• 제목/요약/키워드: CM Service Results

검색결과 211건 처리시간 0.026초

Development of Precise Point Positioning Method Using Global Positioning System Measurements

  • Choi, Byung-Kyu;Back, Jeong-Ho;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권3호
    • /
    • pp.217-223
    • /
    • 2011
  • Precise point positioning (PPP) is increasingly used in several parts such as monitoring of crustal movement and maintaining an international terrestrial reference frame using global positioning system (GPS) measurements. An accuracy of PPP data processing has been increased due to the use of the more precise satellite orbit/clock products. In this study we developed PPP algorithm that utilizes data collected by a GPS receiver. The measurement error modelling including the tropospheric error and the tidal model in data processing was considered to improve the positioning accuracy. The extended Kalman filter has been also employed to estimate the state parameters such as positioning information and float ambiguities. For the verification, we compared our results to other of International GNSS Service analysis center. As a result, the mean errors of the estimated position on the East-West, North-South and Up-Down direction for the five days were 0.9 cm, 0.32 cm, and 1.14 cm in 95% confidence level.

철근콘크리트 보의 철근부식에 미치는 하중의 영향에 관한 연구 (Influence of Loading on the Corrosion of Reinforcing Bar)

  • 김형래;윤상천;지남용
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.171-179
    • /
    • 1999
  • The present research investigated the interaction among loading level, corrosion rate and flexural deflection of reinforced concrete beams. 10cm$\times$15cm$\times$110cm reinforced concrete beams were prepared and subjected to different levels of flexural loading, including 0%, 45% and 75% of the ultimate load. The beams with either a pre-load or a sustained load were also exposed to a laboratory environment with ponding and wetting/drying cycling at room temperature. Half cell potential and galvanized current measurements were taken to monitor corrosion process of reinforcing steel. After corrosion initiation, external current was applied to some of the beams to accelerate corrosion propagation. The beam deflections were recorded during the entire tests. The results indicate that loading level has significant effect on corrosion rate. The beams under a sustained load had much higher corrosion rate than the pre-loaded and then unloaded beams. Significant corrosion may result in an increase in beam deflection and affect serviceability of the structure. The present research may provide an insight into structural condition evaluation and service life predictions of reinforced concrete.

용접 및 연마에서 발생되는 나노입자 특성 평가 : 수농도 및 입경분포 분석 (Characterization of Nanoparticles from Welding and Grinding Processes: Evaluation of Number Concentration and Size Distribution)

  • 김부욱;김현욱
    • 한국산업보건학회지
    • /
    • 제22권3호
    • /
    • pp.184-190
    • /
    • 2012
  • Objectives: This study aimed to characterize the nanoparticles produced by welding and grinding processes. Methods: The number concentrations of particles were mapped to determine the distribution of welding fumes in a workplace atmosphere using a hand-held condensation particle counter. An electrical low-pressure impactor was used for measuring the number concentration and particle size distribution. Results: High number concentrations were found around arc cutting and welding (grinding) processes. In the worker's breathing zone, the mean number concentration was 655,000 particles/cm3 and the count median diameter (CMD) was 84 nm with several multi peak distributions (~20, 70, 300 nm). However, at a distance of 3 m from the welding position, the number concentration decreased to 153,000 particles/cm3 with a 70 nm single peak size distribution. During a grinding process, peaks with high concentrations of nanoparticles were temporarily observed. The mean number concentration was 1,520,000 particles/cm3, and the CMD was 30 nm. Nanoparticles (<100 nm) made up 58% and 92% of the aerosols produced by welding and grinding processes, respectively.

투수콘크리트의 공극막힘현상에 대한 실험적 연구 (Experimental Study on the Pore Clogging Phenomenon of Porous Concrete)

  • 남정만;윤중만;김승현;송영석
    • 대한토목학회논문집
    • /
    • 제31권4D호
    • /
    • pp.577-584
    • /
    • 2011
  • 본 연구에서는 도로포장재로서 사용되는 투수콘크리트의 공극막힘현상(pore-clogging)을 실험적으로 규명하기 위하여 일련의 현장투수시험과 실내투수시험을 실시하였다. 굵은 골재 최대치수($G_{max}$)가 13mm인 투수콘크리트로 시공된 제주지역의 37지점을 대상으로 현장투수시험을 실시한 결과 투수콘크리트 포장재의 투수계수 수명한계를 0.01cm/sec로 설정할 경우 투수콘크리트 포장재의 수명한계는 약 22개월로 확인되었다. 한편, 투수콘크리트의 공극막힘현상을 재현하기 위하여 투수콘크리트 공시체를 제작하였으며, 공극막힘재 투입농도가 공시체의 굵은 골재 최대치수($G_{max}$)에 따른 실내투수시험을 실시하였다. 실험결과 막힘재의 투입농도에 커질수록 투수콘크리트의 수명한계는 급격하게 감소하며, 투수콘크리트의 굵은 골재 최대치수($G_{max}$)가 커질수록 투수콘크리트의 수명한계는 증가하는 것으로 나타났다. 따라서 투수계수 수명한계에 이르는 시간은 공극 막힘재의 농도와 반비례 관계가 있으며, 굴은 골재 최대치수($G_{max}$)와 비례 관계가 있다. 그리고 일반적인 조건에서 투수콘크리트의 내구연한은 공극막힘재의 농도와 굵은 골재 최대치수($G_{max}$)에 따라 간접적으로 예측이 가능함을 알 수 있다.

