• 제목/요약/키워드: CIE $L^*a^*b^*$${\Delta}E^*$ value

검색결과 32건 처리시간 0.027초

수종의 색소체용액으로 제작된 유색 지르코니아의 색조비교 (The color comparison of zirconia fabricated by using various coloring liquids)

  • 오계정;정종현
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.247-253
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate the effect of colored zirconia with different coloring liquids. Methods: Total 30 specimens were prepared. Specimens were classified into 6 groups: IPS e.max Ceram(P), Uncolored zirconia(C), VITA In-Ceram$^{(R)}$2000 YZ LL1(L), Zirkonzahn coloring liquid(Z), Wieland coloring liquid(W), and Kuwotech coloring liquid(K). Four different types of zirconia coloring liquid, VITA In-Ceram$^{(R)}$ 2000 YZ LL1(VITA Zahnfabrik, Germany), Zirkonzahn coloring liquid(Zirkonzahn, Italy), Wieland coloring liquid(Wieland, Germany), Kuwotech coloring liquid(Kuwotech, Korea) were used to fabricate colored zirconia by using infiltrating method and then completely sintered. The color of the all specimens was measured using the spectrophotometer(CM-2600d, Konica Minolta, Japan) and expressed in terms of the 3-coordinated values(CIE $L^*a^*b^*$). Color differences were calculated using the equation $${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{1/2}$$. Results: $L^*a^*b^*$ values of the colored zirconia were affected by the coloring liquids. The uncolored zirconia(C) group showed the highest $L^*$ value and zirkonzahn coloring liquid(Z) group showed the lowest $L^*$ value. Zirkonzahn coloring liquid(Z) showed the highest $a^*$ value and VITA In-Ceram 2000 YZ LL1(L) group showed the highest $b^*$ value. Generally, the color difference(${\Delta}E^*$) in all groups showed higher than 3.7 except between IPS e.max Ceram(P) and wieland coloring liquid(W) group. Conclusion: Within the limitations of this study, various coloring liquids influenced the $L^*$, $a^*$, and $b^*$ values of colored zirconia. IPS e.max Ceram(P) and wieland coloring liquid(W) group did not show clinically perceiving color difference.

천연색소 추출공정에서 추출특성에 따른 목표색의 재현 (Presentation of Target Color with Extraction Variables in Natural Dyes Extraction)

  • 탁은수;배민우;강승현;배유진;강수연;정수경;홍인권
    • 공업화학
    • /
    • 제21권5호
    • /
    • pp.559-563
    • /
    • 2010
  • 천연색소를 이용한 컬러의 재현은 현대의 웰빙 생활과 밀접한 연관성을 갖게 된다. 이 연구는 일상생활에서 자주 쓰이는 녹색 계, 황색 계, 그리고 적색 계의 컬러를 자연 상의 녹차, 치자, 흑미를 색소원으로 하여 목표 색을 설정하였다. 목표색의 명도(L), 색 좌표(a, b)의 정량적 수치 값을 지정하고 추출용매의 물성을 조절함으로써 목표 색에 가장 접근하는 색을 추출하여 표현하였다. 색소추출 공정에서 용매의 pH, 추출온도, 추출시간이 변수로 설정되었다. 치자의 경우 추출시간이 길수록 진한색이 추출되었다. 추출색소는 색차계를 이용해 색의 L-a-b좌표를 측정하여 목표 색과 비교하였다. 실험조건을 최적화함으로써 목표 색과 가장 색차 값(${\Delta}E$)이 적은 녹색, 황색, 적색의 CIE 기준 값을 제시하고 이 좌표에 맞는 색을 표현하였다.

전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성 (Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;박광수
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.

