• Title/Summary/Keyword: COD loads

Search Result 183, Processing Time 0.019 seconds

A Study on the Inflowing Pollution Load and Material Budgets in Hampyeong Bay (함평만의 유입오염부하량 및 물질수지에 관한 연구)

  • Kim, Jong-Gu;Jang, Hyo-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • In this paper, an analysis of the inflowing pollution load of the rivers in Hampyeong bay showed the average organic matter pollution loads of BOD, COD, and TOC to be 79.7 kg-BOD/day, 144.06 kg-COD/day, and 93.0 kg-TOC/day, respectively. The inflowing organic matter pollution load was the heaviest in Sonbul dike, followed by Jupo bridge and Yangman complex. With regard to season, the load characteristics were outstanding in July, the rainy period in the summer. The average inflowing pollution loads of nutrients were 20.9 kg-DIN/day, 17.1 kg-DIP/day, 148 kg-TN/day, and 37.4 kg-TP/day A comparison of the inflowing nutrients loads for each river showed the load to be the heaviest in Yangman complex, followed by Baegok bridge and Jupo bridge. In the experiment on the material budgets of Hampyeong bridge conducted using a box model, the detention time of fresh water was found to be 52.4 days, with the bay displaying the characteristics of a so dissolved inorganic nitrogen (DIN) in the nutrients material budgets, ${\Delta}DIN$ values were found to be negative, indicating the tendency of consumption and open sea leak by photosynthesis to be higher than the nitrogen that flowed in. As for dissolved inorganic phosphorus (DIP), ${\Delta}DIP$ showed positive values, indicating a tendency for accumulation as the supply through organic matter decomposition, elution load of sediments, and inflowing load of the river turned out to be higher than the consumption by phytoplankton and outflow to open sea.

Current Status of Refractory Dissolved Organic Carbon in the Nakdong River Basin (낙동강유역 난분해성 용존 유기탄소 배출 현황 분석)

  • Lee, Jeonghoon;Kim, Jungsun;Lee, Jae Kwan;Kang, Limseok;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.538-550
    • /
    • 2012
  • This study suggests a general methodology which is designed for assessing RDOC behavior at the catchment scale by coupling properly a series of steam flow and water quality simulation models and actual monitoring data set. The modified TANK model in which a river routing function is incorporated to the conventional one is applied to simulate the long-term daily stream flow data, and the simulated stream flow data is combined with the 7-parameter log-linear model coupled to the minimum variance unbiased estimator to simulate the long-term daily water quality (BOD, COD and TOC) loads. Finally, the regression analysis between the usually monitored water quality data (BOD, COD and TOC) and RDOC is combined with the simulated water quality data to manifest the spatio-temporal variability of RDOC flux behavior at the Korean TMDL catchment scale.

Characteristics of NPS Pollution from a Coal Mining (가행광산 지역의 비점오염물질 유출특성)

  • Seo, Jiyeon;Shin, Minhwan;Won, Chul-hee;Choi, Yong-hun;Jung, Myung-suk;Lim, Kyoung Jae;Choi, Joongdae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.474-481
    • /
    • 2010
  • This study was conducted to describe the characteristics of Non-point source (NPS) Pollution discharge from a coal mining area in Korea. The study areas is located on the Dogye site, Samchuk, Kangwon Province Coal Corporation and the Jangsung site, Taebaek, Kangwon Province Coal Corporation. The monitoring system was installed at a drainage channel and water samples and rainfall events were collected during March 2008 to February 2009. The collected water samples were analyzed with respect to SS, BOD, $COD_{Cr}$, $COD_{Mn}$, T-N, T-P, and TOC, respectively. It was observed that the runoff and water quality were largely influenced by mine drainage. Also a significant relationship was observed from the correlation between flow and water quality, flow and NPS. And estimated Event Mean Concentration (EMC), NPS pollution loads were Dogey coal mine and Taeback coal mine respectively. As the study progresses in the future, runoff and pollution loads will be updated.

Correlation Analysis on the Runoff Pollutants from a Small Plot Unit in an Agricultural Area

  • Kang, Meea;Choi, Byoung-Woo;Lee, Jae-Kwan
    • Environmental Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.191-195
    • /
    • 2010
  • This study was carried out to investigate the important factors relating to runoff and pollutant loads in a plot unit located in an agricultural area. Of the precipitation parameters, such as total precipitation, days since last rainfall (ADD, the rainfall was more than 10mm) and average rainfall intensity on runoff, the strongest effect was obtained due to total precipitation, but the rainfall intensity showed a slightly positive correlation. It was expected that both variables, i.e. total precipitation and rainfall intensity, would lead to the generation of greater runoff. In contrast, runoff was negatively correlated with ADD, which is understandable because more infiltration and less runoff would be expected after a long dry period. The TSS load varied greatly, between 75.6 and $5.18{\times}10^4g$, per event. With the exception of TN, the TSS, BOD, COD and TP loads were affected by runoff. The correlations of these items were proportional to the runoff volume, with correlation coefficients (r) greater than 0.70, which are suitable for use as NPS model data. The TSS load showed very good relationships with organics (BOD & COD) and nutrients (TN & TP), with correlation coefficients greater than 0.79. Therefore, the removal of TSS is a promising factor for protecting water basins.

