• Title/Summary/Keyword: COBRA

Search Result 83, Processing Time 0.035 seconds

How about IRMA Curve (IRMA 법 Curve에 관하여)

  • Chang, Hyunyeong;Sin, Sunyoung;Lee, Hyunju;Woo, Jearyong;Lee, Hoyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.

  • PDF

Comparison of the Electromyographic Activity in the Lower Trapezius Muscle According to Four Different Types of Exercises in Healthy Adults

  • Seo, Gyeong Ju;Park, Ji Won;Kwon, Yonghyun
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.2
    • /
    • pp.134-139
    • /
    • 2019
  • Purpose: This study examined the most effective exercise while performing shoulder abduction below ninety degrees. Methods: Thirty two healthy individuals (17 males, 15 females) participated and performed four exercises, 1) Posterior fly, 2) Prone row, 3) Modified prone cobra, and 4) External rotation in the prone position. Surface electromyography (sEMG) was used to measure the electrical activities for the lower, middle and upper fiber of trapezius and serratus anterior. Results: A significant difference in the muscle activities of the upper/middle/lower trapezius and serratus anterior was observed among the three different positions in terms of the PF (posterior fly), PR (prone row), and MPC (modified prone cobra) (p<0.05). In post-hoc analysis, the activities of the lower and upper trapezius were significantly higher than those of the upper trapezius and serratus anterior (p<0.05). In addition, in ERP (external rotation in prone), there was a significant difference in each activity of the muscles. Post-hoc results indicated that the upper trapezius showed greater EMG activity than the other three muscles. Conclusion: External rotation in the prone position revealed the highest activation of the lower trapezius compared to upper trapezius muscle activity. This may be particularly useful in isolating the lower trapezius in cases where excessive scapular elevation is noted. Therefore, the most effective lower trapezius exercise should be performed below ninety degrees of shoulder abduction.

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.

Improvement of crossflow model of MULTID component in MARS-KS with inter-channel mixing model for enhancing analysis performance in rod bundle

  • Yunseok Lee;Taewan Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4357-4366
    • /
    • 2023
  • MARS-KS, a domestic regulatory confirmatory code of Republic of Korea, had been developed by integrating RELAP5/MOD2 and COBRA-TF. The integration of COBRA-TF allowed to extend the capability of MARS-KS, limited to one-dimensional analysis, to multi-dimensional analysis. The use of COBRA-TF was mainly focused on subchannel analyses for simulating multi-dimensional behavior within the reactor core. However, this feature has been remained as a legacy without ongoing maintenance. Meanwhile, MARS-KS also includes its own multidimensional component, namely MULTID, which is also feasible to simulate three-dimensional convection and diffusion. The MULTID is capable of modeling the turbulent diffusion using simple mixing length model. The implementation of the turbulent mixing is of importance for analyzing the reactor core where a disturbing cross-sectional structure of rod bundle makes the flow perturbation and corresponding mixing stronger. In addition, the presence of this turbulent behavior allows the secondary transports with net mass exchange between subchannels. However, a series of assessments performed in previous studies revealed that the turbulence model of the MULTID could not simulate the aforementioned effective mixing occurred in the subchannel-scale problems. This is obvious consequence since the physical models of the MULTID neglect the effect of mass transport and thereby, it cannot model the void drift effect and resulting phasic distribution within a bundle. Thus, in this study, the turbulence mixing model of the MULTID has been improved by means of the inter-channel mixing model, widely utilized in subchannel analysis, in order to extend the application of the MULTID to small-scale problems. A series of assessments has been performed against rod bundle experiments, namely GE 3X3 and PSBT, to evaluate the performance of the introduced mixing model. The assessment results revealed that the application of the inter-channel mixing model allowed to enhance the prediction of the MULTID in subchannel scale problems. In addition, it was indicated that the code could not predict appropriate phasic distribution in the rod bundle without the model. Considering that the proper prediction of the phasic distribution is important when considering pin-based and/or assembly-based expressions of the reactor core, the results of this study clearly indicate that the inter-channel mixing model is required for analyzing the rod bundle, appropriately.

$\b{W}$COBRA/TRAC을 이용한 고리 1호기 대형냉각재 상실사고 해석

  • 이재훈;최동수;박병서;조창석;박진영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.411-416
    • /
    • 1996
  • 최근 웨스팅하우스사가 SECY-83-472에 근거하여 개발한 최적평가방법론인 WCOBRA/TRAC UPI EM을 이용하여 Appendix K, Superbounded, Nominal 계산을 고리 1호기에 대하여 수행하였다. 15%증기발생기 관막음율, 출력 첨두 계수 2.35, 최대 선형 열출력 15.588kw/ft을 사용하여 계산한 결과 Appendix K 최대 피복재 온도는 1941℉로서 KAERI/Siemens가 RTSR 작성시 수행한 해석에 비하여 운전여유도가 증가한 것으로 나타났으며, 그 결과가 SECY 방법론에 합당함을 확인하였다.

  • PDF

천연 독소로부터 세포독성물질의 분리 및 정제

  • 김영식
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.208-208
    • /
    • 1994
  • 코브라과 (Elapidae)에 속하는 뱀에는 극소량으로도 치사시킬수 있는 독을 가지고 있는데 독을 구성하고 있는 물질중 특정한 계열의 단백질이 매우 두드러진 약리학적 활성을 보여줄수 있다. 따라서 본 연구는 독사들의 혈액독소 및 신경독소를 우리나라에서 제일 종류가 많은 위암세포주(SNU-1)에 대해서 세포독성을 검색하고 곤충 및 해양생물의 독소에 대해서도 위암세포주를 이용하여 검색하였다. 검색 결과 king cobra계통인 Ophiophagus hannah의 분획은 SDS-PAGE에서 분자량이 66,000 부근에 나타난 것이 세포독성물질로 추측되며 더욱 정제하여 아미노산 서열을 비교하고 Phospholipase화성을 측정함으로써 세포독성물질의 규명이 가능하리라 생각된다.

  • PDF

사용후핵연료 장기 건식저장시 최대 초기저장 허용온도에 관한 연구

  • 박근일;이후근;변기호;노성기;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.470-475
    • /
    • 1996
  • 사용후핵연료 장기 건식저장시 여러가지 저장조건에서 사용후핵연료 피복관 및 사용후핵연료 ($UO_2$)에 대한 장기 건전성을 종합적으로 평가할 수 있는 SIECO 코드를 개발하였다. 건식저장 시스템은 사용후핵연료를 헬륨 및 공기분위기하에서 TN-24P 건식 저장용기에 장기 저장할 경우로 하였으며 피복관의 최대 표면온도는 COBRA-SFS코드를 사용하여 계산하였고, 열유동 해석결과를 바탕으로 SIECO코드를 이용하여 핵연료 연소도 및 냉각기간, 냉각매체에 따른 최대 건식저장 허용온도를 피복관의 열화 및 $UO_2$ 산화의 관점에서 계산하였다.

  • PDF