토양중 fenoxaprop-P-ethyl의 흡착성 및 이동성 (Adsorption and Movement of Fenoxaprop-P-ethyl in Soils)

  • 한수곤;안병구;문영희
    • 한국잡초학회지
    • /
    • 제18권4호
    • /
    • pp.325-332
    • /
    • 1998
  • 미사질식토와 사양토 중 fenoxaprop-P-ethyl의 흡착성과 이동성에 대하여 연구 검토하였다. 두 토양 중 fenoxaprop-P-ethyl은 진탕 30분 후에 약 15%가 흡착되었으며 8~14시간 후에는 의사평형에 도달하였고 50%가 흡착되는 시간은 미사질식토에서 15.8시간, 사양토에서 19.3시간이었다. 본 제초제의 흡착은 Freundlich식에 따랐으며 흡착분배계수(Kd)값은 미사질식토에서 3.86, 사양토에서 2.32이었다. 두 토양의 컬럼에서 fenoxaprop-P-ethyl은 처리 7일 후에는 6cm, 21일 후에는 8cm까지 이동되었으나, 이동성은 누수량의 증가와 더불어 증가되었다. 포장조건의 두토양 중 fenoxaprop-P-ethyl은 처리 14일 후에는 6cm층위까지, 56일 후에는 8cm 층위까지 이동되었다. 그러나 어느 경우이든 처리된 fenoxaprop-P-ethyl의 대부분은 0-2cm 층위에 존재하였다. Fenoxaprop-P-ethyl의 반감기는 1주 이내이었으며 처리 4주 후에는 처리량의 약 90%정도까지 분해되었다. 이상의 결과를 종합하여 볼 때 토양 중 fenoxaprop-P-ethyl은 비교적 이동성이 작고 분해가 빠른 편인 바 주변환경에 대한 위해성이 낮을 것으로 사료된다.

  • PDF

닥스훈트의 원발성 비장 혈관주위세포종 증례 (Primary splenic hemangiopericytoma in a dachshund dog)

  • 김성재;양돈식;한정희
    • 한국동물위생학회지
    • /
    • 제35권2호
    • /
    • pp.153-157
    • /
    • 2012
  • A 7-year-old, castrated male dachshund dog with tumor of the spleen portion was referred to the Kangwon National University. The tumor removed surgically and tumor size was 6~7 cm. Histopathologically, this neoplasm was the presence of perivascular whorls of fusiform cells. The cells also arranged in interlacing bundles or storiform patterns. And this neoplasm consisted of spindle cells that often formed distinct whorls around a central capillary. Immunohistochemical analysis revealed multi-focally immunoreactivity for ${\alpha}$-smooth muscle actin, whereas not immunoreactive for desmin, S-100, von Willebrand factor. On the base of the histological and immunohistochemical results, this neoplasm was diagnosed as a canine hemangiopericytoma.

Refinements of Adipofascial flap for Small Defects of Fingers and Toes: Indication and Surgical Tips

  • Chung, Yoon-Kyu;Choi, Jin-Hee;Kim, Jiye;Chung, Seum
    • Archives of Reconstructive Microsurgery
    • /
    • 제25권2호
    • /
    • pp.25-28
    • /
    • 2016
  • Purpose: Reconstruction of small defects of the dorsal fingers and toes is a challenging task. Although adipofascial flap is widely used for these areas, additional refinements are warranted. In this paper, we define the appropriate defect size in the finger and toes that can be treated with the adipofascial flap, refine its surgical indications and present a few surgical tips. Materials and Methods: Twelve patients with dorsal defects of the fingers and toes were treated with a random-type adipofascial turn-over flap and skin graft. If the defect area exceeded the size that could be covered by a conventional design, the flap base was designed in oblique or curvilinear fashion to lengthen the flap. For accurate defect coverage, the width of the flap base was designed in an asymmetrical shape depending on the defect configuration, varying the width from 0.3 to 1.0 cm, as opposed to the standard 0.5 to 1.0 cm width. Moreover, the lateral limit of the flap was defined as the lateral axial line. The size of the defect ranged from $3.0{\times}1.7cm$ to $1.5{\times}1.3cm$. Results: All flaps survived completely. Gliding function of the hand was well preserved and there was no evidence of tendon adhesion. Conclusion: The small defect in the dorsal finger and toe can be defined as less than one phalanx-length, measuring about $3.0{\times}2.0cm$ in size. If the defect exceeds this dimension, it is recommended that a different option be considered. We believe the adipofascial flap is an excellent option for treating small defects.