Water Quality Status of the Unit Watersheds in the Yeongsang / Seomjin River Basin since the Management of Total Maximum Daily Loads (수질오염총량관리제 시행에 따른 영산강.섬진강수계 단위유역의 수질 현황)

  • Park, Jae Hong;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.719-728
    • /
    • 2011
  • The results of investigation on the water quality of the unit watersheds in the Yeongsang/Seomjin River indicate that $BOD_5$, SS, T-P decrease in most of the unit watersheds. However, $COD_{Mn}$ and T-N increase since the Total Maximum Daily Loads (TMDLs). It is thought that $COD_{Mn}$, which is included non-biodegradable matters, is difficult to decrease only using by conventional biological treatment facilities and T-N is affected by non-point source, etc. The results of assessment on 3 years $BOD_5$ indicate that most of the unit watersheds were being improved except Yeongbon A, Seombon C and Yocheon B. In addition, it was found that T-P were also being improved except Yocheon B and Hwangryeong A. Consequently, water qualities of the unit watersheds have been improved in many cases since the TMDLs.

Estimation of Contribution Ratio and Community Sewerage Treatment Efficiency by using Advanced Sewage Treatment in the Basin of Hongcheon-river (홍천강 유역의 하수고도처리를 적용한 마을하수처리 효율 및 기여율 평가)

  • Park, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3570-3576
    • /
    • 2013
  • This paper calculated advanced sewage treatment efficiency and reduction pollution loads to estimation contribution ratio of for community sewerage in Hongcheon-gun County. The A2/O and SBR methods showed overall high treatment efficiency of 95% and 94% respectively, and SS was 80%. On the other hand, T-N and T-P showed relatively low processing efficiency of 56% and 60% respectively, but it was observed that SS showed high 96% in the MBR method. Next, by the result of yearly water change analysis on water quality of Hongcheon River which is the discharge river of community sewerage, it was observed that water quality was greatly deteriorated by COD, T-N and T-P. However, installation and operation of community sewerage showed high pollution load reduction in general water quality item by more than 80%, and in T-N and T-P by 58% and 68% respectively. It is expected that community sewerage will greatly contribute in water quality improvement of Hongcheon River.

Characteristics of Water Quantity and Quality of the Anyangcheon using SWAT Model and Calculation Result of EMC (SWAT 모형과 EMC 산정결과를 이용한 안양천의 수량 및 수질 특성)

  • Chung, Eun-Sung;Lee, Kil Seong;Shin, Mun-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.648-657
    • /
    • 2006
  • Characteristics of water quantity and quality of the Anyangcheon were analyzed through many field measurements and the distributed hydrologic simulation model, Soil and Water Assessment Tool (SWAT). Event mean concentrations (EMCs) and baseflow mean concentrations were calculated from the data and the daily runoff were simulated by SWAT. The runoff was divided into the direct runoff and the baseflow. Using those values and quantity and quality data of release from the wastewater treatment plant (WWPT), unit loads of BOD, COD, SS, $NO_2-N$, $NO_3-N$, $NH_3-N$, and Dis-P were derived. EMCs of BOD and SS were even higher than the baseflow mean concentrations. The total runoff from October to April (7 months) of 2004 was just 13.5%, since the rainfall usually is concentrated in summer season. Futhermore BOD and SS were loaded during the event by 50.9% and 70.9%, respectively and over three quarters of total COD, $NO_2-N$, $NO_3-N$, $NH_3-N$, and Dis-P were flowed into the Anyangcheon during the remaining period. Therefore, the efficiency of WWPT for COD, $NO_2-N$, $NO_3-N$, $NH_3-N$, and Dis-P should be intensified from Oct. to Apr. and the runoff quality management of BOD and SS should be planned during the summer season.

