• Title/Summary/Keyword: CM4U

Search Result 494, Processing Time 0.03 seconds

Measurement of the Anticlinic Coupling Coefficient of an Antiferroelectric Liquid Crystal

  • Kang, Dae-Seung;Kimura, Munehiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.487-490
    • /
    • 2002
  • In this paper, we report a novel way to evaluate the anticlinic interlayer coupling coefficient U between smectic layers of an antiferroelectric liquid crystal, by utilizing a small field-induced perturbation of the molecular orientation. U was found to exhibit an unusual "S-shaped" dependence on temperature, with values ranging between $0.4{\times}10^4$ and $0.4{\times}10^{-1}$ erg $cm^{-3}$ over a 10$^{\circ}C$ temperature range below smectic A-smectic $C_A$ phase transition temperature. The results are good agreement with estimates for U based upon the threshold field for the onset of solitary waves, and provide strong supporting the low-field regime for the single Fourier component model.

  • PDF

AN IMMUNOHISTOCHEMICAL STUDY ON ANTI-T LYMPHOCYTE MONOCLONE ANTIBODY AFTER AUTOGENOUS FULL-THICKNESS SKIN GRAFT IN RAT (백서에서 자가 피부이식후 항 T임파구 단일클론항체 분포에 관한 면역조직화학적 연구)

  • Park, Man-Kyu;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.370-380
    • /
    • 1991
  • This article is intended to study histopathological and immunohistochemical response after autogenous full-thickenss skin graft in rat. 12 male Sprague-Dawley rats were used as the experimental animals. A $1Cm{\times}1Cm$ skin(0.7mm diameter) was taken on the right inguinal area of the rat. Another full-thickeness skin graft($1Cm{\times}1Cm$) was taken from the left inguinal area of the rat. And it was transplanted to the right inguinal area of the rat. The left side wound was closed directly. Light microscopic observation was made at the postoperative $1^{\circ}3^{\circ}8^{\circ}16$ day, after the hematoxylin - Eosin staining of the 4u-thick paraffin embedded specimens and the immunoshitochemical staining of the 10u-thick frozen specimens with mouse anti-rat monoclone antibodies and ABC staining kit. The results were as follows. 1. Electromicroscopic studies revealed interstitial tissue bleeding of transplanted autogenous skin. The response was severe in the 1 day group after operation, moederate in 3 day group, mild in 8 day group, and almost resovled in the 16 days group. 2. Electromicrospic studied also revealed a mild monocyte response in the 3 day and 8 day group. A histiocytic infiltrate was observed. There was a mild response in the 3 day group and moderate response in the 8 day group. 3. Immunohistochmically studies revealed a few pan T cells in the 1 day group, mild appearance of pen T cells and cytotoxic T cells in the 3 day group, a moderate infiltrate of pan T cells and helper T cells in the 8 day group, and total resolution of pan T cells in the 16 day group. 4. According to these finding, a strong inflammatory response was observed around transplanted autogenous skin in the 3 & 8 day groups. In the 16 day group this response had resolved histopathologically and immunohistologically.

  • PDF

Evaluation of Rhizofiltration for Uranium Removal with Calculation of the Removal Capacity of Raphanus sativus L. (무순(Raphanus sativus L.)의 제거능 계산에 의한 뿌리여과법의 우라늄 제거 가능성 평가)

  • Han, Yikyeong;Lee, Minhee
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.43-52
    • /
    • 2015
  • The uranium removal capacity of radish sprouts (Raphanus sativus L.) in groundwater was calculated on the basis of the amount of uranium accumulated in the radish sprouts rather than the concentration in solution, of which process was very limited in previous studies. Continuous rhizofiltration clean-up system was designed to investigate the feasibility of radish sprouts, applying for uranium contaminated groundwater (U concentration: 110 μg/L) taken at Bugogdong, Busan. Six acrylic boxes (10 cm × 30 cm × 10 cm) were connected in a direct series for the continuous rhizofiltration system and 200 g of radish sprouts cultivars was placed in each box. The groundwater was flushed through the system for 48 hours at the constant rate of 5 mL/min. The rhizofiltration system was operated in the phytotron, of which conditions were at 25℃ temperature, 70% of relative humidity, 4,000 Lux illumination (16 hours/day) and 600 mg/L of CO2 concentration. While 14.4 L of contaminated groundwater was treated, the uranium removal efficiency of the radish sprouts (1,200 g in wet weight) was 77.2% and their removal capacities ranged at 152.1 μg/g-239.7 μg/g (the average: 210.8 μg/g), suggesting that the radish sprouts belong to the group of hyper-accumulation species. After the experiment, the sum of U amounts accumulated in radish sprouts and remained in groundwater was 1,472.2 μg and the uranium recovery ratio of this rhizofiltration experiment was 92.9%. From the results, it was investigated that the radish sprouts can remove large amounts of uranium from contaminated groundwater in a short time (few days) because the fast growth rate and the high U accumulation adsorption capacity.

