• Title/Summary/Keyword: CLEAN

Search Result 5,311, Processing Time 0.035 seconds

Evaluation of the Effect of Various Root Planing Instruments on the Root Surfaces (수종의 기구를 이용한 치근면 활택술후 치근면의 변화)

  • Kim, Tae-Beom;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.65-80
    • /
    • 1999
  • The purpose of this study was to evaluate the effects of periodontal curet and various rotating instruments on the root surfaces. Thirty-five extracted teeth with advanced periodontal disease were used. They was root planed with periodontal curet, periodontal Perio-Clean bur, periodontal Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur. To find dentinal tubule orifices on the root surface, tetracycline HCI solution was applied to the one tooth of treated each group. Then, root surfaces were investigated using scanning electron microscope. Amount of loss of cementum was evaluated by loss of tooth substance index. The results were as follows. 1. Groups treated with periodontal curet and Perio-Clean bur showed irregular surface and concavities. Concavities seemed to be lacunae of cementocyte. Other groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur showed partially opened dentinal tubule orifice. 2. Groups treated with periodontal curet and Perio-Clean bur and tetracycline HCl showed irregular surface. No dentinal tubule orifice was seen. Other groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur and tetracycline HCl showed dentinal tubule orifice with various shape and size. 3. Loss of tooth substance indices were compared between groups. There was no statistically difference between periodontal curet and Perio-Clean bur groups. There were statistically differences between periodontal curet and Roto-Perio bur, ET bur, and diamond fissure bur groups. As a result of this study, groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur showed more cementum removed than groups treated with periodontal curet and Perio-Clean bur. Therefore, in a conventional treatment for periodontal disease, it was recommended that periodontal curet or Perio-Clean bur should be used. In a treatment for regeneration of periodontal tissue, it was recommended that Roto-Perio bur, resin polishing ET bur, or resin polishing diamond fissure bur should be used

  • PDF

Strategy for the Development of Innovative Clean Technology in Korea (국내 미래청정기술 개발을 위한 전략)

  • Kim, Young Dae;Sim, Sang Jun;Lee, Joong Ki;Choi, Guang Jin;Park, Tae-Jin;Cho, Young Sang
    • Clean Technology
    • /
    • v.3 no.1
    • /
    • pp.9-26
    • /
    • 1997
  • The recent movement toward the better environment urges the shift of pollution prevention strategy from traditional "command/control" and "end-of-pipe" technologies to clean technologies. Development of Clean Technology, which makes products without creating pollutions, is a way to solve Environmental problems fundamentally. The main objective of this study is to define the long-term strategy to develope "Innovative Clean Technology". "Innovative Clean Technology" is an active way of solving the environmental problems arising from industrial activities. It aims to find ways either to make products without creating pollution, to produce environmentally benign end-products, or else to recover and re-use the materials which have hitherto considered waste.

  • PDF

Performance Prediction Model of Solid Oxide Fuel Cell Stack Using Deep Neural Network Technique (심층 신경망 기법을 이용한 고체 산화물 연료전지 스택의 성능 예측 모델)

  • LEE, JAEYOON;PINEDA, ISRAEL TORRES;GIAP, VAN-TIEN;LEE, DONGKEUN;KIM, YOUNG SANG;AHN, KOOK YOUNG;LEE, YOUNG DUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.436-443
    • /
    • 2020
  • The performance prediction model of a solid oxide fuel cell stack has been developed using deep neural network technique, one of the machine learning methods. The machine learning has been received much interest in various fields, including energy system mo- deling. Using machine learning technique can save time and cost requried in developing an energy system model being compared to the conventional method, that is a combination of a mathematical modeling and an experimental validation. Results reveal that the mean average percent error, root mean square error, and coefficient of determination (R2) range 1.7515, 0.1342, 0.8597, repectively, in maximum. To improve the predictability of the model, the pre-processing is effective and interpolative machine learning and application is more accurate than the extrapolative cases.

Characteristics of Binderless Briquettes for Indonesian Low-Rank Coals (인도네시아 저등급석탄의 무결합제 성형 특성)

  • Chun, Dong Hyuk;Rhim, Young Joon;Kim, Sang Do;Yoo, Jiho;Choi, Ho Kyung;Lim, Jeong Hwan;Lee, Sihyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.231-235
    • /
    • 2015
  • The characteristics of binderless briquettes for dried low-rank coal was studied in this work. Two kinds of Indonesian coals were used to briquette after drying them in electric oven. The characteristics of briquettes have been examined by moisture contents, particle size, hydraulic force, and storing period. The optimum moisture contents of briquettes were observed at between 10 wt% and 15 wt%. The strength of coal briquette was stronger as particle size became smaller. The strength of coal briquette was proportional to the hydraulic force under 300 kN, whereas there was little difference among the briquettes made at more than 300 kN of hydraulic force. The strength of briquettes sharply decreased for a week after produced, and then showed the tendency of converging. The results from this work can be a useful guideline of manufacturing and managing upgraded coal briquettes.

Stabilization Characteristics of Upgraded Coal Using Palm Oil Residues (팜 잔사유를 이용한 고품위화 석탄의 안정화 특성분석)

  • Park, In Su;Chun, Dong Hyuk;Jo, Wan Taek;You, Ji Ho;Lee, Si Hyun;Rhee, Young Woo
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.469-475
    • /
    • 2013
  • In this research, the stabilization characteristics of upgraded coal using palm oil residues were investigated. The Eco coal, which is the Indonesian low-rank coal, was used as a raw material. The low-rank coal was mixed with palm fatty acid distillate (PFAD), and then dried in a nitrogen atmosphere at $107^{\circ}C$. The trend of spontaneous combustion of upgraded coal was studied by measuring of crossing-point temperature (CPT), low temperature oxidation and moisture readsorption. The results of the CPT measuring and low temperature oxidation showed that the propensity of spontaneous combustion of the upgraded coal was improved compared to the dried coal. The moisture readsorption characteristics of the upgraded coal was also improved. The upgraded coal was stabilized through the surface coating with PFAD, and stability of upgraded coal was proportional to the content of PFAD.

Application of Coliform Bacterial Plasmid as a Trophic Indicator (콜리형 세균 Plasmid의 영양단계 지표 활용에 관한 연구)

  • Cho, Hong Bum
    • The Korean Journal of Ecology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 1988
  • This present study has been carried out to examine the correlation between the distribution of the coliform bacterial plasmids and the viability test against heavy metals in the upper stream of Han river(Gapyung; clean water) and the its basin (Anyang Cheon; polluted water). And the distribution of plasmids were examined to be used as trophic indicator for analysis between the clean and polluted waters. 1. A total of 110 isolates were analyzed for the presence of plasmids by means of the boiling method and agarose gel techniques. Plasmids were significantly more frequent in the strains which had been isolated from the clean water (14.3%). Also, there were much higher multiplicity of plasmids at the polluted water(41.0%), compared with the clean water (33.0%). By the comparision between molecular weight of bacterial plasmids in the clean water and those of polluted water, there were no significant differences of the clean water from the polluted water, to such extent as 30.0%, 28.6%, respectively, in frequency for occurrence of high molecular weight plasmids iver 35.8% Mdal. 2. Each isolate was carried out the resistance test for mercury(10-5M), nickel(10-3M) and arsenic (0.1%). At the polluted site, the survival ability of the plasmid-carrying straings(Hg, 31.0%l Ni, 5.7%; As, 65.7%) was higher than that of the non plasmid-carrying strains(Hg, 12.1%; Ni, 3.0%; As, 54.6%). This trend was more remarkable in the clean site (plasmid-carrying strains: 16.7%,-,-). As a result it is suggested that plasmids could be used as an indicator of a certain types of water pollution. In addition, heavy metals might have inflyenced, some extent, to the distribution of plasmids in the environment which has been surveyed in the present study.

  • PDF

Four-Week Repeated Oral Toxicity Study of Clean Natural in Sprague-Dawley Rats (Clean Natural의 Sprague-Dawley 랫드를 이용한 4주 반복경구투여 독성시험)

  • Kim, Eui-Kyung;Kim, Jun-Young;Lee, Hu-Jang
    • Toxicological Research
    • /
    • v.21 no.3
    • /
    • pp.263-269
    • /
    • 2005
  • This study was performed to investigate repeated-dose toxicities of Clean natural, a new disinfectant, in Sprague-Dawley(SD) rats. In the 4-week repeated oral toxicity study, Clean Natural was orally administered once daily via gavage to male and female rats at dose levels of 0, 500, 1,000 and 2,000 mg/kg body weight for 4-weeks. There were no deaths and clinical signs during the dosing period. In both sexes, there were no statistically significant differences between the administered and control groups in urinalysis indicators and hematological parameters. In serum biochemistry, aspartate aminotransferase(AST) was significantly decreased and sodium content was increased in the 2,000 mg/kg male group, while chlorine was significantly decreased in the 2,000 mg/kg female group. Also, albumin, total cholesterol and total bilirubin were significantly increased in the 2,000 mg/kg male and female group. In histopathological examinations, centrilobular hepatocellular hypertrophy in the liver was observed in the 2,000 mg/kg male and female groups. And pigmentation in the spleen was observed in the 2,000 mg/kg male group. In conclusion, four-week repeated oral dose of Clean Natural to rats did not cause apparent toxicological change at the dose less than 2,000 mg/kg body weight. Thus it is suggested that no-observed adverse-effect level(NOAEL) for Clean Natural in rats was considered to be 1,000 mg/kg/day.

Optimization of Microbial Electrosynthesis Using Rhodobacter sphaeroides for CO2 Upcycling (CO2 고부가화를 위한 로도박터 스페로이데스를 활용한 미생물 전기합성 최적화 연구)

  • Hui Su Kim;Hwi Jong Jung;Danbee Kim;Samgmin Lee;Jiye Lee;Jin-Suk Lee;Myounghoon Moon;Chang Hyun Ko;Soo Youn Lee
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.20-26
    • /
    • 2023
  • Emitted CO2 is an attractive material for microbial electrochemical CO2 reduction. Microbial electrochemical CO2 reduction (i.e., microbial electrosynthesis, MES) using biocatalysts has advantages compared to conventional CO2 reduction using electrocatalysts. However, MES has several challenges, including electrode performance, biocatalysts, and reactor optimization. In this study, an MES system was investigated for optimizing reactor types, counter electrode materials, and CO2-converting microorganisms to achieve effective CO2 upcycling. In autotrophic cultivation (supplementation of CO2 and H2), CO2 consumption of Rhodobacter sphaeroides was observed to be four times higher than that with heterotrophic cultivation (supplementation of succinic acid). The bacterial growth in an MES reactor with a single-chambered shape was two times higher than that with a double chamber (H-type MES reactor). Moreover, a single-chambered MES reactor equipped with titanium mesh as the counter electrode (anode) showed markedly increased current density in the graphite felt as a working electrode (cathode) compared to that with a graphite felt counter electrode (anode). These results demonstrate that the optimized conditions of a single chamber and titanium mesh for the counter electrode have a positive effect on microbial electrochemical CO2 reduction.