국내 여성복 패선 이미지에 따른 배색 연구 (A Study of Color Combination based on Fashion Image of Domestic Women's Apparel)

  • 조주연;김영인
    • 복식
    • /
    • 제56권4호
    • /
    • pp.160-170
    • /
    • 2006
  • The purpose of this study is to analyze the image of color combination in fashion design. For this study 14,121 color samples were collected from 116 fashion brands selected by the market segmentation based on the results of the previous studies. The brands have high market share and brand recognition in each segmental market. The color samples were measured by spectrophotometer and analyzed by the Munsell's H V/C and CIE $L^*a^*b^*$ value. The representative colors of each market were selected concerning the tensity in CIE $L^*a^*b^*$ color space and the distance between the color samples. h4 a result, 2,213 representative colors were chosen. These color samples composed top and bottom color combination samples by the program 'Item Comparator' that calculated the color differences$({\Delta}E^*)$. Top includes the items such as blouse, shirt, and coats, bottom includes the items such as skirt and pants. The color combination samples were divided into two groups. In one group ${\Delta}E^*$ was less than 30, and In the other group ${\Delta}E^*$ was 30 or more. For investigating the image of color combination, 480 rotor combination samples were classified. The image adjectives for the survey from preceding studies and brand dictionaries were 'classic', 'modern', 'feminine', 'casual', and 'romantic', which have highly preferred in women's wear brands. The result of the study is as follows; For 'classic' 'image, YR, and greyish tone were generally preferred. In the color combination of 'casual' image, the samples with PB color and greyish tone were preferred. For 'feminine' image, RP was preferred as a top color, R, RP, P were preferred as a bottom color. For 'casual' image, PB was preferred as a top color, PB, B were preferred as a bottom color. For 'romantic' image, RP was preferred as a top color, R, P were preferred as a bottom color. The bigger the color differences between the color combination samples were, the more remarkable the image of color combination samples was.

저점도 벌크필레진과 복합레진 적층수복물의 색조 평가 (Color evaluation of low viscosity bulk-fill resin with composite resin capping layer)

  • 윤종현;정지혜;장훈상
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.294-300
    • /
    • 2015
  • 목적: 저점도 벌크필레진과 복합레진을 적층한 수복물의 색조를 평가하기 위함이다. 연구 재료 및 방법: 저점도 벌크필레진(SDR)과 A2, A3 색조의 미세혼합형 복합레진(A2, A3)을 4 mm 두께로 제작하여 광중합한 후 색차계를 이용하여 레진 시편의 CIE $L^*a^*b^*$ 값을 측정하였다. 이후 저점도 벌크필레진 상방에 2 mm 두께로 A2, A3 색조의 미세혼합형 복합레진을 적층하여(SA2, SA3) 광중합한 후 색측정을 하고(n = 10), 저점도 벌크필레진과 미세혼합형 복합레진, 그리고 이들을 적층한 시편의 색차(${\Delta}E$)를 계산하였다. 결과: $L^*$ 값은 SDR이 가장 컸고 SA2, SA3 그리고 A2, A3 순으로 감소했다. $a^*$ 값은 SDR이 가장 작았고 SA2, SA3 그리고 A2, A3 순으로 증가했다. $b^*$ 값은 SDR이 가장 작았으며 A2, SA2 그리고 A3, SA3 순으로 증가했다. 적층한 시편과 미세복합형 복합레진 시편의 ${\Delta}E$ 값은 A2와 SA2 사이에 ${\Delta}E=3.4$, A3와 SA3 사이에 ${\Delta}E=3.1$로 계산되었다. 결론: 저점도 벌크필레진과 미세혼합형 복합레진을 적층한 시편과 미세혼합형 복합레진만으로 제작한 시편의 색조의 차이는 일반적으로 인지하지 못할 정도로 작았다.

포스트의 종류에 따른 Empress 2 도재관의 색상에 관한 비교연구 (COLOR COMPARISON OF VARIOUS POST SYSTEMS WITH EMPRESS 2 CROWNS)

