• 제목/요약/키워드: CODcr

검색결과 109건 처리시간 0.031초

가축분뇨처리시설과 연계한 상향류식 인공습지의 자연형 후속처리공정 적용방안에 관한 연구 (A study on application of eco-friendly follow-up process connected with livestock wastewater treatment plant using the upflow constructed wetland)

  • 최한나;조은하;강호근;박주현;강선홍
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.359-370
    • /
    • 2015
  • This study developed an up-flow wetland providing either an eco-friendly follow-up process of medium-sized public treatment facility for livestock manure or a non-point source pollution controller near livestock farms. The four bench-scale up-flow wetlands were operated with four different bed media sets. The removal efficiencies of the wetland effluent for CODCr, TN, TP, SS were 35.2 %, 29.5 %, 31.2 % and 52.2 % for set 1(Blank, without reed, with bio-ceramic), 40.6 %, 43.4 %, 42.2 % and 55.4 % for set 2(with bio-reed & without bio-ceramic), 45.2 %, 48.7 %, 46.6 % and 66.3 % for set 3(with bio-reed & bio-ceramic), 32.9 %, 27.3 %, 29.3 % and 54.1 % for Set 4(with reed & bio ceramic), respectively. The set 3 condition having a mixture of bio-reed and bio-ceramic showed the highest efficiency in the bench-scale evaluation. This study suggests a mixture of bio-reed and bio-ceramic as suitable bed media in the construction of artificial wetlands near livestock farms. Soils including the bed media were monitored during the evaluation for trace elements. Soil analysis results were satisfied with the Korean Soil Contamination Standard. This study showed that the up-flow constructed wetland was feasible to treat the effluent livestock wastewater treatment facility.

Denitrifying Phosphate Accumulating Organisms (dPAOs)을 이용한 영양소제거 및 반응조내 미생물 분포 조사 (Nutrient Removal using the Denitrifying Phosphate Accumulating Organisms (dPAOs) and Microbial Community Analysis in Anaerobic-Anoxic Sequencing Batch Reactor)

  • 박용근;이진우;이한웅;이수연;최의소
    • 미생물학회지
    • /
    • 제38권2호
    • /
    • pp.113-118
    • /
    • 2002
  • 혐기-무산소조건으로 구성된 회분식 반응조에서 질산염을 이용하여 인(P)도 동시에 제거될 수 있는 가능성을 알아보기 위해서 인의 제거 양상을 혐기-호기조건의 반응조와 비교하여 조사하였고, 질산염과 인을 동시에 제거하는 미생물분포를 분석하였다. 그 결과 비교적 낮은 농도의 유기물이 적용되었을 때(평균 CODcr=130mg/ι)두 반응조 모두 인이 효과적으로 제거되었으며 반응조내의 최종 인의 농도를 1 mg P/L. 이하로 유지하였다. 특히, 질산염을 전자수용체로 이용한 혐기-무산소조건의 반응조는 기존의 영양소제거 시스템과 비교하여 5-7 mg (P+N)/ι의 영양소를 추가적으로 제거하여 유기물의 효과적 인 이용이 가능한 것으로 판명되었다. 혐기-무산조 조건의 방응조내 미생물 분포를 조사 한 결과 질소원을 제거하는 미생물군(denitrifying bacteria)과 인을 제거하는 미생물군(polyphosphate accumulating bacteria)이 함께 존재하고 있음이 밝혀졌고, 이들 중 $\beta$-proteobacteria에 속하는 Zoogloea ramigera와 Rhodocyclus에 포함되는Alcaligenes defragrans 등은 탈질능력 이 있으면서 anoxic상태에서 인을 동시에 축적할 수 있는 탈질-탈인균주(denitrifying phosphate accumulating organisms; dPAO)로 조사되었다.

