• Title/Summary/Keyword: CM-wire

Search Result 251, Processing Time 0.028 seconds

Effect of Canopy Reforming on Light Penetration into Crop Community and Yielding in Corn (옥수수 초형교정이 군락 투광성 및 수량성에 미치는 영향)

  • 이호진;조명제;이홍석
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.1
    • /
    • pp.76-83
    • /
    • 1985
  • A hypothesis that artificial reforming of corn canopy could improve solar light penetration and dry matter production was tested in corn fields (var. Suwon 19) with three planting densities; low (60 ${\times}$ 40cm), medium (60 ${\times}$ 24cm) and high (60 ${\times}$ 16cm). Natural canopy was found that leaf orientations were even over all azimuth but somewhat inclined toward north-south direction and leaf angle ranged 38$^{\circ}$ to 71$^{\circ}$ from horizontal surface. Reforming corn canopy included following treatments: 1) natural canopy planted in north-south rows (natural canopy), 2)east-west plane canopy planted in north-south rows (E-W canopy), 3)east-west plane canopy and upright leaves in north-south rows, 4)north-south plane canopy (N-S canopy) in east-west rows. After corn plots were installed with training system by supporting poles and connecting wires, corn leaves were induced to a reforming direction and tied on wire. Average light intensity at the mid-point of plant height showed 5-10% increases in E-W canopy and in E-W canopy plus upright leaves, but a 2-10% decrease in N-S canopy from natural canopy. At yellow ripe stage, total dry wt. was increased in E-W canopy but not in N-S canopy. The E-W canopy produced 3-10% more grain yield than natural canopy. Though E-W canopy plus upright leaves yielded less at low density, it yielded up to 10% more at higher density. The N-S canopy yielded similar to low compared with natural canopy. These results suggests that reforming canopy toward solar incident direction increases light penetration into lower canopy, photosynthetic efficiency and grain yield, especially at high planting density in corn.

  • PDF

Emission test of a domestic fabricated cathode with higher current density

  • Ju, Yeong-Do;Gong, Hyeong-Seop;Kim, Seung-Hwan;Tanwar, Anil;Seok, Yeong-Eun;Lee, Byeong-Jun;Hong, Yong-Jun;Sin, Jin-U;So, Jun-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.205.2-205.2
    • /
    • 2016
  • The emission test a domestic fabricated cathode is conducted using an easy-replaceable-emitter-type test bench. A simple cylindrical button type cathode is dropped vertically into a cathode cup holder. The cathode is heated by a tungsten wire heater located around the cup holder. The cathode temperature is measured by an optical pyrometer. A high voltage pulse power supply gives the anode-cathode gap voltage up to 20 kV with the pulse width of 15 us. The emitted current from the cathode is captured at a faraday cup and is measured using current transformer and oscilloscope. The test bench is installed in the vacuum chamber with easy access door and, therefore, the cathode can be easily replaceable. We confirmed the emission current density of $15A/cm^2$ and $80A/cm^2$ with a domestic fabricated B-type cathode and a Scandate cathode, respectively. The detailed test result for the cathode will be presented.

  • PDF

Wind Profile in Rice Paddy Field (수도 재배 논에서 공기유동 프로파일)

  • 이중용;안은수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.3
    • /
    • pp.221-228
    • /
    • 2001
  • Chemical application, one of the most important crop management processes happened to cause spray drift, that would threaten farmers in field as well as dwellers in rural region. Spray drift was affected by micro-meteorological parameters. A study to evaluate short distance drift characteristics of a boom sprayer in paddy fields has been undergoing. This study is the first step of the research. Main purpose of the was conducted to develop a mean wind profile and to get information on turbulence intensities above and within rice canopy. Wind in rice paddy field were measured at every 10cm from 10 to 180cm above the ground using a 2-dimensional probe and a hot wire anemometer system. Main results were summarized as follows. 1. Mean wind profile was modeled as; Equations. see full-text 2. Roughness length and zero-displacement in rice canopy were analyzed to be respectively 0.04 and 0.7∼0.72 times of the canopy height. The values are smaller comparing to those of other crops because rice canopy is flexible and uniform comparing to other crops. 3. Turbulence intensities (Tl) was greater as close to the ground and became constant at heights greater than 1.5Hc. where Tl’s were 0.4 and 0.15 in horizontal and vertical direction respectively.

  • PDF

Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector (커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석)

  • Kim, Sang-Chul;Kim, Doo Hyun;Kang, Shin Uk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

Development and Application of Measurement System for Clothing Pressure (인체의복압 환경개선을 위한 의복압 측정 System 개발에 관한 연구)

  • Song, Kyung-Hern;Kim, Jeong-Hwa;Park, Sung-Ha
    • Korean Journal of Human Ecology
    • /
    • v.11 no.3
    • /
    • pp.307-319
    • /
    • 2002
  • We studied on the development of clothing pressure measurement system for wear comfort of foundations(girdle, brassiere, all-in-one). Measurements of clothing pressure were made on subjects wearing girdles, brassieres, all-in-ones of several type(material, size) using by CPMS(clothing pressure measurement system: Tech-Storm. Co). Wearing experiments have been carried out using nine women in the twenties and six women in the forties. The results obtained are as follows: 1. The clothing pressure applied by girdle was higher in the hard type than the soft type by $5-10gf/cm^2$, also recorded a high clothing pressure at points of waist band line and thigh lateral. 2. Clothing pressure of brassiere with wire was high at the point of underbust line and shoulder strap. Pressure for 40s showed higher than 20s by $6-7gf/cm^2$. 3. The pressures of abdominal part applied by both of girdle and all-in-one were much greater than those of girdle or all-in-one. 4. We demonstrated the adaptability and conformity of the CPMS by inquiring into the clothing pressure of various foundations.

