• Title/Summary/Keyword: CODcr

Search Result 109, Processing Time 0.031 seconds

Optimal Mixing Ratio of Wastewater from Food Waste and Cattle Manure and Hygienic Aspect in Batch Type Anaerobic Digestion (음식물폐수와 축산분뇨의 혼합소화에서 적정 혼합비 및 소화슬러지의 위생성 연구)

  • Jeong, Doo-Young;Chung, Myung-Hee;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.2
    • /
    • pp.93-100
    • /
    • 2009
  • This research was performed to figure out the optimal mixing ratio of food- to livestock wastewater for the best degradation of organic matter in the anaerobic digestion. The presence of various microorganisms, such as Escherichia coli and Staphylococcus aureus, was also investigated in both wastewater in this process. Enteric bacteria were only found in livestock wastewater, whereas pathogenic bacteria like S. aureus were detected in both wastewater. The optimal mixing ratio of food- to livestock wastewater for the best mineralization was found to fifty to fifty, with reduction ratios of $BOD_5$, CODcr SS as 23.2%, 24.7%, 19.7%, respectively. Hygiene of the digested sludge was also analyzed by counting the number of total colonies and various pathogens. Enterobacteriaceae including E. coli were barely detected in 10 days after reaction. Meanwhile, S. aureus was gradually reduced during reaction, even showing 1,000~5,000 CFU/mL in final days.

Comparison of Reduction Effect of Contaminants and Odor According to DO Change and EM Addition in Maturation Process of Piggery Slurry (양돈장 분뇨의 부숙 과정에서 DO 변화와 EM의 첨가에 따른 오염물질 및 악취 저감효과의 비교)

  • Kang Kyung-Ho;Kam Sang-Kyu;Hu Chul-Goo;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.563-569
    • /
    • 2006
  • It was compared the reduction effect of contaminants and odor according to DO change and EM (effective microorganisms) addition in maturation process of piggery slurry. The maturation processes were divided into three cases as follows: R-1 was operated at $2.5mg/{\ell}$ of DO without the addition of EM, R-2 was operated at $7.5mg/{\ell}$ of DO without the addition of EM and R-3 was operated at $2.5mg/{\ell}$ of DO with the addition of EM. The addition of EM was more effective than the increase of DO for the reduction of CODcr, $NH_3-N$ and T-N in the maturation of piggery slurry. In addition, the reducing effect of odor intensity appeared high even in the short-term maturation period in case of adding EM and one could not even smell the stimulating odor of piggery slurry.

고효율 자외선/광촉매 시스템을 이용한 고농도 유기성 폐수처리

  • Jeong, Hyo-Gi;Kim, Jung-Gon;Kim, Si-Uk
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.272-276
    • /
    • 2005
  • Food wastewater derived from three-stages methane fermentation system showed high concentrations of sCOD, T-N and $NH_{3}-N$. To treat the organic wastewater, the optimal operating conditions for high efficiency $UV/TiO_{2}$ photocotalytic system have been investigated. In the first process, wastewater was pre-treated with $FeCl_{3}. The optimum pH and concentration for coagulation were 4.0 and 2000 mg/L, respectively. Through this process, 52.6% of $COD_{cr}$ was removed. The second process was $UV/TiO_{2}$ photocatalytic reaction. The optimum conditions for the operation of $UV/TiO_{2}$ photocatalytic system developed in this lab have been studied. In this process, CODcr was removed from 2890 to 184 mg/L and T-N was removed from 2496 to 914 for 24 hours, respectively.

  • PDF

Application of the Thermophilic Aerobic Oxidation (TAO) System to Anaerobic Digestate Stabilization in Korea (혐기소화액의 고온호기산화 공정 적용에 관한 연구)

  • Kim, Soo-Ryang;Kim, Ha-Je;Nizel, Halder Joshua;Rhee, Ji-Hae;Shin, Myoung-Chul;Kim, Tae-Ha;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.21 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • We studied the possibility on the application of the Thermophilic Aerobic Oxidation (TAO) process to anaerobic digestate stabilization. In treating digestate with TAO reactor the internal temperature of the reactor was increasing higher and $51^{\circ}C$ and over was maintained after 6 days on. The physiochemical compositions of liquids increased from pH 8.1 to 9.8 and EC decreased from 29.8 to 12.0 mS/cm in treating process of digestate with TAO reactor. CODcr decreased from 22,654 to 18,843 mg/L, showed about 16.82% of remove efficiency. TN and $NH_4-N$ decreased from 4,813 to 1,733 mg/L, from 3,815 to 812 mg/L respectively, which showed about 64.0% and 78.7% of removal efficiency respectively.

