• 제목/요약/키워드: CM System

검색결과 5,227건 처리시간 0.031초

수종 임플랜트 시스템에서의 회전력에 관한 연구 (A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM)

  • 문익훈;정재헌
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

국내 시공책임형 CM 오픈북 정책 현황 분석을 통한 개선방안 (Improvement through Analysis of Current Open Book Policy for the Korean CM at Risk)

  • 박경모;김창덕
    • 한국건설관리학회논문집
    • /
    • 제17권2호
    • /
    • pp.3-11
    • /
    • 2016
  • 건설산업의 변화에 따라 글로벌 수준의 사업관리 기술력과 서비스 역량의 중요성 증대 및 새로운 발주방식의 필요성에 의해 시공책임형 CM방식이 국내 건설산업에 적용되었다. 하지만 시공책임형 CM에 대한 인식부족, 오픈북 정책에 대한 신뢰성 부족 그리고 CM기업의 시공책임형 CM에 대한 기술력 및 관리 능력 부족 등으로 인해 국내 시공책임형 CM 활성화가 어려운 실정이다. 따라서 본 연구에서는 국내 CM기업 중 시공책임형 CM실적이 가장 높은 A기업의 33개 프로젝트를 계약유형, 오픈북 정책 항목, 계약조건에 대한 문제점들을 분석하였다. 그리고 시공책임형 CM에서 오픈북 정책을 정착하기 위한 방안을 구성원 교육 강화를 통한 고객만족도 강화부분, 자금청구 시스템 개선을 통한 추가 현장업무 최소화 부분, 현장 성과평가 방식 개선을 통한 오픈북 정책 정착 유도 방안으로 구분하여 제시하였다. 이러한 개선방안을 통해 시장 주도권 확보, CM서비스 차별화, 발주자 공감대 형성을 통한 신뢰성 확보 그리고 CM의 본질 유지를 통한 공감성 형성이 가능할 것으로 기대한다. 또한 본 연구는 시공책임형 CM에 대한 경쟁력 향상과 차별화 전략에 기여할 수 있을 것으로 기대한다.

호흡동조 방사선치료에 사용되고 있는 RPM (Real-time Position Management) Respiratory Gating System의 호흡변화에 따른 정확성에 대한 고찰 (Consideration of the Accuracy by Variation of Respiration in Real-time Position Management Respiratory Gating System)

  • 나준영;강태영;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.49-55
    • /
    • 2013
  • 목 적: 본원에서 시행하고 있는 호흡동조 방사선치료(Respiratory Gated Radiation Therapy, RGRT)는 RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA)을 이용하여 실시하고 있다. 본 연구는 호흡변화에 따른 방사선치료의 정확성을 분석하고 평가하고자 한다. 대상 및 방법: 움직임을 임의로 조정할 수 있는 구동 팬텀(Motion Phantom)인 QUASAR Programmable Respiratory Motion Phantom (Moudus Medical Device Inc. CANADA)을 이용하였다. 폐암과 간암 환자 50명의 호흡을 분석하여 호흡의 변화를 관찰한 결과를 기준으로 주기 3초, 진폭 1.5 cm인 총 60초간의 기준호흡에서 매번 기저호흡(Baseline)을 기울기를 갖고 점진적으로 내려가는 경우와, 간헐적으로 기준 기저호흡 보다 더 내려가는 경우의 호흡 모양을 만들어 본원에서 사용되고 있는 Phase gating, 보통 30~70% gating 치료 방법과 동일하게 방사선을 조사하였다. 결 과: 점진적으로 매번 기저호흡이 0.01 cm, 0.03 cm, 0.05 cm씩 내려가는 호흡의 경우 모든 조건에서 방사선이 조사되었다. 간헐적으로 기저호흡이 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm 내려가는 경우도 모든 조건에서 방사선이 조사되어 RPM Respiratory Gating System에서 Phase gating 방식은 기저호흡 변화에 대하여 방사선이 모두 조사되었다. 결 론: 최적의 방사선치료를 위해 종양의 움직임을 고려하여 시행하는 호흡동조 방사선치료에서 RPM Respiratory Gating System의 Phase gating 방식은 본 연구에서와 같이 기저호흡의 변화가 호흡동조에 정확히 반영되지 않음을 알 수 있었다. 이에 호흡동조 방사선치료에는 무엇보다 환자의 호흡 관찰이 중요하다고 사료되며 호흡의 변화가 관찰되었다면 즉시 방사선치료를 멈추고 호흡을 관찰한 후 변화된 호흡상태에서 투시를 시행하여 치료부위를 다시 확인한 후에 치료를 재개하여야 한다고 사료된다.

