Study on the reduction of green house effect gas emission by RORO ship coastal transport of import-export container cargo (RORO선을 이용한 수출입컨테이너화물의 연안운송에 의한 온실가스 배출량 삭감에 관한 연구)

  • Kim S. H.;Koh C. D.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.3
    • /
    • pp.16-25
    • /
    • 2003
  • In this paper, the reduction of green house effect gas CO₂ emission and NOx gas emission by using the RORO ship coastal transport of import-export container cargo was investigated. At first, the domestic CO₂ gas emission and the transportation of import-export container cargo were Investigated. Next, the characteristic of a RORO ship and CO₂ emission standard and NOx emission standard were investigated. And also, the reduction of CO₂ emission and NOx emission by the shift of coastal transport from land transport for the transportation of import-export container cargo between Kyongin area and Pusan Port were calculated. Finally, the change of CO2 and NOx gas emission due to the change of the share of coastal transportation and the load efficiency of RORO ship are investigated. The research results show that the shift of RORO ship coastal transport from land transport was very effective to reduce the CO₂ emission but it was no good to reduce the NOx emission.

  • PDF

Effect of Heat Loss on CO and NOx Emission Characteristics in the Postflame Region of Premixed Flames (예혼합 화염후류에서 열전달이 CO 및 NOx 생성 특성에 미치는 영향)

  • Kim, Jong-Min;Kim, Tae-Hyun;Kum, Sung-Min;Kim,, Se-Won;Jang, Gi-Hyun;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • Strict pollutant regulations of NOx emission and increasing awareness of the environmental damage stimulated interest in research to obtain useful information regarding CO and NOx reductions at the same time. In this study, $CH_4$/air premixed flame was examined numerically to reduce CO and NOx emission level simultaneously in the post-flame region by the heat loss models in which radiative and combined conductive and convective heat losses were included. To reduce the NOx emission, first heat exchanger location was decided near the flame. After first heat exchanger was decided for the optimal NOx emission(about 30 ppm), in order to decide the optimal CO emission(about 30ppm), seocond heat exchanger location was tested and decided for several cases. Finally, the optimal location of heat exchanger for minimal CO and NOx emission simultaneously were determined and suggested.

  • PDF

NOx and CO Emission Characteristics of Premixed Oxidizer-staging Combustor using a Cyclone Flow (싸이클론 유동을 이용한 예혼합 다단연소기의 NOx 및 CO 배출특성)

  • Kim, Jong-Hyun;Lee, Hyun-Yong;Hwang, Cheol-Hong;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.2
    • /
    • pp.7-13
    • /
    • 2008
  • The aim of this work is to identify application of ultra low NOx and CO combustor. To achieve this, we developed the premixed oxidizer-staging combustor using a cyclone flow. Various factors such as equivalence ratio for the combustion condition and swirl type for secondary air injection have been tested experimentally for flame stability and NOx, CO emission characteristics. Before to do this, we had been tested cyclone premixed combustor in advance. it is similar to first combustor of premixed oxidizer-staging combustor. As a result, cyclone premixed flame shows the very high flame stability and low NOx emission. however, it can be identified that there were some problems such as a little high CO emission and thermal resistance of combustor wall. Cyclone premixed oxidizer-staging combustor can resolve those of problems. In our combustor, we can found out optimal condition that the secondary air injection method is swirl type, swirl direction is co-swirl and equivalence ratio of first combustor is 1.3. Quantitatively, we can achieve 10.8 ppm for NOx and 30.2 ppm for CO emissions respectively. Form this result, we can identified that cyclone premixed oxidizer-staging combustor can apply to ultra low NOx and CO combustor.