Purification of Glucoamylase Produced by Rhizopus oryzae (Rhizopus oryzae가 생산(生産)하는 Glucoamylase의 정제(精製))

  • Hou, Won-Nyong;Chung, Man-Jae
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.322-328
    • /
    • 1984
  • These experiments were conducted to purify the glucoamylase produced by Rhizopus oryzae. Two forms of glucoamylase (GI and GII) from Phizopus oryzae were purified by $(NH_2)_2SO_4$ fractionation, acetone fractionation and successive column chromatography on DEAE-cellulose and CM-cellulose. The specific activities of GI and GII toward soluble starch were 157.6 U/㎎. protein (37.5 fold of crude extract), and 164.7 U/㎎. protein (39.2 fold of curde extract), respectively, and the yields of them were 4.3% and 3.8%, respectively. The two purified enzymes have shown a single band by polyacrylamide disc gel electrophoresis and SDS-polyacrylamide gel electrophoresis. The protein bands of their electrophoresis gel were revealed to have glucoamylase activity by iodine staining and were proved to be glycoprotein by periodic acid Schiff's staining.

  • PDF

The Dose Characteristics of Designed Ir-192 Micro-source for Brachytherapy (근접조사용 Ir-192 마이크로선원의 디자인과 선량 특성)

  • 최태진;김진희
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.81-89
    • /
    • 2003
  • The dose distributions of designed Ir-192 micro-source were investigated by dose computations which were accomplished by employing shape of encapsule material and thickness of the source for self-absorption. The computation dose derived from air-kerma rate (S$_{k}$ ) and dose rate constant (Λ) includes the anisotropy of dose distribution around the source. We got the dose rate constants in a water medium is 1.154 cGy h$^{-1}$ U$^{-1}$ . The size of the source was 0.5 mm in diameter and 3.5 mm in length and it was encapsuled in 1.1 mm$\Phi$${\times}$5.5 mm of stainless steel sealed with 0.3 mm of filter thickness. The tissue dose of reference point at 1.0 cm radial distance of the source axis was delivered 1.154 Uh$^{-1}$ (1.3167${\times}$10$^{-3}$ cGy/mCi-sec) from the S$_{k}$ 4.108U/mCi of Ir-192 source. The filtration effect contributed to air-kerma strength as exponential filtering effect of 86.2% in total attenuation, but self-absorption was 88.4% from radial dose distributions. In particular, the dose attenuations showed a rapid anisotropic distributions as 56% of reference dose along to $\pm$10 degrees from the tip of source axis and 50% for of that to source-cable direction. We persist in use the large diameter of applicator will avoid the dose anisotropy by the filtered attenuation effects along the axis of Ir-192 micro-source.

  • PDF

HARDNESS OF COMPOSITE RESIN CURED BY HIGH INTENSITY HALOGEN LIGHT (고강도 할로겐광으로 중합한 복합레진 수복재의 경도)

