• Title/Summary/Keyword: CO tube

Search Result 809, Processing Time 0.032 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Tracheal gas insufflation (TGI) in patients with increased deadspace fraction: the effect and its determining factors (사강호흡율이 증가된 환자에서 기관내 가스주입법(Tracheal Gas Imsufflation)이 가스교환에 미치는 효과와 그 결정인자)

  • Lim, Chae Man;Jung, Bok Hyun;Koh, Youn Suck;Lee, Sang Do;Kim, Woo Sung;Park, Pyung Hwan;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.136-145
    • /
    • 1997
  • Background : Tracheal Gas Insufflation (TGI) is one of the newer ancillary measures in mechanical ventilation employed to enhance carbon dioxide elimination. TGI exerts its effect through reduction of deadspace ventilation, but the factors determining its effect are not well studied yet. Method : The subjects were seven mechanically-ventilated patients ($58.8{\pm}10.6$ yrs) who showed increased physiologic deadspace greater than 60%. After 30 nun of stabilization with 100% oxygen on pressure control ventilation, continuous flow TGI was administered via the insufflation lumen of Hi-Lo Jet Tracheal Tube (Mallincrodt, USA) for 15 min at 3 L/min and 5 L/min each. Results : $PaCO_2$ was decreased ($51.4{\pm}17.6$ at baseline, $49.1{\pm}18.9$ at TGJ 3 L/min $45.0{\pm}14.9$ mm Hg at TGI 5 L/min, p=0.050), and pH was increased ($7.37{\pm}0.12$, $7.38{\pm}0.13$, $7.39{\pm}0.12$, respectively, p=0.037) while mixed expired $CO_2$ ($P_ECO_2$) was not changed significantly from baseline (p=0.336) by TGI. Physiologic deadspace(Vdphy) was decreased ($73.0{\pm}7.9$% at baseline, $69.8{\pm}10.0$% at TGI 3 L/min, and $67.1{\pm}10.1$% at TGI 5 L/min, p=0.015). $AaDO_2$(p=0.147), Vt(p=0.2140), Pmean(p=0.7788) and mean arterial pressure(p=0.4169) were not changed. The correlation between % maximal decrease of Vdphy were r=0.790 with the ratio of baseline Vdana/Vdphy(p=0.035) and r=-0.754 with baseline Vdalv(p=0.050). Conclusion: TGI was effective in reducing $PaCO_2$ and deadspace, and the deadspace-reducing effect was best correlated with baseline anatomic/physiologic deadspace ratio.

  • PDF

Effect of $CH_4$ addition to the $H_2O$ plasma excited by VHF ICP for production of $H_2$ (고주파유도결합에 의해 여기된 물플라즈마로부터 고효율 수소생산을 위한 메탄가스 첨가효과)

  • Kim, Dae-Woon;Choo, Won-Il;Jang, Soo-Ouk;Jung, Yong-Ho;Lee, Bong-Ju;Kim, Young-Ho;Lee, Seung-Heun;Kwon, Sung-Ku
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.442-442
    • /
    • 2008
  • Hydrogen was produced by water plasma excited in very high frequency inductively coupled tube reactor. Mass spectrometry was used to monitor gas phase species at various process conditions. Water dissociation rate depend on the process parameters such as ICP power, flow-rate and pressure. Water dissociation percent in ICP reactor decrease with increase of chamber pressure and $H_2O$ flow rate, while increase with increase of ICP power. In our experimental range, maximum water dissociation rate was 65.5% at the process conditions of 265 mTorr, 68 sccm, and 400 Watt. The effect of $CH_4$ addition to a water plasma on the hydrogen production has been studied in a VHF ICP reactor. With the addition of $CH_4$ gas, $H_2$ production increases to 12% until the $CH_4$ flow rate increases up to 15 sccm. But, with the flow rate of $CH_4$ more than 20 sccm, chamber wall was deposited with carbon film because of deficiency of oxygen in gas phase, hydrogen production rate decreased. The main roles of $CH_4$ gas are to reacts with O forming CO, CHO and $CO_2$ and releasing additional $H_2$ and furthermore to prevent reverse reaction for forming $H_2O$ from $H_2$ and $O_2$. But, $CH_4$ addition has negative effects such as cost increase and $CO_x$ emission, therefore process optimization is required.