웨이브렛 변환계수의 트리구졸르 이용한 방송용 HD-VCR의 부호화 기법 (Tree structured wavelet transform coding scheme for digital HD-VCR)

  • 김용규;정현민;이병래;강현철
    • 한국통신학회논문지
    • /
    • 제22권8호
    • /
    • pp.1790-1802
    • /
    • 1997
  • 웨이브렛 변환을 이용하여 방송용 HD-VCR(high definition video cassette recorder)의 요구조건들을 충족시키는 부호화 기법을 제안한다. 고정 비트율(constant bit rate)을 얻기 위하여, 앞 화면(frame)의 부호화 결과를 토대로 현재 화면의 양자화 간격을 결정하는 전망 제어 기법(forward rate control)과, 독립부호(IDC : independently decodable code) 와 종속부호(DOC: dependently dccodable code)로 구성되는 2단계 부호기(2 level codcr) 기법을 제안한다. 에러(error)의 확산을 최소화시키기 위하여, 전체 변환영상을 변환블록(transform block)으로 재구성하고, 각 변환 블록을 트리구조(tree structure)로 표현하여 독립적으로 부호화한다. 실험 결과 제안한 부호화 기법은 기존의 DCT(discrete cosine transform)를 사용한 부호화 기법 보다 같은 압축률에서 블록현상(block effect)이 없는 우수한 화질을 나타냈다. 제안한 전방 제어 기법과, 2단계 부호기를 이용하여 매우 정교한 비트량 제어(rate control)를 구현하였다.

  • PDF

CSTR의 수리학적 부하율이 돈슬러리의 유기물 및 영양염류 저감효율에 미치는 영향 (Effect of Hydraulic Loading Rate of a Continuous Stirred Tank Reactor(CSTR) on the Removal Efficiency of Pollutants of Pig Slurry)

  • 정우철;최홍림
    • 한국축산시설환경학회지
    • /
    • 제5권3호
    • /
    • pp.189-196
    • /
    • 1999
  • Anaerobic digestion is a naturally occuring microbial process involving the decomposition of organic materials such as livestock manure. This study explores the effect of the operating conditions, HRT (Hydraulic Retention Time) and feeding frequency on treatment efficiency for digestion of pig slurry, which has been one of most difficult organic waste for proper treatment in livestock production industry in Korea at the present time. The pilot-scale CSTR of 5 m3 in volume was designed. manufactured, and operated at the temperature of 35$\pm$1$^{\circ}C$. The digester was designed to hydraulically stir for complete mixing and to supply heat from the water bath to maintain mesophilic temperature. The HRT of the digester for Test 1 and Test 2, and Test 3 was set for 17 days and 13 days respectively and pig slurry was fed once a day with 300$\ell$ each for Test 1 and Test 3, while twice with 150$\ell$each for Test 2. Test 2 showed better performance by increase of 4% in VS removal efficiency and 5% in biogas production rate. This is mainly attributed to smaller temperature drop by feeding frequently with half amount, which eventually led to lesser impact on anaerobic mocrobes in the digester. Test 2 maintained optimum pH 7.8 which uplifted the activaton of sulfur-reduction bacteria, alkalinity of around 4,000mg/$\ell$, VA of over 3,000mg/$\ell$ for whole period of experiment. Further research may require to provide the practical operation strategy of anaerobic treatment system for treatment of pig slurry.

고랭지 밭에서 발생하는 비점오염물질의 초기세척효과 분석 (Analysis of First Flush of NPS Pollution from Upland Field)

