• Title/Summary/Keyword: CMOS Image Sensor

Search Result 255, Processing Time 0.023 seconds

Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube (신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브)

  • Cho, Sung-Ho;Kim, Dong-Young;Baek, Kwang-Woo;Lee, Re-Na
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.94-101
    • /
    • 2011
  • Various kinds of medical imaging devices have been studied to develop periapical radiography. However, there are some problems such as high x-ray exposure rate and pains for patients because of the problems caused by intra-oral sensor based radiography system. In this study, a new concept of periapical radiography, intra oral X-ray tube and detector system, is introduced to solve these problems. This system is made up of miniature X-ray tube based on subminiature thermal electron or cold electron, CMOS based detector, and a body including automatic position and system control devices. In order to confirm the possibility of proposed new concept to periapical radiography, miniature x-ray tube from XOFT corporation is used to develop new x-ray system, and the performance evaluation of this system is performed according to collimator. Also, dental images are compared after acquiring both images from existing system versus new concept of system. As a result, new concept of system showed excellent image. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Estimation of Moisture Content in Comminuted Miscanthus based on the Intensity of Reflected Light

  • Cho, Yongjin;Lee, Dong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.296-304
    • /
    • 2015
  • Purpose: The balance between miscanthus production and its cost effectiveness depends greatly on its moisture content during post processing. The objective of this research was to measure the moisture content using a non-destructive and non-contact methodology for in situ applications. Methods: The moisture content of comminuted miscanthus was controlled using a closed chamber, a humidifier, a precision weigher, and a real-time monitoring software developed in this research. A CMOS sensor equipped with $50{\times}$ magnifier lens was used to capture magnified images of the conditioned materials with moisture content level from 5 to 30%. The hypothesis is that when light is incident on the comminuted particles in an inclined manner, higher moisture content results in light being reflected with a higher intensity. Results: A linear regression analysis for an initiative hypothesis based on general histogram analysis yielded insufficient correlations with low significance level (<0.31) for the determination coefficient. A significant relationship (94% confidence level) was determined at level 108 in a reverse accumulative histogram proposed based on a revised hypothesis. A linear regression model with the value at level 108 in the reverse accumulative histogram for a magnified image as the independent variable and the moisture content of comminuted miscanthus as the dependent variable was proposed as the estimation model. The calibrated linear regression model with a slope of 92.054 and an offset of 32.752 yielded 0.94 for the determination coefficient (RMSE = 0.2%). The validation test showed a significant relationship at the 74% confidence level with RMSE 6.4% (n = 36). Conclusions: To compensate the inconsistent significance between calibration and validation, an estimation model robust against various systematic interferences is necessary. The economic efficiency of miscanthus, which is a promising energy resource, can be improved by the real-time measurement of its crucial material properties.

The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images (IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석)

  • Lee, Yong-Hwan;Park, Se-Won;Hong, Jung-Eui
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.205-215
    • /
    • 2011
  • Films are sensitive to ultraviolet rays and in contrast, digital camera sensors are extremely sensitive to infrared rays due to the differences in spectral characteristics. As a result, all digital cameras that use CCD or CMOS are equipped with IR Cut-Off Filter on the overall sensor. Complete block out of infrared rays is ideal, but the actual experiment results showed that infrared rays were not being blocked out completely. Infrared permeability was also different for each camera. Therefore, this study aims to analyze the effect of the minute quantities of infrared rays, which get transmitted due to mechanical properties of IR Cut-Off Filters that are installed on digital cameras, on digital picture images. The results obtained by carrying out a comparative analysis of a UV Filter (infrared transmitting state) and a UV-IR Filter (infrared blocked out state) are as follows. It was confirmed that the minute quantities of infrared rays do affect dynamic range and resolution to some extent, despite the little or no difference in noise and color reproduction.

A Quality-control Experiment Involving an Optical Televiewer Using a Fractured Borehole Model (균열모형시추공을 이용한 광학영상화검층 품질관리 시험)

  • Jeong, Seungho;Shin, Jehyun;Hwang, Seho;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.17-30
    • /
    • 2020
  • An optical televiewer is a geophysical logging device that produces continuous high-resolution full-azimuth images of a borehole wall using a light-emitting-diode and a complementary metal-oxide semiconductor image sensor to provide valuable information on subsurface discontinuities. Recently, borehole imaging logging has been applied in many fields, including ground subsidence monitoring, rock mass integrity evaluation, stress-induced fracture detection, and glacial annual-layer measurements in polar regions. Widely used commercial borehole imaging logging systems typically have limitations depending on equipment specifications, meaning that it is necessary to clearly verify the scope of applications while maintaining appropriate quality control for various borehole conditions. However, it is difficult to directly check the accuracy, implementation, and reliability for outcomes, as images derived from an optical televiewer constitute in situ data. In this study, we designed and constructed a modular fractured borehole model having similar conditions to a borehole environment to report unprecedented results regarding reliable data acquisition and processing. We investigate sonde magnetometer accuracy, color realization, and fracture resolution, and suggest data processing methods to obtain accurate aperture measurements. The experiment involving the fractured borehole model should enhance not only measurement quality but also interpretations of high-resolution and reliable optical imaging logs.

Optical Design of a Subminiature Catadioptric Omnidirectional Optical System with an LED Illumination System for a Capsule Endoscope (LED 조명계를 결합한 캡슐내시경용 초소형 반사굴절식 전방위 광학계의 설계)

  • Moon, Tae Sung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.68-78
    • /
    • 2021
  • A subminiature catadioptric omnidirectional optical system (SCOOS) with 2 mirrors, 6 plastic aspherical lenses, and an illumination system of 6 light emitting diodes, to observe the 360° panoramic image of the inner intestine, is optically designed and evaluated for a capsule endoscope. The total length, overall length, half field of view (HFOV), and F-number of the SCOOS are 14.3 mm, 8.93 mm, 51°~120°, and 3.5, respectively. The optical system has a complementary metal-oxide-semiconductor sensor with 0.1 megapixels, and an illumination system of 6 light-emitting diodes (LEDs) with 0.25 lm to illuminate on the 360° side view of the intestine along the optical axis. As a result, the spatial frequency at the modulation transfer function (MTF) of 0.3, the depth of focus, and the cumulative probability of tolerance at the Nyquist frequency of 44 lp/mm and MTF of 0.3 of the optimized optical system are obtained as 130 lp/mm, -0.097 mm to +0.076 mm, and 90.5%, respectively. Additionally, the simulated illuminance of the LED illumination system at the inner surface of the intestine within HFOV, at a distance of 15.0 mm from the optical axis, is from a minimum of 315 lx to a maximum of 725 lx, which is a sufficient illumination and visibility.