Runoff Characteristics of the Livestock Manure as Fertilizer at Farmland (가축분뇨 비료의 농지 유출 특성)

  • Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.775-780
    • /
    • 2010
  • Over 90% of the livestock excretions were treated and utilized by land application in Korea. Excessive application of the livestock manure as fertilizer has been issued as a main pollutant source in groundwater and watersheds. This study was seasonally conducted to identify the discharging characteristics with a certain artificial rainfall intensity (13 mm/hr) in terms of surface runoff, groundwater, and soil residue mass depending on the livestock manure types. A experimental field was constructed with three different sites that pig liquid fertilizer (LF), cattle manure (CM), and standard (S). The pig liquid fertilizer of 1,200 L and cattle manure of 900 kg were sprayed on each site ($50m^2$). The standard area was firmly prevented from any other contaminants. In the LF site, farmland discharging rate (FDR) was computed as 0.006 in CODcr, 0.015 in TN, and 0.029 in TP, resulted from the mass balance among total injection mass, surface runoff and groundwater. In the CM site, 29% of the nitrogen and phosphorus in each were discharged to the surface, and 64% and 58% of them were remained in the farmland. Surface runoff rate of the CM was higher than that of the LF, resulted from the solid form of the CM.

Evaluation on Enhanced Biodegradability in Landfill Leachate by Fenton Oxidation (Fenton 산화법에 의한 매립장 침출수의 생물 분해성 증진에 관한 평가)

  • Lee, Byung-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.250-256
    • /
    • 2005
  • This study was aimed to investigate treatment feasibility of leachate from D landfill that is located in gyr대ungbuk. From the analytical results of leachate, organic and nonbiodegradable matters were contained in high concentration. Thus chemical treatment was introduced to degrade nonbiodegradable matters in pre or post biological process. Two types of Fenton oxidation were adapted in this study. The first one is pre treatment process before biological treatment. The second one is post treatment process after biological treatment. The optimal conditions of both treatment methods were investigated as follows. In case of pre treatment process, the optimal conditions appeared in $Fe^{+2}/H_2O_2$(mmol/mmol): 0.1, $H_2O_2/CODcr$(mg/mg): 27.0, pH: 3 and reaction time: 2hrs. On the other hand, in case of post treatment process, the optimal conditions appeared in $Fe^{2+}$(mmol/mmol): 0.14, $H_2O_2/COD_{cr}$(mg/mg): 57.4, pH: 3 and reaction time: 1.25hrs. In the above optimal conditions, high COD removal was obtained in pre and post treatment process. Also it can expect that Fenton oxidation converted nonbiodegradable matters into biodegradable matters.

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

The Assessment of Stabilization of Open-dumping Landfill Leachate - A Case Study of Noeun Landfill - (비위생매립지 침출수의 안정화 평가 - 노은매립지 사례연구 -)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.3
    • /
    • pp.115-124
    • /
    • 2004
  • To utilize a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill leachate. To assess leachate stabilization of an open-dumping municipal solid waste landfill (Noeun Landfill) which is located at the upper drainage basin of Namhan River which flows into Lake Paldang utilized for Seoul Metropolitan water supplies, the surrounding characteristics of the landfill site was surveyed. After then, leachate, groundwater and soil samples from this landfill were chemically analyzed, and the analysis results were evaluated by "The Criteria of Landfill Waste Stabilization(CLWS)", "Discharge Criteria of Landfill Leachate", "The Criteria of Domestic Use in Groundwater Quality", and "Soil Contamination Criteria" promulgated by Korean Ministry of Environment. The closed open-dumping landfill was equipped with the final soil cover, 3 groundwater monitoring wells and poor landfill gas extraction devices for the post-closure management of the landfill. BOD/CODcr ratios in leachate were less than or slightly higher than 1/10. This results seemed to imply that the leachate stabilization level of this landfill based on the CLWS was almost completed. Qualities of groundwater sampled from monitoring wells located at outside of landfill were adequate for "The Criteria of Domestic Use in Groundwater Quality". Finally, concentrations of soil contaminants that were likely to be influenced by this landfill site were adequate to "Soil Contamination Criteria".

Characterization of Combined Sewer Overflows from a Small Urban Watershed and Determination of Optimum Detention Volume (소규모 도시유역 합류식 하수관거 월류수 특성화 및 최적 저류지 용량 결정)

  • Jo, Deokjun;Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.314-320
    • /
    • 2006
  • Diffuse pollution from an urban area contributes to the significant pollution loading to a receiving water body. In this paper, rainfall runoffs from an urban basin with combined sewer systems located in the city of Daejeon were monitored to measure the rainfall runoff discharge rates and pollutant concentrations. Strong first flush effects were observed for all monitored rainfall runoffs. The first flush effects were closely related to rainfall intensity, while suspended solids were closely related to pollutant constituents. The observed averaged Event Mean Concentrations (EMCs) of Combined Sewer Overflows (CSOs) were 536.1 mg SS/L, 467.7 mg CODcr/L, 142.7 mg BOD/L, 16.5 mg TN/L, and 13.5 mg TP/L. Storage volumes for containing the first flush to improve water quality of the receiving stream can be estimated based on suspended solid concentration. In this study, retainment of the first flush equivalent to 5mm of precipitation could reduce diffuse pollution loading induced by CSOs to a receiving water body by up to 80% of suspended solid loading.

Reuse of Weaving Wastewater with BAF Process (BAF 공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.