  • 신재영;이수인;박병기;주소희;최중대
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.567-567
    • /
    • 2016
  • 비점오염원은 강우시 토지이용형태에 따라 유출특성이 다양하게 나타나며, 특히 강우 초기에 고농도의 유출수가 수계로 유입하게 된다. 또한 강우량, 강우강도, 선행건기일수 등은 비점오염물질의 농도에 영향을 미치며, 특히 선행건기일수가 길고 강우강도가 강한 강우사상일 경우 고농도의 오염물질이 배출되는 것으로 나타나고 있다(안태웅 등, 2012). 이에 본 연구에서는 3년간(2010년 ~ 2012년)의 모니터링을 통해 고랭지 밭에서 발생하는 비점오염물질의 초기세척효과를 분석하고자 하였다. 초기세척효과의 판단은 Geiger(1987)이 제시한 누적오염부하량과 누적유출량과의 그래프를 비교하여 기울기가 45도 기울기보다 상향하여 분포하였을 경우 양분선과 최대로 벌어진 부분의 시간까지에서 초기세척효과가 발생한다고 판단하였다. 연구결과, 고랭지 밭 지역의 경우 뚜렷한 초기세척효과 현상이 나타나지 않았다. 하지만 CODCr의 경우 3차 강우사상에서 초기세척 효과가 나타난 것으로 분석되었다. 3차 강우사상은 선행건기일수가 0.9일로 매우 짧고 발생강우량이 27.3 mm로 연구기간 동안 가장 적은 강우량이 관측되었지만, 유출발생시점 전후 3시간 동안 강우강도가 4.0 ~ 6.2 mm/hr로 높게 나타났기 때문에 유출초기에 고농도의 오염물질이 발생된 것으로 판단된다. 그동안 선행된 초기세척효과에 대한 연구를 살펴본 결과 이병수 등(2008)은 경안천 유역 농업지역에 대해 초기세척효과를 분석한 결과 일부 강우에서는 초기세척현상이 나타나지만 대부분의 강우에서는 초기세척현상이 나타나지 않아 농촌지역의 경우 초기세척현상의 접근방법은 적절치 않다고 보고하고 있다. 정성민 등(2009)은 고랭지 농업지역에서 SS와 TP는 뚜렷한 초기세척현상이 나타나는 반면, TN과 DOC는 경향을 보이지 않는다고 하였다. 하지만 윤영삼 등(2011)은 강우시 포도밭에서 초기세척효과를 분석한 결과 모든 수질항목에서 약한 초기세척효과가 나타났고 특히 SS의 경우 초기세척효과가 강하게 나타났다고 보고하고 있다. 이처럼 투수지역에서의 초기세척효과에 대한 판단은 연구자에 따라 차이를 보이는데 이러한 이유는 투수지역의 토양의 특성, 강우조건, 지형적 특징 등이 영향을 미치는 것으로 판단된다.

  • PDF

소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선 (Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater)

  • 이재엽;제스민아터;김일호
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

고수분 돈분슬러리의 톱밥여과 퇴비화 현장적용 연구 (A Practice-Oriented Study on Sawdust File Filteration Composting of High Moisture Pig Slurry)

  • 류종원
    • 한국축산시설환경학회지
    • /
    • 제14권2호
    • /
    • pp.129-138
    • /
    • 2008
  • 본 연구는 고수분 돈분뇨슬러리를 재료로 하여 톱밥여과 호기성 퇴비화 현장시설의 환경요인과 효율을 구명하기 위하여 퇴비화 과정중 온도, 수분함량, 물질수지, 수분증발량, 침출수 발생량, 퇴비 품질을 조사하였다. 분뇨투입은 퇴비화 초기에는 매일 분뇨를 투입하고 $2{\sim}3$주 이후에는 1주일에 2회씩 투입하여 처리하게 설계하였다. 본 시험에서는 발효조에 톱밥을 채우고 6개월간 지속적으로 분뇨를 발효장에 살포하고 교반하여 연속 호기성 발효 처리하는 퇴비화 방식의 농가에서 시험이 수행되었다. 1. 퇴비발효상의 온도는 상층부 $57.7^{\circ}C$, 중간부 $50.9^{\circ}C$, 하층부 $44.4^{\circ}C$를 나타내어 상층부가 가장 높고 하층부가 가장 낮았다. 교반 후 $3{\sim}5$시간 후부터 온도가 $36{\sim}50^{\circ}C$로 저하되었으며 교반 8시간 후부터 온도가 $64.5^{\circ}C$로 상승하여 정상온도를 유지하였다. 퇴비발효상 내부 온도의 일중 변화는 크지 않는 $20{\sim}30^{\circ}C$ 범위에 있었으나 상대습도는 $50{\sim}99%$로서 변화가 매우 컸다. 2. 퇴비발효상의 수분수지를 산출한 결과 총 투입수분량의 10.3%가 침출수로 배출되었고, 78.4%는 증발량으로 배출되었다. 본 호기성 퇴비화 시설은 수분 증발량이 높아 침출수 배출량을 제외하고 톱밥 $1m^3$$3.16m^3$의 슬러리 처리가 가능하여 수분조절제인 톱밥의 절감효과가 있었다. 3. 퇴비발효상 여과 침출액의 수질은 투입 슬러리 대비 BOD는 89.5%, CODcr는 81.2%, SS는 97.5% 저감되었다. 4. 최종 퇴비의 품질은 유기물은 29.1%, OM/N의 비율은 46.9%이었으며 중금속 함량은 비료공정규격 기준에 적합하였다.