  • PDF

Assessment of PCBs-containing solid wastes using official wastes test method (폐기물공정시험방법을 이용한 PCBs 함유 고상폐기물의 적용성 평가)

  • Kim, Kyeo-Keun
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study was performed to evaluate the PCBs-containing wastes using official test method. Ninety samples of transformer oil and various solid waste were collected to assess the analytical results. In the analysis of PCBs-containing wastes, the PCBs levels were detected in the range of 7.6 mg/kg to 23.8 mg/kg for transformer oils, $0.02\sim0.54\;{\mu}g/100cm^2$ for plat solid wastes, and 0.01~0.071 mg/kg for amorphous solid waste. In the cupper wire waste of the transformer with oil concentration level of 23 mg/kg, the analytical result exceed PCBs regulation level of 0.04 mg/kg. The new proposed analytical method for PCBs containing waste can be forced to effective management of the wastes.

Clinical Experience of Pectus Excavatum Corrected by Ravitch Method (Ravitch 술식으로 교정한 누두흉 치험)

  • 김하늘루;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.930-934
    • /
    • 1999
  • Background: The purpose of this study is to analyze the clinical results ad operative compatability by Ravitch methods with pectus excavatum. Material and Method: From 1984 to 1997, were performed Ravitch operations in 40 patients of pectus excavatum and analyzed the effects of correction and postoperative complication according to time of operation retrospectively. The group comprised 35 mem and women whose mean age was 8.9$\pm$7.9 years(between 2 to 35 years). All patients had corrected with Ravitch operation or its modified operation. Modified fixations were accomplished with K-wire in 15 patients and internal plate in 2 and the materials were removed 3 months after operation. The result of correction was estimated with the degree of changed distance between inner surface of sternal body and vertebral in 3 months after correction. Result: Postoperative complications were wound disruption in 14 patients. Estimated distances after correction ranged 0.4 cm to 4 cm. The acceptability for chest wall correction was high(6 excellent, 29 good in criteria of Humphreys). Conclusion: We concluded that the benefits of Ravitch operation were a high acceptability of patients and their family, and sufficient correction with no specific complications related operation.

  • PDF

Construction of a Low Magnetic Field Standard System Using a Precision Solenoid (정밀솔레노이드를 사용한 저자장 표준시스템 제작)

  • 박포규;손대락;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.150-155
    • /
    • 1992
  • The low magnetic field standard below 1 mT with resolution of 100 nT has been established for the calibration and testing of low field magnetometers. A precision single layered solenoid, which is made of quartz tube and bare copper wire, was constructed in order to generate a precise magnetic field. To improve the field homogeneity in the solenoid, three-current method was employed. The injected current and injection points on the solenoid were optimized by computer simulation. The magnetic field uncertainty in the solenoid was 0.1 % and 0.01 % in the range of ${\pm}5\;cm$ from the center for a single and three-current methods respectively. We also constructed a testing system for the dynamic properties of low field magnetometers.

  • PDF

Magnetic Resonant Wireless Power Transfer with Rearranged Configurations

  • Kang, Seok Hyon;Jung, Chang Won
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.2
    • /
    • pp.76-85
    • /
    • 2017
  • We investigate the indirect-fed magnetic resonant wireless power transfer (MR-WPT) system for wireless charging for mobile devices by rearranging the loops and coils. Conventional MR-WPT is difficult to apply to consumer electronic products because of the arrangement of the resonators. In addition, there are restrictions for charging using a wireless technology, which depend on the circumstances of the usage scenarios. For practical applications, we analyzed the transfer efficiency of the MR-WPT system with various combinations and positions of resonators. Three rearranged configurations (Out-Out, Out-In, In-In) have been considered and experimentally investigated using hollow pipe loops and wire copper coils. There were four types of loops and two types of coils; each one had a different diameter and thickness. The results of the measurements show that the trends of the transfer efficiencies for the three configurations were similar. A transfer efficiency of 82.5% was achieved at a 35-cm distance between the 60-cm diameter transmitter (Tx) and receiver (Rx) coils.

Esophageal foreign body with esophageal perforation (식도천공을 초래한 식도이물)

  • 장선문;정동규;이가인;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.90.3-90
    • /
    • 1976
  • The authors experienced an unusual case of esophageal foreign body with esophageal perforation. A 8-month-old boy swallowed a long (about 20 cm) thick (about 3mm in diameter) wire, which had a hooked end and the another straight. The hooked end was located at near the first esophageal narrowing with swelling on the left lateral neck and the another end was out of his mouth. As failure of complete removal of the foreign body with esophagoscopy, the hooked end was cut and removed with the lateral incision of the neck and the remainder was removed was removed with esophagoscopy. After removal of the foreign body, nothing was given by mouth and the patient feed through nasogastric tube for about 4 weeks and the perforated esophagus was healed completely without any other complication.

  • PDF