  • PDF

A Study on Estimation of NOx and CO Emission Factor from Industrial and Commercial LNG Boilers (천연가스 사용 난방 및 산업보일러의 NOx와 CO 배출계수 산정 연구)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Song, Ki-Pong;Kim, Ho-Jung;Jung, Bong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.615-623
    • /
    • 2004
  • This study was conducted for developing the emission factors of nitrogen oxide(NOx) and carbon monoxide (CO) from the combustion boilers burning liquefied natural gas (LNG). These emission factors were compared with those of U.S. EPA and European Environment Agency (EEA). NOx and CO concentration in the flow gas were measured using Kane-May, KM9106 and Thermo Environmental Instruments Inc., 42C-HL. Measurement were conducted at thirty industrial and commercial LNG boilers. Emission factors were calculated on the basis of fuel consumption (kg-pollutant/㎥-fuel burned). NOx concentration at industrial boiler was 14~125 ppm and it was measured as 35~125 ppm at commercial boiler. NOx emission factors of industrial boiler and commercial boiler were 1.84kg/$m^3$ and 2.09kg/$m^3$, respectively. NOx emission factor of commercial boiler was higher than that of industrial boiler. The NOx emission factors estimated in this study were lower than those of U.S. EPA and higher than those of EEA. Average CO emission factor of industrial boiler was 0.65 kg/$m^3$ and at commercial boiler it was 0.70kg/$m^3$, CO emission factor at industrial boiler was lower than that at commercial boiler.

A Study on NOx Emission and the Characteristics of Partially Premixed Flame (부분 예혼합 화염의 NOx 배출과 화염특성에 관한 실험적 연구)

  • Choi, Ju-Seok;Chun, Chul-Kyun
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.156-162
    • /
    • 2001
  • The effects of co-flow and the variation of the equivalence ratio on NOx emission were investigated experimentally for unconfined and confined partially premixed flames. The shape, length, temperature of flames and the concentration of burnt gas were measured. Two types of co-flow (parallel and swirling co-flow) were considered. For unconfined flames, flame with parallel co-flow is the longest and the next is flame without co-flow. Flame with swirl is the shortest. The length of swirling flame increases suddenly under certain value of equivalence ratio. EINOx is diminished by the decrease of equivalence ratio. It is found that the unconfining of flame enhances the emission of NOx. The EINOx of unconfined flame with parallel co-flow is less than that of flame without co-flow.

  • PDF

Emission Characteristics of NOx and CO with Heat Loss Under High Efficiency Combustion Conditions of $CH_4$/Air Air Premixed Flame ($CH_4$/Air 예혼합화염의 고효율 연소조건에서 열손실에 따른 NOx 및 CO 배출특성)

  • Hyun, Seung-Ho;Hwang, Cheol-Hong;Lee, Chang-Eon;Kim, Se-Won;Jang, Gi-Hyun
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Emission characteristics of NOx and CO with heat loss under high efficiency combustion conditions of $CH_4$/Air prmixed flame were examined numerically using detailed-kinetic chemistry. The one-dimensional combustor length was fixed 5cm, and the equivalence ratio was varied from 0.75 to 0.95. To consider the effects of heat loss on NOx and CO formation, the radiative heat loss rate and combined heat loss rate of conductive and convective heat transfer are included. The following conclusions were drawn. In order to reduce the NOx and CO emission level simultaneously, the temperature of product gases must be reduced under 1,800K as soon as possible but kept over 1,300K during the residence time which is needed to converge CO to $CO_2$.

  • PDF

Study on the reduction of $CO_2$ and NOx emission by coastal transport of import-export container cargo (수출입컨테이너화물의 연안운송에 의한 이산화탄소($CO_2$)와 질소산화물(NOx) 배출량 삭감에 관한 연구)

  • Kim S. H.;Coh C. D.;Cho Y. J.;Van S. H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.4
    • /
    • pp.42-50
    • /
    • 2001
  • In this paper, the reduction of CO₂ gas emission and exhaust gas emission by using the shift of coastal transport from land transport for import-export container cargo was proposed. At first, the domestic CO₂ gas emission, exhaust gas emission and the transportation of import-export container cargo are investigated. And also, we investigated the reduction of CO₂ gas emission and exhaust gas emission by the shift of coastal transport from land transport for the transportation of import-export container cargo between Kyongin area and Pusan Port. Finally, the change of NOx gas emission due to the change of the share of coastal transportation and using the 320TEU container ship are investigated. The research results show that the shift of coastal transport from land transport was effective to reduce the CO₂ gas emission and exhaust gas emission.

