• Title/Summary/Keyword: CM산업

Search Result 789, Processing Time 0.024 seconds

Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system (사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae Hyeung;Li, Xiao Yu;Ha, Hyun Chul;Jung, Jae Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

Effects of Chlorine Residual and Pipe Material on the Biofilm Formation in Drinking Water Distribution Pipe (수도관의 생물막 형성에 미치는 잔류염소와 파이프 재질의 영향)

  • Park, Se-keun;Park, Jae-Woo;Sung, Kwon-Shic;Choi, Sung-Chan;Kim, Yeong-Kwan
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.11-20
    • /
    • 2001
  • This laboratory study examined the impact of free chlorine residual and pipe material on the formation of biofilm in drinking water distribution pipe surfaces. Result of heterotrophic plate counts(HPC) of the biofilm in the tap water-supplied reactor averaged $2.17{\times}10^5CFU/cm^2$ on PVC and $2.43{\times}10^5CFU/cm^2$ on STS 316, respectively. HPCs on the surface exposed to the tap water containing 0.2mg/L of free chlorinne residual averaged $4.24{\times}10^4CFU/cm^2$ on PVC and $6.54{\times}10^4CFU/cm^2$ on STS 316, respectively. Average of HPC/Total direct counts in the tap water-supplied reactor ranged from 1.08%(PVC) to 1.26%(STS 316) and from 0.38%(PVC) to 0.65%(STS 316) in the reactor supplemented with disinfectant, respectively. No correlation was observed between disinfectant addition and biofilm density. With regard to the biofilm formation, little difference existed between PVC and STS 316. Yellow and red pigmented bacteria were the dominant expressions in bulk fluid, whereas non-pigmented bacteria were found dominant in the biofilm. Pink/red pigmented bacteria were found to be facultative anaerobic, while yellow pigmented bacteria and non-pigmented bacteria were found to be obligate aerobic.

  • PDF

Saline Water Movement In The Estuary Of The Nakdong River (낙동강 하구의 염수운동)

  • Chang, Sun-duck;Ryu, Cheong-ro;Lee, Mun-ok;Lee, Jae Chul
    • 한국해양학회지
    • /
    • v.16 no.1
    • /
    • pp.31-37
    • /
    • 1981
  • Saline water movements in relation to tidal condition and river discharge in the estuary of the Nakdong River are discussed on the basis of the observation data. The difference of salinity between the surface and the bottom layer was 1∼3 at spring tide forming a vertically homogeneous estuary, while at neap tide, it ranges up to 7∼15 indicating a sharp salt wedge. The maximum salinity appeared approximately at an hour after the high water, that is, three hours after the landward velocity maximum, while the salinity maximum at around an hour after the low water, that is, three hours after the seaward velocity maximum. The density current speed at a section located 10km landward from the river mouth was observed approximately to be 45cm sec$\^$-1/ at 8m layer.The relations between the salinity at Gupo and the river discharge at Jindong are estimated by means of the least square method. The maximum length of the salt wedge is calculated approximately to be 22km at neap tide and 16km at spring tide, which is in accordance with the observed data. The salinity influence area is deduced to be 45km at spring tide and 35km at neap tide. The diffusion coefficient of salinity was estimated approximately to be 1.5 10$\^$8/$\textrm{cm}^2$ sec$\^$-1/ at Samrak and 8 10$\^$5/$\textrm{cm}^2$ sec$\^$-1/ at Gupo at neap tide, while it was 1.4 10$\^$7/$\textrm{cm}^2$ sec$\^$-1/ at Dongwon at spring tide.

  • PDF

A Study on Data Gata Gateway for Indoor Location Detection and Its Upload (실내 위치정보 확인 시스템 및 데이터 게이트웨이 구현에 대한 연구)

  • Cho, Youngseok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.1
    • /
    • pp.63-69
    • /
    • 2016
  • Although the previous information technologies had been used for the quick and accurate processing of work, At present, however, as the combination with the Internet, the IOT(Internet-of-Things) era in which the diverse pieces of information are collected and handled through the sensor networks is in progress. Among these application fields of the IoT, the indoors position identification technology has been developing in the direction of providing the position information in the buildings of which the lengths and the interiors are complicated and in the direction of providing the various pieces of information and others of the like to the nearby customers. In this paper, we proposed an indoors position identification system that detects the patrol positions of the prison officers in the correctional facilities and in the prisons by using the ultrasonic waves, that transmits these to the control system and the data gateway, and that transmits the detected data. The Indoors Positioning identification System is organized with the tags for recognizing the positions that transmit the ultrasonic signal, ultrasonic receiver and data gateway. And the indoors position information data were transmitted to the management system through the data gateway. We evaluated the transmission error, by changing the distance of the proposed system for location recognition tag and the receiver, As a result, we found out that, when the transmission distance was 10 cm or less, the errors occurred in the form of the distortions. And when it was 110 cm or more, the transmission errors occurred due to the propagation diminutions of the ultrasonic wave signals. And when the transmission distance was from 10 cm to 100 cm, it was shown that the proposed system was possible without any errors.

A Study on the Collar Construction Factors of the Women's Tailored Jacket (여성복 테일러드 재킷의 칼라제작요인에 관한 연구)

  • Kim, Gu-Young;Kim, Yeo-Sook
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.947-954
    • /
    • 2008
  • The purpose of this research is to find out related factors to obtain the best collar pattern of the women's tailored jacket by analyzing the difference of the shapes between the drafted pattern and that of being stitched. The experimental conditions established are as follows. The position and angle of its break point, the notch and the width of the collar and lapel are kept unchanged. The collar decrease in neckline edge and the top collar larger than the under collar. The crossing point of gorge line is changed to make the collar's roll line straight. When the pattern is changed to make the outline of the lapel straight, the amount of cloth is changed too. According to the experimental conditions, The experimental clothes using muslin were made to. put on the manikin and the suitable methods of making the collar pattern were decided. In order to find out the influence of fabric materials on the jacket' shapes, Three kinds of wool fabrics were used and the results were evaluated. Summary of the research is as follows. When 0.5cm of the neckline edge is shortened, the standing part of the collar has less wrinkles, and its position looks natural and lastly, the material has slightly affected the collar's condition. It is desirable to make the top collar 0.2cm longer than the under collar. But the length should be different according to the fabric material. It it is thick cloth, the length has to be extended. To make the roll line straight, 0.4cm of the crossing point of gorge line should be corrected. The thick cloth needs more correction. To make the lapel's outline straight, it needs outwardly round 0.2cm more and materials make little difference to affect the shape.

The Influence of the Interval of Polka Dots on the Image of Clothes - Focused on One-Piece Dress - (물방울무늬의 간격이 의복이미지에 미치는 영향 - 원피스드레스를 중심으로 -)

  • Choi, Hye-Won;Ryoo, Sook-Hee
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.278-285
    • /
    • 2007
  • The purpose of this study is the image of clothing according to the change of the dots' interval was analyzed and its influence on the formation of the image of polka dots clothing was investigated. White waterdrop patterns were designed on the 12 kinds of black texture using Photoshop and CAD program in regular arrangement of diamond figure, composed of white waterdrop(0.5 cm, 1.0 cm, 1.5 cm and 2 cm in diameter) and interval(diameter : interval - 1 : 1, 1 : 2, 1 : 4). Applying above specification, the photograph stimulus of 12 kinds of X-line one-piece dress with wide square neckline and without sleeve or detailed ornament was presented on a screen in the same size as when putting it on. The image of polka dots clothes was investigated by questionnaire survey. The object of the study was 320 females aged between 16 and 29. Factor analysis, one-way ANOVA, Scheff$\acute{e}$ verication and two-way ANOVA using SPSS 10.0 were carried out for data analysis. The research finding are as follows. First, the image of polka dots clothing consists of 4 factors as aesthetics, brevity, dynamism and lightweight. Secondly, the interval of the dot has a great influence on the formation of the image of polka dots clothing. Lastly, the evaluations of the image of polka dots clothing were different depending on the age and physical image, the personal characteristics of the object of investigation.

Feasibility Study of Gamma Ray Transmission Technique in Distillation Column Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 감마선 투과계측 증류탑 진단기술의 타당성 연구)

  • Moon, Jinho;Kim, Jongbum;Park, Jang Guen;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.115-119
    • /
    • 2013
  • The density profile measurement technology by gamma transmission has been widely used to diagnose processes in the field of refinery and petrochemical industry. This technology can reveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in the amount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulations assumed that $^{60}Co$ (1.17, 1.33 MeV) sources and NaI (Tl) detectors (${\Phi}5{\times}5cm$) are located in opposite sides of a column and it concurrently moves in vertical direction. To determine the dependency of a spatial resolution on aperture size of a collimator, the simulation model for a tray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the high density area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of the tray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profile measurement technique is not able to show the deviation of liquid level on a tray in a column.

Several Functional Properties of Freeze-dried Powder of Pre-concentrated Aloe vera gel (농축 전처리된 Aloe vera gel의 동결건조분말의 기능성)

  • Lee, Nam Jae;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.13 no.3
    • /
    • pp.216-220
    • /
    • 2009
  • The several functional properties of freeze-dried powder of Aloe vera gel was examined as influenced by pre-concentration degrees of the gel solution. As a pre-treatment prior to freeze drying, the gel solution was vacuum-concentrated by three levels (unit: g-water/g-solids) - high (H), 76; medium (M), 119; low (L), 159. In FT-IR spectra, the sample H showed the highest absorbance in the range of 1600-1550 $cm^{-1}$ and 1450-1400 $cm^{-1}$, which corresponded to level of the acetyl group in glucomannan. The sample H of freeze-dried powder was the highest in polysaccharide content, jack bean urease inhibition rate, and FAC (fat adsorption capacity). It could be inferred that the sample H had an effect on Helicobacter pylori inhibition and fat adsorption suppression according to urease inhibition rate and FAC, respectively.

A Study on the Lower Body Shape and Life Status of Elderly Women according to the Progress Group of Varus (노년 여성의 내반슬 진행집단에 따른 하반신 형태 및 생활실태 분석)

  • Jang, Ji Hyeon;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.21 no.3
    • /
    • pp.326-335
    • /
    • 2019
  • This study categorized 100 female subjects over 65 years of age into two groups. The first group is called 'early stage of varus', which is when the gap between the knees is less than 5 cm. The second group is called 'progressive varus', which is when the gap between knees is 5 cm (or more). We then analyzed their lower body shapes and life status. The results were as follows. The average gap between knees in the early stage group and the progressive group was 3.3 cm and 6.2 cm. Direct and indirect measurements of their lower bodies showed that subjects in the progressive group had longer legs than the other group because their legs were bent outwards. Most of the subjects were found to live in western housing conditions, but maintained sedentary lifestyles. A total of 60% of the subjects thought that they were in bad health conditions and said that they found it difficult to move their knees dynamically; in addition, 63.6% of the subjects in the early stage group and 73.5% of the subjects in the progressive group suffered from arthritis. Subjects in the progressive group were more aware than the other group that their legs were bent outwards. They also responded that bent legs do harm to their appearance and make their lives uncomfortable. Most senior females with varus did not seek medical treatment and did not buy clothes that can help change their varus. However, 95% of the subjects responded they were in need for clothes that could straighten the varus-type.

Comparison and Evaluation of Clothing Insulation of Newly-Developed Air-Filled Baffle Jackets and Down Padded Jackets (새롭게 개발된 겨울용 공기주입형 배플 패딩 재킷과 기존 방한 패딩 재킷들의 보온력 비교 평가)

  • Kwon, JuYoun;Kim, Siyeon;Baek, Yoon Jeong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.23 no.2
    • /
    • pp.261-272
    • /
    • 2021
  • The purpose of the present study was to evaluate the thermal insulation of air-filled winter jackets according to the amount of air-filler using a thermal manikin. The insulation of these jackets' was compared to a down padded jacket with an identical design and size. The amounts of air-filler were 100% (26,219 cm3), 70% (18,645 cm3), 50% (13,110 cm3), and 0% (0 cm3). The results showed that a clothing insulation (Icl) of 0%, 50%, 70%, and 100% air, and 100% down jackets was 0.208, 0.243, 0.207, 0.176, and 0.315 clo, respectively. In addition, the down jacket with waisttaped had a clothing insulation of 0.369 clo. However, the highest value of clothing insulation per clothing weight was the 50% air-filled jacket in all conditions. In terms of regional power consumption of the thermal manikin, the down jacket consumed less power for the shoulder and chest than the air-filled jackets. In conclusion, in order to maximize the thermal insulation of air-filled jackets, an optimal amount of air-filler, that is, an amount which does not compromise (break) the layer of inner air between the surface of manikin and the lining of the jacket, should be explored. Further studies on lining materials, end-closed design, and changes in thermal insulation under the conditions of strong wind or heavy snow are recommended.