• Title/Summary/Keyword: CM1

Search Result 25,210, Processing Time 0.174 seconds

A Study on the Tannin Treatment of Silk Fabrics(IV) -Change of Properties in Tannin Treated Fabrics- (견의 탄닌처리에 관한 연구(IV) -탄닌처리포의 물성변화-)

  • 설정화;최석철
    • Textile Coloration and Finishing
    • /
    • v.11 no.4
    • /
    • pp.16-23
    • /
    • 1999
  • This study was made to investigate the effects of mimosa tannin and tannic acid on change of properties and photodegradation of silk fabrics according to tannin concentration and irradiation time. The results were as follows. 1. As concentration of tannin increased, thickness, fabric count and stiffness showed no difference. But tensile strength were increased, and elongation were decreased. 2. When concentration of tannin is high, tannin adhered to surface of fabrics. 3. fR absorption bands of untreated silk fabric appeared at $3400cm^{-1},\; 1640cm^{-1},\;1445cm^{-1},\;1235cm^{-1},\;and\;675cm^{-1}$, but those of silk fabric treated with tannic acid appeared at $1710cm^{-1}\;and\;3400cm^{-1}$ by treatment of mimosa tannin, respectively. IR absorption bands of photoirradiated silk fabrics appeared at $3400cm^{-1},\;3280cm^{-1},\;2960cm^{-1},\;2920cm^{-1},\; 1720cm^{ -1},\;1380cm^{-1},\;1280cm^{-1},\;1120cm^{-1},\;and\;1070cm^{-1}$. But those bands were decreased at the silk fabrics treated with mimosa tannin and tannic acid.

  • PDF

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

A study on the basic slacks pattern for middled aged women based on their lower body shape analysis (중년여성의 하반신 체형분류에 따른 슬랙스 원형 제작)

  • 정인향;함옥상
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.40-55
    • /
    • 1997
  • The purpose of this study are to examine the characters of the lower half body shape in the middle aged women and to make slacks patttern on the base of four difference body shapes as follows. The lower half body shapes were classified into 4 types on the basis of their lateral view silhouette, whose characters were summarized as followings. (1) "Type 1" meant the right body shape with the standard protrusion of abdomen and hips. (2) "Type 2" showed the body shape with prominent hips, which had the flat abdominal silhouette and the greatly curved hips silhouette. (3) "Type 3" was the body shape with the prominent abdomen and the flat hips, in which the frontal view silhouette of the abdomen was greatly curved and the rear view silhouette of hips is less curved. (4) "Type 4" was characterized with prominent abdomen and hips. The slaks patterns were based on the lower half body shape characters and resulted in followings. (1) In the type 1, little difference from conventional patterns was seen in experiment pattern, in which the front waist girth was W/4{\times}0.5cm+0.5cm+fold(2.5cm) and the back waist girth W/4+0.5cm-0.5cm+dart(3.5cm). The front hip girth was defined as H/4+2.0cm+0.5cm and the back hip girth as H/4+2.0cm-0.5cm due to its increased ease amount produced by abdominal fat deposition. (2) In the type 2 experimental pattern, the front and back differences of the waist girth and the hip girth were defined as 1.0cm and 2.0cm separately. Accordingly, the front waist girth was W/4+0.5cm+ 1.0cm+fold(2.0cm), the back waist girth W/4+0.5cm-1.0cm+dart(6.5cm), the front hip girth H/4+2.0cm+1.0cm and the back hip girth H/4+2.0cm-1.0cm. (3) In type 3, the front waist girth was set up as W/4+0.5cm+0.5cm+fold (4.5cm) for the increased front fold amount and the back waist girth was W/4+0.5cm+0.5cm+dart(3.0cm). The front hip girth was made as H/4+2.5cm+0.5cm and the back hip girth H/4+2.5cm-0.5cm. (4) In type 4, considered were $\circled1$ the increased fornt fold amount due to the abdonimal protrusion, $\circled2$ the increased back dart amount and the decreased back dart length owing to the hips prominent and $\circled3$ the front and back differences of waist and hip girth for the lateral view silhouette. Therefore the front waist girth was defined as W/4+0.5cm+2.0cm+flod (5.0cm), the back waist girth as W/4+0.5cm-20.cm+dart(4.0cm), the front hip girth as H/4+2.0cm+1.0cm and the back hip girth as H/4+2.0cm-1.0cm. The sensory evaluation of appearance and comfort was appeared more suitable on the experiment pattern than on the conventional pattern.