The Characteristics and the Effects of Pollutant Loadings from Nonpoint Sources on Water Quality in Suyeong Bay (수영만 수질에 미치는 비점원 오염부하의 특성과 영향)

  • CHO Eun Il;LEE Suk Mo;PARK Chung-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.279-293
    • /
    • 1995
  • The most obvious and easily recognizable sources of potential water pollution are point sources such as domestic and industrial wastes. But recently, the potential effects of nonpoint sources on water quality have been increased apparently. In order to evaluate the characteristics and the effects of nonpoint sources on water quality, this study was performed in Suyeong Bay from May, 1992 to July, 1992. The depth-averaged 2-dimensional numerical model, which consists of the hydrodynamic model and the diffusion model was applied to simulate the water quality in Suyeong Bay. When flowrate was $65.736m^3/s,$ the concentration of pollutants (COD, TSS and VSS) at Oncheon stream (Sebeong bridge) during second flush were very high as much as 121.4mg/l of COD, 1148.0mg/l of TSS and 262.0mg/1 of VSS. When flowrate was 4.686m^3/s, the concentration of pollutants $(TIN,\;NH_4\;^+-\;N,\;NO_2\;^--N\;and\;PO_4\;^{3-}-P)$ during the first flush were very high as much as 20.306mg/1 of TIN, 14.154mg/1 of $NH_4\;^+-N$, 9.571mg/l of $NO_2\;^--N$ and l.785mg/l of $PO_2\;^{3-}-P$ As results of the hydrodynamic model simulation, the computed maximum velocity of tidal currents in Suyeong Bay was 0.3m/s and their direction was clockwise flow for ebb tide and counter clockwise flow for Hood tide. Four different methods were applied for the diffusion simulation in Suyeong Bay. There were the effects for the water quality due to point loads, annual nonpoint loads and nonpoint loads during the wet weather and the investigation period, respectively. The efforts of annual nonpoint loads and nonpoint loads during the wet weather seem to be slightly deteriorated in comparison with the effects of point loads. However, the bay was significantly polluted by the nonpoint loads during the investigation period. In this case, COD and SS concentrations ranged 2.0-30.0mg/l, 7.0- 200.0mg/l in ebb tide, respectively. From these results, it can be emphasized that the large amount of pollutants caused by nonpoint sources during the wet weather were discharged into the bay, and affected significantly to both the water quality and the marine ecosystem. Therefore, it is necessary to consider the loadings of nonpoint pollutants to plan wastewater treatment plant.

  • PDF

A Simulation on Water quality improvement by the effluent treatment of landbase-seawater culture system in the Kamak bay (육상축양장 배출수 처리에 의한 가막만의 수질개선 시뮬레이션)

  • Kim Dong-Myung;Jang Ju-Hyoung;Cho Hyeon-Seo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.1
    • /
    • pp.44-59
    • /
    • 2003
  • The three-dimensional eco-hydrodynamic model was applied to estimate the effect of water quality improvement by the effluent treatment of landbase-seawater culture system in the Kamak bay The computed residual currents were dominated southward flow at the northern narrow strait and eastward flow and clockwise water circulation at the mouth of the bay, strongly. The mean relative errors of DIP, DIN and COD between the simulated and observed results at 9 stations in the Kamak bay were shown 14.3%, 25.8% and 14.4%, respectively. There were high concentrations of DIP, DIN and COD at the northwestern bay which is influenced by pollution loads. The simulations were performed using an ecosystem model under the conditions of DIP 90%, DIN 80% and COD 60% treatment efficiency by the ozone treatment system of landbase-seawater culture system. As a results of simulation, the improvement effects of DIP, DIN and COD are 34.4~54.0% (average 46.4%), 0.4~25.4%(average 8.4%) and 15.6~29.4%(average 22.7%), respectively. Therefore the area of seawater quality grade I based on COD was extended in the bay.

  • PDF

Analysis of Pollutant Loads and Physical Oceanographic Status at the Developing Region of Deep Sea Water in East Sea, Korea (동해 심층수 개발해역의 오염부하량 해석과 해황변동)

  • Lee, In-Cheol;Kim, Kyung-Hoi;Yoon, Han-Sam
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.340-345
    • /
    • 2003
  • This study, as a basic study for establishing a influence forecasting/estimating model when drain the deep sea water to the ocean after using it, carried out studies as follows; 1) estimating the amount of river discharge and pollutant loads inflowing into the developing region of deep sea water in East Sea, Korea 2) a field observation of tidal current, vertical distribution of water temperature and salinity, and 3-D numerical experiment of tidal current to analysis physical oceanographic status. The amount of river discharge flowing into the study area was estimated about $462.6{times}10^{3}m^{3}/day$ of daily mean in 2002 year. annual mean pollutant load of COD, TN and TP were estimated 7.02 ton-COD/day, 4.06 ton-TN/day and 0.39 ton/day, respectively. Field observation of tidal current results usually show about $20{\sim}40cm/sec$ of current velocity at the surface layer, it indicated a tendency that the current velocity decreases under 20cm/sec as the water depth increases. We could find a stratification within approximately the depth of 30m in field observation area, and the depth increases. We could find a stratification within approximately the depth of 30m in field observation area, and the differences of water temperature and salinity between the surface layer and bottom layer were about $18^{\circ}C$ and 0.8 psu, respectively. On the other hand, we found that there was a definite as the water mass of deep sea water about 34 psu of salinity.

  • PDF