• Title/Summary/Keyword: COD$NH_3-N$

Search Result 265, Processing Time 0.027 seconds

Sewage Treatment Using Water Hyacinth (Eichhornia crassipes) and Watercress (Oenanthe Javanica) (부레옥잠과 미나리를 이용한 연속식 하수처리에서 COD, N 및 P의 제거)

  • Park, Jin-Sick
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • This study was carried out to investigate sewage treatment efficiencies using water hyacinth (Eichhornia crassipes) and watercress (Oenanthe Javanica). In the hyacinth system about 30% of COD introduced was removed during 2 days of hydraulic retention time, and about 30$\sim$50% of COD was removed in the watercress system during 1.2$\sim$2 days of hydraulic retention time. Therefore, COD loading of $76\sim170$ kg $COD/ha{\cdot}day$ was removed during 2$\sim$3 days of hydraulic retention time at the 0.18 $m^2$ area in the water hyacinth-watercress continuous system. Also 40$\sim$50% of N and P in the sewage were removed in the tested water hyacinth-watercress system Although COD, N and P concentrations in the final effluent were still higher than the limits of waste discharge, applicability of this waste water treatment system should be further investigated as an alternative method far small scale sewage treatments.

The Study on the Non-Point Pollutants Reduction Using Friendly Bank Protection Anaerobic/Aerobic Contact Filtration Zone (혐기/호기 접촉여과대를 이용한 자연형 하천호안공법의 비점오염 저감 특성 연구)

  • Chang, HyungJoon;Kim, SungDuk
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.1
    • /
    • pp.23-34
    • /
    • 2019
  • It is an urgent issue to manage and reduce non-point pollution sources for improving the water quality of stream and lakes in rural areas. In this study, in order to reduce non-point pollution sources in rural area, Gabion mattresses was proposed to provide protection of riverbanks with anaerobic and aerobic area. The utilization of this was assessed by lab scale model test and pilot plant test. After filling the inside of the gabion mattresses with aggregate, the filtration zone under anaerobic and aerobic conditions was formed to treat the contaminants. In addition, vegetation was deposited on the surfae of the gabion to prevent the inflow of soil and to promote purification by the plant. COD and nitrogen content (T-N, $NH_4{^+}$, -N, $NO_3{^-}N$) were monitored in model and field tests. The lab scale model test showed removal efficiency of 17% of TCOD, 35% of SCOD, 14% of TN, 62% of $NH_4{^+}$, -N, and 33% of $NO_3{^-}$ N. Also, pilot plant test showed removal efficiency of 24% of TCOD, 29% of SCOD, 47% of TN, 50% of $NH_4{^+}-N$, 33% of $NO_3{^-}$, N and 29% of TP.

First-flush Runoff Characteristics of NPS from golf course (골프장에서 발생하는 비점오염원의 초기유출수 특성)