  • 이영수;유동엽
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.197-207
    • /
    • 2001
  • Development of new ceramics and esthetic needs of patients increase the use of all ceramic restorations. Fractured teeth often need metal post and core as foundation for final restoration. When all ceramic restorations are planned, metal post and core may lead to compromised esthetics because of opacity and gray color of metal post and core. Many techniques have been proposed to solve this problem such as application of an opaque porcelain to the metal core or all ceramic post and core. This study was performed to evaluate effect on color of Empress 2 crown according to various post systems. Color was evaluated by the CIE $L^*a^*b^*$ systems and measured by spectrophotometer (Model CM-3500, Minolta, Japan). Specimens were divided into 4 groups as follows Group 1 : gold cast post specimen + Empress 2 crown specimen Group 2 : application of an opaque porcelain to gold cast post specimen + Empress 2 crown specimen Group 3 : cosmopost specimen + Empress 2 crown specimen Group 4 : In-ceram post specimen + Empress 2 crown specimen. The results obtained as follows, 1. $L^*$ Values showed that group 2, 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 2. $a^*$ Values and $b^*$ values also showed that group 2. 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 3. ${\Delta}E^* ab$ Values showed that ${\Delta}E^* ab$ 3 was the highest value and ${\Delta}E^* ab$ 5 was the lowest value.

  • PDF

Pd-Ag 및 Ni-Cr 합금의 금 전착이 전장 레진의 색채에 미치는 영향 (EFFECT OF GOLD ELECTRODEPOSIT OF PD-AG, NI-CR ALLOYS ON THE COLOR OF VENERRED RESIN)

  • 양홍서;박영준
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.645-661
    • /
    • 1995
  • As the mechanical property of composite resin improved, composite resin has been widely used esthetic dentistry. In the field of esthetic dentistry, the color of prosthetic material is very important. The purpose of this study was to evaluate the color difference of specimens, by the types of alloys and gold electrodeposit. Experimental groups were as follows : Group Prec : Au-Pt alloy with no gold coating and no resin veneer. Group Semi : Pd-Ag alloy with no gold coating and no resin veneer. Group BAse : Ni-Cr alloy with no gold coating and no resin veneer. Group Gsem : Pd-Ag alloy with no gold coating and no resin veneer. Group Gbas : Ni-Cr alloy with no gold coating and no resin veneer. Group PreR : Resin veneer on the Pd-Ag alloy without gold coating. Group SemR : Resin veneer on the Pd-Ag alloy without gold coating. Group GbsR : Resin veneer on the Ni-Cr alloy with gold coating Group BasR : Resin veneer on the Ni-Cr alloy without gold coating. In this study, colors of metal surfaces and veneered resins were evaluated by the CIE $L^{*}a^{*}b$ system. The results obtained were as follows : 1. different alloy types and gold coating make the $L^{*}a^{*}b$ system. 2. The ${\Delta}E^*$ab value between groups semi and Base was less than 1.5 and there was no $a^*$ and $b^*$ value difference between groups Gsem and Gbas 3. The values of $L^*$ and $a^*$ ain groups GsemR and GbasR were so similar that the ${\Delta}E^*$ab value was as small as 0.58. 4. In resin specimens with gold coated semiprecious or base alloys showed yellower and redder deviation than the resin specimens with precious alloy. 5. The ${\Delta}E^*$ab values between goups PreR-GsemR and groups PreR-GbasR were as small as 2.68 and 2.22 respectively.

  • PDF

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • 제8권2호
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

레진시멘트의 색안정성에 대한 가속시험 (COLOR STABILITY OF THE RESIN CEMENTS WITH ACCELERATED AGING)