  • PDF

소규모 빗물처리시설 개발 및 현장 적용성 평가 연구 (Development of Domestic Rainwater Treatment System and its Application in the Field)

  • 박기정;박민승;김환석;임윤수;김성표
    • 한국습지학회지
    • /
    • 제18권1호
    • /
    • pp.24-31
    • /
    • 2016
  • 도시화에 따른 불투수면 증가로 인한 자연적 물순환 시스템 왜곡 현상과 더불어 불투수면에 축적된 다양한 오염물질은 강우 시 유역 및 하천으로 유입되어 다양한 오염을 일으킨다. 특히 대부분의 강우가 여름철에 집중되는 국내 계절적 특성은 집중호우에 따른 비점오염물질의 수계 과대 유입에 대한 우려를 높이고 있어, 이를 효과적으로 처리하고 재이용하기 위한 다양한 형태의 빗물처리 및 재이용 시설에 대한 연구가 필요하다. 이를 위해 본 연구에서는 강우시 지붕 유출수의 오염특성을 파악하고, 강우 초기 고농도 빗물 유출수를 효과적으로 처리하기 위한 소규모의 빗물정원 포함 형태의 빗물처리시설을 구성하였으며, 처리시설에 포함된 빗물정원에서의 오염물질 처리 효율을 높이기 위해 실험실 규모의 인공강우를 이용한 다양한 여재 구성 오염물질(TN, TP, CODcr) 제거율 실험을 실시하였다. 이를 통해 제거효율이 가장 높은 피트머스(Peatmoss)와 자갈, 모래를 구성된 빗물정원을 시범유역에 설치하여 오염물질 제거효율을 측정하였다. 2015년 6월 ~ 7월까지 4회의 실제 강우에 대한 강우사상별 시간별, 강우사상별, 농도별 오염물질 제거율을 분석 한 결과 강우강도가 높거나 강우량이 커질수록 고농도의 오염물질이 빗물처리시설 내 빗물정원으로 유입되었으며, 분석 결과 오염물질의 제거율은 저농도 일 때 보다 고농도 일 때 더 높은 것으로 나타났다. 대규모의 빗물처리시설을 설치하기 어려운 도심지에서, 위와 같은 소규모 시설을 효과적으로 활용 한다면, 도시 유역에서 강우시 발생하는 초기세척효과에 의한 비점오염 형태의 오염물질 유입을 차단해 오염물질 부하를 저감하는데 효과적으로 활용 될 수 있을 것으로 판단되며, 나아가 도서 지역내 용수공급을 위한 소규모 재이용 시설로도 활용 가치가 있을 것으로 판단된다.

목편살수여상조를 이용한 축산뇨오수 처리와 목편여재의 물성 및 부착미생물 특성 (Treatment of Animal Wastewater Using Woodchip Trickling Filter System and Physical and Microbial Characteristics of Wood Chip Media)

  • 류종원
    • 한국축산시설환경학회지
    • /
    • 제17권2호
    • /
    • pp.71-80
    • /
    • 2011
  • 본 연구는 pilot 목편칩 살수여상 공정을 운전하면서 저농도 축산뇨오수 처리시에 오수 처리 특성과 부착 미생물의 특성에 관하여 연구하였다. 목편 살수여상 처리 효율과 목편담체의 부착미생물을 분석한 결과는 다음과 같다. 1. 목편담체는 표면구조가 거칠고 여러 형태의 공극을 볼 수 있었고, 목편압축강도는 섬유방향으로 기건상태에서 34.8 N/$mm^2$ 이었고, 비표면적은 0.4123 $m^2$/g, 세공용적은 0.0947 $cm^3$/g 이었다. 2. 목편담체의 단위면적당 부착미생물량은 1.67~5.43 mg/$cm^3$의 분포를 보였고, 제1 목편 살수여상조에서 평균 4,01 mg/$cm^3$, 제2 목편 살수여상조에서 평균 5.05 mg/$cm^3$로 조사되었다. 부착미생물의 건조밀도는 제1 목편 살수여상조에서 평균 0.275 g/$cm^3$, 제2 목편 살수여상조에서 평균 0.245 g/$cm^3$이었다. 목편담체에 부착된 미생물의 생물막 두께는 0.88~4.11 ${\mu}m$의 분포를 이루고, 제1 목편 살수여상조 평균 157 ${\mu}m$, 제2 목편 살수여상조 평균 2.59 ${\mu}m$의 결과를 얻었다. 3. 부착미생물의 균수 측정에서 호기성균은 제1 목편 살수여상조에서 평균 $1.9{\times}10^8$ CFU/ml, 제2 목편 살수여상조에서 평균 $2.6{\times}10^7$ CFU/ml ddjT으며, 혐기성균은 제1 목편 살수여상조에서 평균 $8.5{\times}10^6$ CFU/ml, 제2목편 살수여상조에서 평균 $5.3{\times}10^5$ CFU/ml로 조사되었다. 4. 살수여상 여과수의 $BOD_5$는 원수에서 비교하여 74.5% 제거되었으며 CODcr 제거효율은 51.5%로서 $BOD_5$ 보다 다소 낮았다. T-N 함량은 처리전 844 mg/$\ell$ 에서 살수여상처리 후 325.5 mg/$\ell$ 로 낮아졌다. T-P 함량은 처리전 127.7 mg/$\ell$ 에서 살수여상 처리 후 55.9로 낮아졌다. 질소, 인의 제거효율도 각각 61.4%, 56.2%를 나타내었다.