  • PDF

A Study on Characteristics of Exhaust Emissions from Domestic Used Diesel Engines (國産 디이젤機關의 汚染物質 排出特性에 關한 硏究)

  • 趙康來;金良均;董宗仁;嚴明道
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.83-92
    • /
    • 1985
  • In odrder to survey the emission level of air pollutants from diesel vehicles, was measured CO, HC, NOx and smoke of 4 types of domestic-use diesel engines under various conditions. The emission of CO, HC and NOx tested by 6-Mode test method and smoke emission by full load test met the permissible vehicle emission standard. Pollutant emission rates of diesel engines were different according to engine operating conditions, that is, engine load and engine speed. Generally, CO and HC was emitted more at low load and NOx at high load but the trend was quite different by the type of engines. In exhaust gas, $NO_2$ portion of NOx emission was high, specially at low speed and low load. The correlation equation between CLD(NOx) and NDIR(NO) method of nitrogen of nitrogen oxides analysis was y = 1.10x - 3.48 (y: CLD method) as a result of 6-mode test.

  • PDF

The Study for Designs of Lean-Premixed low NOx Combustor (희박-예혼합 저 NOx 연소기 설계에 대한 연구)

  • Lim, Am-Ho;Kim, Han-Suck;Ann, Kuk-Young;Lee, Sang-Min;Kim, Yong-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.83-88
    • /
    • 2003
  • The concept of lean-premixed combustion in gas turbine combustor operation has become a standard in recent years as an effective means to meet stringent environmental standards on NOx emissions. Various types of air-fuel premixer, which affect greatly NOx emission and stability of lean-premixed low NOx combustor, were investigated experimentally to reduce the NOx emission. One type of the premixers is selected by experiments and applied it to 70kW class lean-premixed gas turbine combustor. The exit temperature and emissions of CO and NOx were measured with equivalence ratios at ambient pressure. From the results, the emissions of CO and NOx were influenced by the type of air-fuel premixer. As the mixing length of air and fuel is longer, the NOx and CO emission were decreased in the primary reaction zone. Compared with of conventional combustor, the lean-premixed low NOx combustor has low NOx emission characteristics.

  • PDF

An Experimental Study on the Combustion Characteristics in Low Emission Multi-Staged Oil Burner (다단연소를 이용한 저 NOx 버너의 연소특성에 관한 연구)

  • An, Guk-Yeong;Kim, Han-Seok;Jo, Eun-Seong
    • 연구논문집
    • /
    • s.27
    • /
    • pp.101-108
    • /
    • 1997
  • The characteristics of combustion and emissions in multi-staged oil burner have been experimentally studied for the various range of equivalence ratios, drop sizes and fuel formulations. Malvern system was used to measure droplet size of fuel. Light fuel oil and light fuel oil doped with pyridine($C_5H _5N$) were used to investigate the effects on fuel NOx emission. The emissions of NO and CO in exhaust gas and the flame temperatures were measured by the gas analyzer and thennocouples. NOx emissions were increased by increasing the excess air ratio (range:$lambda=1.1-1.4$) or decreasing the SMD of droplet in single-staged burner. In comparison with the single-staged burner, the emission of NOx in multi-staged burner was reduced by 50% but CO emission was slightly increased. It is found that multi-staged burner has a good capability in reducing thermal NOx resulting from the distributed heat release rate and lower flame temperature in fuel-rich and fuel-lean combustion zone. Moreover, the fuel NOx emission of the multi-staged burner is lower than that of single-staged burner, because multi-staged burner has fuel rich zone where fuel N is converted to $N_2$ more than NO. In 3-staged burner, the percentage of each stage combustion air have strong influence on emission characteristics. It is also found that NOx emission can be reduced by decreasing inner and outer air percentage or increasing middle air flow rate and CO emission is vice versa.

  • PDF