  • PDF

Nitrogen-corrected True Metabolizable Energy and Amino Acid Digestibility of Chinese Corn Distillers Dried Grains with Solubles in Adult Cecectomized Roosters

  • Li, F.;Liu, Y.;Yin, R.Q.;Yang, X.J.;Yao, J.H.;Sun, F.F.;Li, G.J.;Liu, Y.R.;Sun, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.6
    • /
    • pp.838-844
    • /
    • 2013
  • This study was conducted to evaluate chemical composition, nitrogen-corrected true metabolizable energy (TMEn) and true amino acids digestibility of corn distillers dried grains with solubles (DDGS) produced in China. Twenty five sources of corn DDGS was collected from 8 provinces of China. A precision-fed rooster assay was used to determine TMEn and amino acids digestibility with 35 adult cecectomized roosters, in which each DDGS sample was tube fed (30 g). The average content of ash, crude protein, total amino acid, ether extract, crude fiber and neutral detergent fiber were 4.81, 27.91, 22.51, 15.22, 6.35 and 37.58%, respectively. TMEn of DDGS ranged from 1,779 to 3,071 kcal/kg and averaged 2,517 kcal/kg. Coefficient of variation for non-amino acid crude protein, ether extract, crude fiber and TMEn were 55.0, 15.7, 15.9 and 17.1%, respectively. The average true amino acid digestibility was 77.32%. Stepwise regression analysis obtained the following equation: TMEn, kcal/kg = -2,995.6+0.88${\times}$gross energy+$49.63{\times}a^*$ (BIC = 248.8; RMSE = 190.8; p<0.01). Removing gross energy from the model obtained the following equation: TMEn, kcal/kg = 57.88${\times}$ether extracts+$87.62{\times}a^*$ (BIC = 254.3, RMSE = 223.5; p<0.01). No correlation was found between color scores and lysine true digestibility (p>0.05). These results suggest that corn DDGS produced in China has a large variation in chemical composition, and gross energy and $a^*$ value can be used to generate TMEn predict equation.

The study on the quality characteristics factor of medium-sized orbit scroll (중형 선회 스크롤의 품질 특성 인자에 대한 연구)

  • Kim, Jae-Gi;Lim, Jeng-Taek;Kang, Soon-Kook;Park, Jong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.718-723
    • /
    • 2016
  • The use of the scroll compressor in the air conditioning of medium-sized vehicles has increased because of its low torque fluctuation, high energy efficiency and low noise. In addition, the main components of the compressor have been changed from steel to aluminum to reduce its weight, following studies on the constituent materials. The processing precision of the fixed scroll and orbiting involute scroll wrap of the scroll compressor must be below $10{\mu}m$. To ensure this, the surface roughness and contour tolerance are measured. To improve the hardness of the orbiting scrolls using aluminum subjected to anodizing treatment and as the base material, we used a sealing treatment and measured the resulting characteristics. The aluminum materials were made of an Al-Mg-Cu based alloy including small amounts of Ni, Fe, and Zn. The surface roughness was less than $3{\mu}m$ and the processing accuracy was within $10{\mu}m$. Also, the hardness of the nanodiamonds with CNTs used in the sealing treatment was more than 450. This was found to improve the hardness of the material by 50% or more compared to the water sealing treatment and there was little difference between the use of carbon nanotubes and nanodiamonds as sealing materials.

Experimental Study on Fretting Wear of Inconel 690 Under High Temperatures and Pressures (고온 고압 환경에서 인코넬 690 재료의 프레팅 마모 특성에 관한 실험적 연구)

  • Lee, Coon-Yeol;Lee, Ju-Suck;Bae, Joon-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.6
    • /
    • pp.637-644
    • /
    • 2012
  • In a nuclear power plant, fretting wear due to impact motion between U-tubes and support structures located in steam generators can cause serious problems. In order to guarantee the reliability of the steam generator, the damage due to fretting wear should be thoroughly investigated. The purpose of this study is to elucidate the fretting wear mechanism qualitatively and quantitatively. Hence, fretting wear simulation is performed for the environments to which the actual steam generators in nuclear power plants are exposed. Initial experimental results are obtained for various experimental parameters, and the effect of the work rate and temperature on fretting wear is evaluated. In water, the wear coefficients for $90^{\circ}C$, $200^{\circ}C$, and $340^{\circ}C$ are found to be $9.051{\times}10^{-16}\;Pa^{-1}$, $3.009{\times}10^{-15}\;Pa^{-1}$, and $2.235{\times}10^{-15}\;Pa^{-1}$, respectively. It is also found that the wear coefficient at room temperature is larger than that at low temperature in water because of the dynamic viscosity of water.