  • Park, Jong-Seok;Lee, Kwang-Hee;Kim, Dae-Eup;Kim, Seong-Hyeong;Ahn, Ho-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.471-479
    • /
    • 2001
  • The purpose of this study was to compare the effect of the high intensity halogen light $(850\sim1000mW/cm^2)$ with that of the conventional halogen light $(400mW/cm^2)$ on the hardness of composite resin. Three resin composites (Z-100, 3M, U.S.A. : Tetric Ceram, Vivadent, Liechtenstein; SureFil, Dentsply, U.S.A.) were filed in the stainless steel moulds which were 4mm in diameter and 2, 3, 4, and 5mm in depth, respectively. They were cured under the four different modes : (1) conventional mode, 40 seconds at $400mW/cm^2$; (2) 'ramp' mode, 10 seconds at 100 to $1000mW/cm^2$ plus 10 seconds at $1000mW/cm^2$; (3) 'boost' mode, 10 seconds at $1000mW/cm^2$; and (4) 'standard' mode, 20 seconds at $850mW/cm^2$. The surface hardnesses of the top and the bottom of the resin samples were measured with a microhardness tester (MXT70, Matsuzawa, Japan). The top surface hardness was not significantly different among the curing modes. The bottom surface hardness was generally the highest in the conventional mode and the lowest in the high intensity boost mode. There was no significant difference in the bottom surface hardness between the conventional mode and the high intensity standard mode in 2mm depth. The results suggest that the curing time of the high intensity halogen light $(850mW/cm^2)$ should be at least 20 seconds to produce the equal level of the bottom surface hardness of 2mm resin composite as compared to the hardness produced by the conventional halogen light $(400mW/cm^2)$.

  • PDF

Evaluation of Fire Investigation as the Separation Distances for Several Types of Insulation Panels (단열패널 종류별 이격거리에 따른 화재감식 평가)

  • Kim, Jeong-Hun;Kim, Da-Seul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.403-412
    • /
    • 2021
  • Despite strengthening requirements for fire retardancy and applied buildings of insulation panels, the number of fires and influence of damage have increased. In this study, the thermal effects were evaluated as the separation distances, and three types of EPS panel, glass wool panel, and gypsum board panel were then selected. Temperature sensors on the panels were installed vertically from the ground. The fire source on the lamination layer of lumber was ignited by changes in the separation distances (0 cm, 25 cm, 50 cm) from the panels. The test results suggested that the maximum temperature was 349 ℃ in the EPS panel. The inside/outside shape changes were limited by the height of the low and middle positions until the critical point of a 25 cm separation distance. Furthermore, the combustion marks appeared after 500 s on average, and then the EPS panel with a high fire strength showed a broad "U type" pattern, glass wool panel, and gypsum board panel showed medium or narrow "V type" pattern. Therefore, the acquired data can provide valuable information for evaluating the fire risks and verifying fire investigation from buildings composed of these insulation panels.

Comparison of Quality of CPR between Knee Protection and No Knee Protection in CPR (심폐소생술 시 무릎보호를 한 경우와 하지 않는 경우 간의 심폐소생술의 질 비교)

  • Park, Dae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.733-740
    • /
    • 2010
  • This study was carried out examine the difference in the quality of CPR between knee protection and no knee protection when CPR is performed with mannequin on the floor covered with laminated paper. Subjects of the research were 48 experimental group and 56 control group who were college students in G province and U metropolitan city and completed AHA BLS Provider Course from Apr. 20 to Nov. 15, 2009. This study made knee pad(material: polyester 100%, thickness: 2.5cm, width 16cm${\times}$length 17cm) to protect knee for experimental treatment and measurement of CPR quality was connected with Resusci Anne(Leardal, Norway) mannequin and the results of CPR were recorded with Resusci Anne $Skillreporter^{TM}$(Leardal, Norway). Collected data were analyzed by SPSS/PC+(version 14.0). In conclusion, knee protection in CPR on the floor covered with laminated paper showed higher quality of CPR than that of no knee protection regardless of sex, height and weight.

Studies on the udder characteristics of Korean Holstein cows (국내 젖소의 유방 특성에 관한 연구)

  • Lee, Jeong-chi;Lee, Chung-gil;Lee, Chai-yong
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.143-150
    • /
    • 2004
  • This study was conducted to analyze the relationship between the occurrence of mastitis and the conformation of udders, teats, and teat tips of Holstein cows raised in Korea. Udders, teats, and teat tips were categorized by their conformation and the teat length, teat diameter and the distance from the tip of teat to the ground of 259 cows were measured. The most common shapes of udder, teats and teat tip were milking machine udder (27.4%), U-shaped teats (53.9%) and disk teat tip (53.8%), respectively. Mean teat length and diameters were 4.78 cm and 3.11 cm, respectively. The length and the diameter of front teats were significantly longer and wider than those of rear teats. However, the distance of the tip of teats to the ground was similar between front teats $(50.5{\pm}7.51cm)$ and rear teats $(50.7{\pm}8.83cm)$. The average daily milk yield was 26.4 kg/day, and the highest milk yield was observed from cows with large udder shape and above 4th lactation.

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF