Fiber Laser at 2050 nm

  • Shin, Jae Sung;Cha, Yong-Ho;Chun, Byung Jae;Park, Hyunmin
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.544-553
    • /
    • 2021
  • A 40-W 200-ns 300-kHz thulium-doped fiber laser at 2050 nm with a master oscillator power amplifier configuration was developed, for application to lithium-isotope separation. The master oscillator generated a 5.35 W continuous-wave beam, which the pulse generator then broke into 200-ns pulses at 300 kHz. Then, the laser beam was amplified by passing through a two-stage amplifier. The output power finally obtained was 42.0 W at 2050 nm, and was stable for a long time, over 2 hours. In spite of this achievement, mode instability was observed in the output beam. This can be solved in the future by using a method such as tight coiling.

Successful nonoperative management of a simultaneous high-grade splenic injury and devascularized kidney in Australia: a case report

  • Peter Thanh Tam Nguyen;Jeremy M. Hsu
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.431-434
    • /
    • 2023
  • Severe blunt injuries to isolated solid abdominal viscera have been previously managed nonoperatively; however, management algorithms for simultaneous visceral injuries are less well defined. We report a polytrauma case of a 33-year-old man involved in a motorbike collision who presented with left-sided chest and abdominal pain. Initial imaging demonstrated multiple solid organ injuries with American Association for the Surgery of Trauma (AAST) grade V splenic injury and complete devascularization of the left kidney. The patient underwent urgent angioembolic coiling of the distal splenic artery with successful nonoperative management of simultaneous grade V solid organ injuries.

Endovascular Management of Iatrogenic Vertebral Artery Pseudoaneurysm: A Case Report (의인성 척추동맥 가성동맥류에 대한 중재적 치료: 증례 보고)

  • Jae Yang Park;Sanghyeon Kim;Myongjin Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.483-488
    • /
    • 2023
  • Iatrogenic injury of the vertebral artery during cervical spine surgery though uncommon is critical. With advances in interventional endovascular techniques, the therapeutic approach for vertebral artery injuries has changed. Nonetheless, an established strategy for their management is lacking. We report a case of pseudoaneurysm due to vertebral artery injury, during cervical spine surgery for a tumor, that was treated successfully with endovascular coiling in a plug-and-patch fashion after triple stenting failed.

Result of Extracranial-Intracranial Bypass Surgery in the Treatment of Complex Intracranial Aneurysms : Outcomes in 15 Cases

  • Park, Eun-Kyung;Ahn, Jae-Sung;Kwon, Do-Hoon;Kwun, Byung-Duk
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.228-233
    • /
    • 2008
  • Objective : The standard treatment strategy of intracranial aneurysms includes either endovascular coiling or microsurgical clipping. In certain situations such as in giant or dissecting aneurysms, bypass surgery followed by proximal occlusion or trapping of parent artery is required. Methods : The authors assessed the result of extracranial-intracranial (EC-IC) bypass surgery in the treatment of complex intracranial aneurysms in one institute between 2003 and 2007 retrospectively to propose its role as treatment modality. The outcomes of 15 patients with complex aneurysms treated during the last 5 years were reviewed. Six male and 9 female patients, aged 14 to 76 years, presented with symptoms related to hemorrhage in 6 cases, transient ischemic attack (TIA) in 2 un ruptured cases, and permanent infarction in one, and compressive symptoms in 3 cases. Aneurysms were mainly in the internal carotid artery (ICA) in 11 cases, middle cerebral artery (MCA) in 2, posterior cerebral artery (PCA) in one and posterior inferior cerebellar artery (PICA) in one case. Results : The types of aneurysms were 8 cases of large to giant size aneurysms, 5 cases of ICA blood blister-like aneurysms, one dissecting aneurysm, and one pseudoaneurysm related to trauma. High-flow bypass surgery was done in 6 cases with radial artery graft (RAG) in five and saphenous vein graft (SVG) in one. Low-flow bypass was done in nine cases using superficial temporal artery (STA) in eight and occipital artery (OA) in one case. Parent artery occlusion was performed with clipping in 9 patients, with coiling in 4, and with balloon plus coil in 1. Direct aneurysm clip was done in one case. The follow up period ranged from 2 to 48 months (mean 15.0 months). There was no mortality case. The long-term clinical outcome measured by Glasgow outcome scale (GOS) showed good or excellent outcome in 13/15. The overall surgery related morbidity was 20% (3/15) including 2 emergency bypass surgeries due to unexpected parent artery occlusion during direct clipping procedure. The short-term postoperative bypass graft patency rates were 100% but the long-term bypass patency rates were 86.7% (13/15). Nonetheless, there was no bypass surgery related morbidity due to occlusion of the graft. Conclusion : Revascularization technique is a pivotal armament in managing complex aneurysms and scrupulous prior planning is essential to successful outcomes.

Isolation, Identification and Antagonisms of Rhizospheric Antagonists to Cucumber Wilt Pathogen, Fusarium oxysporum f. sp. cucumerinum Owen (오이 덩굴쪼김병균에 대한 오이 근권길항미생물의 분리, 동정 및 길항작용)

  • Jee Hyeong Jin;Kim Hee Kyu
    • Korean Journal Plant Pathology
    • /
    • v.3 no.3
    • /
    • pp.187-197
    • /
    • 1987
  • Bacteria and fungi antagonistic to Fusarium oxysporum f. sp. cucumerinum Owen were effectively isolated with each of modified Triple Layer Agar (TLA) technique from rhizosphere soil where cucumber had been grown healthily in plastic film house. Three predominant bacterial isolates selected were identified as Pseudomonas fluorescens, and P. putida, Serratia sp. and three fungal isolates were Gliocladium sp. Trichoderma harzianum, and T. viride. Antagonistic bacteria inhibited $26-45\%$ of germination and $41-56\%$ of germ tube elongation of microconidia of F. oxysporum f. sp. cucumerinum on Water Agar (WA). P. fluorescens was the strongest inhibitor. Several my co parasitisms were observed on dual culture of WA between antagonistic fungi and F. oxysporum f. sp. cucumerinum such as coiling, penetration, overgrowing, and lysis. Mycelial lysis of the pathogen was the most severe at pH 4.6, followed by 3.6, 5.6 and 6.6 of the medium in decreasing order. At pH 6.6, mycelia of the pathogen were not conspicuously damaged, however, the antagonistic fungi formed abundant chlamydospores especially Gliocladium sp. T. harzianum revealed the most excellent antagonism in vitro.

  • PDF