  • Shin, Min-Hwan;Choi, Jae-Wan;Choi, Yong-Hun;Seo, Ji-Yeon;Lee, Jae-Woon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1129-1133
    • /
    • 2010
  • 본 연구에서는 수질오염총량제와 정책제안의 원활하고 합리적인 추진을 위해 토지피복분류체계의 대분류중 초지에 해당하고 중분류 중 골프장에 해당하는 지점을 선정하여 강우에 의해 발생하는 비점오염물질의 유출특성을 분석하였다. 연구기간 동안 총 27번의 강우사상으로 인해 발생하는 강우유출수에 대하여 유량과 수질농도를 측정하였다. 유량측정은 웨어를 통한 수위를 측정하여 유량으로 환산하였고, 수질항목은 $BOD_5$, $COD_{Mn}$, DOC, SS, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P 등 9개 항목을 분석하였다. 분석된 결과를 이용하여 골프장에서 발생하는 비점오염원의 초기세척효과 발생여부를 판단하기 위하여 누적오염부하량/누적유출량 그래프를 도식화하였다. 연구기간동안 발생한 5~82 mm의 강우로 인해 6.6~2,082 $m^3$의 유출이 발생하였다. 발생된 유출수의 농도는 $BOD_5$ 1.8~11.3 mg/L, $COD_{Mn}$ 19.2~51.4 mg/L, DOC 11.0~31.0 mg/L, SS 2.2~57.3 mg/L, T-N 1.545~16.098, T-P 0.230~4.528 mg/L, $NH_3$-N 0.076~5.285 mg/L, $NO_3$-N 0.122~2.905 mg/L, $PO_4$-P 0.005~2.631 mg/L로 나타났다. 초기유출수의 세척효과는 27번의 강우사상동안 SS 항목의 경우 17번, $NO_3$-N 11번, $NH_3$-N 4번 등이 발생하였다. 초기세척효과가 발생한 강우사상은 초기의 오염원 농도가 중 후반 농도보다 농도가 높음을 의미하므로, 골프장에서 발생하는 강우유출수는 초기에 발생하는 오염원에 초점을 두고 처리방안을 모색해야 할 것으로 판단된다. 또한 SS와 질소계열의 농도가 높은 것은 골프장의 잔디관리를 위한 농약이나 제초제 등의 사용과 토양유실이 원인인 것으로 판단되며, 이를 저감하기 위한 적절한 사용방안과 저감대책이 필요할 것으로 판단된다.

  • PDF

Evaluation of Water Quality and Phytoplankton Community Using a Multivariate Analysis in Bukhan River (다변량 통계분석을 이용한 북한강의 수질 및 식물플랑크톤 군집 특성 평가)

  • Kim, Hun Nyun;Youn, Seok Jea;Byeon, Myeong Seop;Yu, Soon Ju;Im, Jong Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • The purpose of this study is to evaluate the water quality and phytoplankton community in Bukhan River which account for 44.4 % of the total inflow into Lake Paldang, using multivariate statistical techniques (i.e., correlation analysis, principal component analysis (PCA)/factor analysis (FA)). Water samples were collected from March to November 2015 and the following parameters measured; water temperature, pH, DO, EC, SS, BOD, Chl-a, COD, TN, $NO_3-N$, $NH_3-N$, TP, DTP, $PO_4-P$, and phytoplankton community. The water quality of the main stream and the tributaries were not significantly different apart from the relatively high concentration of BOD, COD and nutrients recorded in MH. The highest cell density of Stephanodiscus hantzschii and Merismopedia glauca dominated phytoplankton was observed in PD. Based on the correlation analysis, total phytoplankton and cyanophyceae were highly correlated with BOD, COD and nutrients. PCA/FA resulted in four main factors accounting for 82.240 % of the total variance in the water quality dataset. The group of component 1 (TN, DTN, DO, $NO_3-N$, water temperature) and component 2 ($PO_4-P$, T-P, DTP, SS) were classified as nutrient element factor whereas component 3 (Chl-a, COD, BOD, $NH_3-N$, pH) was related to organic substances. Hence, the identification of the main potential environmental pollution factors in Bukhan River will help policy makers make better and more informed decisions on how to improve the water quality.

Bacterial Degradation of Monoethanolamine (생물학적 방법에 의한 Monoethanolamine의 분해 연구)

  • Hyun, Jun-Taek;Rhee, In-Hyoung;Kwon, Sung-Hyun;Kim, Dong-Jin;Cho, Dae-Chul
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.157-161
    • /
    • 2007
  • This study is to investigate the biological degradation and the characteristics of MEA, a pH regulator to be put in the cooling water circulation system for power plants, loading to elevate concentrations of COD and N when eluted into the water environment. MEA, $NH_4^+$ and CODcr were monitored in flask cultures and in a batch aerator. MEA was found to be biologically degradable, producing substantial amount of ammonia (max. 78.1%) in a form of $NH_4^+$ and other carboneous intermediates. The degradation reaction rates were similar one another over all MEA concentrations tested as the activated sludge (microbial consortium) was acclimated to MEA with the gradual and stepwise increase in MEA input into the batch aerator. Also, MLVSS kept increasing with increasing MEA input. The COD-based degradation reaction order was determined to be 1.

