• 제목/요약/키워드: CO poisoning

검색결과 168건 처리시간 0.021초

Lead Tolerance of Noble Metal Catalysts for CO Oxidation

  • Chang, Tu-Won;Sohn, Youn-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권1호
    • /
    • pp.12-15
    • /
    • 1986
  • Lead tolerance of $Pt/Al_2O_3$ catalysts was evaluated for CO oxidation depending on the properties of the alumina supports and base metals added as promoter. Among the four different alumina supports, the support with a large macropore volume (0.45 cc/g) and 5% Ce has shown the best resistence to lead poisoning. Most of the base metals added to the Pt-catalysts were found to be ineffective for improving lead resistence, but boron has shown an excellent lead tolerence, although it decreases the initial catalytic activity.

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF

일산화탄소 중독시 고압산소투여가 8-hydroxydeoxyguanosine 생성에 미치는 영향 (Effects of Hyperoxia on 8-Hydroxydeoxyguanosine Formation in Carbon Monoxide Exposed Rats)

  • 김헌;조수헌;정명희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권1호
    • /
    • pp.84-106
    • /
    • 1994
  • Hyperbaric oxygen (HBO) therapy for carbon monoxide (CO) poisoning eventually inducing the hypoxia-reoxygenation condition, may produce oxygen free radicals, which forms 8-hydroxydeoxyguanosine (8-OH-dG) by attacking C-8 position of deoxyguanosine (dG) in DNA. Effects of oxygen partial pressure or duration of HBO therapy with or without CO poisoning on the tissue 8-OH-dG formation were investigated. Male Sprague-Dawley rats were grouped and exposed to air (control group), 4000 ppm of CO for 10 to 30 minutes (CO only group), air for 30 minutes after 30 minute exposure to 4000 ppm of CO(CO-air exposure group), HBO after 30 minute exposure to 4000 ppm of CO(CO-HBO group), or HBO therapy fo. $10{\sim}120$ minutes(HBO only group). The 8-OH-4G concentrations in the brain and the lung tissues were measured with high performance liquid chromatography and electrochemical detector (ECD). Average concentrations of the 8-OH-dG of each group were statistically compared. In the brain tissues, 8-OH-dG concentrations of the CO only group, the CO-air exposure group, and the CO-HBO group did not significantly differ from those of the control group. Similar insignificance was also found between the CO-HBO group and the HBO only groups. No appreciable dose-response relationship was observed between the 8-OH-dG concentration and the oxygen partial pressure or the duration of HBO. However, the 8-OH-dG concentrations of the 30 minute CO only group were higher than those of the CO-air exposure group (p-value<0.05). In the lung tissues, there were no significant differences between the 8-OH-dG concentrations of the control group and those of the CO only group, the CO-air exposure group, and the CO-HBO group. However, mean 8-OH-dG concentration of the CO-air exposure group was significantly higher than that of the CO only group under the same CO exposure condition(p-value<0.05). With the duration of CO exposure, the 8-OH-dG concentrations of the lung tissues decreased significantly (p-value<0.05). The concentrations of 8-OH-dG in the lung tissues proportionally increased with the duration of HBO, but no such relation was observed with the oxygen partial pressure. These results suggest that the brain may be more resistant to oxygen free radicals as compared with the lungs, and that oxygen toxicity following HBO may be affected by factors other than oxygen free radicals.

  • PDF

급성 일산화탄소 중독환자에서 병원 전 고산소혈증이 장기 신경학적 예후에 미치는 영향 (Associations between Early Hyperoxia and Long Term Neurologic Outcome in Acute Carbon Monoxide Poisoning)

  • 김주찬;전병조;문정미;조용수
    • 대한임상독성학회지
    • /
    • 제18권1호
    • /
    • pp.18-25
    • /
    • 2020
  • Purpose: We studied the impact of arterial oxygen tension (PaO2) on the long term neurologic outcome in patients with acute carbon monoxide poisoning. Methods: The study population included 311 patients who presented to emergency department with acute CO poisoning from January 2015 to January 2018. These patients underwent arterial blood gas testing at the time of presentation. The baseline demographic, clinical, laboratory, and clinical outcome data were recorded. The primary outcome of interest was the long term neurologic status. Results: The normoxia group was significantly older and it had a higher incidence of diffusion weighted MRI abnormality, and this group needed multiple HBO sessions compared to the group with moderate or severe hyperoxia. Also, the incidence of altered mentality at discharge was higher in the normoxia group than that of the moderate hyperoxia group. The incidence of a poor long term neurologic outcome was 11.3%. The incidence of a poor long term neurologic outcome decreased as the PaO2 increased. The PaO2 was significantly lower in patients with a poor long term neurologic outcome than that of the patients with a good outcome 198 (165.2 to 231.1) mmHg in the good outcome group vs. 154 (119-162) mmHg in poor outcome, p<0.001). In multivariate logistic regression analysis, PaO2 was selected as an independent factor of the poor long-term neurologic outcome (OR 0.981 (95% CI: 0.968 to 0.995)) Conclusion: Higher PaO2 was independently associated with a lower incidence of a poor long-term neurologic outcome.