  • PDF

Verification of Normalized Confidence Measure Using n-Phone Based Statistics

  • Kim, Byoung-Don;Kim, Jin-Young;Na, Seung-You;Choi, Seung-Ho
    • 음성과학
    • /
    • 제12권1호
    • /
    • pp.123-134
    • /
    • 2005
  • Confidence measure (CM) is used for the rejection of mis-recognized words in an automatic speech recognition (ASR) system. Rahim, Lee, Juang and Cho's confidence measure (RLJC-CM) is one of the widely-used CMs [1]. The RLJC-CM is calculated by averaging phone-level CMs. An extension of the RLJC-CM was achieved by Kim et al [2]. They devised the normalized CM (NCM), which is a statistically normalized version of the RLJC-CM by using the tri-phone based CM normalization. In this paper we verify the NCM by generalizing tri-phone to n-phone unit. To apply various units for the normalization, mono-phone, tri-phone, quin-phone and $\infty$-phone are tested. By the experiments in the domain of the isolated word recognition we show that tri-phone based normalization is sufficient enough to enhance the rejection performance of the ASR system. Also we explain the NCM in regard to two class pattern classification problems.

  • PDF

발주자 유형별 CM산업 수주실적 분석 : 1997~2013년 실적자료 (Analysis of the CM Industry Based on Owner Type : 1997 to 2013 Statistics)

  • 하지원;강승희;정영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.209-210
    • /
    • 2015
  • Since CM policies established in 1996, contracts of CM services are continuously increasing over the past years. As constant improvement of positive awareness about public/private owners and CM capabilities of domestic construction companies, a number of efforts were being made to acquire competitiveness of domestic and overseas CM market. However, there has been lack of quantitative and comprehensive research to investigate CM firms. The purpose of this research is to statistically analyze total of 2,983 CM service contracts over the past 16 years published in KISCON (Knowledge Information System of Construction Industry) in order to examine CM owner type.

  • PDF

통신시스템의 데이터 전송선로에 대한 연구 (A Study on the Data Transmission line of communication system)

  • 김석환;이규정;허창우
    • 한국정보통신학회논문지
    • /
    • 제9권6호
    • /
    • pp.1277-1281
    • /
    • 2005
  • 현재 통신시스템에서는 FPGA를 사용하여 여러 가지 로직을 구현하고 있다. 본 논문에서는 데이터 전달 특성을 분석하고 신호의 노이즈와 데이터 손실을 방지하기 위하여 10층의 PCB(Printed Circuit Board)를 만들었다. FPGA에 클럭과 64bit의 데이터를 동기 시켜 전송선로의 길이의 변화와 입력된 클럭의 주파수 변화에 따른 최대 안정된 데이터 전달속도와 전송선로의 길이를 알아보았다. 제작된 PCB보드에서 FPGA의 출력 핀에서 출력포트 사이의 전송선로 길이는 13cm이며 확장된 테스트용 전송선로 보드의 길이는 30cm, 60cm, 120cm이다. 그러므로 전송선로의 길이를 13cm, 43cm, 73cm, 133cm간격으로 측정하였으며, 데이터 전송특성에 대한 클럭 주파수는 100MHz, 50MHz, 100MHz, 125MHz, 150MHz로 나누어 측정하였다. 데이터 전달 특성에서 125Mbps까지는 불가능 하지만 전송선로의 길이가 30cm일 경우 최대 100Mbps까지 안정하게 데이터를 전달할 수 있었다.

Effects on Rice Growth of System of Rice Intensification under No-till Paddy in Korea

  • Meas, Vannak;Shon, Daniel;Lee, Young-Han
    • 한국토양비료학회지
    • /
    • 제44권1호
    • /
    • pp.91-97
    • /
    • 2011
  • The objectives of this research were to investigate the system of rice intensification (SRI) on early growth, grain yield, and yield components under Chinese milk vetch residue-mulched no-tillage cropping systems at silt loam soil. The field was prepared as a split-plot design with three replications, main plots consisted of Dongjinbyeo, and Sobibyeo as a cultivar, and subplots consisted of $10{\times}10$ cm, $20{\times}20$ cm, and $30{\times}30$ cm as a planting density. Weed infestation during rice growing season was more severe in wider planting density $30{\times}30$ at 35 days after transplanting (DAT), and $20{\times}20$ cm at 95 DAT in both Sobibyeo and Dongjinbyeo. The maximum plant height was recorded in Sobibyeo compared with Dongjinbyeo, $10{\times}10$ cm and $20{\times}20$ cm planting density compared with $30{\times}30$ cm from 20 DAT until 60 DAT. Among the three planting densities, SPAD values were significantly greater in planting density of $20{\times}20$ cm both in Sobibyeo and Dongjinbyeo followed by $30{\times}30$ cm compared with closer planting density of $10{\times}10$ cm. The lowest grain yield was observed in wider planting density of $30{\times}30$ in both Sobibyeo and Dongjinbyeo due to lower number of panicle per unit area. Our findings suggest that optimum planting density for SRI in no-tillage paddy was $20{\times}20$ cm and it should be useful the systems to small-scale rice farmers in Korea as a sustainable farming system.