쌀가루의 입도에 따른 쌀 식빵의 품질 특성 (Effects of Rice Powder Particle Size in Baked Rice Breads)

  • 박미경;이광석;이경희
    • 동아시아식생활학회지
    • /
    • 제18권3호
    • /
    • pp.397-404
    • /
    • 2008
  • The purpose of this study was to help promote the consumption of rice by substituting rice powder for wheat flour in bread preparation and examining the effect of rice powder particle size in baked rice bread samples. Several experiments were carried to analyze and compare the quality characteristics of prepared samples of wheat flour and rice powder breads. The loaf volume index of the wheat flour bread was 6.34, and the indices of the rice powder bread samples, which were made from powder milled through 20, 35, and 45 mesh (S1, S2 and S3), were 5.37, 5.56, and 5.85, respectively. These data indicated that the loaf volume index of the rice powder bread was lower than that of the wheat flour bread, but the volume of the rice powder bread increased as the particle size of the rice powder became finer. According to texture analysis results using a rheometer, the hardness value of the wheat flour bread was $1.34{\times}10^3\;g/cm^2$, and values of S1, S2, and S3 were $1.74{\times}10^3\;g/cm^2$, $1.57{\times}10^3\;g/cm^2$, and $1.47{\times}10^3\;g/cm^2$, respectively. Therefore, S3, which was made from the finest powder among the rice powder samples, showed the lowest level of hardness. No significant differences were observed for springiness, cohesiveness, and gumminess among the bread samples. However, the wheat flour and rice powder breads had significant differences for bread crumb color. The L-value of S3(76.20) was similar to that of the wheat flour bread(77.22). but the L-values of S1(70.30) and S2(71.21) were lower than that of the wheat flour bread. In terms of redness and yellowness, the values of the rice powder breads were significantly different from those of the wheat flour bread. In terms of overall preference, the sensory evaluation results indicated that S3 was significantly the more preferred and the wheat flour bread was the least preferred among the bread samples. This study also investigated texture changes and mold occurrence in bread samples stored at $25^{\circ}C$ for 5 days. From the 3rd day of storage, bread texture became harder in all samples however, S3 showed the least level of change among the rice powder breads. The occurrence of mold began to increase abruptly from the 4th day of storage, and S2 and S3 showed mold numbers that were 2-fold greater than those of S1 and the wheat flour bread.

  • PDF

Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC

  • Kim, Young-Rok;Park, Eunseo;Oh, Hyungjik Jay;Park, Sang-Young;Lim, Hyung-Chul;Park, Chandeok
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.269-277
    • /
    • 2013
  • In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion $X_P$ and $Y_P$ are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.

Effect of Myofacial Release and Cryotherapy in Acute Whiplash Injury

  • Park, Si Eun;Lee, Joon Hee;Wang, Jung San;Choi, Yoo Rim;Park, Joo Hyun;Lee, Ju Hwan;Choi, Young Duk;Hwang, Hyun Sook;Kim, Soon Hee
    • 국제물리치료학회지
    • /
    • 제5권1호
    • /
    • pp.647-651
    • /
    • 2014
  • The purpose of this study is to provide the case of influence of myofacial release(MFR) and cryotherapy in acute whiplash injury. The subjects were consisted of 3 adults(2 males, 1 female) who had been diagnosed with whiplash injury. The performance period was 1 weeks, 6 times and 1 time is 40min(MFR: 20min, cryotherapy: 20min). We measured neck pain(Visual analogue scale, VAS) and cervical alignment(cervical curvature & line of gravity). All measurements of each subject were measured at pre-treatment and post-treatment. The results are listed below. The neck pain(VAS) index decreased from 7.54cm to 4.11cm. The cervical curvature increased from $23.62^{\circ}$ to $29.76^{\circ}$. The line of gravity decreased from 8.03mm to 3.66mm. Based on the results, it can be suggested that both MFR and cryotherapy can be used to neck pain and alignment in acute whiplash injury.