A Study on Model Based Optimum Design of Oxidation Ditch in Sewage Treatment (산화구 하수처리공정의 최적설계에 관한 기초연구)

  • Dho, Hyonseung
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.25-34
    • /
    • 2019
  • The efficiency of sewage treatment was analyzed by statistical method based on the water quality and operation data of the sewage treatment plant applying the oxidation method. The obtained water quality data were pH, temperature, BOD, SS, T-N, ${NH_4}^+-N$, and T-P of influent and discharge water. Data analysis was performed by correlation analysis, ANOVA analysis, and cluster analysis. As a result of the statistical analysis, the influent flow rate in the sewage treatment plant was the highest in summer. The average inflow flow rate was $3.000m^3/s$. According to Box plot results, COD, and T-P concentrations of effluents were not significantly different from season to season. The Pearson correlation analysis showed strong positive correlation between BOD, COD, T-N, and T-P in influent flow. Seasonal BOD and T-N concentrations were highest in winter and COD and T-P in seasonal influences. BOD showed a strong negative correlation with the water temperature, but showed a positive correlation with other operating factors such as HRT, SRT and C/N. The higher the influent temperature, the lower the BOD concentration. Therefore, retention time was shortened and BOD treatment efficiency was lowered. It was found that T-N had a higher retention time and a higher concentration than DO concentration. On the other hand, T-P did not show a significant correlation with operating factors.

Effects of Seed Sources and Concentration of Ammonia on Anaerobic Digestion (혐기성 소화에 대한 식종원 및 암모니아 농도의 영향)

  • Kim, Yang-Ji;Kim, Sung-Il;Shin, Bum-Shic;Ahn, Ki-Sup;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • The seeding sources and concentration of ammonia on anaerobic digestion were investigated by batch culture bioreactors. The sources of seeding on anaerobic digestion were from swine wastewater collection pit of a hog raising farm and from anaerobic digestion sludge of a municipal sewage treatment plant. The inhibition of ammonia on anaerobic microorganisms was initiated at ammonia concentration of $1,500\;mgNH_4-N/L$ and it's effect was increased by increased by increasing ammonia concentration up to $3,500\;mgNH_4-N/L$ regardless the sources of seeding as evidenced by decreases in COD removal efficiencies and biogas yields. The inhibition occurred to not only methanogens but also acidogens since the concentration of volatile fatty acids was maintained at 50 mg/L The COD removal efficiency and biogas yield were Maintained constantly while increasing ammonia concentration up to $3,500\;mgNH_4-N/L$ when swine wastewater collection pit was used as a seeding; however, those were decreased while increasing ammonia concentration when anaerobic digestion sludge was used as a seeding. The results indicate that the seeding acclimated to high concentrations of ammonia for long time was easy in adaptation to high ammonia concentration and less subjective to ammonia inhibitory effects.

A Study on the Water Pollution of the Wonju Stream (原州川의 水質汚染에 관한 調査硏究)

  • Park, Byoung Youn;Ra, Kyu Hwan;Ok, Chi Sang
    • Journal of Environmental Health Sciences
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 1985
  • Urban sewage and stream water in Wonju city were examined and the results were as follows: The average water quality of Wonju stream was flow 52.8m$^3$/min, BOD 21.14ppm, COD 7.06 ppm, SS 212.4ppm, Cl$^-$ 23.14ppm, O-Phosphate 1.08ppm, NH$_3$-N 1.08ppm, NO$_2$-N 2.63ppm and pH 7.48 respectively. The average water quality of urban sewage was flow 2.76m$^3$/min, BOD 112.7ppm, COD 33.6ppm, SS 374.4ppm, Cl$^-$ 46.2ppm, O-Phosphate 1.56ppm, NH$_3$-N 5.96ppm and NO$_2$-N 3.28 ppm respectively. The quality of stream water showed was 4th grade area according to environmental water quality standard. The survey showed k$_1$ 0.11day$^{-1}$, k$_2$ 0.29day$^{-1}$ and the self- purification coefficient 2.5 in average.. In calculating oxygen variation in water by Streeter-Phelp's equation the zero station exhibited in down stream.