Pilot-scale 순환여과식 양식장에서 회전원판 반응기의 순환수 처리 및 산소전달 (Water Treatment and Oxygen Transfer by Rotating Biological Contactor in Pilot-Scale Recirculating Aquaculture System)

  • 서근학;김병진;이정훈;김용하;이석희;김성구;조재윤
    • 한국수산과학회지
    • /
    • 제35권5호
    • /
    • pp.469-475
    • /
    • 2002
  • 사육조 용적 2.5m^3인 pilot-scale 순환여과식 양어장에 나일 틸라피아를 $5\%$$7\%$의 사육밀도로 사육하면서 회전원판 반응기의 암모니아성 질소, 아질산성 질소 및 질산성 질소와 같은 무기질소와 유기물 등과 같은 오염물의 처리 능력을 점검하고자 하였으며 회전원판 반응기의 산소 전달 효율에 대해서도 고찰하였다. 총 암모니아성 질소의 제거속도는 사육밀도 $5\%$의 경우 $30\~80 g/m^3$$\cdot$day의 범위에서 변화하여 $39.4g/m^3{\cdot}day$ 정도의 평균 제거속도를 나타내었다. 사육밀도 $7\%$에서는 15일 이전에는 $30\~80g/m^3{\cdot}day$의 범위로 사육밀도 $5\%$와 유사하였으나 그 이후에는 제거속도가 $80\~170g/m^3{\cdot}day$의 범위로 크게 상승하여 평균 제거속도가 $86.0g/m^3{\cdot}day$ 정도로 나타났다. 회전원판 반응기의 평균 총 암모니아성 질소 제거율은 사육밀도 $5\%$의 경우 $24.5\%$였으며 사육밀도 $7\%$의 경우 $16.0\%$로 나타나 $5\%$의 사육밀도에서 더 높은 제거율을 나타내었다. 아질산성 질소의 평균 제거속도와 평균 제거율은 사육밀도 $5\%$$14.6g/m^3{\cdot}day$$8.1\%$ , 사육밀도 $7\%$$8.1g/m^3{\cdot}day$$10.1\%$로 나타났으며 질산성 질소의 평균 제거속도와 평균 제거끌은 사육밀도 $5\%$$-56.6g/m^3{\cdot}day$$-0.74\%$,사육밀도 $7\%$$-142.6g/m^3{\cdot}day$$-0.63\%$로 나타났다. CODcr,의 제거속도는 사육밀도 $5\%$에서는 평균 1,700g/m^3$\cdot$day, 사육밀도 $7\%$에서는 평균 $4,000g/m^3{\cdot}day$의 값을 나타내어 총 암모니아성 질소의 제거 속도에 비해 매우 높은 값을 나타내었으며 평균 $COD_Cr$, 제거율은 각각 14.5, $29.1\%$이었다. 회전원판 반웅기는 질산화와 유기물 제거에 소요되는 용존산소를 자체적으로 수급할 뿐 아니라 순환수에 용존산소를 더 공급하는 폭기시설의 역할을 동시에 수행할 수 있었으며 사육밀도 $5\%$에서의 평균 폭기 속도는 $280g/m^{3}{\cdot}day$, 사육밀도 $7\%$에서는 $255g/m^3{\cdot}day$였다.