  • PDF

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

Performance of Direct Seeded Paddy Rice in Dry Soil at Different Seeding Depths (건답직파재배에서 부토심에 따른 벼 품종의 생육가 수량)

  • 이석순;백준호;김태주;홍승범
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.2
    • /
    • pp.174-182
    • /
    • 1993
  • Performance of 3 indica ${\times}$ japonica(Chilseungbyeo, Samgangbyeo, and Gayabyeo), 7 japonica(Yeongsanbyeo, Yeongdeugbyeo, Hwajinbyeo, Palgongbyeo, Seumjinbyeo, Tamjinbyeo, and Milyang 95), and 2 indica(Tebonnet and Lemont) rice varieties was tested at 1, 3, 5, and 7cm seeding depths in a growth chamber and field. In the growth chamber the number of days from seeding to seedling emergence increased as seeding depth increased, while percent germination and emergence and emergence / germination ratio decreased. However, in the field seedling emergence at 1em seeding depth delayed slightly compared to 3cm probably due to lack of soil moisture. The number of seedlings and maximum tillers at 1, 3, and 5cm seeding depths was similar, but it was higher compared to 7cm seeding depth. Yield and yield components were similar among the seeding depths when all the varieties averaged although 1,000-grain weight was slightly higher at 7cm deeding depth compared to others. At 1cm seeding depth the length of mesocotyl of all varieties was similar and ranged 0.1-0.2cm and that of coleptile ranged 0.8-1.1cm. As seeding depth increased up to 7cm Tebonnet which showed the highest percent emergence emerged by elongation of both mesocotyl and coleoptile, while the other varieties emerged largely by elongation of coleoptile.

  • PDF

A study on quantification of α-quartz, cristobalite, kaolinite mixture in respirable dust using by FTIR (FTIR를 이용한 호흡성 분진중 α-quartz, cristobalite, kaolinite 혼합물 정량 분석 연구)

  • Eun Cheol Choi;Seung Ho Lee
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.315-323
    • /
    • 2023
  • This study is to quantify α-quartz, cristobalite and kaolinite using by FTIR in respirable dust generated in the mining workplace. Various minerals in mines can interfere with peaks when quantifying respirable crystalline silica by FTIR. Therefore, for accurate quantification, it is necessary to remove interfering substances or correct the peaks that cause interference. To confirm the peaks occurring in α-quartz, cristobalite and kaolinite, each standard material was diluted with KBr and scanned in the range of 400 cm-1 to 4000 cm-1 using by FTIR. As a result of scanning the analytes, it was decided to use the peaks of 797.66 cm-1 and 695.25 cm-1 for α-quartz, 621.58 cm-1 for cristobalite, and 3696.47 cm-1 for kaolinite. When the above materials are mixed, interference occurs at the peak for quantification, which is corrected by the calculation formula. The analysis of the mixture of α-quartz and cristobalite shows the average bias (%) of 2.64 (corrected) at α-quartz (797.66 cm-1), 5.61 (uncorrected) at α-quartz (695.25 cm-1) and 1.51 (uncorrected) at cristobalite (621.58 cm-1). The analysis of the mixture of α-quartz and kaolinite shows the average bias(%) of 1.79(corrected) at α-quartz (797.66 cm-1), 3.92 (corrected) at α-quartz (695.25 cm-1) and 2.58 (uncorrected) at kaolinite (3696.47 cm-1). The analysis of the mixture of cristobalite and kaolinite shows the average bias (%) of 2.15 (corrected) at cristobalite (621.58 cm-1), 4.32 (uncorrected) at kaolinite (3696.47 cm-1). The analysis of the mixture of αquartz and cristobalite and kaolinite shows the average bias (%) of 1.93(corrected) at α-quartz (797.66 cm-1), 6.47 (corrected) at α-quartz (695.25 cm-1) and 1.77 (corrected) at cristobalite (621.58 cm-1) and 2.61 (uncorrected) at kaolinite (3696.47 cm-1). The experimental results showed that the deviation caused by peak interference by two or three substances could be corrected to less than 6 % of the average deviation. This study showed the possibility of correcting and quantifying when various interfering substances that are difficult to remove are mixed.

An IRS Study on the Adsorption of Carbonmonoxide on Silica Supported Ni-Cu Alloys (실리카 지지 니켈-구리 합금에서 일산화탄소의 흡착에 관한 IRS 연구)