  • 송하정;박수정;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제33권4호
    • /
    • pp.389-396
    • /
    • 2008
  • 본 연구는 레진 시멘트의 색 안정성을 평가하여, 레진 시멘트의 변색에 의한 심미 수복물의 실패의 가능성을 평가하고자 시행하였다. 4종의 이원중합형 레진 시멘트인 Panavia-F (PA, KURARAY), Duolink (DL; BISCO), Variolink II (VL; Ivoclar Vivadent), 및 RelyX Unicem (UC: 3M ESPE)과 1종의 자가중합형 레진 시멘트인 Resiment Ready-Mix (with fluoride) CE (RM: j.1.Blosser)를 사용하였으며, 대조군으로 복합레진 Gradia Direct (CD ; GC)과 복합 레진 인레이용 Tecera Dentin A3 (TE ; Bisco)를 사용했다. 각 재료 당 직경 6.5 mm, 두께 4.5 mm의 디스크형 시편 10개를 제작하였다. 중합 후 시편은 분광색채계측기인 Spectrolino (GretagMacbeth)를 이용해 CIE $L^*a^*b^*$값을 측정하고 가속시험을 위해 빛이 차단된 refrigerated bath circulator에서 60$^{\circ}C$ 증류수에 30일간 보관 후에 색 측정을 시행하고, 시험 전 후의 색차를 계산하였다. 가속 시험 후 $L^*$ 값은 감소하는 양상을 보였고, $a^*$ 값은 증가하는 양상을 보였지만 유의한 차이는 없었다. 반면 $b^*$ 값은 유의하게 증가하였다 (p < 0.05). TE가 15일과 30일 모두에서 가장 적은 색변화 (p < 0.05)를 보인 반면 GD는 15일 가속 실험 후 큰 색변화를 보였다. 30일 가속 실험 후 PA, VL, RM, DL 그리고 UC 순으로 ${\Delta}E^*$값이 커졌으며 (p < 0.05), 30일 후 모든 레진시멘트 들은 육안으로 변색을 인지 할 수 있는 3 이상의 ${\Delta}E^*$ 값을 보였다.

레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향 (Effect of resin cement color on the color of commercially available zirconia crown)

  • 하현승;임범순;이상훈
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.233-242
    • /
    • 2018
  • 본 연구의 목적은 레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향을 평가하는 것이다. 연구에는 $NuSmile^{(R)}$ ZR Zirconia LT Shade (LT) 지르코니아와 $RelyX^{TM}$ U200 TR, A2, A3O (TR, A2, A3O) 레진시멘트를 사용했다. 이 때 지르코니아와 레진시멘트 시편은 직경 5 mm, 두께 1 mm의 디스크 형으로 각 조건 당 다섯 개씩 제작했다. CIE $L^*a^*b^*$값은 검은색과 흰색 배경에서 분광 광도계를 사용해 지르코니아와 레진시멘트 단독 조건과 겹친 조건에서 각각 측정했다. 레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향은 측정된 값을 이용해, 반투명도(TP, translucency parameter), 대조비(CR, contrast ratio), 색차(${\Delta}E{^*}_{ab}$)의 계산을 통해 평가했다. 각 변수에 대한 평균값과 표준편차는 동일한 실험군에서 CIE $L^*a^*^b^*$ 값을 3회씩 측정하여 구했다. 실험군의 통계적 유의성은 일원배치 분산분석(one-way ANOVA)과 Tukey-multiple comparisons test로 검증했다. 그 결과, 지르코니아 하방에 레진시멘트를 겹친 조건일 때는 지르코니아 단독 조건일 때에 비해 반투명도는 감소했고(p<0.05) 대조비는 증가했다. 검은색 배경에서 지르코니아와 지르코니아 하방에 레진시멘트를 겹쳤을 때의 색차는 모든 실험군에서 색의 변화를 인지할 수 없었고 LT/A3O 조합에서 최소값을 보였다. 한편, 흰색 배경에서 지르코니아와 지르코니아 하방에 레진시멘트를 겹쳤을 때의 색차는 LT/TR 조합에서 색변화를 임상적으로 허용할 수 있는 경계값을 보였다. LT/A2 조합에서는 색변화를 임상적으로 허용할 수 없었고, LT/A3O 조합에서는 색변화를 인지할 수 있었으나 임상적으로 허용할 수 있는 수준이었다. 이상의 결과와 같이 본 연구의 한계 내에서는, 흰색 배경의 LT/A2 조합 외에는 지르코니아 색상에 임상적으로 허용할 수 없는 색변화를 주는 레진시멘트는 없었다. 그 중 지르코니아 색상에 최소한의 영향을 미치는 레진시멘트 색상은 A3O였다. 따라서, 본 연구와 동일한 상용 지르코니아 크라운을 치아에 접착할 때 색변화를 최소화하기 위해서는 A3O 색상의 레진시멘트 사용이 추천된다.