A study on the black core formation of artificial lightweight aggregates at various sintering atmospheres (인공경량골재의 소성조건이 블랙코어에 미치는 영향)

  • Kim, Yoo-Taek;Ryu, Yu-Gwang;Jang, Chang-Sub;Lee, Ki-Gang;Kang, Seung-Gu;Kim, Jung-Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.6
    • /
    • pp.318-323
    • /
    • 2009
  • The lightweight aggregates made of bottom ash (70 wt%) and dredged soil (30 wt%) were prepared to investigate the property differences at various sintering atmospheres. The green aggregates were sintered at $1150^{\circ}C$ and $1200^{\circ}C$ with oxidized, neutralized and reduced atmospheres. The aggregates sintered with oxidized atmosphere showed a clear border between shell and black core area. However, the aggregates sintered with a reduced atmosphere showed only black core area in the entire cross-section of the aggregates. The black core area of the aggregates sintered with a neutralized atmosphere increased with increasing $N_2$ gas flow rates. It was determined that the sintering atmosphere was similar to that of rotary kiln when the CO gas flow was 100 cc/min to make a reduced atmosphere in tube furnace. The water absorption rates of both aggregates from tube furnace with reduced atmosphere and rotary kiln were very similar to each other.

Development of Qualitative Evaluation of Medical Radiation Protective Apron (의료 방사선 방호용 앞치마의 정성적 평가법 개발)

  • Lim, Hui-Gyeom;Kim, Sang-Hyun;Kim, Tae-Hyung;So, Woon Young;Lee, Tae Hui;Kim, Seung Chul;Kim, Jin-Tae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.453-460
    • /
    • 2017
  • This study proposes effective quality control and maintenance method by developing a new qualitative evaluation method of apron for medical radiation protection. As an experimental material, one of 0.45 mm lead and 100 of 0.45 mm Pb aprons were used and irradiated under the conditions of a tube voltage of 75 kVp and a tube current of 12.5 mAs to obtain an image. and using the Image J program, PSNR values were compared and analyzed. The results showed that there were 40 aprons (less than 11dB), 55 aprons (less than 11dB, less than 30dB), and 5 aprons (30dB or more). In addition, the dose showed a normal distribution for the apron, and 5 aprons with PSNR less than 11dB and 30dB or more were selected and divided into 8 zones, and these groups were statistically significant.

A review of analytical method for volatile fatty acids as designated offensive odorants in Korea (악취성 유기지방산 성분의 분석기술)

  • Ahn, Ji-Won;Kim, Yong-Hyun;Kim, Ki-Hyun;Song, Hee-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.91-101
    • /
    • 2012
  • A list of volatile fatty acids (VFA) including propionic acid, butyric acid, isovaleric acid, valeric acid, etc. is well known for offensive odorants. The analysis of odorant VFA is a highly delicate task due to high reactivity and unstable recovery rate. At present, analytical methods of VFA are recommended to include alkali impregnation filter method and alkali absorption method by the malodor prevention law of the Korea Ministry of Environment (KMOE). In this review, a survey has been made to explore various approaches available for the analysis of VFA to include both official methods of the KMOE and others. In light of the unreliability of those established analytical methods, it is highly desirable to develop some substituting methods for VFA. Among such options, one may consider such option as sorbent tube (ST) sampling and cryogenic trapping-thermal desorption technique. Moreover, procedures used for standard preparation, sampling steps, and instrumental detection stage are also evaluated. Application of container sampling (like Tedlar bag) is however not recommendable due to significant (sorptive) loss in sampling and in storage stage. In the detection stage, the use of GC/MS is recommendable to replace GC/FID due to the presence of diverse interfering substances. Thus, it is essential to properly establish the basic quality assurance (QA) for VFA analysis in air.

Cyclic Loading Test for Beam-to-Column Connections of Concrete Encased CFT Column (콘크리트피복충전 각형강관 기둥-보 접합부의 주기하중 실험)

  • Park, Hong Gun;Lee, Ho Jun;Park, Sung Soon;Kim, Sung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.55-68
    • /
    • 2014
  • In this study, the beam-to column connections of concrete-encased-and-filled steel tube columns were tested under cyclic loading. Two specimens using steel beams and two specimens using precast concrete beams were tested. The dimension of the column cross section was $670mm{\pm}670mm$. The beam depths were 488mm and 588mm for the steel beams and 700mm for the precast concrete beams. The longitudinal bar ratios of the precast concrete beams were 1.1% and 1.5%. For the connections to the steel beams, continuity plates were used in the tube columns. For the connections to the PC beams, couplers were used for beam re-bar connections. The test results showed that except for a specimen, deformation capacities of the specimens were greater than 4% rotation angle, which is the requirement for the Special Moment Frame. Particularly, specimens using precast concrete beam showed excellent performances in the strength, deformation, and energy dissipation.