  • Ahn, Jeong-Soo;Yoon, Koo-Sik;Park, Sang-Youn;Park, Sung-Kyun
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.233-243
    • /
    • 2009
  • We have investigated the infrared spectra for CO adsorbed on silica supported nickel(Ni-Si$O_2$), silica supported copper(Cu-Si$O_2$), silica supported nickel-copper alloys(Ni/Cu-Si$O_2$) of several compositions with varying CO pressures(0.2 $torr{\sim}$50 torr) at room temperature and on pumping to vacumn at room temperature within the frequency range of 1500 $cm^{-1}{\sim}2500\;cm^{-1}$. Four bands(2059.6 $cm^{-1},\;{\sim}$2036.5 $cm^{-1},\;{\sim}$ 1868.7 $cm^{-1},\;{\sim}$ 1697.1 $cm^{-1}$) were observed for Ni-Si$O_2$, two bands($\sim$2115.5 $cm^{-1},\;{\sim}$1743.0 $cm^{-1}$) were observed for Cu-Si$O_2$ and five bands(${\sim}2123.2\;cm^{-1}$, 2059.6 $cm^{-1},\;{\sim}$2036.4 $cm^{-1},\;{\sim}$1899.5 $cm^{-1},\;{\sim}$1697.1 $cm^{-1}$) were observed for Ni/Cu-Si$O_2$. These absorption bands correspond with those of the previous reports approximately. The bands below 1800 $cm^{-1}$ were only observed with Ni metal or Ni/Cu alloy crystal plane containing step at room temperature and the ${\sim}1697.1\;cm^{-1}$ bands observed with Ni-Si$O_2$ and Ni/Cu-Si$O_2$ may be ascribed to CO molecule adsorbed on the adsorption sites near step. The bands below 2000 $cm^{-1}$ were rarely observed with Cu metal crystal plane at room temperature and the 1743.0 $cm^{-1}$ bands may be ascribed to CO molecule adsorbed on the adsorption sites near step. The band shifts of adsorbed CO with varing Cu contents from 0 to 0.5 mole fraction at the same CO pressure or at the same pumping time to vacumn were below 21 $cm^{-1}$. and comparatively small than those with other ⅠB metal addition. It may means ligand effect of Cu d electron is small.

Infrared Spectra of Wood Powders from Pinus densiflora, Populus alba x glandulosa and Quercus mongolica (소나무, 현사시나무 및 신갈나무의 적외선(赤外線)스팩트럼)

  • Kong, Young-To
    • Journal of Korean Society of Forest Science
    • /
    • v.52 no.1
    • /
    • pp.31-36
    • /
    • 1981
  • The infrared specta of wood powders have been recorded both in the untreated stste and after treatment through 1%-NaOH extraction(2hrs) and alcohol-benzene mixture extraction. Differences between the spectra of 3 species(Pinus densiflora, Populus alba x glandulosa and Quercus mongolica) can be explained chiefly in terms of theirs chemical compositions through comparisions of the spectra of pure cellulose powders. 1. The peak near $3400cm^{-1}$ from wood powders appeared at $3420cm^{-1}$, which was shifted to left compared with pure cellulose powders. 2. Many new peaks appeared at 2725, 1730, 1660, 1640, 1600, 1510, 1500, 1460, 1385, 1270, 830 and $810cm^{-1}$ etc., which were not appeared in pure cellulose powders. 3. Pinus densiflora spectra of untreated powders showed small peak appeared at $2840cm^{-1}$, which was the most characteristic band. There were peaks at $1240cm^{-1}$ in Populus alba x glandulosa and Quercus mongolica spectra of untreated wood powders. 4. Treated wood powder spectra showed weak or no peaks at near $1730cm^{-1}$ and also at near $2920cm^{-1}$. $2840cm^{-1}$, near $1385-1365cm^{-1}$, near $1235cm^{-1}$ and $1110-1095cm^{-1}$ etc. 5. The Alcohol-benzene extractive spectrum from Pinus densiflora showed many peaks at $3600-2300cm^{-1}$, $3100-2800cm^{-1}$, $1700cm^{-1}$, $1450cm^{-1}$ and $1375cm^{-1}$ etc. The most characteristic band of the extractives appeared at $3100-2900cm^{-1}$.

  • PDF

Optimum Field Size for the Whole Body Stereotactic Radiosurgery (전신 정위 방사선 치료시의 적정 조사면 크기)

  • 이병용;민철기;정원규;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2002
  • Optimum field size for the whole body stereotactic radiosurgery was studied. Dose distributions from the various sizes of targets (diameter 1cm to 7cm, icm interval) were used for this study. Planing scores, expressed as the Target Coverage Index (TCI), were calculated for various target Margin ranged 0cm to 0.5cm. Highest scores were obtained for no Margin to the target size. The target Margin -0.5cm to 0cm to the target showed best TCI the cases of the target size larger than 6cm diameter. No Margin or 0.5cm Margin generated best TCI for less than 2cm cases. Prescription to 80~90% gives best results.

  • PDF

Characteristics of Hardening Behavior of Korean Rhus Lacquer by F.T.-I.R. (F.T.-I.R.에 의한 한국산 옷액의 경화거동 특성)

  • Lee, Phil-Woo;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.10-14
    • /
    • 1990
  • 한국산 옻액의 경화거동을 알아보기 위하여 F.T.-I.R. 분석을 수행하였다. Acetone 추출한 urushiol의 F.T.-I.R. peak는 $3,422cm^{-1}$, $2,928cm^{-1}$, $1,622cm^{-1}$, $1,475cm^{-1}$, $1,281cm^{-1}$, $984cm^{-1}$, $947cm^{-1}$, $735cm^{-1}$이었다. 또한, 옻액의 정시경화거동에서 $1,651cm^{-1}$ peak는 urushiol-quinone이 laccase의 촉매작용에 의하여 산화중합한 후 982와 $947cm^{-1}$의 conjugated diene와 결합해서 dimer 형성을 알 수 있었다.

  • PDF