Characterization of Enhanced CO Oxidation Activity by Alumina Supported Platinum Catalyst

  • Jo, Myung-Chan
    • 한국환경과학회지
    • /
    • 제18권10호
    • /
    • pp.1071-1077
    • /
    • 2009
  • A novel pretreatment technique was applied to the conventional Pt/alumina catalyst to prepare for the highly efficient catalyst for the preferential oxidation of carbon monoxide in hydrogen-rich condition. Their performance was investigated by selective CO oxidation reaction. CO conversion with the oxygen-treated Pt/Alumina catalyst increased remarkably especially at the low temperature below $100^{\circ}C$. This result is promising for the normal operation of the proton exchange membrane fuel cell (PEMFC) without CO poisoning of the anode catalyst. XRD analysis results showed that metallic Pt peaks were not observed for the oxygen-treated catalyst. This implies that well dispersed small Pt particles exist on the catalyst. This result was continued by high resolution transmission electron microscopy (HRTEM) analysis. Consequently, it can be concluded that highly dispersed Pt nanoparticles could be prepared by the novel pretreatment technique and thus, CO conversion could be increased considerably especially at the low temperatures below $100^{\circ}C$.

Comparison of CO on Carbon-supported Pt Catalysts Prepared by CO Gas Bubbling and Methanol Dehydrogenation

  • Han, Kee-Sung;Hwang, Ki-Ju;Han, Oc-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2442-2444
    • /
    • 2007
  • CO adsorbates on the surface of Pt supported on carbon catalysts (Pt/C) were investigated by CO stripping voltammetry. Three types of CO adsorbed samples were prepared: by methanol dehydrogenation only (COm), by CO gas bubbling only (COg), and by methanol dehydrogenation followed by CO gas bubbling (COm+g). Our coverage data show that CO gas can be adsorbed on Pt/C catalyst already saturated with CO adsorbates by methanol dehydrogenation. The COm+g sample showed the properties of both COm as well as COg samples in terms of the potential although the CO adsorbed by dehydrogenation was completely exchanged with CO in the electrolyte solution. Therefore, the oxidation pathways of CO on Pt/C were observed to depend on the initial adsorption conditions of CO more strongly than on the CO coverage. Our results imply that an initial CO poisoning condition in fuel cell operation is an important factor to determine the difficulty in removing the adsorbed CO and confirm that the properties of the adsorbed CO do not change even with chemical replacement with CO in different conditions. In addition, our results indicate a low CO surface mobility on the Pt in an electrolyte solution.

Performance evaluation of TEDA impregnated activated carbon under long term operation simulated NPP operating condition

  • Lee, Hyun Chul;Lee, Doo Yong;Kim, Hak Soo;Kim, Cho Rong
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2652-2659
    • /
    • 2020
  • The methyl iodide (CH3I) removal performance of tri-ethylene-di-amine impregnated activated carbon (TEDA-AC) used in the air cleaning unit of nuclear power plants (NPPs) should be maintained at least 99% between 24 month-performance test period. In order for evaluating the effectiveness of TEDA-AC on the removal performance of CH3I in nuclear power plant during the operation of NPPs, the long-term test for up to 15 months was carried out under the simulated operating conditions (e.g., 25 ℃, RH 50%, ppb level poisoning gases injection) at nuclear power plants (NPPs). The TEDA-AC samples were analyzed with the Brunauer-Emmett-Teller (BET) specific surface area and TEDA content as well as CH3I penetration test. It is clearly evident that more than 99% of CH3I removal performance of TEDA-AC was observed in the TEDA-AC samples during 15 months of long-term operation under the simulated NPP operating conditions including the ppb level of organic and oxide form of poisoning gases. BET specific surface area and TEDA content that can affect the CH3I removal performance of TEDA-AC were also maintained as those in new TEDA-AC during 15 months of long-term operation.