  • PDF

Isolation and Identification of Marine Bacteria with High Removal Efficiencies for Nitrogen-Phosphate In Gwangyang bay (광양만 해역에서의 고효율 질소-인 제거 해양박테리아 탐색 및 분리)

  • Lee, Gun-Sup;Moh, Sang-Hyun;Chung, Young-Jae;Kim, So-Jung;Kim, Young-Jun;Lee, Sang-Seob;Lee, Taek-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3267-3274
    • /
    • 2012
  • 371 strains of marine bacteria were isolated from Gwangyang bay in Korea. The dominant species were identified as Pseudomonas aeruginosa, Aeromonas hydrophila, P. fluorescens, P. paucimobilis, Chryseomonas luteola and P. vescularis. To screen marine bacteria capable of removing nutrients and organics, marine bacteria was inoculated in 10 mL of marine broth 2216 (DIFCO) with $NH_3-N$ (100 mg/L), ${NO_3}^{-}-N$ (100 mg/L), and ${PO_4}^{-3}-P$ (10 mg/L) with 1.0% (v/v), and incubated for 12 h. Results from the screening test, showed that the removal efficiencies for $COD_{Cr}$, ammonia niterogen, nitrate nitrogen, and phosphate were over 25% for 16 strains, 15% for 9 strains, 50% for 63 strains, and 15% for 80 strains, respectively. Aeromonas hydrophila, Chryseomonas indologenes, Pseudomonas diminuta, Vibrio parahaemolyticus were selected for nutrients removal experiments. For the batch test, 4 species of marine bacteria were inoculated in modified marine broth containing with nutrients($COD_{Cr}$ 250 mg/L, $NH_3-N$ 40 mg/L, ${NO_3}^{-}-N$ 40 mg/L, ${PO_4}^{3-}-P$ 10 mg/L, respectively), incubated for 10 hr and the removal efficiencies were measured.

Combined Treatment of Livestock Wastewater with Sewage Using Phanerochaete chrysosporium PSBL-1 (Phanerochaete chrysosporium PSBL-1을 이용한 축산폐수와 하수의 연계처리)

  • Lee, Soon-Young;Cho, Hong-Sik;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.286-291
    • /
    • 2006
  • We studied possibility of mixing treatment of livestock wastewater and sewage using Phanerochaete chrysosporium PSBL-1. Our study showed that 97.6% of SS and 95% of T-P removal efficiency was achieved when 2 mL BF02(a coagulant) and 100 mL C-210EL(a cationic polymer) were added to the mixture(2:1, v/v) of livestock wastewater and sewage. We studied treatment characteristic of Phanerochaete chrysosporium PSBL-1, after were mixed pretreated wastewater and sewage by dillution ten times about livestock wastewater. The removal efficiency of NBDCOD(non-biodegradable COD), $NH_3-N$ and T-N was increased according to increase of pH. That is, T-N concentration of effluent was satisfied 60 mg/L by drain water waterqulity standard of livestock wastewater public treatment facilities with 35 mg/L from a lapse of five days at pH 6.7, 51 mg/L from a lapse of three days at pH 8 and 33 mg/L from a lapse of one day at pH 10. Moreover $COD_{Mn}$ concentration of effluent was satisfied 40 mg/L by drain water waterqulity standard of livestock wastewater public treatment facilities after a laps of one day at all pH. Organics and nitrogen concentrations of effluent were higher case with addition of V.A.(veratryl alcohol) than case without addition of V.A.(veratryl alcohol). $COD_{Mn}$ concentration of effluent satisfied drain water qulity standard of livestock wastewater public treatment facilities from a lapse of one day, when C/N rate(3:1) of influent was not controled. T-N satisfied that from a lapse of two days, when C/N rate was controled with $4{\sim}6$.