노년 비만남성의 의복 사이즈체계 연구를 통한 실버 의류산업 활성화 기반 구축 (Building up the foundation for the elderly apparel industry through the study on a clothes-sizing system of elderly obese males)

  • 성옥진;김숙진
    • 복식문화연구
    • /
    • 제27권6호
    • /
    • pp.632-644
    • /
    • 2019
  • This study presents an efficient clothes-sizing system for those experiencing obesity in old age with the aim of revitalizing the clothing industry for older obese people. The study targets 249 obese men aged 60 to 85 who satisfy a Rohrer index score of 1.6 or higher and a BMI (body mass index) of 25 or higher. Elderly obese males showed more obesity in the body based on the waist. In particular, those in their 60s were the most obese, and after reaching their 70s, characteristics of old age in which the stature was reduced and the limbs were tapered were shown. The clothes-sizing system was set to 5cm in stature, 5cm and 3cm in chest girth, 2cm in waist girth (omphalion), and 2cm in hip girth according to the KS standards. Through the two-way distribution of each section, the name of the section with a high distribution was given. Casual tops were selected from eight sizes, ranging from 155 to 170cm in stature and 95 to 105cm in chest girth. Suit top sizes were selected from eight sizes, ranging from 160 to 170cm in stature and 94 to 103cm in chest girth. Bottoms suggested 10 sizes distributed between 90 and 100cm in waist girth (omphalion) and 92 and 98cm in hip girth. According to the KS standards, the detailed size was divided into the basic part and the reference part.

Terra MODIS 영상과 지상 적설심 자료를 이용한 적설분포도 구축기법 연구 (Mapping Technique for Heavy Snowfall Distribution Using Terra MODIS Images and Ground Measured Snowfall Data)

  • 김샛별;신형진;이지완;유영석;김성준
    • 한국지리정보학회지
    • /
    • 제14권4호
    • /
    • pp.33-43
    • /
    • 2011
  • 본 연구는 2001년 1월, 2004년 3월, 2005년 12월 그리고 2010년 1월의 4개 폭설사상을 대상으로 3가지 적설심분포도를 구축하고 그 결과를 비교하고자 하였다. 첫째는 우리나라 76개의 지상기상관측소의 최심적설자료를 대상으로 IDW (Inverse Distance Weighting) 기법을 적용하여 구축한 경우(Snow Depth Map; SDM), 둘째는 SDM를 Terra MODIS (MODerate resolution Imaging Spectroradiometer) 영상에 의한 적설분포지역(Snow Cover Area; MODIS SCA)으로 추출한 경우(SDM+MODIS SCA; SDM_M), 셋째는 둘째 경우에 DEM (Digital Elevation Model)을 이용하여 고도에 따른 적설심 감률을 고려한 경우(SDM_M+DEM; SDM_MD)이다. 4개년도의 적설분포도를 작성한 결과, Terra MODIS 영상에 의한 적설분포면적은 남한면적($99,575.3km^2$)의 62.9%, 44.1%, 52.0%, 69.0% 였다. 3가지 경우에 대한 평균 적설심을 비교한 결과, SDM보다 SDM_M이 각각 0.9cm, 1.9cm, 0.8cm, 1.5cm 작게, SDM_M보다 고도를 고려한 SDM_MD는 1.3cm, 0.9cm, 0.4cm, 1.2cm 크게 나타났다.

용융염-액체금속 계의 대용물인 물-수은 계에서 액체금속 액적의 생성에 대한 연구 (A Study on the Droplet Formation of Liquid Metal in Water-Mercury System as a Surrogate of Molten Salt-Liquid Metal System at Room Temperature)

  • 김용일;박병기
    • 방사성폐기물학회지
    • /
    • 제16권2호
    • /
    • pp.165-172
    • /
    • 2018
  • 용융염-액체금속 추출공정에서 형성되는 액적 크기를 추정하는 방안으로 용융염-액체금속 계를 상온에서 유사한 물-수은 계로 대체하여 액적 형성 실험을 노즐의 종류에 따라 수행하여 Scheele-Meister 모델의 적용성을 평가하였다. 실험에서 액적의 크기 측정은 디지털카메라와 이미지분석 소프트웨어를 사용하였으며 노즐은 0.018 cm과 0.025 cm의 구멍 크기를 가지며 수은의 통과 길이가 1.3 cm인 상용 니들과 두께가 0.5 cm이며 0.0148 cm 구멍 2개, 0.0135 cm 구멍 3개, 0.0135 cm 구멍 4개인 것을 제작하여 사용하였다. 각각의 노즐에서 형성된 액적은 노즐 아래 20 cm까지 안정적인 구형을 유지하였다. 액적 크기의 측정치를 Scheele-Meister 모델의 추정치와 비교하였을 때 10% 오차 범위 안에서 일치하였다. 실험 결과는 물-수은 계에서 액적을 안정적으로 형성시키는 노즐에 대해 액적 크기 추정을 위한 Scheele-Meister 모델이 적용될 수 있음을 보였다.