Motor and Sensory Peripheral Neuropathy in a Patient Came after Acute Carbon Monoxide Intoxication: a Case Report with Magnetic Resonance Image

  • Lee, Seungmin;Kim, Sang Yoon;Lee, Jee Young;Choi, Min Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2016
  • Carbon monoxide (CO) intoxication is a leading cause of the variable neuropsychiatric impairment. Despite of widely known central nerve system complications after CO intoxication, peripheral neuropathy due to CO poisoning is rare and has been under-recognized. We report interesting case of a 29-year-old male who suffered from motor weakness and sensory abnormalities in his lower extremity following acute CO intoxication. The patient revealed direct and indirect signs of peripheral neuropathy of the left inferior gluteal and sciatic nerve on magnetic resonance imaging.

고분자전해질 연료전지의 성능과 안정성 시험을 위한 단위전지의 시간 경과에 따른 모델링: 일산화탄소 피독현상에 의한 효과 (Time-Dependent Modeling of Performance Degradation for PEMFC Single Cell System to Evaluate the Cell Performance and Durability: Effects of CO Poisoning)

  • 김종식;김필;주지봉;김우영;이종협
    • 청정기술
    • /
    • 제14권1호
    • /
    • pp.61-68
    • /
    • 2008
  • 연료전지기술은 환경적으로 유해한 오염물질을 발생시키지 않으려, 높은 에너지 밀도를 가지는 청정에너지기술이다. 특히 고분자전해질 연료전지(Polymer electrolyte membrane fuel cell, PEMFC)는 넓은 응용분야로 인해 최근 큰 관심을 받고 있으며, 폭넓은 연구가 진행되고 있다. 본 연구에서는 단위전지 내 연료극(anode) 및 공기극(cathode) 촉매 층을 대상으로 고분자전해질연료전지의 운전시간 경과에 대한 성능변화 및 안정성을 예측하는 모델링을 수행하였다 촉매층에서 발생하는 단위전지의 주요한 성능감소 원인으로 연료극에서의 일산화탄소 피독 현상을 고려하였다. 전지의 장기간 운전모델링 결과 연료극에 공급되는 기체 내의 일산화탄소 비율이 클수록 단위전지성능의 안정성이 크게 감소되는 것으로 나타났다. 또한 장기 운전시 공기극의 느린 산소환원반응과 백금의 용해와 소결에 의해 전지의 성능이 감소되는 것으로 나타났다. 이들을 극복하는 방안으로 연료극에 공급되는 수소의 비율을 높이고 공기극의 촉매층 내에 있는 백금양을 높이는 것을 제안하고자 한다.

  • PDF

황화수소 피독이 고분자전해질 연료전지에 미치는 영향과 회복기법 (H2S Poisoning Effect and Recovery Methods of Polymer Electrolyte Membrane Fuel Cell)

  • 천병도;김준범
    • Korean Chemical Engineering Research
    • /
    • 제55권1호
    • /
    • pp.107-114
    • /
    • 2017
  • 고분자전해질 연료전지(PEMFC: polymer electrolyte membrane fuel cell)는 일산화탄소(CO)나 황화수소($H_2S$)가 포함된 연료가 주입될 경우 성능이 저하된다. 일반적으로 멀캅탄 계열의 부취제가 첨가된 탄화수소를 개질하여 생성된 수소에는 미량의 황화수소가 포함되어 있다. 본 연구에서는 황화수소를 수소에 첨가하여 anode에 주입하였을 경우에 연료전지 성능에 미치는 영향을 파악하고, 3가지 다른 회복방법인 순수 수소 주입법, 전위 순환법과 물 순환법을 적용한 경우의 회복률을 비교하여 보았다. PEMFC의 성능은 전기화학적 방법인 polarization curve, electrochemical impedance spectroscopy (EIS)와 cyclic voltammetry (CV)를 사용하여 분석하였다. 피독에 대한 회복방법인 순수 수소 주입법과 전위 순환법을 사용한 경우에는 회복률이 적었고, 물 순환법을 사용한 경우에는 초기에 대비하여 약 95% 이상 성능이 회복된 것을 확인하였다. 직접적으로 피독에 노출된 anode에 물을 흘린 경우의 성능회복률이 높았으며, cathode에 흘린 경우에도 물의 crossover에 의한 효과로 전위 순환법보다 우수한 회복률을 보였다. 이러한 연구결과로부터 황화수소 피독에 대한 회복기법을 구축함으로서 연료전지의 내구성을 향상시킬 수 있고, 불순물이 미량 함유된 저가 수소의 사용을 가능하게 함으로서 연료전지 보급에도 기여할 수 있을 것이다.